期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Magnetic resonance-guided focused ultrasound for essential tremor:a prospective,single center,single-arm study
1
作者 Rui Zong Xuemei Li +10 位作者 Chunyu Yin Jianfeng He Dekang Zhang Xiangbing Bian Lichao Huang Jiayou Zhou Zhipei Ling Lin Ma Xin Lou Longsheng Pan Xinguang Yu 《Neural Regeneration Research》 SCIE CAS CSCD 2024年第9期2075-2080,共6页
The safety and effectiveness of magnetic resonance-guided focused ultrasound thalamotomy has been broadly established and validated for the treatment of essential tremor.In 2018,the first magnetic resonance-guided foc... The safety and effectiveness of magnetic resonance-guided focused ultrasound thalamotomy has been broadly established and validated for the treatment of essential tremor.In 2018,the first magnetic resonance-guided focused ultrasound system in Chinese mainland was installed at the First Medical Center of the PLA General Hospital.This prospective,single center,open-label,single-arm study was part of a worldwide prospective multicenter clinical trial(ClinicalTrials.gov Identifier:NCT03253991)conducted to confirm the safety and efficacy of magnetic resonance-guided focused ultrasound for treating essential tremor in the local population.From 2019 to 2020,10 patients with medication refractory essential tremor were recruited into this open-label,single arm study.The treatment efficacy was determined using the Clinical Rating Scale for Tremor.Safety was evaluated according to the incidence and severity of adverse events.All of the subjects underwent a unilateral thalamotomy targeting the ventral intermediate nucleus.At the baseline assessment,the estimated marginal mean of the Clinical Rating Scale for Tremor total score was 58.3±3.6,and this improved after treatment to 23.1±6.4 at a 12-month follow-up assessment.A total of 50 adverse events were recorded,and 2 were defined as serious.The most common intraoperative adverse events were nausea and headache.The most frequent postoperative adverse events were paresthesia and equilibrium disorder.Most of the adverse events were mild and usually disappeared within a few days.Our findings suggest that magnetic resonance-guided focused ultrasound for the treatment of essential tremor is effective,with a good safety profile,for patients in Chinese mainland. 展开更多
关键词 efficacy essential tremor magnetic resonance-guided focused ultrasound(MRgFUS) movement disorder safety stereotactic therapy THALAMOTOMY ventral intermediate nucleus
下载PDF
Evaluation Value of Intravoxel Incoherent Motion Diffusion-Weighted Imaging on Early Efficacy of Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation for Uterine Adenomyoma
2
作者 唐纳 顾坚骏 +4 位作者 尹肖睿 虞容江 徐元涛 李相 王悍 《Journal of Shanghai Jiaotong university(Science)》 EI 2022年第2期226-230,共5页
To investigate the evaluation value of intravoxel incoherent motion diffusion-weighted imaging(IVIM-DWI)on the early efficacy of magnetic resonance-guided high-intensity focused ultrasound(MRgFUS)ablation for uterine ... To investigate the evaluation value of intravoxel incoherent motion diffusion-weighted imaging(IVIM-DWI)on the early efficacy of magnetic resonance-guided high-intensity focused ultrasound(MRgFUS)ablation for uterine adenomyoma.The clinical and magnetic resonance imaging(MRI)data of 36 patients with uterine adenomyoma before and after MRgFUS treatment in our hospital from January 2018 to December 2018 were retrospectively analyzed.All the 36 patients underwent MRI examination one day before operation and immediately after operation using GE Discovery MR7503.0T MRI,including conventional sequences(T1WI,T2WI,and T2 fat suppression sequences)plain scan,IVIM-DWI sequences with 9 b values,and contrast enhanced-MRI sequences.The IVIM-DWI quantitative parameters(true diffusion coefficient D,perfusion related diffusion coefficient D*,and perfusion fraction f)of double-exponential model were obtained by using GE ADW 4.7 functool,a postprocessor.SPSS 24.0 software was used to analyze the difference in parameter between the ablation and non-ablation areas of uterine adenomyoma.DWI signal in the ablation area of uterine adenomyoma was increased,and manifested as heterogeneous diffuse high signal,with low central signal and high edge signal.Values of D,D*and f in the ablation area of uterine adenomyoma were significantly lower than those in the non-ablation area,and there was statistical difference between the two(P<0.05).The areas under receiver operating characteristic(ROC)curve of D,D*and f values in the ablation area of uterine adenomyoma were 0.854,0.898 and 0.924,respectively;the optimal thresholds for the diagnosis of ablation area of uterine adenomyoma were 0.81×10−3 mm2/s,4.99×10−3 mm2/s and 0.24,respectively;the diagnostic sensitivity was 80.6%,72.2%and 94.4%,respectively;and the specificity was 91.7%,97.2%and 94.4%,respectively.IVIM-DWI has a certain clinical value in the evaluation on early efficacy of MRgFUS ablation of uterine adenomyosis. 展开更多
关键词 intravoxel incoherent motion diffusion-weighted imaging(IVIM-DWI) uterine adenomyoma magnetic resonance-guided high-intensity focused ultrasound(MRgFUS)
原文传递
Renal ablation using magnetic resonance-guided high intensity focused ultrasound: Magnetic resonance imaging and histopathology assessment
3
作者 Maythem Saeed Roland Krug +2 位作者 Loi Do Steven W Hetts Mark W Wilson 《World Journal of Radiology》 CAS 2016年第3期298-307,共10页
AIM: To use magnetic resonance-guided high intensity focused ultrasound(MRg-HIFU), magnetic resonance imaging(MRI) and histopathology for noninvasively ablating, quantifying and characterizing ablated renal tissue. ME... AIM: To use magnetic resonance-guided high intensity focused ultrasound(MRg-HIFU), magnetic resonance imaging(MRI) and histopathology for noninvasively ablating, quantifying and characterizing ablated renal tissue. METHODS: Six anesthetized/mechanically-ventilated pigs underwent single/double renal sonication(n = 24) using a 3T-MRg-HIFU(1.1 MHz frequency and 3000J-4400 J energies). T2-weighted fast spin echo(T2-W), perfusion saturation recovery gradient echo and contrast enhanced(CE) T1-weighted(T1-W) sequences were used for treatment planning, temperature monitoring, lesion visualization, characterization and quantification, respectively. Histopathology was conducted in excised kidneys to quantify and characterize cellular and vascular changes. Paired Student's t-test was used and a P-value < 0.05 was considered statistically significant.RESULTS: Ablated renal parenchyma could not be differentiated from normal parenchyma on T2-W or nonCE T1-W sequences. Ablated renal lesions were visible as hypoenhanced regions on perfusion and CE T1-W MRI sequences, suggesting perfusion deficits and necrosis. Volumes of ablated parenchyma on CE T1-W images invivo(0.12-0.36 cm3 for single sonication 3000 J, 0.50-0.84 cm3, for double 3000 J, 0.75-0.78 cm3 for single 4400 J and 0.12-2.65 cm3 for double 4400J) and at postmortem(0.23-0.52 cm3, 0.25-0.82 cm3, 0.45-0.68 cm3 and 0.29-1.80 cm3, respectively) were comparable. The ablated volumes on 3000 J and 4400 J double sonication were significantly larger than single(P < 0.01), thus, the volume and depth of ablated tissue depends on the applied energy and number of sonication. Macroscopic and microscopic examinations confirmed the locations and presence of coagulation necrosis, vascular damage and interstitial hemorrhage, respectively.CONCLUSION: Contrast enhanced MRI provides assessment of MRg-HIFU renal ablation. Histopathology demonstrated coagulation necrosis, vascular damage and confirmed the volume of damage seen on MRI. 展开更多
关键词 magnetic resonance-guided high INTENSITY focused ultrasound RENAL ablation magnetic RESONANCE imaging Microscopy High INTENSITY focused ultrasound
下载PDF
Current applications for magnetic resonance-guided focused ultrasound in the treatment of Parkinson’s disease 被引量:1
4
作者 Haoxuan Lu Xiaoyu Wang Xin Lou 《Chinese Medical Journal》 SCIE CAS CSCD 2023年第7期780-787,共8页
Magnetic resonance-guided focused ultrasound(MRgFUS)is a novel and minimally invasive technology.Since the US Food and Drug Administration approved unilateral ventral intermediate nucleus-MRgFUS for medication-refract... Magnetic resonance-guided focused ultrasound(MRgFUS)is a novel and minimally invasive technology.Since the US Food and Drug Administration approved unilateral ventral intermediate nucleus-MRgFUS for medication-refractory essential tremor in 2016,studies on new indications,such as Parkinson’s disease(PD),psychiatric diseases,and brain tumors,have been on the rise,and MRgFUS has become a promising method to treat such neurological diseases.Currently,as the second most common degenerative disease,PD is a research hotspot in the field of MRgFUS.The actions of MRgFUS on the brain range from thermoablation,blood-brain barrier(BBB)opening,to neuromodulation.Intensity is a key determinant of ultrasound actions.Generally,high intensity can be used to precisely thermoablate brain targets,whereas low intensity can be used as molecular therapies to modulate neuronal activity and open the BBB in conjunction with injected microbubbles.Here,we aimed to summarize advances in the application of MRgFUS for the treatment of PD,with a focus on thermal ablation,BBB opening,and neuromodulation,in the hope of informing clinicians of current applications. 展开更多
关键词 magnetic resonance-guided focused ultrasound THERMOABLATION Blood-brain barrier Parkinson’s disease NEUROMODULATION
原文传递
Universal Software Architecture of Magnetic Resonance-Guided Focused Ultrasound Surgery System and Experimental Study
5
作者 张胜发 唐纳 +2 位作者 沈国峰 王悍 乔杉 《Journal of Shanghai Jiaotong university(Science)》 EI 2021年第4期471-481,共11页
Magnetic resonance-guided focused ultrasound surgery (MRgFUS) is an emerging, non-invasive hyperthermia technology which can be used for the treatment of benign and malignant tumours, in conjunction with intracranial ... Magnetic resonance-guided focused ultrasound surgery (MRgFUS) is an emerging, non-invasive hyperthermia technology which can be used for the treatment of benign and malignant tumours, in conjunction with intracranial neurological diseases. To treat different indications, it is often necessary to design special focused ultrasound devices and treatment plans, which poses great challenges and results in substantial costs during software development. This article introduces a general software architecture that can be applied to three different focused ultrasound devices for the treatment of uterine fibroids, breast fibroids, and pain palliation of bone metastases, respectively, and can be integrated with GE Discovery or Signa MRI scanners and Xingaoyi BroadScan MRI scanners. Finally, the proposed software architecture was shown to possess desirable universality and safety through various tests and animal experimental studies. 展开更多
关键词 magnetic resonance-guided focused ultrasound surgery(MRgFUS) software architecture focused ultrasound surgery workflow MRI thermometry
原文传递
New frontiers in focal therapy for prostate cancer:Prostate-specific membrane antigen positron emission tomography/magnetic resonance imaging
6
作者 Celeste Manfredi Esau Fernandez-Pascual +2 位作者 Estefanía Linares-Espinós Felipe Couñago Juan Ignacio Martínez-Salamanca 《World Journal of Clinical Oncology》 CAS 2021年第2期61-68,共8页
Imaging has a central role in the context of focal therapy(FT)for prostate cancer(PCa).Prostate-specific membrane antigen(PSMA)positron emission tomography/magnetic resonance imaging(PET/MRI)is a novel imaging modalit... Imaging has a central role in the context of focal therapy(FT)for prostate cancer(PCa).Prostate-specific membrane antigen(PSMA)positron emission tomography/magnetic resonance imaging(PET/MRI)is a novel imaging modality that combines the morpho-functional information of MRI with the molecular characterization of PET.Some papers reported the potential advantages of PSMA PET/MRI in different clinical scenarios.Limited evidence on PSMA PET/MRI is available in the setting of FT.PSMA PET/MRI can be an effective imaging modality for detecting primary PCa and seems to provide accurate local staging of primary PCa.PSMA PET/MRI also shows high performance for restaging and detecting tumor recurrence.The higher soft-tissue contrast and the reduction of ionizing radiation are the main advantages reported in the literature compared to PET/computed tomography.PSMA PET/MRI could represent a turning point in the management of patients with PCa in the context of FT.Further studies are needed to confirm its applications in this specific clinical setting. 展开更多
关键词 Prostate-specific membrane antigen Positron emission tomography/magnetic resonance imaging Prostate cancer Focal therapy high-intensity focused ultrasound CRYOTHERAPY
下载PDF
High-intensity focused ultrasound tumor ablation:Review of ten years of clinical experience 被引量:3
7
作者 Lian ZHANG Zhi-Biao WANG 《Frontiers of Medicine》 SCIE CSCD 2010年第3期294-302,共9页
High-intensity focused ultrasound(HIFU)is a technique to destroy tissue at depth within the body,selectively and without harming overlying and adjacent structures within the path of the beam because the ultrasonic int... High-intensity focused ultrasound(HIFU)is a technique to destroy tissue at depth within the body,selectively and without harming overlying and adjacent structures within the path of the beam because the ultrasonic intensity at the beam focus is much higher than that outside of the focus.Diagnostic ultrasound is the first imaging modality used for guiding HIFU ablation.In 1997,a patient with osteosarcoma was first successfully treated with ultrasound imaging-guided HIFU in Chongqing,China.Over the last decade,thousands of patients with uterine fibroids,liver cancer,breast cancer,pancreatic cancer,bone tumors,and renal cancer have been treated with ultrasound imaging-guided HIFU.Based on several research groups’reports,as well as our ten-year clinical experience,we conclude that this technique is safe and effective in treating human solid tumors.HIFU is a promising technique.Most importantly,HIFU offers patients another alternative when those patients have no other treatment available. 展开更多
关键词 high-intensity focused ultrasound(HIFU) ultrasound imaging-guided HIFU(USgHIFU) magnetic resonance imaging-guided HIFU(MRgHIFU)
原文传递
上一页 1 下一页 到第