This study is to compare three-dimensional(3D)isotropic T2-weighted magnetic resonance imaging(MRI)with compressed sensing-sampling perfection with application optimized contrast(CS-SPACE)and the conventional image(3D...This study is to compare three-dimensional(3D)isotropic T2-weighted magnetic resonance imaging(MRI)with compressed sensing-sampling perfection with application optimized contrast(CS-SPACE)and the conventional image(3D-SPACE)sequence in terms of image quality,estimated signal-to-noise ratio(SNR),relative contrast-to-noise ratio(CNR),and the lesions’conspicuous of the female pelvis.Thirty-six females(age:51,28-73)with cervical carcinoma(n=20),rectal carcinoma(n=7),or uterine fibroid(n=9)were included.Patients underwent magnetic resonance(MR)imaging at a 3T scanner with the sequences of 3D-SPACE,CS-SPACE,and twodimensional(2D)T2-weighted turbo-spin echo(TSE).Quantitative analyses of estimated SNR and relative CNR between tumors and other tissues,image quality,and tissue conspicuity were performed.Two radiologists assessed the difference in diagnostic findings for carcinoma.Quantitative values and qualitative scores were analyzed,respectively.The estimated SNR and the relative CNR of tumor-to-muscle obturator internus,tumor-to-myometrium,and myometrium-to-muscle obturator internus was comparable between 3D-SPACE and CS-SPACE.The overall image quality and the conspicuity of the lesion scores of the CS-SPACE were higher than that of the 3D-SPACE(P<0.01).The CS-SPACE sequence offers shorter scan time,fewer artifacts,and comparable SNR and CNR to conventional 3D-SPACE,and has the potential to improve the performance of T2-weighted images.展开更多
目的探讨Radial 3D VIBE在儿童自由呼吸下腹部平扫获得T1加权图像的临床应用。方法选取我院2015年1月~2015年8月行腹部磁共振检查患者100例,T1加权图像均采用常规梯度回波序列和Radial 3D VIBE序列分别扫描。结果对两种扫描序列定性分析...目的探讨Radial 3D VIBE在儿童自由呼吸下腹部平扫获得T1加权图像的临床应用。方法选取我院2015年1月~2015年8月行腹部磁共振检查患者100例,T1加权图像均采用常规梯度回波序列和Radial 3D VIBE序列分别扫描。结果对两种扫描序列定性分析,结果表明Radial 3D VIBE序列得的信噪比和对比噪声比均显著高于常规序列,图像质量明显提高,能够清晰显示病变部位。与常规序列相比,Radial 3D VIBE序列出现呼吸运动伪影显著低于常规序列,P<0.05。结论 Radial 3D VIBE序列可提高磁共振成像分辨率,有效减少呼吸运动伪影,提高图像质量。展开更多
Spinal dural arteriovenous fistulas (SDAVF) account for about 70% of all spinal AV shunts. We re-port on a 56-year-old male patient with progressive neurological symptoms. Pre- and post-contrast MR imaging of the spin...Spinal dural arteriovenous fistulas (SDAVF) account for about 70% of all spinal AV shunts. We re-port on a 56-year-old male patient with progressive neurological symptoms. Pre- and post-contrast MR imaging of the spine, including contrast-enhanced MR angiography was done on a 1.5 T MR scanner. In addition a special (pre-contrast) 3D turbo-spin-echo sequence with variable flip angle evolution (SPACE) was performed providing a slice thickness of 0.9 mm. T2-weighted images showed extensive widened and tortuous vascular structures with typical flow voids intradurally due to dilated pial veins. The origin of the spinal dural arteriovenous fistula was found to be the radiculomeningeal artery at level D10/11 on the left side, visualized by the T2-weighted 3D SPACE sequence and CE MRA. After imaging the patient was referred to an interventional neuroradiology department for therapy. With the detailed information from MR imaging concerning the fistula level the interventional radiologist was able to find the fistula immediately and consequently treated it successfully by endovascular therapy. Interpreting the MR images of this obvious case of a SDAVF, SPACE sequence after post processing with 3D MPR software directly led to the location of the AV shunt at D10/11 on the left side, better than 3D contrast-enhanced MR angiography did. Therefore, SPACE can be a useful adjunct in further evaluation of spinal dural arteriovenous fistula and especially in defining fistula level.展开更多
文摘This study is to compare three-dimensional(3D)isotropic T2-weighted magnetic resonance imaging(MRI)with compressed sensing-sampling perfection with application optimized contrast(CS-SPACE)and the conventional image(3D-SPACE)sequence in terms of image quality,estimated signal-to-noise ratio(SNR),relative contrast-to-noise ratio(CNR),and the lesions’conspicuous of the female pelvis.Thirty-six females(age:51,28-73)with cervical carcinoma(n=20),rectal carcinoma(n=7),or uterine fibroid(n=9)were included.Patients underwent magnetic resonance(MR)imaging at a 3T scanner with the sequences of 3D-SPACE,CS-SPACE,and twodimensional(2D)T2-weighted turbo-spin echo(TSE).Quantitative analyses of estimated SNR and relative CNR between tumors and other tissues,image quality,and tissue conspicuity were performed.Two radiologists assessed the difference in diagnostic findings for carcinoma.Quantitative values and qualitative scores were analyzed,respectively.The estimated SNR and the relative CNR of tumor-to-muscle obturator internus,tumor-to-myometrium,and myometrium-to-muscle obturator internus was comparable between 3D-SPACE and CS-SPACE.The overall image quality and the conspicuity of the lesion scores of the CS-SPACE were higher than that of the 3D-SPACE(P<0.01).The CS-SPACE sequence offers shorter scan time,fewer artifacts,and comparable SNR and CNR to conventional 3D-SPACE,and has the potential to improve the performance of T2-weighted images.
文摘目的探讨Radial 3D VIBE在儿童自由呼吸下腹部平扫获得T1加权图像的临床应用。方法选取我院2015年1月~2015年8月行腹部磁共振检查患者100例,T1加权图像均采用常规梯度回波序列和Radial 3D VIBE序列分别扫描。结果对两种扫描序列定性分析,结果表明Radial 3D VIBE序列得的信噪比和对比噪声比均显著高于常规序列,图像质量明显提高,能够清晰显示病变部位。与常规序列相比,Radial 3D VIBE序列出现呼吸运动伪影显著低于常规序列,P<0.05。结论 Radial 3D VIBE序列可提高磁共振成像分辨率,有效减少呼吸运动伪影,提高图像质量。
文摘Spinal dural arteriovenous fistulas (SDAVF) account for about 70% of all spinal AV shunts. We re-port on a 56-year-old male patient with progressive neurological symptoms. Pre- and post-contrast MR imaging of the spine, including contrast-enhanced MR angiography was done on a 1.5 T MR scanner. In addition a special (pre-contrast) 3D turbo-spin-echo sequence with variable flip angle evolution (SPACE) was performed providing a slice thickness of 0.9 mm. T2-weighted images showed extensive widened and tortuous vascular structures with typical flow voids intradurally due to dilated pial veins. The origin of the spinal dural arteriovenous fistula was found to be the radiculomeningeal artery at level D10/11 on the left side, visualized by the T2-weighted 3D SPACE sequence and CE MRA. After imaging the patient was referred to an interventional neuroradiology department for therapy. With the detailed information from MR imaging concerning the fistula level the interventional radiologist was able to find the fistula immediately and consequently treated it successfully by endovascular therapy. Interpreting the MR images of this obvious case of a SDAVF, SPACE sequence after post processing with 3D MPR software directly led to the location of the AV shunt at D10/11 on the left side, better than 3D contrast-enhanced MR angiography did. Therefore, SPACE can be a useful adjunct in further evaluation of spinal dural arteriovenous fistula and especially in defining fistula level.