The full-potential linearized augmented plane wave plus local orbital method is utilized for exploring the electronic,magnetic,and magneto-optical properties of the NiX_(2)(X=Cl,Br,and I)single layer.The first-princip...The full-potential linearized augmented plane wave plus local orbital method is utilized for exploring the electronic,magnetic,and magneto-optical properties of the NiX_(2)(X=Cl,Br,and I)single layer.The first-principles calculation demonstrates that these compounds are ferromagnetic indirect semiconductors,and the energy band gaps of NiX_(2)for X=Cl,Br,and I are 3.888,3.134,and 2.157 eV,respectively.The magnetic moments of Ni atoms in NiX_(2)monolayer are 1.656,1.588,1.449μB,and their magneto-crystalline anisotropy energies are 0.167,0.029,0.090 meV,respectively.Based on the macro-linear response theory,we systematically studied the influences of the external magnetic field and out-of-plane strain on the magneto-optical Kerr effect(MOKE)spectrum of the NiX_(2)single layer.It is found that,when the external magnetic field is perpendicular to the sample plane,the value of the Kerr rotation angle reaches the maximum,and the single-layer NiI_(2)material has a Kerr rotation angle of 1.89°at the photon energy of 1.986 eV.Besides,the Kerr rotation spectrum of NiCl_(2)and NiBr_(2)monolayers redshift as the out-of-plane strain increases,while NiI_(2)monolayer blueshifts.Accurate computation of the MOKE spectrum of NiX_(2)materials provides an opportunity for applications of 2D magnetic material ranging from sensing to data storing.展开更多
We show that an optical transparency can be obtained by using only one single magneto-optical ring resonator. This effect is based on the splitting of counterclockwise and clockwise modes in the ring resonator. Within...We show that an optical transparency can be obtained by using only one single magneto-optical ring resonator. This effect is based on the splitting of counterclockwise and clockwise modes in the ring resonator. Within a proposed resonator-waveguide configuration the superposition between the two degeneracy broken modes produces a transparency window,which can be closed, open, and modified by tuning the applied magnetic field. This phenomenon is an analogue of Autler–Townes splitting, and the magnetic field is equivalent to the strong external pump field. We provide a theoretic analysis on the induced transparency, and numerically demonstrate the effect using full-wave simulation. Feasible implication of this effect and its potential applications are also discussed.展开更多
This paper proposed a high-sensitivity phase imaging eddy current magneto-optical (PI-ECMO) system for carbon fiber reinforced polymer (CFRP) defect detection. In contrast to other eddy current-based detection systems...This paper proposed a high-sensitivity phase imaging eddy current magneto-optical (PI-ECMO) system for carbon fiber reinforced polymer (CFRP) defect detection. In contrast to other eddy current-based detection systems, the proposed system employs a fixed position excitation coil while enabling the detection point to move within the detection region. This configuration effectively mitigates the interference caused by the lift-off effect, which is commonly observed in systems with moving excitation coils. Correspondingly, the relationship between the defect characteristics (orientation and position) and the surface vertical magnetic field distribution (amplitude and phase) is studied in detail by theoretical analysis and numerical simulations. Experiments conducted on woven CFRP plates demonstrate that the designed PI-ECMO system is capable of effectively detecting both surface and internal cracks, as well as impact defects. The excitation current is significantly reduced compared with traditional eddy current magneto-optical (ECMO) systems.展开更多
Control and detection of antiferromagnetic topological materials are challenging since the total magnetization vanishes.Here we investigate the magneto-optical Kerr and Faraday effects in bilayer antiferromagnetic ins...Control and detection of antiferromagnetic topological materials are challenging since the total magnetization vanishes.Here we investigate the magneto-optical Kerr and Faraday effects in bilayer antiferromagnetic insulator Mn Bi2Te4.We find that by breaking the combined mirror symmetries with either perpendicular electric field or external magnetic moment,Kerr and Faraday effects occur.Under perpendicular electric field,antiferromagnetic topological insulators(AFMTI)show sharp peaks at the interband transition threshold,whereas trivial insulators show small adjacent positive and negative peaks.Gate voltage and Fermi energy can be tuned to reveal the differences between AFMTI and trivial insulators.We find that AFMTI with large antiferromagnetic order can be proposed as a pure magneto-optical rotator due to sizable Kerr(Faraday)angles and vanishing ellipticity.Under external magnetic moment,AFMTI and trivial insulators are significantly different in the magnitude of Kerr and Faraday angles and ellipticity.For the qualitative behaviors,AFMTI shows distinct features of Kerr and Faraday angles when the spin configurations of the system change.These phenomena provide new possibilities to optically detect and manipulate the layered topological antiferromagnets.展开更多
We have established a caesium double magneto-optical trap (MOT) system for cavity-QED experiment, and demonstrated the continuous transfer of cold caesium atoms from the vapour-cell MOT with a pressure of - 1 ×...We have established a caesium double magneto-optical trap (MOT) system for cavity-QED experiment, and demonstrated the continuous transfer of cold caesium atoms from the vapour-cell MOT with a pressure of - 1 × 10^-6 Pa to the ultra-high-vacuum (UHV) MOT with a pressure of - 8 × 10^-8 Pa via a focused continuous-wave transfer laser beam. The effect of frequency detuning as well as the intensity of the transfer beam is systematically investigated, which makes the transverse cooling adequate before the atoms leak out of the vapour-cell MOT to reduce divergence of the cold atomic beam. The typical cold atomic flux got from vapour-cell MOT is - 2 × 10^7 atoms/s. About 5 × 10^6 caesium atoms are recaptured in the UHV MOT.展开更多
The magneto-optical Kerr effect of the HfO2/Co/HfO2/A1 multilayer structure is investigated in this work, and an ob- vious cavity enhancement of the Kerr response for the HfO2 semiconductor is found both theoretically...The magneto-optical Kerr effect of the HfO2/Co/HfO2/A1 multilayer structure is investigated in this work, and an ob- vious cavity enhancement of the Kerr response for the HfO2 semiconductor is found both theoretically and experimentally. Surprisingly, a maximum value of about -3 of the polar Kerr rotation for s-polarized incident light is observed in our experiment. We propose that this improvement on the Kerr effect can be attributed to the multiple reflection and optical interference in the cavity, which can also be proved by simulation using the finite element method.展开更多
The longitudinal generalized magneto-optical ellipsometry (GME) method is extended to the measurement of three- layer ultrathin magnetic films. In this work, the theory of the reflection matrix is introduced into th...The longitudinal generalized magneto-optical ellipsometry (GME) method is extended to the measurement of three- layer ultrathin magnetic films. In this work, the theory of the reflection matrix is introduced into the GME measurement to obtain the reflective matrix parameters of ultrathin multilayer magnetic films with different thicknesses. After that, a spectroscopic ellipsometry is used to determine the optical parameter and the thickness of every layer of these samples, then the magneto-optical coupling constant of the multilayer magnetic ultrathin film can be obtained. After measurements of a series of ultrathin Fe films, the results show that the magneto-optical coupling constant Q is independent of the thickness of the magnetic film. The magneto-optical Kerr rotations and ellipticity are measured to confirm the validity of this experiment. Combined with the optical constants and the Q constant, the Kerr rotations and ellipticity are calculated in theory. The results show that the theoretical curve fits very well with the experimental data.展开更多
Based on our work on single cesium atoms trapped in a large-magnetic-gradient vapour-cell magneto-optical trap (MOT), the signal-to-noise ratio (SNR) is remarkably improved. Also a far-off-resonance optical dipole...Based on our work on single cesium atoms trapped in a large-magnetic-gradient vapour-cell magneto-optical trap (MOT), the signal-to-noise ratio (SNR) is remarkably improved. Also a far-off-resonance optical dipole trap (FORT) formed by a strongly-focused 1064 nm single frequency Nd:YVO4 laser beam is introduced. One cesium atom is prepared in the MOT, and then it can transfer successfully between the MOT and the FORT which is overlapped with the MOT. Utilizing the effective transfer, the lifetime of single atoms trapped in the FORT is measured to be 6.9± 0.3 s. Thus we provide a system where the atomic qubit can be coherently manipulated.展开更多
In current investigations of electric arc plasmas, experiments based on modern testing technology play an important role. To enrich the testing methods and contribute to the understanding and grasping of the inherent ...In current investigations of electric arc plasmas, experiments based on modern testing technology play an important role. To enrich the testing methods and contribute to the understanding and grasping of the inherent mechanism of air switching arcs, in this paper, a nonintrusive detecting system is described that combines the magneto-optic imaging(MOI) technique with the solution to inverse electromagnetic problems. The detecting system works in a sequence of main steps as follows: MOI of the variation of the arc flux density over a plane, magnetic field information extracted from the magneto-optic(MO) images, arc current density distribution and spatial pattern reconstruction by inverting the resulting field data. Correspondingly, in the system, an MOI set-up is designed based on the Faraday effect and the polarization properties of light, and an intelligent inversion algorithm is proposed that involves simulated annealing(SA).Experiments were carried out for high current(2 kA RMS) discharge cases in a typical low-voltage switchgear. The results show that the MO detection system possesses the advantages of visualization, high resolution and response, and electrical insulation, which provides a novel diagnostics tool for further studies of the arc.展开更多
Single caesium atoms in a large-magnetic-gradient vapour-cell magneto-optical trap have been identified. The trapping of individual atoms is marked by the steps in fluorescence signal corresponding to the capture or l...Single caesium atoms in a large-magnetic-gradient vapour-cell magneto-optical trap have been identified. The trapping of individual atoms is marked by the steps in fluorescence signal corresponding to the capture or loss of single atoms. The typical magnetic gradient is about 29 mT/cm, which evidently reduces the capture rate of magneto-optical trap.展开更多
The magnetic and magneto-optical properties of heavily doped Bi∶YIG film were studied. The film was deposited by radio frequency magnetron sputtering method and crystallized by rapid recurrent thermal annealing (RRTA...The magnetic and magneto-optical properties of heavily doped Bi∶YIG film were studied. The film was deposited by radio frequency magnetron sputtering method and crystallized by rapid recurrent thermal annealing (RRTA). The results show that the RRTA treated film has good properties both in microwave and optical wave band. The saturation magnetization of the film on different substrates varies from 135.7 to 138.6 kA·m-1. The coercive field of the film on GGG substrate is about 0.32 kA·m-1, while about 0.8-1.43 kA·m-1 on YAG substrate and 1.75 kA·m-1 on Al2O3 substrate. The Faraday angle is about 3-5 (°)·μm-1 when optical wavelength ranges at 450-600 nm. The transmission spectra of the Bi∶YIG films on three substrates has similar change as annealing temperature below 800 ℃. Specially, when annealing temperature is above 800 ℃ a step is observed between 550 and 650 nm wavelength for the film deposited on Al2O3 substrate.Three results are very useful in magneto-optical recording application and integrated microwave devices.展开更多
A cold atom source is important for quantum metrology and precision measurement.To reduce the quantum projection noise limit in optical lattice clock,one can increase the number of cold atoms and reduce the dead time ...A cold atom source is important for quantum metrology and precision measurement.To reduce the quantum projection noise limit in optical lattice clock,one can increase the number of cold atoms and reduce the dead time by enhancing the loading rate.In this work,we realize an enhanced cold mercury atom source based on a two-dimensional(2D)magnetooptical trap(MOT).The vacuum system is composed of two titanium chambers connected with a differential pumping tube.Two stable cooling laser systems are adopted for the 2D-MOT and the three-dimensional(3D)-MOT,respectively.Using an optimized 2D-MOT and push beam,about 1.3×10^(6)atoms,which are almost an order of magnitude higher than using a pure 3D-MOT,are loaded into the 3D-MOT for202Hg atoms.This enhanced cold mercury atom source is helpful in increasing the frequency stability of a neutral mercury lattice clock.展开更多
The glass-forming region of B2O3-Al2O3-SiO2 (BAS) glass heavily doped with rare earth oxides was investigated by an effective method, and the chemical stability was investigated by powder method. Influences of rare ...The glass-forming region of B2O3-Al2O3-SiO2 (BAS) glass heavily doped with rare earth oxides was investigated by an effective method, and the chemical stability was investigated by powder method. Influences of rare earth oxides on the glass-forming ability and the chemical stability of the BAS glass were also discussed. The experimental results show that the BAS glass-forming region expands firstly with the increase of the Tb2O3 content up to 30mol% and then shrinks. The acid-resistant capacity of the BAS glass doped with rare earth oxides is the lowest, the water-resistant capacity is secondary, and the alkali-resistant capacity is the best. Besides, the glass chemical stability can be improved by doping appropriate amount of rare earth oxides. Moreover, the stronger the ionic polarization ability of the rare earth ions is, the better the chemical stability of the BAS glass will be.展开更多
Mercury is a promising candidate for the optical lattice clock, due to its low sensitivity to the blackbody radiation. We develop a single folded beam magneto-optical trap for the neutral mercury optical lattice clock...Mercury is a promising candidate for the optical lattice clock, due to its low sensitivity to the blackbody radiation. We develop a single folded beam magneto-optical trap for the neutral mercury optical lattice clock, with a 253. 7nm frequency quadrupled laser. Up to 1.7 × 10^6 (202Hg) or 1.5 × 10^6 (199Hg) atoms can be captured, and the atom temperature is lowered to 170μK (202Hg) or 50μK (199Hg). The cold atom signals of all six rich abundant isotopes are observed in this system.展开更多
The magneto-optical Kerr effect susceptometry technique is proposed to determine the uniaxial magnetic anisotropy (UMA) constant Ku. The magnetic properties of Cu/Fe/SiO2/Si grown by dc magnetron sputtering were inv...The magneto-optical Kerr effect susceptometry technique is proposed to determine the uniaxial magnetic anisotropy (UMA) constant Ku. The magnetic properties of Cu/Fe/SiO2/Si grown by dc magnetron sputtering were investigated. The in-plane uniaxial magnetic anisotropy was probed by the magneto-optical Kerr effect (MOKE). The value of UMA, Ku = 2.5 x 103 J/m3, was simulated from the field dependence of ac susceptibility along the hard axis according to the Stoner-Wohlfarth (S-W) model, which is consistent with Ku = 2.7~ 103 J/m3 calculated from the magnetic hysteresis loops. Our results show that the magneto-optical Kerr effect susceptometry can be employed to determine the magnetic anisotropy constant owing to its high sensitivity.展开更多
The growth in the capacity of electric power system creates a demand for the protection of relaying systems. Optical current transducers—OCT that are mainly made up of single mode optical fibers which are subjected t...The growth in the capacity of electric power system creates a demand for the protection of relaying systems. Optical current transducers—OCT that are mainly made up of single mode optical fibers which are subjected to Faraday rotation are used as a replacement for electromagnetic transducers due to their immunity to electromagnetic interference. However, the principal parameter in this system, the sensitivity to magnetic fields or current, depends on the Verdet constant, which is low in the case of optical fibers. However, the optical path length can be increased to compensate for it by winding the fiber around a current carrying element a large number of turns. In this work, we study a current sensor, which is made up of a conductor coil with a fiber inside, thus increasing sensitivity. We study the effect of the inhomogeneity of the magnetic field induced by the current on the sensitivity of the optical fiber sensor.展开更多
With nanovoids buried in Co films, resonant structures were observed in spectra of polar magneto-optical Kerr effect(MOKE), where both a narrow bandwidth and high intensity were acquired. Through changing the thickn...With nanovoids buried in Co films, resonant structures were observed in spectra of polar magneto-optical Kerr effect(MOKE), where both a narrow bandwidth and high intensity were acquired. Through changing the thickness of Co films and the lattice of voids, different optical modes were introduced. For a very shallow array of voids, the resonant MOKE was induced by Ag plasma edge resonance, for deeper ones, hybrid plasma modes, such as void plasmons in the voids, surface lattice plasmons between the voids, and the co-action of them, etc. resulted in resonant MOKE. We found that resonant MOKE resulted from the void plasmons resonance which possesses the narrowest bandwidth for the lowest absorption of voids. The simulated electromagnetic field(EF) distribution consolidated different effects of these three optical modes on resonant MOKE modulation. Such resonant polar MOKE possesses high sensitivity, which might pave the way to on-chip MO devices.展开更多
Magneto-optic fiber Bragg gratings (MFBG) based on magneto-optic materials have a lot of potential applications for sensing and optical signal processing. The transmission and reflection spectra of guided optical wa...Magneto-optic fiber Bragg gratings (MFBG) based on magneto-optic materials have a lot of potential applications for sensing and optical signal processing. The transmission and reflection spectra of guided optical waves in the MFBG are investigated. According to the sensitivity of MFBG spectral lines to the magneto-optic coupling intensity varying with applied magnetic field, a novel magnetic field sensor of high-resolution up to 0.01 nm/(kA/m) is predicted.展开更多
Microwave magneto-optic (MO) modulators can directly transform radio frequency (RF) signals into optical data through the Bragg diffraction of guided optical waves (GOWs) induced by microwave magneto-static wav...Microwave magneto-optic (MO) modulators can directly transform radio frequency (RF) signals into optical data through the Bragg diffraction of guided optical waves (GOWs) induced by microwave magneto-static waves (MSWs). According to the MO coupled-mode theory, the modulation of continuous GOWs by a rectangular magneto-static-forwardvolume-wave (MSFVW) pulse in MO film waveguide is studied in the small signal case and the modulated optical pulse at the output is analyzed by means of an analytical form, which is dependent on the instantaneous diffraction intensity determined by the overlap of rectangular MSFVW pulse and light beam aperture. On the basis of it, the characteristics of MSFVW-based MO modulators can be explained well for the case of rectangular pulse modulation. It is also shown that the line codes of optical data generated by MO Bragg modulators can be controlled by adjusting the duty factor of modulating pulse signals.展开更多
The studies were made on the preparation processes of the rare earth metal and alloy target materials and their characterization. In this work the rare earth metals were prepared by electrolysis of the oxide in molten...The studies were made on the preparation processes of the rare earth metal and alloy target materials and their characterization. In this work the rare earth metals were prepared by electrolysis of the oxide in molten salt for Nd metal and metallothermic reduction of the fluorides for Gd, Tb, Dy metals. After vacuum refining and distillation purification these rare earth metals were used for manufacturing the element targets, mosaic targets and as the starting materials of preparing the rare earth-transition metal (RE-TM) alloy targets. The four kinds of Dy-FeCo, NdDy-FeCo, Tb-FeCo and GdTb-FeCo alloy targets with diameter of 100 mm and thickness of 3 mm were prepared using powder metallurgical technique. The oxygen content and microstructure of the prepared RE-TM cast alloys and sintered targets were analyzed. The features and requirements of the RE-TM alloy sputtering target materials were also discussed.展开更多
文摘The full-potential linearized augmented plane wave plus local orbital method is utilized for exploring the electronic,magnetic,and magneto-optical properties of the NiX_(2)(X=Cl,Br,and I)single layer.The first-principles calculation demonstrates that these compounds are ferromagnetic indirect semiconductors,and the energy band gaps of NiX_(2)for X=Cl,Br,and I are 3.888,3.134,and 2.157 eV,respectively.The magnetic moments of Ni atoms in NiX_(2)monolayer are 1.656,1.588,1.449μB,and their magneto-crystalline anisotropy energies are 0.167,0.029,0.090 meV,respectively.Based on the macro-linear response theory,we systematically studied the influences of the external magnetic field and out-of-plane strain on the magneto-optical Kerr effect(MOKE)spectrum of the NiX_(2)single layer.It is found that,when the external magnetic field is perpendicular to the sample plane,the value of the Kerr rotation angle reaches the maximum,and the single-layer NiI_(2)material has a Kerr rotation angle of 1.89°at the photon energy of 1.986 eV.Besides,the Kerr rotation spectrum of NiCl_(2)and NiBr_(2)monolayers redshift as the out-of-plane strain increases,while NiI_(2)monolayer blueshifts.Accurate computation of the MOKE spectrum of NiX_(2)materials provides an opportunity for applications of 2D magnetic material ranging from sensing to data storing.
基金supported by the National Natural Science Foundation of China (Grant No. 12104227)the Scientific Research Foundation of Nanjing Institute of Technology (Grant No. YKJ202021)the Guizhou Provincial Science and Technology Projects (Grant No. ZK [2022] general 035)。
文摘We show that an optical transparency can be obtained by using only one single magneto-optical ring resonator. This effect is based on the splitting of counterclockwise and clockwise modes in the ring resonator. Within a proposed resonator-waveguide configuration the superposition between the two degeneracy broken modes produces a transparency window,which can be closed, open, and modified by tuning the applied magnetic field. This phenomenon is an analogue of Autler–Townes splitting, and the magnetic field is equivalent to the strong external pump field. We provide a theoretic analysis on the induced transparency, and numerically demonstrate the effect using full-wave simulation. Feasible implication of this effect and its potential applications are also discussed.
基金the National Natural Science Foundation of China under Grants No.U2030205,No.62003075,No.61903065,and No.62003074Sichuan Science and Technology Planning Project under Grant No.2022JDJQ0040.
文摘This paper proposed a high-sensitivity phase imaging eddy current magneto-optical (PI-ECMO) system for carbon fiber reinforced polymer (CFRP) defect detection. In contrast to other eddy current-based detection systems, the proposed system employs a fixed position excitation coil while enabling the detection point to move within the detection region. This configuration effectively mitigates the interference caused by the lift-off effect, which is commonly observed in systems with moving excitation coils. Correspondingly, the relationship between the defect characteristics (orientation and position) and the surface vertical magnetic field distribution (amplitude and phase) is studied in detail by theoretical analysis and numerical simulations. Experiments conducted on woven CFRP plates demonstrate that the designed PI-ECMO system is capable of effectively detecting both surface and internal cracks, as well as impact defects. The excitation current is significantly reduced compared with traditional eddy current magneto-optical (ECMO) systems.
基金Project supported by the National Natural Science Foundation of China(Grant No.11904062)the Starting Research Fund from Guangzhou University(Grant No.RQ2020076)Guangzhou Basic Research Program,jointed funded by Guangzhou University(Grant No.202201020186)。
文摘Control and detection of antiferromagnetic topological materials are challenging since the total magnetization vanishes.Here we investigate the magneto-optical Kerr and Faraday effects in bilayer antiferromagnetic insulator Mn Bi2Te4.We find that by breaking the combined mirror symmetries with either perpendicular electric field or external magnetic moment,Kerr and Faraday effects occur.Under perpendicular electric field,antiferromagnetic topological insulators(AFMTI)show sharp peaks at the interband transition threshold,whereas trivial insulators show small adjacent positive and negative peaks.Gate voltage and Fermi energy can be tuned to reveal the differences between AFMTI and trivial insulators.We find that AFMTI with large antiferromagnetic order can be proposed as a pure magneto-optical rotator due to sizable Kerr(Faraday)angles and vanishing ellipticity.Under external magnetic moment,AFMTI and trivial insulators are significantly different in the magnitude of Kerr and Faraday angles and ellipticity.For the qualitative behaviors,AFMTI shows distinct features of Kerr and Faraday angles when the spin configurations of the system change.These phenomena provide new possibilities to optically detect and manipulate the layered topological antiferromagnets.
基金Project supported by the Natural Science Foundation of China (Grant Nos 60578018 10434080, and 10374062), the Sino-Russia Joint Project (NSFC-RFBR), by the Key Scientific Project of the Education Ministry of China (Grant No 204019), the Cultivation Fund of the Key Scientific and Technical Innovation Project (Grant No 705010) and the Program for Innovative Research Team in University (IRT0516) from the Education Ministry of China, and also by the Research Funds for Youth Academic Leaders of Shanxi Province.
文摘We have established a caesium double magneto-optical trap (MOT) system for cavity-QED experiment, and demonstrated the continuous transfer of cold caesium atoms from the vapour-cell MOT with a pressure of - 1 × 10^-6 Pa to the ultra-high-vacuum (UHV) MOT with a pressure of - 8 × 10^-8 Pa via a focused continuous-wave transfer laser beam. The effect of frequency detuning as well as the intensity of the transfer beam is systematically investigated, which makes the transverse cooling adequate before the atoms leak out of the vapour-cell MOT to reduce divergence of the cold atomic beam. The typical cold atomic flux got from vapour-cell MOT is - 2 × 10^7 atoms/s. About 5 × 10^6 caesium atoms are recaptured in the UHV MOT.
基金supported by the National Key Project of Fundamental Research of China(Grant Nos.2012CB932304 and 2010CB923404)the National Natural Science Foundation of China(Grant Nos.50971070 and U1232210)the Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘The magneto-optical Kerr effect of the HfO2/Co/HfO2/A1 multilayer structure is investigated in this work, and an ob- vious cavity enhancement of the Kerr response for the HfO2 semiconductor is found both theoretically and experimentally. Surprisingly, a maximum value of about -3 of the polar Kerr rotation for s-polarized incident light is observed in our experiment. We propose that this improvement on the Kerr effect can be attributed to the multiple reflection and optical interference in the cavity, which can also be proved by simulation using the finite element method.
基金Project supported by the National Basic Research Program of China(Grant No.2009CB929400)the Independent Innovation Foundation of Shandong University,China(Grant No.2012ZB040)
文摘The longitudinal generalized magneto-optical ellipsometry (GME) method is extended to the measurement of three- layer ultrathin magnetic films. In this work, the theory of the reflection matrix is introduced into the GME measurement to obtain the reflective matrix parameters of ultrathin multilayer magnetic films with different thicknesses. After that, a spectroscopic ellipsometry is used to determine the optical parameter and the thickness of every layer of these samples, then the magneto-optical coupling constant of the multilayer magnetic ultrathin film can be obtained. After measurements of a series of ultrathin Fe films, the results show that the magneto-optical coupling constant Q is independent of the thickness of the magnetic film. The magneto-optical Kerr rotations and ellipticity are measured to confirm the validity of this experiment. Combined with the optical constants and the Q constant, the Kerr rotations and ellipticity are calculated in theory. The results show that the theoretical curve fits very well with the experimental data.
基金supported by the National Natural Science Foundation of China (Grant Nos 60578018 and 10434080)the project for excellent research team from the National Natural Science Foundation of China (Grant No 60821004)+4 种基金the Program for New Century Excellent Talents of the Education Ministry of China (Grant No NCET-07-0524)the State Basic Key Research Program of China (Grant No 2006CB921102)the Specialized Research Fund for the Doctoral Program of Higher Education of China(Grant No 20070108003)the Natural Science Foundation of Shanxi Province,China (Grant No 2007011003)the Scientific Research Funds for Returned Scholars Abroad of Shanxi Province,China
文摘Based on our work on single cesium atoms trapped in a large-magnetic-gradient vapour-cell magneto-optical trap (MOT), the signal-to-noise ratio (SNR) is remarkably improved. Also a far-off-resonance optical dipole trap (FORT) formed by a strongly-focused 1064 nm single frequency Nd:YVO4 laser beam is introduced. One cesium atom is prepared in the MOT, and then it can transfer successfully between the MOT and the FORT which is overlapped with the MOT. Utilizing the effective transfer, the lifetime of single atoms trapped in the FORT is measured to be 6.9± 0.3 s. Thus we provide a system where the atomic qubit can be coherently manipulated.
基金supported by the Fundamental Research Funds for the Central Universities of China(XJJ2011019)
文摘In current investigations of electric arc plasmas, experiments based on modern testing technology play an important role. To enrich the testing methods and contribute to the understanding and grasping of the inherent mechanism of air switching arcs, in this paper, a nonintrusive detecting system is described that combines the magneto-optic imaging(MOI) technique with the solution to inverse electromagnetic problems. The detecting system works in a sequence of main steps as follows: MOI of the variation of the arc flux density over a plane, magnetic field information extracted from the magneto-optic(MO) images, arc current density distribution and spatial pattern reconstruction by inverting the resulting field data. Correspondingly, in the system, an MOI set-up is designed based on the Faraday effect and the polarization properties of light, and an intelligent inversion algorithm is proposed that involves simulated annealing(SA).Experiments were carried out for high current(2 kA RMS) discharge cases in a typical low-voltage switchgear. The results show that the MO detection system possesses the advantages of visualization, high resolution and response, and electrical insulation, which provides a novel diagnostics tool for further studies of the arc.
基金Project supported by the National Natural Science Foundation of China (Grant Nos 60578018 and 10434080)the State Key Research Program of China (Grant No 2006CB921102)+2 种基金the Program for New Century Excellent Talents of the Education Ministry, China (Grant No NCET-07-0524)the Specialized Research Fund for the Doctoral Program of China (Grant No 20070108003)the Natural Science Foundation of Shanxi Province, China (Grant No 2007011003)
文摘Single caesium atoms in a large-magnetic-gradient vapour-cell magneto-optical trap have been identified. The trapping of individual atoms is marked by the steps in fluorescence signal corresponding to the capture or loss of single atoms. The typical magnetic gradient is about 29 mT/cm, which evidently reduces the capture rate of magneto-optical trap.
基金This work was supported by the National Natural Science Foundation of China (No.60425102)
文摘The magnetic and magneto-optical properties of heavily doped Bi∶YIG film were studied. The film was deposited by radio frequency magnetron sputtering method and crystallized by rapid recurrent thermal annealing (RRTA). The results show that the RRTA treated film has good properties both in microwave and optical wave band. The saturation magnetization of the film on different substrates varies from 135.7 to 138.6 kA·m-1. The coercive field of the film on GGG substrate is about 0.32 kA·m-1, while about 0.8-1.43 kA·m-1 on YAG substrate and 1.75 kA·m-1 on Al2O3 substrate. The Faraday angle is about 3-5 (°)·μm-1 when optical wavelength ranges at 450-600 nm. The transmission spectra of the Bi∶YIG films on three substrates has similar change as annealing temperature below 800 ℃. Specially, when annealing temperature is above 800 ℃ a step is observed between 550 and 650 nm wavelength for the film deposited on Al2O3 substrate.Three results are very useful in magneto-optical recording application and integrated microwave devices.
文摘A cold atom source is important for quantum metrology and precision measurement.To reduce the quantum projection noise limit in optical lattice clock,one can increase the number of cold atoms and reduce the dead time by enhancing the loading rate.In this work,we realize an enhanced cold mercury atom source based on a two-dimensional(2D)magnetooptical trap(MOT).The vacuum system is composed of two titanium chambers connected with a differential pumping tube.Two stable cooling laser systems are adopted for the 2D-MOT and the three-dimensional(3D)-MOT,respectively.Using an optimized 2D-MOT and push beam,about 1.3×10^(6)atoms,which are almost an order of magnitude higher than using a pure 3D-MOT,are loaded into the 3D-MOT for202Hg atoms.This enhanced cold mercury atom source is helpful in increasing the frequency stability of a neutral mercury lattice clock.
文摘The glass-forming region of B2O3-Al2O3-SiO2 (BAS) glass heavily doped with rare earth oxides was investigated by an effective method, and the chemical stability was investigated by powder method. Influences of rare earth oxides on the glass-forming ability and the chemical stability of the BAS glass were also discussed. The experimental results show that the BAS glass-forming region expands firstly with the increase of the Tb2O3 content up to 30mol% and then shrinks. The acid-resistant capacity of the BAS glass doped with rare earth oxides is the lowest, the water-resistant capacity is secondary, and the alkali-resistant capacity is the best. Besides, the glass chemical stability can be improved by doping appropriate amount of rare earth oxides. Moreover, the stronger the ionic polarization ability of the rare earth ions is, the better the chemical stability of the BAS glass will be.
基金Supported by the National Natural Science Foundation of China under Grant No 91436105the National Basic Research Program of China under Grant No 2011CB921504the Research Project of Shanghai Science and Technology Commission under Grant No 09DJ1400700
文摘Mercury is a promising candidate for the optical lattice clock, due to its low sensitivity to the blackbody radiation. We develop a single folded beam magneto-optical trap for the neutral mercury optical lattice clock, with a 253. 7nm frequency quadrupled laser. Up to 1.7 × 10^6 (202Hg) or 1.5 × 10^6 (199Hg) atoms can be captured, and the atom temperature is lowered to 170μK (202Hg) or 50μK (199Hg). The cold atom signals of all six rich abundant isotopes are observed in this system.
基金Project supported by the National Basic Research Program of China(Grant Nos.2009CB929201,2011CB921801,and 2012CB933102)the National Natural Science Foundation of China(Grant Nos.50931006,11034004,51021061,and 11274033)
文摘The magneto-optical Kerr effect susceptometry technique is proposed to determine the uniaxial magnetic anisotropy (UMA) constant Ku. The magnetic properties of Cu/Fe/SiO2/Si grown by dc magnetron sputtering were investigated. The in-plane uniaxial magnetic anisotropy was probed by the magneto-optical Kerr effect (MOKE). The value of UMA, Ku = 2.5 x 103 J/m3, was simulated from the field dependence of ac susceptibility along the hard axis according to the Stoner-Wohlfarth (S-W) model, which is consistent with Ku = 2.7~ 103 J/m3 calculated from the magnetic hysteresis loops. Our results show that the magneto-optical Kerr effect susceptometry can be employed to determine the magnetic anisotropy constant owing to its high sensitivity.
文摘The growth in the capacity of electric power system creates a demand for the protection of relaying systems. Optical current transducers—OCT that are mainly made up of single mode optical fibers which are subjected to Faraday rotation are used as a replacement for electromagnetic transducers due to their immunity to electromagnetic interference. However, the principal parameter in this system, the sensitivity to magnetic fields or current, depends on the Verdet constant, which is low in the case of optical fibers. However, the optical path length can be increased to compensate for it by winding the fiber around a current carrying element a large number of turns. In this work, we study a current sensor, which is made up of a conductor coil with a fiber inside, thus increasing sensitivity. We study the effect of the inhomogeneity of the magnetic field induced by the current on the sensitivity of the optical fiber sensor.
基金Project supported by the Natural Science Foundation of Shandong Province,China(Grant No.ZR2015AM024)the Doctoral Research Started Funding of Qufu Normal University,China(Grant No.BSQD20130152)
文摘With nanovoids buried in Co films, resonant structures were observed in spectra of polar magneto-optical Kerr effect(MOKE), where both a narrow bandwidth and high intensity were acquired. Through changing the thickness of Co films and the lattice of voids, different optical modes were introduced. For a very shallow array of voids, the resonant MOKE was induced by Ag plasma edge resonance, for deeper ones, hybrid plasma modes, such as void plasmons in the voids, surface lattice plasmons between the voids, and the co-action of them, etc. resulted in resonant MOKE. We found that resonant MOKE resulted from the void plasmons resonance which possesses the narrowest bandwidth for the lowest absorption of voids. The simulated electromagnetic field(EF) distribution consolidated different effects of these three optical modes on resonant MOKE modulation. Such resonant polar MOKE possesses high sensitivity, which might pave the way to on-chip MO devices.
基金supported by the National Natural Science Foundation of China under Grant No. 60671027the Application Basis Research Foundation of Sichuan Province under Grant No. 07JY029-089.
文摘Magneto-optic fiber Bragg gratings (MFBG) based on magneto-optic materials have a lot of potential applications for sensing and optical signal processing. The transmission and reflection spectra of guided optical waves in the MFBG are investigated. According to the sensitivity of MFBG spectral lines to the magneto-optic coupling intensity varying with applied magnetic field, a novel magnetic field sensor of high-resolution up to 0.01 nm/(kA/m) is predicted.
基金supported by the National Natural Science Foundation of China under Grant No 60671027the Application Basis Research Foundation of Sichuan Province under Grant No 07JY029-089
文摘Microwave magneto-optic (MO) modulators can directly transform radio frequency (RF) signals into optical data through the Bragg diffraction of guided optical waves (GOWs) induced by microwave magneto-static waves (MSWs). According to the MO coupled-mode theory, the modulation of continuous GOWs by a rectangular magneto-static-forwardvolume-wave (MSFVW) pulse in MO film waveguide is studied in the small signal case and the modulated optical pulse at the output is analyzed by means of an analytical form, which is dependent on the instantaneous diffraction intensity determined by the overlap of rectangular MSFVW pulse and light beam aperture. On the basis of it, the characteristics of MSFVW-based MO modulators can be explained well for the case of rectangular pulse modulation. It is also shown that the line codes of optical data generated by MO Bragg modulators can be controlled by adjusting the duty factor of modulating pulse signals.
基金Former the Ministry of Metallurgical Industry of China (BJ95-06-01)
文摘The studies were made on the preparation processes of the rare earth metal and alloy target materials and their characterization. In this work the rare earth metals were prepared by electrolysis of the oxide in molten salt for Nd metal and metallothermic reduction of the fluorides for Gd, Tb, Dy metals. After vacuum refining and distillation purification these rare earth metals were used for manufacturing the element targets, mosaic targets and as the starting materials of preparing the rare earth-transition metal (RE-TM) alloy targets. The four kinds of Dy-FeCo, NdDy-FeCo, Tb-FeCo and GdTb-FeCo alloy targets with diameter of 100 mm and thickness of 3 mm were prepared using powder metallurgical technique. The oxygen content and microstructure of the prepared RE-TM cast alloys and sintered targets were analyzed. The features and requirements of the RE-TM alloy sputtering target materials were also discussed.