A Reflectron Time-of-Flight Mass Spectrometer with a Nano-Electrospray Ionization Source for Study of Metal Cluster Compounds
1
作者 吴小虎 谢华 +3 位作者 刘志凌 苏海峰 林水潮 唐紫超 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2016年第4期401-406,I0001,共7页
An experiment facility has been set up for the study of metal cluster compounds in our laboratory, which consists of a nano-electrospray ionization source, an ion transmission and focus system, and a reflectron time-o... An experiment facility has been set up for the study of metal cluster compounds in our laboratory, which consists of a nano-electrospray ionization source, an ion transmission and focus system, and a reflectron time-of-fight mass spectrometer. Taking advantage of the nano-electrospray ionization source, polyvalent ions are usually produced in the "ionization" process and the obtained mass resolution of the equipment is over 8000. The molecular ion peaks of metal cluster compounds [Au20(PPhpy2)10Cl2](SbF6)4, where PPhpy2=bis(2- pyridyl)phenylphosphine, and [AuaAg2(C)L6](BF4)4, where L=2-(diphenylphosphino)-5- methylpyridine, are distinguished in the respective mass spectrum, accompanied by some fragment ion peaks. In addition, the mass-to-charge ratios of the parent ions are determi- nated. Preliminary results suggest that the device is a powerful tool for the study of metal cluster compounds. It turns out that the information obtained by the instrumentation serves as an essential supplement to single crystal X-ray diffraction for structure characterization of metal cluster compounds. 展开更多
关键词 Nano-electrospray ionization source ion transmission and focus system Reflectron time-of-flight mass spectrometer Metal cluster compounds Single crystal X-ray diffraction
下载PDF
A NEW ELECTRON IMPACT STORAGE ION SOURCE 被引量:1
2
作者 徐贞林 田锡惠 《Transactions of Tianjin University》 EI CAS 1995年第2期138+133-137,共6页
A new electron impact storage ion source has been designed for time of flight mass spectrometers with a high mass resolving power and high sensitivity. Because of the storage and compressing focus of the source, the o... A new electron impact storage ion source has been designed for time of flight mass spectrometers with a high mass resolving power and high sensitivity. Because of the storage and compressing focus of the source, the overall performance of the instrument has been improved greatly with a mass resolving power up to 3 500. The conditions of the second order of the focus are given and the storage ability is proved. The competer simulations and experiment results are given, too. 展开更多
关键词 electron impact ion source time of flight mass spectrometer
下载PDF
Absolute partial and total ionization cross sections of carbon monoxide with electron collision from 350 eV to 8000 eV
3
作者 Taj Wali Khan 黄伟哲 +2 位作者 王恩亮 单旭 陈向军 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期459-464,共6页
The absolute partial and total cross sections for electron impact ionization of carbon monoxide are reported for electron energies from 350 eV to 8000 eV.The product ions(CO^(+),C^(+),O^(+),CO^(2+),C^(2+),and O^(2+))a... The absolute partial and total cross sections for electron impact ionization of carbon monoxide are reported for electron energies from 350 eV to 8000 eV.The product ions(CO^(+),C^(+),O^(+),CO^(2+),C^(2+),and O^(2+))are measured by employing an ion imaging mass spectrometer and two ion-pair dissociation channels(C^(+)+O^(+)and C^(2+)+O^(+))are identified.The absolute cross sections for producing individual ions and their total,as well as for the ion-pair dissociation channels are obtained by normalizing the data of CO^(+)to that of Ar^(+)from CO-Ar mixture target with a fixed 1:1 ratio.The overall errors are evaluated by considering various kinds of uncertainties.A comprehensive comparison is made with the available data,which shows a good agreement with each other over the energy ranges that are overlapped.This work presents new cross-section data with electron energies above 1000 eV. 展开更多
关键词 electron impact ionization cross sections carbon monoxide ion imaging mass spectrometer
下载PDF
面向MEMS质谱仪离子源的场发射针尖阵列研制及性能
4
作者 吴章旭 程玉鹏 +5 位作者 李山 朱五林 沈琛 胡郑蕊 徐椿景 陈池来 《微纳电子技术》 CAS 2024年第9期100-107,共8页
针对微电子机械系统(MEMS)质谱仪应用中对高工作气压和高电子电流的需求,同时保持MEMS技术在体积和质量上的优势,研制了一种用于MEMS质谱仪离子源的基于场发射原理的针尖阵列。通过MEMS加工技术实现了最大44个/mm^(2)的针尖密度,并在4和... 针对微电子机械系统(MEMS)质谱仪应用中对高工作气压和高电子电流的需求,同时保持MEMS技术在体积和质量上的优势,研制了一种用于MEMS质谱仪离子源的基于场发射原理的针尖阵列。通过MEMS加工技术实现了最大44个/mm^(2)的针尖密度,并在4和6英寸(1英寸=2.54 cm)的硅基晶圆上完成平行批量制造。实验结果显示,1600个针尖组成的阵列在3.4×10^(-3)Pa气压下最大发射电流达到1.28 mA,在23.71 Pa的气压下达到92.93μA,同时单片集成结构使其具备与永磁体结合的放电增强能力,磁场下针尖阵列的最大放电电流提升175.79%。初步的测试结果证实了场发射针尖阵列作为离子源在MEMS质谱仪中的应用潜力。 展开更多
关键词 质谱仪 微电子机械系统(MEMS) 针尖阵列 离子源 场发射 电子发射
下载PDF
Generation of multiple charged ions: Photoemission electron impact ionization
5
作者 王利 李海洋 +1 位作者 白吉玲 吕日昌 《Science China Chemistry》 SCIE EI CAS 1998年第5期525-534,共10页
Delayed pulsed electric field was used to investigate the generation mechanism of multiple charged ions produced in the interaction of laser, metal surface and electric field on time_of_flight mass spectrometer (TOF M... Delayed pulsed electric field was used to investigate the generation mechanism of multiple charged ions produced in the interaction of laser, metal surface and electric field on time_of_flight mass spectrometer (TOF MS). A special photoelectron generator was designed to control the energy and timing of the photoelectron beam. This modification made it possible to separate the photoionization process from photoelectron impact ionization. The experiment showed that the multiple charged ions could be produced only by the photoelectron impact, ionized step by step. A design of dual ionization configuration was presented, which could be used to study either multiphoton ionization or photoemission electron impact ionization. 展开更多
关键词 MULTIPLE CHARGED ionS PHOTOEMISSion electron electron impact ionIZATion time_of_flight mass spectrometer.
原文传递
小型高分辨电子轰击离子源反射式飞行时间质谱仪的研制 被引量:6
6
作者 何坚 黄如俊 +2 位作者 李刚 唐紫超 林水潮 《分析化学》 SCIE EI CAS CSCD 北大核心 2012年第10期1616-1621,共6页
常用的气体分析质谱仪使用四极杆质谱作为分析器,分辨率一般低于300,无法解决同质量数离子带来的干扰问题。本实验自行研制了一种小型高分辨气体分析质谱仪,它采用电子轰击离子源反射式飞行时间质量分析器。仪器腔体总长45 cm,在m/z 28... 常用的气体分析质谱仪使用四极杆质谱作为分析器,分辨率一般低于300,无法解决同质量数离子带来的干扰问题。本实验自行研制了一种小型高分辨气体分析质谱仪,它采用电子轰击离子源反射式飞行时间质量分析器。仪器腔体总长45 cm,在m/z 28的位置,质量分辨率达到3000(Full width at half maximum,FWHM),实现了CO和N2的半峰谷分离;在m/z 69的位置,仪器分辨率达到5000(FWHM)。在直接大气压进样条件下,可以检测到空气中136Xe(含量7.8μg/m3)和80Kr(含量2.8μg/m3)。使用ADC采集时,仪器的动态范围为106。该仪器将作为高端气体质谱仪,应用于过程监测在线分析、环境有机挥发物研究、热分析质谱及催化反应监测等领域。 展开更多
关键词 气体分析质谱仪 电子轰击离子源 质量分辨率 飞行时间质谱
下载PDF
宽离子能量检测范围垂直引入反射式飞行时间质谱仪的研制 被引量:5
7
作者 谭国斌 黄正旭 +1 位作者 高伟 周振 《分析化学》 SCIE EI CAS CSCD 北大核心 2013年第10期1614-1619,共6页
本实验室研制了国内首台宽离子能量检测范围飞行时间质谱仪。仪器采用紧凑式电子轰击源设计,配合离子透镜系统有效的调制离子流,飞行时间质量分析器采用了离子垂直引入式,双场加速和双场反射以及大尺寸MCP检测装置设计。仪器单离子... 本实验室研制了国内首台宽离子能量检测范围飞行时间质谱仪。仪器采用紧凑式电子轰击源设计,配合离子透镜系统有效的调制离子流,飞行时间质量分析器采用了离子垂直引入式,双场加速和双场反射以及大尺寸MCP检测装置设计。仪器单离子信号半峰宽约2ns,仪器分辨率优于1600FWHM,检测实际样品质量范围为1~127amu(仪器理论质量检测上限优于800ainu),可检测离子能量范围优于2个数量级(3~140eV)。若该TOF质量分析器与短瞬高压脉冲放电离子源耦合联用,可广泛应用于高能离子束的快速检测,如真空阴极放电对制备薄膜、离子注入材料的表征,导电材料的离子电荷态分布以及离子扩散速度的测定等。 展开更多
关键词 宽离子能量检测范围 电子轰击离子源 飞行时间质谱仪
下载PDF
基于叠型场线性离子阱的便携式质谱仪研制与应用 被引量:3
8
作者 黄泽建 江游 +2 位作者 熊行创 张小华 方向 《质谱学报》 EI CAS CSCD 2011年第2期104-107,共4页
介绍了自行研制的基于叠型场线性离子阱的便携式质谱仪结构,以及初步的应用测试。该质谱仪的质量分析器采用叠型场线性离子阱,离子源采用辉光放电电子轰击电离源和介质阻挡放电离子源。仪器重10 kg,功耗低于100 W,体积33 cm×20 cm&... 介绍了自行研制的基于叠型场线性离子阱的便携式质谱仪结构,以及初步的应用测试。该质谱仪的质量分析器采用叠型场线性离子阱,离子源采用辉光放电电子轰击电离源和介质阻挡放电离子源。仪器重10 kg,功耗低于100 W,体积33 cm×20 cm×20 cm,可以对气体、固体和液体进行检测。挥发性有机气体通过膜进样接口实现大气压直接进样,采用内置的辉光放电电子轰击电离源对其电离。介质阻挡放电离子源作为大气压离子源,通过非连续大气压接口实现质谱的大体积进样,及对枪击残留物DDU和去痛片等的快速检测。 展开更多
关键词 小型质谱仪 离子阱 辉光放电电子轰击电离 介质阻挡放电
下载PDF
高分辨率高灵敏度飞行时间质谱仪 被引量:3
9
作者 徐贞林 田锡惠 佟晖 《仪器仪表学报》 EI CAS CSCD 北大核心 1996年第5期508-512,共5页
本文讨论了提高飞行时间质谱仪的分辨率和灵敏度的基本问题,给出了仪器的结构设计。实验表明,其分辨率R>2500,灵敏度为30A/Pa。
关键词 质谱仪 飞行时间 高分辨率仪器
下载PDF
用于与全二维气相色谱联用的高通量飞行时间质谱仪的研制 被引量:6
10
作者 吴曼曼 岑延相 +2 位作者 杨丽华 乔佳 高伟 《分析化学》 SCIE EI CAS CSCD 北大核心 2016年第11期1786-1792,共7页
研制了可与全二维气相色谱联用的高通量飞行时间质谱仪,并进行了性能水平测试。设计采用新型高灵敏度电子轰击源及具有垂直引入、双推斥脉冲、二级反射式结构的飞行时间质量分析器,结合高于20 kHz的推斥频率,可获得质量范围1-1000 amu,... 研制了可与全二维气相色谱联用的高通量飞行时间质谱仪,并进行了性能水平测试。设计采用新型高灵敏度电子轰击源及具有垂直引入、双推斥脉冲、二级反射式结构的飞行时间质量分析器,结合高于20 kHz的推斥频率,可获得质量范围1-1000 amu,质量分辨〉1000(m/z 219,ADC采集卡),检出限低于1 pg,线性动态范围超过4个数量级,同时最快可达400谱/s的高采集速度,完全满足全二维气相色谱与飞行时间质谱联用的检测要求。与一款完全国产化的全二维气相色谱仪联用,实现对石油、香精、环境等多个领域复杂样品的分析,获得令人满意的检测结果,显示了此质谱仪器与全二维气相色谱联用的适用性及其在复杂样品体系全组分分析中的应用潜力。 展开更多
关键词 飞行时间质谱 高通量 电子轰击源 全二维气相色谱
下载PDF