期刊文献+
共找到77篇文章
< 1 2 4 >
每页显示 20 50 100
Measurement of mass attenuation coefficients,effective atomic numbers,and electron densities for different parts of medicinal aromatic plants in low-energy region 被引量:6
1
作者 M.I.Sayyed F.Akman +1 位作者 I.H.Geccbesler H.O.Tekin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第10期200-209,共10页
The mass attenuation coefficients(l/q) for different parts(root, flower, stem, and leaf) of three medicinal aromatic plants(Teucrium chamaedrys L. subsp. sinuatum,Rheum ribes, and Chrysophthalmum montanum) were measur... The mass attenuation coefficients(l/q) for different parts(root, flower, stem, and leaf) of three medicinal aromatic plants(Teucrium chamaedrys L. subsp. sinuatum,Rheum ribes, and Chrysophthalmum montanum) were measured using an ^(241)Am photon source in a stable geometry and calculated using the Monte Carlo N-Particle Transport Code System-extended(MCNPX) code and the WinXCOM program. The experimental and theoretical MCNPX and WinXCOM values exhibited good agreement.The measured mass attenuation coefficient values were then used to compute the effective atomic number(Z_(eff))and electron density(N_E) of the samples. The results reveal that S1-S(stem of Teucrium chamaedrys L. subsp. sinuatum) has the highest values of l/q and Zeff. 展开更多
关键词 MEDICINAL AROMATIC plant MCNPX code mass attenuation coefficient PHOTON WinXCOM
下载PDF
Pocket formula for mass attenuation coefficient, effective atomic number, and electron density of human tissues 被引量:1
2
作者 H.C.Manjunatha L.Seenappa 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期1-8,共8页
We have proposed a pocket formula for mass attenuation coefficient(μ/ρ), mass energy absorption coefficient(μ_(en)/ρ), and effective atomic number(Z_(eff)) in different tissues of human organs. We have also assign... We have proposed a pocket formula for mass attenuation coefficient(μ/ρ), mass energy absorption coefficient(μ_(en)/ρ), and effective atomic number(Z_(eff)) in different tissues of human organs. We have also assigned a new chemical formula for all studied tissues based on their composition. We have introduced a new parameter called effective composition index(C_(eff)). Based on this, we have introduced a new method to compute the effective atomic number. The evaluated photon interaction parameters are graphically represented. The evaluated average, maximum,minimum, and standard deviations of effective atomic number are tabulated. The proposed formula produces a mass attenuation coefficient, mass energy absorption coefficient, and effective atomic number from their 展开更多
关键词 Effective ATOMIC number mass attenuation coefficient TISSUES
下载PDF
A comprehensive study for mass attenuation coefficients of different parts of the human body through Monte Carlo methods 被引量:3
3
作者 E.E.Ermis F.B.Pilicer +1 位作者 E.Pilicer C.Celiktas 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第3期31-39,共9页
The gamma-ray mass attenuation coefficients of blood,bone,lung,eye lens,adipose,tissue,muscle,brain and skin were calculated at different energies(60,80,150,400,500,600,1000,1250,1500,and 2000 keV) by various theoreti... The gamma-ray mass attenuation coefficients of blood,bone,lung,eye lens,adipose,tissue,muscle,brain and skin were calculated at different energies(60,80,150,400,500,600,1000,1250,1500,and 2000 keV) by various theoretical methods such as FLUKA,GEANT4 Monte Carlo(MC) methods and XCOM program in this work.Calculated coefficients were also compared with the National Institute of Standards and Technology(NIST) values.Obtained results were highly in accordance with each other and NIST values.Our results showed that FLUKA was quite convenient in comparison to GEANT4 in the calculation of the mass attenuation coefficients of the used human body samples for low-energy photons(60,80,and 150 keV) when compared with the NIST values. 展开更多
关键词 质量衰减系数 蒙特卡洛方法 GEANT4 部位 NIST 美国国家标准 能量计算 眼晶状体
下载PDF
Studies on mass attenuation coefficients for some body tissues with different medical sources and their validation using Monte Carlo codes
4
作者 Sepideh Yazdani Darki Sajad Keshavarz 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2020年第12期50-64,共15页
The mass attenuation coefficients of the breasts,lungs,kidneys,pancreas,liver,eye lenses,thyroid,brain,ovary,heart,large intestines,blood,skin,spleen,muscle,and cortical bone were measured at different sources(i.e.,0.... The mass attenuation coefficients of the breasts,lungs,kidneys,pancreas,liver,eye lenses,thyroid,brain,ovary,heart,large intestines,blood,skin,spleen,muscle,and cortical bone were measured at different sources(i.e.,0.021,0.029,0.03,0.14,0.218,0.38,0.412,0.663,0.83,and 1.25 MeV)using various methods including the Monte Carlo N-particle transport code(MCNP),the geometry and tracking code(GEANT4),and theoretical approach described in this study.Mass attenuation coefficients were also compared with the values from the national institute of standards and technology(NIST-XCOM).The values obtained were similar to those obtained using NISTXCOM.Our results show that the theoretical method is quite convenient in comparison with GEANT4 and MCNP in the calculation of the mass attenuation coefficients of the human body samples applied when compared with the NIST values and demonstrated an acceptable difference. 展开更多
关键词 mass attenuation coefficient MCNP GEANT4 XCOM Human organs
下载PDF
Effect of Gamma Ray Energies and Addition of Iron Slag by weight to Portland Cements on Mass Attenuation Coefficient
5
作者 Abd El-LatifAbd EI-Ghany Abd EI-LatifAhmed Khalifa S. Saeid +1 位作者 H.S. Ragab A.A. Abdalla 《材料科学与工程(中英文A版)》 2013年第12期838-842,共5页
关键词 质量衰减系数 波特兰水泥 伽玛射线 铁渣 射线能量 重量 理论计算值 γ射线谱仪
下载PDF
Study the Attenuation Coefficient of Granite to Use It as Shields against Gamma Ray
6
作者 Laith Ahmed Najam Abdalsattar Kareem Hashim +1 位作者 Hussein Abdulkareem Ahmed Israa M. Hassan 《Detection》 2016年第2期33-39,共7页
The present work investigates the linear and mass attenuation coefficients for gamma rays practically and theoretically by using spectroscopy gamma ray (UCS-20) and program (XCOM)) for various types of common use gran... The present work investigates the linear and mass attenuation coefficients for gamma rays practically and theoretically by using spectroscopy gamma ray (UCS-20) and program (XCOM)) for various types of common use granite, and compares them with the lead because of its high blocking ability for this type of radiation. This paper concluded through linear and mass attenuation coefficients measurements that these coefficients decrease with increasing incident photons energy. Measurements also showed that the linear attenuation coefficients appropriate linearly with density while mass attenuation coefficients do not get affected. 展开更多
关键词 Gamma Rays attenuation coefficient (Linear and mass) Building Materials Sodium Iodide Detector
下载PDF
舰船舱室的早期伽马辐射屏蔽特性
7
作者 柴辰睿 郝建红 +4 位作者 张芳 赵强 范杰清 董志伟 薛碧曦 《强激光与粒子束》 CAS CSCD 北大核心 2024年第4期207-214,共8页
利用蒙特卡罗方法对早期核辐射场景下的舰船舱室屏蔽特性进行研究。使用早期伽马辐射作为辐射源,测定了舰船主体常用的HSLA-80、5456Al及FDCL-3B三种材料的质量衰减系数,并根据舰船的几何结构建立了模拟舱室模型,采用高斯展宽方法对探... 利用蒙特卡罗方法对早期核辐射场景下的舰船舱室屏蔽特性进行研究。使用早期伽马辐射作为辐射源,测定了舰船主体常用的HSLA-80、5456Al及FDCL-3B三种材料的质量衰减系数,并根据舰船的几何结构建立了模拟舱室模型,采用高斯展宽方法对探测器的能谱拟合处理,得到了伽马辐射下舱室内部NaI探测器的吸收能谱,并与文献中的实验结果进行了对比,验证了计算模型和计算结果的可靠性。在此基础上,以伽马防护系数为评价指标,考虑放射性同位素(单能点源)和早期伽马辐射(具有能量分布的面源)两种场景,计算分析了模拟舱室伽马辐射屏蔽的空间分布特性,结果表明:模拟舱室对不同放射性同位素的防护系数是不同的,最多可相差6.74倍(Cd-109与Cs-137);舱室不同位置的防护系数不同。舱室前端的伽马辐射剂量较大,而角落的伽马辐射剂量较小,相差35%;防护系数与伽马辐照的入射角度有关。与正入射相比,模拟舱室对斜45°入射的伽马辐射防护系数更高,可提升43%。 展开更多
关键词 质量衰减系数 船舶舱室 伽马辐射 伽马防护系数
下载PDF
Zn吸收边附近质量衰减系数测量
8
作者 舒子瑶 郭思明 +4 位作者 周幸 黄仕葵 樊丽鹏 李知微 王振 《计量学报》 CSCD 北大核心 2024年第8期1231-1235,共5页
物质材料的光子质量衰减系数的准确值可为不同领域提供基本数据。由于单能X射线辐射装置能量连续可调、光子数可测,产生的X射线单能窄束,使其成为研究质量衰减系数(μ/ρ)的理想器件。研究了在8~20 keV能量范围内,Zn样品在K吸收边附近(9... 物质材料的光子质量衰减系数的准确值可为不同领域提供基本数据。由于单能X射线辐射装置能量连续可调、光子数可测,产生的X射线单能窄束,使其成为研究质量衰减系数(μ/ρ)的理想器件。研究了在8~20 keV能量范围内,Zn样品在K吸收边附近(9~11 keV),以0.1 keV步长,基于单能X射线装置的质量衰减系数测量方法,并利用实验得到的测量值与NIST理论值进行比较分析。结果表明,在K吸收边跳跃附近会产生1个最大偏差,偏差在远离吸收边时会减小。实测曲线与NIST-XCOM及NIST-FFAST曲线基本一致,测量值与NIST-XCOM理论值最大偏差不超过10.51%。 展开更多
关键词 电离辐射计量 质量衰减系数 吸收边 单能X射线
下载PDF
Study on gamma-ray attenuation characteristics of some amino acids for 133Ba,137Cs, and 60Co sources 被引量:1
9
作者 Reza Bagheri Ali Yousefi Seyed Pezhman Shirmardi 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第2期67-81,共15页
Amino acids are the building blocks of proteins,which are the most abundant macromolecules in living cells.From the standpoint of the photon interaction cross sections of amino acids,the mass attenuation coefficients,... Amino acids are the building blocks of proteins,which are the most abundant macromolecules in living cells.From the standpoint of the photon interaction cross sections of amino acids,the mass attenuation coefficients,half and tenth value layers,mean free path,effective atomic and electronic cross sections,effective atomic number,and effective electron density of fifteen essential amino acids have been determined for 133Ba,137Cs,and 60Co gamma-ray sources.The MCNP-4C code and the XCOM program have been used to calculate these parameters.The results have been compared to the available experimental and theoretical data.The theoretical results agreed with the experimental data,with RD values of ≤±7%.In the energy region of 81-1332.5 keV,it was found that the μm,σa,and revalues of the amino acids decreased as the photon energy increased,and the increasing density of amino acids had no steady effect on these quantities.Additionally,results demonstrated that the HVL,TVL,and MFP values increased with the increase in photon energy.The μm,σa,and Zeff values of aspartic acid were the highest among those of all amino acids,and they were the lowest for isoleucine.The Zeff value of each sample containing H,C,N,and O atoms was nearly constant in the studied energy region.The Neffvalues of the studied amino acids varied in the range of 3.14×10^23-3.44×10^23 electron/g.Furthermore,the Neffvalues were approximately independent of the amino acid type in this energy region. 展开更多
关键词 Amino acids mass attenuation coefficient Effective electron density and atomic number MCNP-4C XCOM
下载PDF
Temperature Dependence of Density and Thermal Expansion of Wrought Aluminum Alloys 7041, 7075 and 7095 by Gamma Ray Attenuation Method 被引量:1
10
作者 Kethireddy Narender Ammiraju Sowbhagya Madhusudhan Rao +1 位作者 Kalvala Gopal Kishan Rao Nallacheruvu Gopi Krishna 《Journal of Modern Physics》 2013年第3期331-336,共6页
The gamma quanta attenuation studies have been carried out to determine mass attenuation coefficients of 7041, 7075 and 7095 wrought aluminum alloys. The temperature dependence of linear attenuation coefficient, densi... The gamma quanta attenuation studies have been carried out to determine mass attenuation coefficients of 7041, 7075 and 7095 wrought aluminum alloys. The temperature dependence of linear attenuation coefficient, density and thermal expansion of these wrought aluminum alloys in the temperature range 300 K - 850 K have been reported. The measurements were done by using a gamma ray densitometer designed and fabricated in our laboratory. The data on variation of density and linear thermal expansion with temperature have been represented by linear equations. Volume thermal expansion coefficients have been reported. 展开更多
关键词 DENSITY Thermal EXPANSION LINEAR attenuation coefficient mass attenuation coefficient
下载PDF
Characteristics of water masses and bio-optical properties of the Bering Sea shelf during 2007–2009
11
作者 Yubin Yao Tao Li +1 位作者 Xingyuan Zhu Xiaoyu Wang 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2022年第10期140-153,共14页
The hydrographic and bio-optical properties of the Bering Sea shelf were analyzed based on in-situ measurements obtained during four cruises from 2007 to 2009.According to the temperature and salinity of the seawater,... The hydrographic and bio-optical properties of the Bering Sea shelf were analyzed based on in-situ measurements obtained during four cruises from 2007 to 2009.According to the temperature and salinity of the seawater,the spring water masses on the Bering Sea shelf were classified as the Alaskan Coast Water,Bering Sea Shelf Water,Anadyr Water,Spring Mixed Layer Water,Remnant Winter Water,and Winter Water,each of which had varying chlorophyll a concentrations.Among them,the highest chlorophyll a concentration occurred in the nutrient-rich Anadyr Water((7.57±6.16)mg/m^(3) in spring).The spectrum-dependent diffuse attenuation coefficient(Kd(λ))of the water column for downwelling irradiance was also calculated,exhibiting a decrease at 412-555 nm and then an increase within the range of 0.17-0.48 m-1in spring.Furthermore,a strong correlation between the chlorophyll a concentration and the attenuation coefficient was found at visible wavelengths on the Bering Sea shelf.Spatially,the chlorophyll a concentration was higher on the northern shelf((5.18±3.78)mg/m^(3))than on the southern shelf((3.64±2.51)mg/m^(3)),which was consistent with the distribution of the attenuation coefficient.Seasonally,the consumption of nutrients by blooms resulted in minimum chlorophyll a concentration((0.78±0.51)mg/m^(3))and attenuation coefficient values in summer.In terms of the vertical structure,both the attenuation coefficient and the chlorophyll a concentration tended to reach maximum values at the same depth,and the depth of the maximum values increased as the surface temperature increased in summer.Moreover,an empirical model was fitted with a power function based on the correlation between the chlorophyll a concentration and the attenuation coefficient at 412-555 nm.In addition,a spectral model was constructed according to the relationship between the attenuation coefficients at 490 nm and at other wavelengths,which provides a method for estimating the bio-optical properties of the Bering Sea shelf. 展开更多
关键词 diffuse attenuation coefficient water mass Bering Sea shelf chlorophyll a empirical model
下载PDF
HXCF测量医用辐射模体的质量衰减系数 被引量:1
12
作者 郭锴悦 赵天琦 +4 位作者 郭思明 蒋政 郄晓雨 余涛 吴金杰 《计量学报》 CSCD 北大核心 2023年第4期616-621,共6页
质量衰减系数是X射线分析中的1个重要物理量,是目前最常用的辐射特性表征参数。硬X射线地面标定装置(hard X-ray calibration facility,HXCF)能为质量衰减系数的测量提供“单能、窄束”的实验条件,是研究质量衰减系数的理想装置。实验... 质量衰减系数是X射线分析中的1个重要物理量,是目前最常用的辐射特性表征参数。硬X射线地面标定装置(hard X-ray calibration facility,HXCF)能为质量衰减系数的测量提供“单能、窄束”的实验条件,是研究质量衰减系数的理想装置。实验利用硬X射线地面标定装置,在40~80 keV能量范围内测定聚四氟乙烯(Poly tetra fluoroethylene,PTFE)和有机玻璃(Polymethyl methacrylate,PMMA)2种医用模体材料的质量衰减系数,并将测量得到的质量衰减系数与NIST数据库中的参考值进行对比,分析实验值与理论值的相对偏差。结果表明,2种材料的质量衰减系数曲线与理论值的变化趋势是一致的。其中,PTFE的测量值与理论值的最大相对偏差为5.274%@47 keV,PMMA的测量值与理论值的最大相对偏差为6.303%@51 keV。 展开更多
关键词 计量学 X射线 质量衰减系数 硬X射线地面标定装置 医用模体材料
下载PDF
用于XTES的铋吸收体对单色X射线的响应研究
13
作者 舒子瑶 郭思明 +7 位作者 蒋政 郄晓雨 郭锴悦 黄仕葵 赖万昌 周幸 樊丽鹏 余涛 《核电子学与探测技术》 CAS 北大核心 2023年第5期1030-1036,共7页
超导转变边缘探测器(TES)是目前为止已知的具有最佳的能量分辨率的X射线探测器。金属Bi因其具有较好的X射线吸收率和低比热容而被广泛用于XTES的吸收体。通过电镀的方法制备了一种由Bi构成的XTES吸收体薄膜,使用Ti和Au作为导电层在Si上... 超导转变边缘探测器(TES)是目前为止已知的具有最佳的能量分辨率的X射线探测器。金属Bi因其具有较好的X射线吸收率和低比热容而被广泛用于XTES的吸收体。通过电镀的方法制备了一种由Bi构成的XTES吸收体薄膜,使用Ti和Au作为导电层在Si上提供电流通路。研究了电镀法制备Bi金属XTES吸收体对单能X射线的吸收效率,使用高纯锗探测器测量通过吸收材料前后的单能X射线光子数,以全能峰面积衡量不同厚度电镀Bi吸收体对单能X射线的吸收效率。研究结果对促进先进探测器的国产化具有重要意义。 展开更多
关键词 单能X射线 TES吸收体 电镀Bi膜 布拉格衍射
下载PDF
基于GEANT4模拟含铋辐射防护材料制备及性能研究
14
作者 朱杰辉 郭滢 姚理荣 《纺织报告》 2023年第12期28-32,共5页
基于GEANT4软件,采用蒙特卡罗方法设计了一种柔性、轻质、无铅的含铋辐射防护面料。建立仿真模型,研究了铋粉质量分数、铋粉粒径对防护材料辐射防护性能的影响,并与实际制备结果进行比较,发现铋元素可以大大提高防护材料的辐射防护效率... 基于GEANT4软件,采用蒙特卡罗方法设计了一种柔性、轻质、无铅的含铋辐射防护面料。建立仿真模型,研究了铋粉质量分数、铋粉粒径对防护材料辐射防护性能的影响,并与实际制备结果进行比较,发现铋元素可以大大提高防护材料的辐射防护效率,当铋粉的质量分数为70.0%、铋粉粒径为1μm、涂层厚度为400μm时,防护面料的辐射防护性能较为优异。 展开更多
关键词 蒙特卡罗方法 吸收弱区 辐射防护材料 质量衰减系数
下载PDF
γ射线衰减法测量混相密度 被引量:15
15
作者 魏伟胜 赵志学 鲍晓军 《过程工程学报》 CAS CSCD 北大核心 2003年第6期512-517,共6页
对射线的衰减规律提出了一个修正的质量吸收系数μ'm.测量系统的响应频率偏低而射线强度又较大,或者射线强度较小时(<100 Bq),射线强度将明显影响μ'm.待测物体离探头相对位置越近时,物体对射线的μ'm越小.物体在探头和射... 对射线的衰减规律提出了一个修正的质量吸收系数μ'm.测量系统的响应频率偏低而射线强度又较大,或者射线强度较小时(<100 Bq),射线强度将明显影响μ'm.待测物体离探头相对位置越近时,物体对射线的μ'm越小.物体在探头和射线源之间的中部(相对位置在20%~80%),位置对μ'm的影响较小.实验还发现μ'm几乎与物体的厚度和状态无关.采用GTS-2000系统既能测量射线强度,又能测量射线能谱,借助能谱可直观地选定单能峰值γ射线所在的上下阈值,有助于提高测量系统的稳定性. 展开更多
关键词 射线衰减规律 质量吸收系数 混相密度 测量精度 γ射线衰减法
下载PDF
同步辐射单能X射线空气质量衰减系数的测量 被引量:14
16
作者 杜海燕 李凡 +4 位作者 吴金杰 王培玮 赖万昌 王继 赵屹东 《计量学报》 CSCD 北大核心 2019年第2期333-336,共4页
介绍了3种X射线空气质量衰减系数的测量方法:移动距离法、抽真空法、EGSnrc蒙特卡罗模拟计算法。给出了抽真空法中真空管内空气质量厚度改变量的计算公式,并模拟分析了真空管Be窗对实验的影响。移动距离法与抽真空法得到的结果较接近,... 介绍了3种X射线空气质量衰减系数的测量方法:移动距离法、抽真空法、EGSnrc蒙特卡罗模拟计算法。给出了抽真空法中真空管内空气质量厚度改变量的计算公式,并模拟分析了真空管Be窗对实验的影响。移动距离法与抽真空法得到的结果较接近,验证了抽真空法实验的合理性。当X射线能量为6 ke V、20 ke V时,EGSnrc蒙特卡罗模拟计算结果与NIST标准数据库数值偏差分别为0. 01%、0. 26%。 展开更多
关键词 计量学 空气质量衰减系数 抽真空法 移动距离法 蒙特卡罗模拟
下载PDF
质量衰减系数的计算与应用 被引量:7
17
作者 眭松山 魏军 史青 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 1996年第2期85-89,共5页
质量衰砬系数μm是X射线理论强度计算中一项必需而重要的基本参数。它包括元素本身、元素间和元素对某波长的质量吸收。本文选用四种拟合式,用C语言编制成程序;任选波长计算与实验值进行比较,确定其精确度,提供给FP法计算初级... 质量衰砬系数μm是X射线理论强度计算中一项必需而重要的基本参数。它包括元素本身、元素间和元素对某波长的质量吸收。本文选用四种拟合式,用C语言编制成程序;任选波长计算与实验值进行比较,确定其精确度,提供给FP法计算初级和次级激发理论强度。 展开更多
关键词 质量衰减系数 基本参数法 X-射线荧光
下载PDF
超声波速度测定中影响因素的实验研究 被引量:6
18
作者 赵闯 李成波 +1 位作者 杨映希 施行觉 《地球物理学进展》 CSCD 北大核心 2011年第6期2232-2240,共9页
超声波测波速时,会受到样品长度、换能器频率、信号放大倍数以及耦合剂和耦合力等因素影响.为了定量地了解这些因素对测量结果的影响,本文用550 KHz、50 KHz二种频率换能器测量了近百块不同长度、空气干燥样品的波速.发现波速随长度的... 超声波测波速时,会受到样品长度、换能器频率、信号放大倍数以及耦合剂和耦合力等因素影响.为了定量地了解这些因素对测量结果的影响,本文用550 KHz、50 KHz二种频率换能器测量了近百块不同长度、空气干燥样品的波速.发现波速随长度的增加由一维"杆"中的波速逐渐增大并稳定在三维"无限大"中的波速,在此过程中长度对550 KHz波速变化的影响要小于50 KHz;一定长度后,频散趋于稳定且与样品Q值有关;波速随信号放大倍数、耦合剂的使用及耦合强度增大而增大.实验数据与波动理论、波速频散公式相符合.利用结果对Q<30的样品用频散法进行了Q测量,与频谱振幅比法结果有1%~11%相差;对地震仪和声波仪频率下测得的岩体完整性系数频散修正后二者平均相差由8%降到1.4%. 展开更多
关键词 超声波速度 频散 衰减 岩体完整性系数
下载PDF
蒙特卡罗方法计算介质对窄束γ射线的质量衰减系数 被引量:7
19
作者 李丹 赖万昌 +1 位作者 王广西 郭伟 《核电子学与探测技术》 CAS CSCD 北大核心 2007年第2期415-417,共3页
根据γ光子与物质的作用机理,对γ光子在介质中反应轨迹进行抽样跟踪,以此建立基于蒙特卡罗方法的粒子输运数学模型。利用虚拟仪器开发工具LabWindows/CVI编制软件模拟γ光子在介质中的输运过程,根据粒子出射率及对应的吸收介质厚度,计... 根据γ光子与物质的作用机理,对γ光子在介质中反应轨迹进行抽样跟踪,以此建立基于蒙特卡罗方法的粒子输运数学模型。利用虚拟仪器开发工具LabWindows/CVI编制软件模拟γ光子在介质中的输运过程,根据粒子出射率及对应的吸收介质厚度,计算介质对窄束γ射线的质量衰减系数。结果显示用蒙特卡罗方法计算介质对窄束γ射线的质量衰减系数是可行的。 展开更多
关键词 蒙特卡罗方法 粒子输运 质量衰减系数 LABWINDOWS/CVI
下载PDF
完整岩体对测井频率应力波的滤波特性 被引量:4
20
作者 王观石 胡世丽 +1 位作者 李志文 王星光 《振动与冲击》 EI CSCD 北大核心 2014年第23期127-132,154,共7页
不同频率范围内的应力波在岩体的传播过程中,衰减系数对频率的依赖性具有显著差异。通过现场试验研究完整岩体对测井频率范围内应力波的滤波特性,针对常用黏弹性模型在描述衰减系数与频率关系存在不足,在频域上对黏性系数进行非定常处理... 不同频率范围内的应力波在岩体的传播过程中,衰减系数对频率的依赖性具有显著差异。通过现场试验研究完整岩体对测井频率范围内应力波的滤波特性,针对常用黏弹性模型在描述衰减系数与频率关系存在不足,在频域上对黏性系数进行非定常处理,建立黏性系数非定常Maxwell模型,采用波形相关系数评价改进模型的滤波效果。研究结果表明,完整岩体总体上表现为低通滤波,在低通滤波范围内具有非等间距带通滤波特性,随传播距离增加,带通数逐渐减小;在吸收频率过渡带,应力波衰减系数随频率变化非常快,黏性系数非定常Maxwell模型能够有效描述应力波在完整岩体中的衰减系数变化规律;吸收频率过渡带的边界频率与传播距离成负指数关系,吸收频率过渡带的陡度参数可以近似认为是常数;随传播距离增加,黏性系数非定常Maxwell模型描述完整岩体的滤波效果明显提高,当传播距离为4.75m时,波形相关系数达到0.89,表明采用改进模型描述完整岩体是有效的。 展开更多
关键词 完整岩体 滤波特性 Maxwell模型 应力波 衰减系数
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部