The mass attenuation coefficients(l/q) for different parts(root, flower, stem, and leaf) of three medicinal aromatic plants(Teucrium chamaedrys L. subsp. sinuatum,Rheum ribes, and Chrysophthalmum montanum) were measur...The mass attenuation coefficients(l/q) for different parts(root, flower, stem, and leaf) of three medicinal aromatic plants(Teucrium chamaedrys L. subsp. sinuatum,Rheum ribes, and Chrysophthalmum montanum) were measured using an ^(241)Am photon source in a stable geometry and calculated using the Monte Carlo N-Particle Transport Code System-extended(MCNPX) code and the WinXCOM program. The experimental and theoretical MCNPX and WinXCOM values exhibited good agreement.The measured mass attenuation coefficient values were then used to compute the effective atomic number(Z_(eff))and electron density(N_E) of the samples. The results reveal that S1-S(stem of Teucrium chamaedrys L. subsp. sinuatum) has the highest values of l/q and Zeff.展开更多
We have proposed a pocket formula for mass attenuation coefficient(μ/ρ), mass energy absorption coefficient(μ_(en)/ρ), and effective atomic number(Z_(eff)) in different tissues of human organs. We have also assign...We have proposed a pocket formula for mass attenuation coefficient(μ/ρ), mass energy absorption coefficient(μ_(en)/ρ), and effective atomic number(Z_(eff)) in different tissues of human organs. We have also assigned a new chemical formula for all studied tissues based on their composition. We have introduced a new parameter called effective composition index(C_(eff)). Based on this, we have introduced a new method to compute the effective atomic number. The evaluated photon interaction parameters are graphically represented. The evaluated average, maximum,minimum, and standard deviations of effective atomic number are tabulated. The proposed formula produces a mass attenuation coefficient, mass energy absorption coefficient, and effective atomic number from their展开更多
The gamma-ray mass attenuation coefficients of blood,bone,lung,eye lens,adipose,tissue,muscle,brain and skin were calculated at different energies(60,80,150,400,500,600,1000,1250,1500,and 2000 keV) by various theoreti...The gamma-ray mass attenuation coefficients of blood,bone,lung,eye lens,adipose,tissue,muscle,brain and skin were calculated at different energies(60,80,150,400,500,600,1000,1250,1500,and 2000 keV) by various theoretical methods such as FLUKA,GEANT4 Monte Carlo(MC) methods and XCOM program in this work.Calculated coefficients were also compared with the National Institute of Standards and Technology(NIST) values.Obtained results were highly in accordance with each other and NIST values.Our results showed that FLUKA was quite convenient in comparison to GEANT4 in the calculation of the mass attenuation coefficients of the used human body samples for low-energy photons(60,80,and 150 keV) when compared with the NIST values.展开更多
The mass attenuation coefficients of the breasts,lungs,kidneys,pancreas,liver,eye lenses,thyroid,brain,ovary,heart,large intestines,blood,skin,spleen,muscle,and cortical bone were measured at different sources(i.e.,0....The mass attenuation coefficients of the breasts,lungs,kidneys,pancreas,liver,eye lenses,thyroid,brain,ovary,heart,large intestines,blood,skin,spleen,muscle,and cortical bone were measured at different sources(i.e.,0.021,0.029,0.03,0.14,0.218,0.38,0.412,0.663,0.83,and 1.25 MeV)using various methods including the Monte Carlo N-particle transport code(MCNP),the geometry and tracking code(GEANT4),and theoretical approach described in this study.Mass attenuation coefficients were also compared with the values from the national institute of standards and technology(NIST-XCOM).The values obtained were similar to those obtained using NISTXCOM.Our results show that the theoretical method is quite convenient in comparison with GEANT4 and MCNP in the calculation of the mass attenuation coefficients of the human body samples applied when compared with the NIST values and demonstrated an acceptable difference.展开更多
The present work investigates the linear and mass attenuation coefficients for gamma rays practically and theoretically by using spectroscopy gamma ray (UCS-20) and program (XCOM)) for various types of common use gran...The present work investigates the linear and mass attenuation coefficients for gamma rays practically and theoretically by using spectroscopy gamma ray (UCS-20) and program (XCOM)) for various types of common use granite, and compares them with the lead because of its high blocking ability for this type of radiation. This paper concluded through linear and mass attenuation coefficients measurements that these coefficients decrease with increasing incident photons energy. Measurements also showed that the linear attenuation coefficients appropriate linearly with density while mass attenuation coefficients do not get affected.展开更多
Amino acids are the building blocks of proteins,which are the most abundant macromolecules in living cells.From the standpoint of the photon interaction cross sections of amino acids,the mass attenuation coefficients,...Amino acids are the building blocks of proteins,which are the most abundant macromolecules in living cells.From the standpoint of the photon interaction cross sections of amino acids,the mass attenuation coefficients,half and tenth value layers,mean free path,effective atomic and electronic cross sections,effective atomic number,and effective electron density of fifteen essential amino acids have been determined for 133Ba,137Cs,and 60Co gamma-ray sources.The MCNP-4C code and the XCOM program have been used to calculate these parameters.The results have been compared to the available experimental and theoretical data.The theoretical results agreed with the experimental data,with RD values of ≤±7%.In the energy region of 81-1332.5 keV,it was found that the μm,σa,and revalues of the amino acids decreased as the photon energy increased,and the increasing density of amino acids had no steady effect on these quantities.Additionally,results demonstrated that the HVL,TVL,and MFP values increased with the increase in photon energy.The μm,σa,and Zeff values of aspartic acid were the highest among those of all amino acids,and they were the lowest for isoleucine.The Zeff value of each sample containing H,C,N,and O atoms was nearly constant in the studied energy region.The Neffvalues of the studied amino acids varied in the range of 3.14×10^23-3.44×10^23 electron/g.Furthermore,the Neffvalues were approximately independent of the amino acid type in this energy region.展开更多
The gamma quanta attenuation studies have been carried out to determine mass attenuation coefficients of 7041, 7075 and 7095 wrought aluminum alloys. The temperature dependence of linear attenuation coefficient, densi...The gamma quanta attenuation studies have been carried out to determine mass attenuation coefficients of 7041, 7075 and 7095 wrought aluminum alloys. The temperature dependence of linear attenuation coefficient, density and thermal expansion of these wrought aluminum alloys in the temperature range 300 K - 850 K have been reported. The measurements were done by using a gamma ray densitometer designed and fabricated in our laboratory. The data on variation of density and linear thermal expansion with temperature have been represented by linear equations. Volume thermal expansion coefficients have been reported.展开更多
The hydrographic and bio-optical properties of the Bering Sea shelf were analyzed based on in-situ measurements obtained during four cruises from 2007 to 2009.According to the temperature and salinity of the seawater,...The hydrographic and bio-optical properties of the Bering Sea shelf were analyzed based on in-situ measurements obtained during four cruises from 2007 to 2009.According to the temperature and salinity of the seawater,the spring water masses on the Bering Sea shelf were classified as the Alaskan Coast Water,Bering Sea Shelf Water,Anadyr Water,Spring Mixed Layer Water,Remnant Winter Water,and Winter Water,each of which had varying chlorophyll a concentrations.Among them,the highest chlorophyll a concentration occurred in the nutrient-rich Anadyr Water((7.57±6.16)mg/m^(3) in spring).The spectrum-dependent diffuse attenuation coefficient(Kd(λ))of the water column for downwelling irradiance was also calculated,exhibiting a decrease at 412-555 nm and then an increase within the range of 0.17-0.48 m-1in spring.Furthermore,a strong correlation between the chlorophyll a concentration and the attenuation coefficient was found at visible wavelengths on the Bering Sea shelf.Spatially,the chlorophyll a concentration was higher on the northern shelf((5.18±3.78)mg/m^(3))than on the southern shelf((3.64±2.51)mg/m^(3)),which was consistent with the distribution of the attenuation coefficient.Seasonally,the consumption of nutrients by blooms resulted in minimum chlorophyll a concentration((0.78±0.51)mg/m^(3))and attenuation coefficient values in summer.In terms of the vertical structure,both the attenuation coefficient and the chlorophyll a concentration tended to reach maximum values at the same depth,and the depth of the maximum values increased as the surface temperature increased in summer.Moreover,an empirical model was fitted with a power function based on the correlation between the chlorophyll a concentration and the attenuation coefficient at 412-555 nm.In addition,a spectral model was constructed according to the relationship between the attenuation coefficients at 490 nm and at other wavelengths,which provides a method for estimating the bio-optical properties of the Bering Sea shelf.展开更多
介绍了3种X射线空气质量衰减系数的测量方法:移动距离法、抽真空法、EGSnrc蒙特卡罗模拟计算法。给出了抽真空法中真空管内空气质量厚度改变量的计算公式,并模拟分析了真空管Be窗对实验的影响。移动距离法与抽真空法得到的结果较接近,...介绍了3种X射线空气质量衰减系数的测量方法:移动距离法、抽真空法、EGSnrc蒙特卡罗模拟计算法。给出了抽真空法中真空管内空气质量厚度改变量的计算公式,并模拟分析了真空管Be窗对实验的影响。移动距离法与抽真空法得到的结果较接近,验证了抽真空法实验的合理性。当X射线能量为6 ke V、20 ke V时,EGSnrc蒙特卡罗模拟计算结果与NIST标准数据库数值偏差分别为0. 01%、0. 26%。展开更多
文摘The mass attenuation coefficients(l/q) for different parts(root, flower, stem, and leaf) of three medicinal aromatic plants(Teucrium chamaedrys L. subsp. sinuatum,Rheum ribes, and Chrysophthalmum montanum) were measured using an ^(241)Am photon source in a stable geometry and calculated using the Monte Carlo N-Particle Transport Code System-extended(MCNPX) code and the WinXCOM program. The experimental and theoretical MCNPX and WinXCOM values exhibited good agreement.The measured mass attenuation coefficient values were then used to compute the effective atomic number(Z_(eff))and electron density(N_E) of the samples. The results reveal that S1-S(stem of Teucrium chamaedrys L. subsp. sinuatum) has the highest values of l/q and Zeff.
文摘We have proposed a pocket formula for mass attenuation coefficient(μ/ρ), mass energy absorption coefficient(μ_(en)/ρ), and effective atomic number(Z_(eff)) in different tissues of human organs. We have also assigned a new chemical formula for all studied tissues based on their composition. We have introduced a new parameter called effective composition index(C_(eff)). Based on this, we have introduced a new method to compute the effective atomic number. The evaluated photon interaction parameters are graphically represented. The evaluated average, maximum,minimum, and standard deviations of effective atomic number are tabulated. The proposed formula produces a mass attenuation coefficient, mass energy absorption coefficient, and effective atomic number from their
基金supported by Scientific Research 277 Project of Ege University under Project No.2014 FEN 026278 Uludag University under Project No.OUAP(F)-2012/26
文摘The gamma-ray mass attenuation coefficients of blood,bone,lung,eye lens,adipose,tissue,muscle,brain and skin were calculated at different energies(60,80,150,400,500,600,1000,1250,1500,and 2000 keV) by various theoretical methods such as FLUKA,GEANT4 Monte Carlo(MC) methods and XCOM program in this work.Calculated coefficients were also compared with the National Institute of Standards and Technology(NIST) values.Obtained results were highly in accordance with each other and NIST values.Our results showed that FLUKA was quite convenient in comparison to GEANT4 in the calculation of the mass attenuation coefficients of the used human body samples for low-energy photons(60,80,and 150 keV) when compared with the NIST values.
文摘The mass attenuation coefficients of the breasts,lungs,kidneys,pancreas,liver,eye lenses,thyroid,brain,ovary,heart,large intestines,blood,skin,spleen,muscle,and cortical bone were measured at different sources(i.e.,0.021,0.029,0.03,0.14,0.218,0.38,0.412,0.663,0.83,and 1.25 MeV)using various methods including the Monte Carlo N-particle transport code(MCNP),the geometry and tracking code(GEANT4),and theoretical approach described in this study.Mass attenuation coefficients were also compared with the values from the national institute of standards and technology(NIST-XCOM).The values obtained were similar to those obtained using NISTXCOM.Our results show that the theoretical method is quite convenient in comparison with GEANT4 and MCNP in the calculation of the mass attenuation coefficients of the human body samples applied when compared with the NIST values and demonstrated an acceptable difference.
文摘The present work investigates the linear and mass attenuation coefficients for gamma rays practically and theoretically by using spectroscopy gamma ray (UCS-20) and program (XCOM)) for various types of common use granite, and compares them with the lead because of its high blocking ability for this type of radiation. This paper concluded through linear and mass attenuation coefficients measurements that these coefficients decrease with increasing incident photons energy. Measurements also showed that the linear attenuation coefficients appropriate linearly with density while mass attenuation coefficients do not get affected.
文摘Amino acids are the building blocks of proteins,which are the most abundant macromolecules in living cells.From the standpoint of the photon interaction cross sections of amino acids,the mass attenuation coefficients,half and tenth value layers,mean free path,effective atomic and electronic cross sections,effective atomic number,and effective electron density of fifteen essential amino acids have been determined for 133Ba,137Cs,and 60Co gamma-ray sources.The MCNP-4C code and the XCOM program have been used to calculate these parameters.The results have been compared to the available experimental and theoretical data.The theoretical results agreed with the experimental data,with RD values of ≤±7%.In the energy region of 81-1332.5 keV,it was found that the μm,σa,and revalues of the amino acids decreased as the photon energy increased,and the increasing density of amino acids had no steady effect on these quantities.Additionally,results demonstrated that the HVL,TVL,and MFP values increased with the increase in photon energy.The μm,σa,and Zeff values of aspartic acid were the highest among those of all amino acids,and they were the lowest for isoleucine.The Zeff value of each sample containing H,C,N,and O atoms was nearly constant in the studied energy region.The Neffvalues of the studied amino acids varied in the range of 3.14×10^23-3.44×10^23 electron/g.Furthermore,the Neffvalues were approximately independent of the amino acid type in this energy region.
文摘The gamma quanta attenuation studies have been carried out to determine mass attenuation coefficients of 7041, 7075 and 7095 wrought aluminum alloys. The temperature dependence of linear attenuation coefficient, density and thermal expansion of these wrought aluminum alloys in the temperature range 300 K - 850 K have been reported. The measurements were done by using a gamma ray densitometer designed and fabricated in our laboratory. The data on variation of density and linear thermal expansion with temperature have been represented by linear equations. Volume thermal expansion coefficients have been reported.
基金The State Key Program of National Natural Science Foundation of China under contract No.41941012the National Key R&D Program of China under contract No.2018YFA0605903the National Natural Science Foundation of China under contract Nos 41776192 and 41976218。
文摘The hydrographic and bio-optical properties of the Bering Sea shelf were analyzed based on in-situ measurements obtained during four cruises from 2007 to 2009.According to the temperature and salinity of the seawater,the spring water masses on the Bering Sea shelf were classified as the Alaskan Coast Water,Bering Sea Shelf Water,Anadyr Water,Spring Mixed Layer Water,Remnant Winter Water,and Winter Water,each of which had varying chlorophyll a concentrations.Among them,the highest chlorophyll a concentration occurred in the nutrient-rich Anadyr Water((7.57±6.16)mg/m^(3) in spring).The spectrum-dependent diffuse attenuation coefficient(Kd(λ))of the water column for downwelling irradiance was also calculated,exhibiting a decrease at 412-555 nm and then an increase within the range of 0.17-0.48 m-1in spring.Furthermore,a strong correlation between the chlorophyll a concentration and the attenuation coefficient was found at visible wavelengths on the Bering Sea shelf.Spatially,the chlorophyll a concentration was higher on the northern shelf((5.18±3.78)mg/m^(3))than on the southern shelf((3.64±2.51)mg/m^(3)),which was consistent with the distribution of the attenuation coefficient.Seasonally,the consumption of nutrients by blooms resulted in minimum chlorophyll a concentration((0.78±0.51)mg/m^(3))and attenuation coefficient values in summer.In terms of the vertical structure,both the attenuation coefficient and the chlorophyll a concentration tended to reach maximum values at the same depth,and the depth of the maximum values increased as the surface temperature increased in summer.Moreover,an empirical model was fitted with a power function based on the correlation between the chlorophyll a concentration and the attenuation coefficient at 412-555 nm.In addition,a spectral model was constructed according to the relationship between the attenuation coefficients at 490 nm and at other wavelengths,which provides a method for estimating the bio-optical properties of the Bering Sea shelf.
文摘介绍了3种X射线空气质量衰减系数的测量方法:移动距离法、抽真空法、EGSnrc蒙特卡罗模拟计算法。给出了抽真空法中真空管内空气质量厚度改变量的计算公式,并模拟分析了真空管Be窗对实验的影响。移动距离法与抽真空法得到的结果较接近,验证了抽真空法实验的合理性。当X射线能量为6 ke V、20 ke V时,EGSnrc蒙特卡罗模拟计算结果与NIST标准数据库数值偏差分别为0. 01%、0. 26%。