Four-dimensional flow magnetic resonance imaging incirrhosis 被引量:6
1
作者 Zoran Stankovic 《World Journal of Gastroenterology》 SCIE CAS 2016年第1期89-102,共14页
Since its introduction in the 1970’s,magnetic resonance imaging(MRI)has become a standard imaging modality.With its broad and standardized application,it is firmly established in the clinical routine and an essential... Since its introduction in the 1970’s,magnetic resonance imaging(MRI)has become a standard imaging modality.With its broad and standardized application,it is firmly established in the clinical routine and an essential element in cardiovascular and abdominal imaging.In addition to sonography and computer tomography,MRI is a valuable tool for diagnosing cardiovascular and abdominal diseases,for determining disease severity,and for assessing therapeutic success.MRI techniques have improved over the last few decades,revealing not just morphologic information,but functional information about perfusion,diffusion and hemodynamics as well.Four-dimensional(4D)flow MRI,a time-resolved phase contrast-MRI with three-dimensional(3D)anatomic coverage and velocity encoding along all three flow directions has been used to comprehensively assess complex cardiovascular hemodynamics in multiple regions of the body.The technique enables visualization of 3D blood flow patterns and retrospective quantification of blood flow parameters in a region of interest.Over the last few years,4D flow MRI has been increasingly performed in the abdominal region.By applying different acceleration techniques,taking 4D flow MRI measurements has dropped to a reasonable scanning time of 8 to 12 min.These new developments have encouraged a growing number of patient studies in the literature validating the technique’s potential for enhanced evaluation of blood flow parameters within the liver’s complex vascular system.The purpose of this review article is to broaden our understanding of 4D flow MRI for the assessment of liver hemodynamics by providing insights into acquisition,data analysis,visualization and quantification.Furthermore,in this article we highlight its development,focussing on the clinical application of the technique. 展开更多
关键词 Four-dimensional flow magnetic resonanceimaging phase contrast-magnetic resonance imaging Liver CIRRHOSIS imaging technique HEMODYNAMICS Bloodflow Visualization quantification TIPS SPLANCHNIC system
下载PDF
MR流量测定面积的实验研究 被引量:1
2
作者 杨广夫 姚晓群 +10 位作者 何斌 刘建军 李金柱 韩博 闫新成 薛彤霄 杨小军 刘晖 张保其 张文奎 富宪民 《现代医用影像学》 2007年第4期145-147,共3页
目的:实验研究MR流量测定中不同流量、不同流向、不同感兴趣区(ROI)位置与不同ROI面积的关系。材料与方法:使用PHILIPS1.5T双梯磁共振机流量测定程序,测量2mm内径塑胶管不同流量水(0.5、1.0、1.5、2.0、2.5ml/s),不同流向(流入及流出方... 目的:实验研究MR流量测定中不同流量、不同流向、不同感兴趣区(ROI)位置与不同ROI面积的关系。材料与方法:使用PHILIPS1.5T双梯磁共振机流量测定程序,测量2mm内径塑胶管不同流量水(0.5、1.0、1.5、2.0、2.5ml/s),不同流向(流入及流出方向)、不同ROI位置(测量图中心区和偏中心区)与不同的ROI面积流量变化关系,统计计算标准的ROI面积。结果:在不同流量、流向和测量位置中,流量与ROI面积大小存在明显的直线相关(r>0.95,P<0.05),ROI面积大小显著的影响测量结果,相位编码图的面积均大于实际面积,当ROI面积取值等于实际面积时,所测结果与实际流量一致。在不同流量下的不同流向及ROI位置对流量测定无影响(P>0.05)。结论:MR流量测定ROI面积必须与实际面积一致。 展开更多
关键词 磁共振成像 磁共振定量流量测定 相位对比 实验研究
下载PDF