期刊文献+
共找到35,553篇文章
< 1 2 250 >
每页显示 20 50 100
Simultaneous Determination of 14 β-Receptor Agonists Residues in Mutton by High Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS)
1
作者 Zhe MENG Jianhua WANG +5 位作者 Bo LIU Yuhang GUO Haoshuang DONG Pingyang SHAN Dawei WANG Yajuan SONG 《Agricultural Biotechnology》 CAS 2023年第5期55-58,共4页
[Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-g... [Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-glucuronidase and extracted with 5%acetic acid-acetonitrile(1:99,V/V)solution.An Eclipse plus C 18 column was used for separation,and the MRM mode was used for qualitative analysis,and the external standard method was used for quantitative analysis of matrix standard solutions.[Results]Under the optimal conditions,the retention time of the 14 kinds ofβ-receptor agonists ranged from 1.0 to 9.5 min.When the mass concentration was in the range of 0.05-0.50μg/ml,the linear relationship ofβ-receptor agonists was good,with correlation coefficients(r)≥0.9992.The detection limits of the method were in the range of 0.04-0.87μg/kg,and the quantitative limits were in the range of 0.35-1.86μg/kg.The average recovery values were in the range of 82.8%-108.9%,with RSDs(n=6)in the range of 1.9%-6.7%.[Conclusions]The method is simple,sensitive,reproducible,accurate,and can be used for simultaneous determination of the 14 kinds ofβ-receptor agonist residues in mutton. 展开更多
关键词 MUTTON High performance liquid chromatography-tandem mass spectrometry β-receptor agonist RESIDUE
下载PDF
基于不确定度评估研究ID-LC-MS/MS法检测鸡蛋中氟虫腈砜残留量的关键控制点
2
作者 张巧艳 方维焕 +3 位作者 郑蔚然 王夏君 刘超纲 王强 《浙江农业学报》 CSCD 北大核心 2024年第3期643-650,共8页
为了控制检测结果准确性,以鸡蛋粉中氟虫腈砜残留分析标准物质[GBW(E)100779]为测试样,采用“自下而上”法对基于多功能净化柱(PAC柱)净化的同位素稀释液相色谱串联质谱(ID-LC-MS/MS)法进行测量不确定度评估。“鱼骨图”分析表明,不确... 为了控制检测结果准确性,以鸡蛋粉中氟虫腈砜残留分析标准物质[GBW(E)100779]为测试样,采用“自下而上”法对基于多功能净化柱(PAC柱)净化的同位素稀释液相色谱串联质谱(ID-LC-MS/MS)法进行测量不确定度评估。“鱼骨图”分析表明,不确定度分量主要来源有样品称样量、内标溶液添加体积、标准工作溶液浓度及其移取体积。内标溶液添加体积引入的不确定度最大,对检测结果不确定度的贡献率为68.59%;万分之一天平称量引入的不确定度可忽略不计。同位素内标的添加过程是ID-LC-MS/MS法检测的关键控制点,参考基准的合理选择和目标物的完全提取是准确测量的前提。进一步用LC-MS/MS法对参考物质、稀释剂和内标溶液的适用性进行了评估,并基于国家有证标准物质[GBW(E)100779]对提取方法进行了优化。研究结果有利于提升鸡蛋食品安全的检测质量和质控水平,为精准检测质控方案的设计提供新思路。 展开更多
关键词 测量不确定度 鸡蛋 氟虫腈砜 同位素稀释液相色谱串联质谱法(ID-lc-ms/MS) 质量控制 标准物质
下载PDF
自动QuEChERS结合UPLC-MS/MS测定莲雾中苯并咪唑类农药残留
3
作者 齐宁利 刘元婧 +3 位作者 陈吴海 莫华升 林梅清 龚霄 《保鲜与加工》 CAS 北大核心 2024年第5期98-103,共6页
为了建立自动QuEChERS结合高效液相色谱-串联质谱法测定莲雾中多菌灵、噻菌灵、苯菌灵及甲基硫菌灵4种苯并咪唑类农药残留量的检测方法。将莲雾样品采用混合试剂(5.5 g硫酸镁+1.5 g氯化钠+1.0 g柠檬酸钠+0.5 g柠檬酸二钠)进行净化,经QuE... 为了建立自动QuEChERS结合高效液相色谱-串联质谱法测定莲雾中多菌灵、噻菌灵、苯菌灵及甲基硫菌灵4种苯并咪唑类农药残留量的检测方法。将莲雾样品采用混合试剂(5.5 g硫酸镁+1.5 g氯化钠+1.0 g柠檬酸钠+0.5 g柠檬酸二钠)进行净化,经QuEChERS自动样品制备系统进行制备后,应用超高效液相色谱-三重四级杆串联质谱法进行分析。结果表明,4种农药在1.00~10.00 ng/mL质量浓度范围内线性关系良好,决定系数(R2)均大于0.99;0.1、1.0、5.0 mg/kg 3个添加水平下,在莲雾基质中添加回收率为84%~105%,相对标准偏差为0.8%~9.5%(n=3),方法检出限和定量限分别为0.1~0.5μg/kg和0.5~10.0μg/kg。综上,该方法简便省时,净化效果好,灵敏度及准确度高,可用于同时测定莲雾中多菌灵、噻菌灵、苯菌灵及甲基硫菌灵4种苯并咪唑类农药的残留量。 展开更多
关键词 自动QuEChERS 莲雾 苯并咪唑 农药残留 超高效液相色谱-三重四级杆串联质谱法
下载PDF
HPLC及LC-MS测定榛子中氯吡苯脲和多菌灵残留
4
作者 桑育黎 王沛 +2 位作者 郝延军 李楠楠 戚建忠 《辽宁大学学报(自然科学版)》 CAS 2024年第1期8-15,共8页
本文采用高效液相色谱法(HPLC)和液相色谱-质谱法(LC-MS)对干果榛子中氯吡苯脲和多菌灵残留量进行含量测定.HPLC和LC-MS均使用C18色谱柱,含量测定采取等度洗脱,流动相:甲醇-水(55∶45,体积比);体积流量:1.0 mL·min-1;测定波长:260 ... 本文采用高效液相色谱法(HPLC)和液相色谱-质谱法(LC-MS)对干果榛子中氯吡苯脲和多菌灵残留量进行含量测定.HPLC和LC-MS均使用C18色谱柱,含量测定采取等度洗脱,流动相:甲醇-水(55∶45,体积比);体积流量:1.0 mL·min-1;测定波长:260 nm;柱温:30℃.LC-MS采取电喷雾离子源,梯度洗脱,体积流量:0.6 mL·min-1,柱温:30℃.结果表明,榛子中氯吡苯脲与多菌灵存在残留,氯吡苯脲质量浓度在1.00~10.00μg·mL-1范围内线性关系良好,加样回收率在95.58%~100.58%;多菌灵质量浓度在1.005~15.075μg·mL-1范围内具有良好的线性关系,加样回收率在95.61%~104.39%.实验证明,HPLC与LC-MS相结合的方法具有操作简便、灵敏度高、检出限低等优点,能有效地检测到榛子样品中膨大剂氯吡苯脲及杀菌剂多菌灵的残留,并确定其残留量,线性关系和回收率结果均令人满意.根据被检测的8批样品中氯吡苯脲和多菌灵两项农药残留量推断,作为一般干果食用榛子是安全的. 展开更多
关键词 榛子 氯吡苯脲 多菌灵 高效液相色谱法(HPLC) 液相色谱-质谱法(lc-ms)
下载PDF
UPLC-MS/MS法检测3种食品中松仁过敏原
5
作者 宁亚维 周泓鑫 +4 位作者 杨正 马俊美 刘茁 张岩 李强 《食品科学》 EI CAS CSCD 北大核心 2024年第1期247-253,共7页
基于食品基质中松仁过敏原Pin k 2建立了一种超高效液相色谱-串联质谱法。将松仁经过研磨、脱脂、浸提、酶解后经Easy-nLC 1000-QExactive高分辨质谱仪进行分离分析,结合Uniprot蛋白数据库以及ProteinPilotTM软件对质谱图进行数据处理,... 基于食品基质中松仁过敏原Pin k 2建立了一种超高效液相色谱-串联质谱法。将松仁经过研磨、脱脂、浸提、酶解后经Easy-nLC 1000-QExactive高分辨质谱仪进行分离分析,结合Uniprot蛋白数据库以及ProteinPilotTM软件对质谱图进行数据处理,经BLAST验证特异性,最终筛选3条松仁特异性肽段。方法学验证结果表明,方法在0.001~50mg/mL范围内线性关系良好,定量限为1mg/kg;在饼干、巧克力和饮料3种空白基质中的平均回收率为88.50%~107.57%,相对标准偏差不高于6.08%,基质效应为89.77%~96.13%。该方法具有灵敏度高、特异性好的优势,可应用于饼干、巧克力、饮料等食品样品中松仁过敏原的检测,为我国食品标签真实性检验及食品中隐性过敏原的检测提供技术支持。 展开更多
关键词 松仁 过敏原 超高效液相色谱-串联质谱法 检测
下载PDF
自动化磁珠法提取血清脂溶性维生素应用LC-MS/MS检测的性能评价
6
作者 孔卓 李春艳 《现代检验医学杂志》 CAS 2024年第1期131-135,145,共6页
目的评估自动化磁珠法提取血清脂溶性维生素应用液相色谱串联质谱法(liquid chromatography-tandem mass spectrometry,LC-MS/MS)检测的性能。方法收集200例临床剩余血清样本,采用自动化磁珠法提取血清中脂溶性维生素A,D_(2),D_(3),E和K... 目的评估自动化磁珠法提取血清脂溶性维生素应用液相色谱串联质谱法(liquid chromatography-tandem mass spectrometry,LC-MS/MS)检测的性能。方法收集200例临床剩余血清样本,采用自动化磁珠法提取血清中脂溶性维生素A,D_(2),D_(3),E和K;同时联合LC-MS/MS检测脂溶性维生素A,D_(2),D_(3),E和K的线性、定量限、精密度、正确度、携带污染率等性能指标以及基质效应。并比较此方法与传统萃取法检测结果的一致性。结果自动化磁珠法提取脂溶性维生素A,D_(2),D_(3),E和K线性相关系数均>0.99;五种物质的定量限分别为5,0.25,0.25,125和0.025ng/ml;批内精密度和批间精密度分别为0.66%~4.83%,0.15%~3.70%;平均加标回收率为87.05%~111.11%;基质效应为95.43%~99.07%;高-低值样本循环进样结果均值与低-低值样本循环进样结果均值之差,均小于低-低值样本循环进样结果均值的3s;统计学结果显示自动化磁珠法和传统萃取法提取的脂溶性维生素结果相关性良好(r>0.99),两种方法的检测结果无显著偏倚。结论自动化磁珠法提取脂溶性维生素的检测性能良好,有望提高样品通量和分析效率。 展开更多
关键词 自动化磁珠法 液相色谱串联质谱 脂溶性维生素
下载PDF
基于LC-MS/MS测定人体类固醇激素的研究进展
7
作者 万薇 谢洁 +7 位作者 屈子裕 江游 张谛 黄泽建 王一楠 戴新华 方向 叶子弘 《质谱学报》 EI CAS CSCD 北大核心 2024年第2期201-215,共15页
类固醇激素是一类具有环戊烷多氢菲结构的化合物,由细胞色素P450酶催化形成,在调节机体代谢、促进性器官发育等方面起着重要作用。临床上将类固醇激素水平作为肾上腺疾病、精神类疾病等的诊断指标。液相色谱-串联质谱(LC-MS/MS)联用技... 类固醇激素是一类具有环戊烷多氢菲结构的化合物,由细胞色素P450酶催化形成,在调节机体代谢、促进性器官发育等方面起着重要作用。临床上将类固醇激素水平作为肾上腺疾病、精神类疾病等的诊断指标。液相色谱-串联质谱(LC-MS/MS)联用技术因具有高灵敏度、高通量和高专属性的特点,已成为类固醇临床测定的首选方法。本文综述了LC-MS/MS在内源性类固醇激素测定中的应用,特别是在样品前处理、色谱条件和质谱条件优化等方面的研究进展,为临床上类固醇激素的诊断检测提供参考。 展开更多
关键词 类固醇激素 液相色谱-串联质谱(lc-ms/MS) 样品前处理 色谱条件 质谱条件
下载PDF
固相萃取-UPLC-MS/MS法测定环境水体中多种抗生素
8
作者 秦兴秀 杨敏娜 王来梁 《环境监测管理与技术》 CSCD 北大核心 2024年第3期51-54,共4页
采用固相萃取-超高效液相色谱串联质谱法测定环境水样中25种磺胺类和喹诺酮类抗生素,通过优化试验条件,使方法在2.00μg/L~200μg/L范围内线性良好,方法检出限为1.01 ng/L~2.85 ng/L,7次测定结果的RSD为2.3%~8.0%。将该方法用于自来水... 采用固相萃取-超高效液相色谱串联质谱法测定环境水样中25种磺胺类和喹诺酮类抗生素,通过优化试验条件,使方法在2.00μg/L~200μg/L范围内线性良好,方法检出限为1.01 ng/L~2.85 ng/L,7次测定结果的RSD为2.3%~8.0%。将该方法用于自来水和地表水测定,结果均为未检出,高、低质量浓度水平的加标回收率为61.2%~102%。 展开更多
关键词 磺胺类抗生素 喹诺酮类抗生素 固相萃取 超高效液相色谱串联质谱法 水质
下载PDF
HPLC-MS/MS测定保健食品中6种大麻素
9
作者 侯巧红 张勋 +9 位作者 赵宇 齐鹤鸣 李孟璇 步献功 董昕 李燕鹭 宋清莲 邹明强 金明华 胡婷婷 《现代科学仪器》 2024年第2期10-15,共6页
目的:利用高效液相色谱-串联三重四极杆质谱(HPLC-MS/MS)对保健食品中6种大麻素进行定性定量分析。方法:HLB固相萃取小柱净化,采用XBridge C18色谱柱,乙腈溶液作为有机相,10mmol·L^(-1)乙酸铵水溶液作为水相,2种离子模式同时扫描,... 目的:利用高效液相色谱-串联三重四极杆质谱(HPLC-MS/MS)对保健食品中6种大麻素进行定性定量分析。方法:HLB固相萃取小柱净化,采用XBridge C18色谱柱,乙腈溶液作为有机相,10mmol·L^(-1)乙酸铵水溶液作为水相,2种离子模式同时扫描,同位素内标定量。结果:所测大麻素在1-100μg·L^(-1)浓度范围均呈现良好线性关系,相关系数(r2)均>0.999。方法的检出限和定量限分别为5μg·kg^(-1)和10μg·kg^(-1)。该方法稳定性好,灵敏度高,适用于常见保健食品中6种大麻素的定性定量分析。结论:本研究成功建立了保健食品中6种大麻素的定性定量分析,为保健食品品质评价、安全监管及风险防范提供技术支持。 展开更多
关键词 大麻素 保健食品 高效液相色谱-串联质谱
下载PDF
Stepped-up development of accelerator mass spectrometry method for the detection of ^(60)Fe with the HI-13 tandem accelerator
10
作者 Yang Zhang Sheng-Quan Yan +36 位作者 Ming He Qing-Zhang Zhao Wen-Hui Zhang Chao-Xin Kan Jian-Ming Zhou Kang-Ning Li Xiao-Fei Wang Jian-Cheng Liu Zhao-Hua Peng Zhuo Liang Ai-Ling Li Jian Zheng Qi-Wen Fan Yun-Ju Li You-Bao Wang Zhi-Hong Li Yang-Ping Shen Ding Nan Wei Nan Yu-Qiang Zhang Jia-Ying-Hao Li Jun-Wen Tian Jiang-Lin Hou Chang-Xin Guo Zhi-Cheng Zhang Ming-Hao Zhu Yu-Wen Chen Yu-Chen Jiang Tao Tian Jin-Long Ma Yi-Hui Liu Jing-Yu Dong Run-Long Liu Mei-Yue-Nan Ma Yong-Shou Chen Wei-Ping Liu Bing Guo 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期136-143,共8页
The Moon provides a unique environment for investigating nearby astrophysical events such as supernovae.Lunar samples retain valuable information from these events,via detectable long-lived“fingerprint”radionuclides... The Moon provides a unique environment for investigating nearby astrophysical events such as supernovae.Lunar samples retain valuable information from these events,via detectable long-lived“fingerprint”radionuclides such as^(60)Fe.In this work,we stepped up the development of an accelerator mass spectrometry(AMS)method for detecting^(60)Fe using the HI-13tandem accelerator at the China Institute of Atomic Energy(CIAE).Since interferences could not be sufficiently removed solely with the existing magnetic systems of the tandem accelerator and the following Q3D magnetic spectrograph,a Wien filter with a maximum voltage of±60 kV and a maximum magnetic field of 0.3 T was installed after the accelerator magnetic systems to lower the detection background for the low abundance nuclide^(60)Fe.A 1μm thick Si_(3)N_(4) foil was installed in front of the Q3D as an energy degrader.For particle detection,a multi-anode gas ionization chamber was mounted at the center of the focal plane of the spectrograph.Finally,an^(60)Fe sample with an abundance of 1.125×10^(-10)was used to test the new AMS system.These results indicate that^(60)Fe can be clearly distinguished from the isobar^(60)Ni.The sensitivity was assessed to be better than 4.3×10^(-14)based on blank sample measurements lasting 5.8 h,and the sensitivity could,in principle,be expected to be approximately 2.5×10^(-15)when the data were accumulated for 100 h,which is feasible for future lunar sample measurements because the main contaminants were sufficiently separated. 展开更多
关键词 Accelerator mass spectrometry Wien filter Isobar separation SUPERNOVAE Chang'e-5 lunar samples
下载PDF
LC-MS/MS法测定人尿液中乳清酸的浓度及临床应用
11
作者 杨文斌 赵雯雯 《药学与临床研究》 2024年第1期31-35,共5页
目的:建立测定人尿液中乳清酸浓度的方法,并应用于临床。方法:尿液样本加水稀释100倍,经0.22μm滤膜过滤后,取滤液100μL加入甲醇400μL沉淀蛋白,以卡马西平(0.50μg·mL^(-1))2μL为内标,经涡旋1 min,13000 r·min^(-1)离心5 m... 目的:建立测定人尿液中乳清酸浓度的方法,并应用于临床。方法:尿液样本加水稀释100倍,经0.22μm滤膜过滤后,取滤液100μL加入甲醇400μL沉淀蛋白,以卡马西平(0.50μg·mL^(-1))2μL为内标,经涡旋1 min,13000 r·min^(-1)离心5 min,取上清液100μL采用液相色谱-串联质谱(LC-MS/MS)法测定。色谱柱为Waters Atlantis dC18(4.6 mm×250 mm,5μm),流动相为5 mmol·L^(-1)甲酸铵溶液-乙腈(梯度洗脱),流速为0.50 mL·min^(-1),柱温为4℃,进样量为3μL。采用电喷雾离子源以正离子及负离子模式,检测方式为Full MS,Full MS分辨率为70000,质量扫描范围m/z 130~360。乳清酸和内标卡马西平的检测离子分别为m/z(-)155.00982、(+)237.10224。结果:乳清酸尿液浓度在0.016~1.0μg·mL^(-1)范围内线性关系良好(r^(2)=0.9967),定量下限为0.016μg·mL^(-1);日内、日间精密度的RSD<15%,RE<15%;基质效应为88.70%~98.62%;提取回收率为95.93%~103.08%;乳清酸尿液样品室温放置24 h、处理后样品4℃放置24 h的稳定性良好(RE<15%)。正常人尿液乳清酸含量为(3.10±1.23)μg·mL^(-1),鸟氨酸氨甲酰转移酶缺乏症(OTCD)患者尿液乳清酸含量为354.82~2566.57μg·mL^(-1)。结论:本研究所建方法操作简便、专属性强、灵敏度高,可用于OTCD患者的辅助诊断。 展开更多
关键词 液相色谱-串联质谱法 乳清酸 鸟氨酸氨甲酰转移酶缺乏症
下载PDF
建立LC-MS/MS检测血清中5种脂溶性维生素的方法及临床验证
12
作者 于鹏 周传贵 +4 位作者 楚士颖 李艳 迟伟 田晗 程文播 《检验医学与临床》 2024年第6期721-725,732,共6页
目的建立液相色谱-串联质谱(LC-MS/MS)方法同时检测血清中维生素A、维生素D(25-OH-D_(2)、25-OH-D_(3))、维生素E和维生素K_(1)水平,并通过血清样品验证。方法以同位素标记的维生素A-d4、25-OH-D_(2)-d6、25-OH-D_(3)-d6、维生素E-d6和... 目的建立液相色谱-串联质谱(LC-MS/MS)方法同时检测血清中维生素A、维生素D(25-OH-D_(2)、25-OH-D_(3))、维生素E和维生素K_(1)水平,并通过血清样品验证。方法以同位素标记的维生素A-d4、25-OH-D_(2)-d6、25-OH-D_(3)-d6、维生素E-d6和维生素K_(1)-d7作为内标,在血清样品中利用甲醇/乙腈混合溶液沉淀蛋白质,然后用正己烷萃取脂溶性维生素,采用Phenomenex Kinetex C18(50.0 mm×3.0 mm,2.6μm)色谱柱,柱温设置为40℃,流动相分别为0.1%甲酸水溶液和0.1%甲酸甲醇溶液,以0.6 mL/min的流速进行梯度洗脱,质谱采用大气压化学电离正离子MRM模式。结果维生素A、25-OH-D_(2)、25-OH-D_(3)、维生素E和维生素K_(1)在相应浓度范围内线性关系良好,线性相关系数均大于0.998,其日内精密度和日间精密度在1.87%~9.81%,加标回收率在91.47%~107.30%,携带污染率在-6.03%~2.14%,均在可接受范围之内。结论成功建立了LC-MS/MS方法同时测定人血清中维生素A、25-OH-D_(2)、25-OH-D_(3)、维生素E和维生素K_(1)的水平,该方法前处理简便,分析速度快,灵敏度高,专属性强且各被检测物质的线性关系良好,整个检测过程简单、规范,适合临床血清样品的检测。 展开更多
关键词 维生素A 维生素D 维生素E 维生素K_(1) 液相色谱-串联质谱 定量检测
下载PDF
UPLC-MS/MS法同时测定蛋白饮料和液体调味品中36种防腐剂 被引量:1
13
作者 魏宇涛 温泉 +5 位作者 唐维英 黄璐瑶 余晓琴 杜钢 李澍才 李航 《食品与发酵工业》 CSCD 北大核心 2024年第1期279-285,共7页
采用提取和净化相结合的前处理方式,建立并优化了同时测定蛋白饮料、液体调味品中36种防腐剂的超高效液相色谱-串联质谱检测方法。样品采用饱和NaCl溶液(用磷酸调节pH=3)净化和乙腈-甲醇(9∶1,体积比)(含体积分数为0.2%的甲酸)提取。采... 采用提取和净化相结合的前处理方式,建立并优化了同时测定蛋白饮料、液体调味品中36种防腐剂的超高效液相色谱-串联质谱检测方法。样品采用饱和NaCl溶液(用磷酸调节pH=3)净化和乙腈-甲醇(9∶1,体积比)(含体积分数为0.2%的甲酸)提取。采用C18反向色谱柱进行分离,以甲醇和5 mmol/L乙酸铵为流动相梯度洗脱,采用电喷雾离子源正负离子同时扫描,动态多反应监测模式,基质匹配标准曲线,外标法定量。结果表明,36种防腐剂在1~250 ng/mL线性良好(相关系数≥0.999),方法定量限为0.04~0.2 mg/kg;空白样品不同加标水平下的平均加标回收率为75%~119%;相对标准偏差为0.90%~9.8%。建立的高通量检测方法灵敏、快速,准确度高,操作简便且能有效减少基质干扰、降低检测成本,极大提高多种防腐剂的定性定量检测效率。 展开更多
关键词 防腐剂 蛋白饮料 液体调味品 超高效液相色谱串联质谱 动态多反应监测
下载PDF
QuEChERS-UPLC-MS/MS同时测定畜禽肉中23种驱虫类药物残留量
14
作者 张彤 徐宜宏 +5 位作者 付海滨 刘俊 史喜菊 徐蕾蕊 康明芹 张敏 《饲料工业》 CAS 北大核心 2024年第3期120-126,共7页
研究旨在建立同时检测畜禽肉中多种驱虫类药物的分析方法,通过优化前处理方法和仪器分析条件,建立了分散固相萃取法-超高效液相色谱-串联质谱法(UPLC-MS/MS)同时测定畜禽肉中23种驱虫类药物残留的分析方法,目标物以乙腈提取,分散固相萃... 研究旨在建立同时检测畜禽肉中多种驱虫类药物的分析方法,通过优化前处理方法和仪器分析条件,建立了分散固相萃取法-超高效液相色谱-串联质谱法(UPLC-MS/MS)同时测定畜禽肉中23种驱虫类药物残留的分析方法,目标物以乙腈提取,分散固相萃取法(QuEChERS)净化,用乙腈+0.1%甲酸水作为流动相、UPLC-MS/MS确证检测、外标法定量。结果显示:所建立的方法定量限为0.2~1.0μg/kg,回收率为71.4%~107.5%,相对标准偏差为0.9%~8.8%。表明该方法定量限低,稳定性好,适用于畜禽肉中23种驱虫类药物残留的同时检测。 展开更多
关键词 驱虫药 超高效液相色谱-串联质谱 畜禽肉 药物残留 分散固相萃取法
下载PDF
高通量高效快速净化方法结合UPLC-MS/MS测定粮食中黄曲霉毒素
15
作者 何洁 余婷婷 +8 位作者 梁松 王冰 李鹏 殷果 王炳志 徐梅 马红圳 闫研 严义勇 《中国测试》 CAS 北大核心 2024年第5期62-70,共9页
建立粮食中黄曲霉毒素B1、B2、G1、G2快捷高效的确证检测方法。通过对色谱及质谱分析条件、震荡提取方式、稀释倍数分别优化确定满足黄曲霉毒素B1、B2、G1、G2检测方法的最优条件,同时,开发一款自动过柱仪与快速净化柱配合使用对粮食中... 建立粮食中黄曲霉毒素B1、B2、G1、G2快捷高效的确证检测方法。通过对色谱及质谱分析条件、震荡提取方式、稀释倍数分别优化确定满足黄曲霉毒素B1、B2、G1、G2检测方法的最优条件,同时,开发一款自动过柱仪与快速净化柱配合使用对粮食中杂质进行高通量的高效净化,并采用超高效液相色谱-串联质谱(UPLC-MS/MS)进行检测分析。粮食样品经84%乙腈水溶液提取、Speedy Prep®-Myco1流穿式净化柱净化,使用ACQUITY UPLC BEH C18色谱柱分离,以0.1%甲酸水和乙腈作为流动相进行梯度洗脱,质谱采用电喷雾正离子模式和多反应监测模式(multiple reaction monitoring,MRM)采集信号,外标法定量。对于大米、小黄米、小麦、黄豆、面粉、大麦、黑米、花生、玉米基质,本方法黄曲霉毒素B1、B2、G1、G2的检出限和定量限分别为0.06~0.12μg/kg和0.20~0.40μg/kg,在其线性范围内相关系数R≥0.9993,在0.2、0.4、1、10、20、40μg/kg添加回收率为72.37%~118.4%,相对标准偏差(RSD,n=6)为0.64%~14%,回收率和精密度良好。该方法前处理操作简单、稳定性好,适用于粮食中黄曲霉毒素B1、B2、G1、G2的检测。 展开更多
关键词 黄曲霉毒素 超高效液相色谱-串联质谱 粮食 高通量自动过柱仪 高效前处理
下载PDF
UPLC-MS/MS法检测血浆内源性大麻素在预测先兆流产孕妇妊娠结局中的应用
16
作者 王玉秀 刘立东 郭伟 《现代妇产科进展》 2024年第4期282-286,共5页
目的:研究孕妇外周血内源性大麻素水平周期变化规律,并分析基于孕早期内源性大麻素水平预测先兆流产孕妇妊娠结局的临床应用价值。方法:选择2020年5月至2022年5月在山东第一医科大学第一附属医院产检的1080例孕妇,其中880例孕早期发生... 目的:研究孕妇外周血内源性大麻素水平周期变化规律,并分析基于孕早期内源性大麻素水平预测先兆流产孕妇妊娠结局的临床应用价值。方法:选择2020年5月至2022年5月在山东第一医科大学第一附属医院产检的1080例孕妇,其中880例孕早期发生先兆流产孕妇和200例正常妊娠孕妇,超高效液相色谱串联质谱(UPLC-MS/MS)法检测血中内源性大麻素水平,通过logistic回归分析先兆流产发展为难免流产的风险因素,并用ROC曲线评估孕酮、β-人绒毛膜促性腺激素(β-HCG)、花生四烯酸乙醇胺(AEA)预测先兆流产孕妇妊娠结局的性能。结果:发生难免流产的孕妇外周血AEA平均水平为(3.96±2.04)nmol/L,显著高于持续妊娠孕妇[(2.16±2.00)nmol/L](P<0.001)。年龄、AEA、孕酮、β-HCG、胎龄及阴道流血量是先兆流产发展为难免流产的风险因素(P<0.05)。孕早期内源性大麻素AEA,当阈值为2.565nmol/L时,用于预测先兆流产孕妇妊娠结局的准确率为86.7%,具有最优预测性能。结论:孕妇外周血内源性大麻素AEA水平测定是预测先兆流产患者妊娠结局的有效工具。 展开更多
关键词 超高效液相色谱串联质谱(UPlc-ms/MS) 先兆流产 难免流产 内源性大麻素
下载PDF
SPE-UPLC-MS/MS同时测定食品中24种酸性工业染料
17
作者 闵宇航 刘斯琪 +2 位作者 余晓琴 李澍才 张丽平 《食品工业科技》 CAS 北大核心 2024年第1期284-294,共11页
建立了固相萃取-超高效液相色谱串联质谱法同时测定食品中24种酸性工业染料的分析方法。样品经氨水乙醇溶液(氨水:无水乙醇:水=2:7:1,v/v/v)提取,提取液氮吹浓缩至1 mL,加入10 mL 5%甲醇水溶液,弱阴离子交换固相萃取柱(Agela Cleanert P... 建立了固相萃取-超高效液相色谱串联质谱法同时测定食品中24种酸性工业染料的分析方法。样品经氨水乙醇溶液(氨水:无水乙醇:水=2:7:1,v/v/v)提取,提取液氮吹浓缩至1 mL,加入10 mL 5%甲醇水溶液,弱阴离子交换固相萃取柱(Agela Cleanert PWAX)富集净化,氮吹复溶后,Agilent ZORBAX Eclipse RRHD C_(18)(3.0 mm×150 mm,1.8μm)色谱柱分离,流动相采用乙腈和10 mmol/L乙酸铵溶液进行梯度洗脱,电喷雾离子源负离子进行电离,多反应监测模式(MRM)下测定,外标法定量。结果表明,24种酸性工业染料在20~300 ng/mL范围内,相关系数r均大于0.999;方法检出限为10μg/kg,定量限为25μg/kg;在25、100、250μg/kg三个不同加标水平下的回收率为91.0%~112.7%,相对标准偏差(n=6)为0.42%~4.39%。采用该方法对市售的豆制品、调味品、水产品、肉制品各40批次进行测定,2批次卤肉样品中检出酸性橙Ⅱ,含量分别为138±2.8μg/kg和179±3.7μg/kg;2批次香肠样品中检出红2G,含量分别为320±8.6μg/kg和230±6.2μg/kg。该方法灵敏、快速、准确,适用于食品中24种酸性工业染料的定性定量测定。 展开更多
关键词 酸性工业染料 固相萃取(SPE) 超高效液相色谱-串联质谱(UPlc-ms/MS) 豆制品 调味品 水产品 肉制品
下载PDF
Determination of Ten Kinds of Alpha-2 Agonists Residues in Animal Derived Food by UHPLC-Triple Quadrupole/Composite Linear Ion Trap Mass Spectrometry
18
作者 Fang LI Xuemei LI +3 位作者 Xiangang LI Sining LIU Sha LIU Ying WANG 《Plant Diseases and Pests》 2024年第1期28-32,共5页
[Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived f... [Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived food.[Methods]The samples were extracted with sodium carbonate buffer solution and ethyl acetate,and analyzed by mass spectrometry after solid phase extraction and high performance liquid chromatography separation.[Results]Ten kinds ofα2-receptor agonists showed a good linear relationship in the range of 1-100μg/mL,with the average recovery of over 69%and the relative standard deviation less than 8.32%.The detection limit of 10 kinds of α_(2)-receptor agonists was up to 1μg/kg.[Conclusions]The method has good selectivity and strong anti-interference ability,and can meet the requirements of 10 kinds ofα2-receptor agonists residues in animal derived food. 展开更多
关键词 Animal derived food α_(2)-receptor agonist Solid-phase extraction Ultra-high performance liquid phase-triple quadrupole/linear ion trap composite mass spectrometry
下载PDF
改进的QuEChERS结合HPLC-MS/MS快速测定土壤中硝基酚类化合物
19
作者 崔君 《化学研究与应用》 CAS 北大核心 2024年第4期905-909,共5页
本文提出了土壤样品改进的QuEChERS萃取前处理方法,并结合液相色谱-质谱法测定土壤中4种酚类化合物(4-硝基酚,2,4-二硝基酚,2,6-二硝基酚,2,4,6-三硝基酚)含量的方法。1 g土壤样品,置于15ml塑料离心管中,加入2 mL纯水浸润30 min,后加入2... 本文提出了土壤样品改进的QuEChERS萃取前处理方法,并结合液相色谱-质谱法测定土壤中4种酚类化合物(4-硝基酚,2,4-二硝基酚,2,6-二硝基酚,2,4,6-三硝基酚)含量的方法。1 g土壤样品,置于15ml塑料离心管中,加入2 mL纯水浸润30 min,后加入2 mL甲醇,室温下涡旋3 min,后使混合液以4000 r·mi^(-1)的转速离心3 min。取1 mL上层清液,用0.22μm滤膜过滤后直接上机检测,使用多反应监测(MRM)模式检测,电喷雾电离源负离子模式(ESI-),外标法定量。实验结果表明,4种硝基酚类化合物在2.0~100.0μg·L^(-1)的浓度范围的线性相关系数均大于0.998;方法检出限(MDL)为1.76~4.19μg·kg^(-1);以实际土样为基体,加入低中高3个浓度水平的标准溶液进行加标回收试验,加标回收率在85.6%~112%,相对标准偏差(n=6)在1.46~6.86%之间。 展开更多
关键词 硝基酚类化合物 液相色谱-质谱法 QUECHERS
下载PDF
Research on the Upper Limit of Accuracy for Predicting Theoretical Tandem Mass Spectrometry
20
作者 Changjiu He Xiaoyu Wang +1 位作者 Mingming Lyu Xinye Bian 《Journal of Computer and Communications》 2024年第3期184-195,共12页
In recent years, numerous theoretical tandem mass spectrometry prediction methods have been proposed, yet a systematic study and evaluation of their theoretical accuracy limits have not been conducted. If the accuracy... In recent years, numerous theoretical tandem mass spectrometry prediction methods have been proposed, yet a systematic study and evaluation of their theoretical accuracy limits have not been conducted. If the accuracy of current methods approaches this limit, further exploration of new prediction techniques may become redundant. Conversely, a need for more precise prediction methods or models may be indicated. In this study, we have experimentally analyzed the limits of accuracy at different numbers of ions and parameters using repeated spectral pairs and integrating various similarity metrics. Results show significant achievements in accuracy for backbone ion methods with room for improvement. In contrast, full-spectrum prediction methods exhibit greater potential relative to the theoretical accuracy limit. Additionally, findings highlight the significant impact of normalized collision energy and instrument type on prediction accuracy, underscoring the importance of considering these factors in future theoretical tandem mass spectrometry predictions. 展开更多
关键词 Tandem mass spectrometry Spectral Prediction Theoretical Limit
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部