The present study aims to establish a reproducible large animal experimental unit using a minipig model to monitor cardiac function changes.A 90-min closed-chest bal-loon occlusion of the left anterior descending bran...The present study aims to establish a reproducible large animal experimental unit using a minipig model to monitor cardiac function changes.A 90-min closed-chest bal-loon occlusion of the left anterior descending branch of the coronary artery was used to induce myocardial infarction in Pannon minipigs.To monitor the cardiac function,measurements were made by cardiac magnetic resonance imaging(cMRI),invasive pressure monitoring,and a Pulse index Continuous Cardiac Output(PiCCO)hemo-dynamic system at 0,72,and 720 h during the follow-up period.End-diastolic and end-systolic volumes(EDV,ESV),left ventricular ejection fraction(LVEF)obtained by cMRI evaluation,global ejection fraction and aortic dP/dt_(max)obtained by the invasive method,were recorded and compared.The 72-and 720-h EDV data showed a signifi-cant increase(p=0.012,<0.001)compared to baseline,and the Day 30 data showed a significant increase compared to Day 3(p=0.022).The ESV 72 h after the infarction showed a significant increase(p=0.001)compared to baseline,which did not change significantly by Day 30(p=0.781)compared to Day 3.EDV and ESV were signifi-cantly negatively correlated with aortic dp_(max),and ESV was significantly correlated with LVEF.For LVEF and dP_(max),a significant(p<0.001 and p=0.002)worsening was demonstrated at Day 3 compared to baseline,which was no longer statistically de-tectable for LVEF at Day 30(p=0.141),while the difference for dP_(max)was maintained(p=0.002).The complementary use of PiCCO hemodynamic measurements in large animal models makes the previously used methodologies more robust and reliable.展开更多
目的为评价CEREC椅旁CAD/CAM系统制作的IPS e.max CAD玻璃陶瓷高嵌体应用于根管治疗后牙缺损病例的临床效果。方法选择42例根管治疗后牙,应用高嵌体的牙体预备方式,采用CEREC椅旁CAD/CAM修复系统和IPS e.max CAD玻璃陶瓷,即刻完成修复...目的为评价CEREC椅旁CAD/CAM系统制作的IPS e.max CAD玻璃陶瓷高嵌体应用于根管治疗后牙缺损病例的临床效果。方法选择42例根管治疗后牙,应用高嵌体的牙体预备方式,采用CEREC椅旁CAD/CAM修复系统和IPS e.max CAD玻璃陶瓷,即刻完成修复体并粘接;修复1年后复查,参照改良修正后的美国公众健康服务标准(US Public Health Service Criteria,USPHS),在修复体边缘染色、边缘继发龋、修复体边缘适合性、修复体崩瓷折裂或脱落、修复体颜色、牙龈健康状况、修复体邻接关系、患者满意度8个方面进行评价。结果修复体边缘染色C级病例1例,成功率97.6%;边缘继发龋C级病例1例,成功率97.6%;修复体邻接关系欠佳C级病例1例,成功率97.6%;在边缘适合性、修复体崩瓷折裂或脱落、修复体颜色、牙龈健康状况、患者满意方面表现优秀,成功率均为100%。结论椅旁CAD/CAM系统制作的IPS e.maxCAD高嵌体修复体在短期内可取得良好的修复效果。展开更多
基金This research did not receive any specific grant from funding agen-cies in the public,commercial,or not-for-profit sectors.
文摘The present study aims to establish a reproducible large animal experimental unit using a minipig model to monitor cardiac function changes.A 90-min closed-chest bal-loon occlusion of the left anterior descending branch of the coronary artery was used to induce myocardial infarction in Pannon minipigs.To monitor the cardiac function,measurements were made by cardiac magnetic resonance imaging(cMRI),invasive pressure monitoring,and a Pulse index Continuous Cardiac Output(PiCCO)hemo-dynamic system at 0,72,and 720 h during the follow-up period.End-diastolic and end-systolic volumes(EDV,ESV),left ventricular ejection fraction(LVEF)obtained by cMRI evaluation,global ejection fraction and aortic dP/dt_(max)obtained by the invasive method,were recorded and compared.The 72-and 720-h EDV data showed a signifi-cant increase(p=0.012,<0.001)compared to baseline,and the Day 30 data showed a significant increase compared to Day 3(p=0.022).The ESV 72 h after the infarction showed a significant increase(p=0.001)compared to baseline,which did not change significantly by Day 30(p=0.781)compared to Day 3.EDV and ESV were signifi-cantly negatively correlated with aortic dp_(max),and ESV was significantly correlated with LVEF.For LVEF and dP_(max),a significant(p<0.001 and p=0.002)worsening was demonstrated at Day 3 compared to baseline,which was no longer statistically de-tectable for LVEF at Day 30(p=0.141),while the difference for dP_(max)was maintained(p=0.002).The complementary use of PiCCO hemodynamic measurements in large animal models makes the previously used methodologies more robust and reliable.
文摘目的为评价CEREC椅旁CAD/CAM系统制作的IPS e.max CAD玻璃陶瓷高嵌体应用于根管治疗后牙缺损病例的临床效果。方法选择42例根管治疗后牙,应用高嵌体的牙体预备方式,采用CEREC椅旁CAD/CAM修复系统和IPS e.max CAD玻璃陶瓷,即刻完成修复体并粘接;修复1年后复查,参照改良修正后的美国公众健康服务标准(US Public Health Service Criteria,USPHS),在修复体边缘染色、边缘继发龋、修复体边缘适合性、修复体崩瓷折裂或脱落、修复体颜色、牙龈健康状况、修复体邻接关系、患者满意度8个方面进行评价。结果修复体边缘染色C级病例1例,成功率97.6%;边缘继发龋C级病例1例,成功率97.6%;修复体邻接关系欠佳C级病例1例,成功率97.6%;在边缘适合性、修复体崩瓷折裂或脱落、修复体颜色、牙龈健康状况、患者满意方面表现优秀,成功率均为100%。结论椅旁CAD/CAM系统制作的IPS e.maxCAD高嵌体修复体在短期内可取得良好的修复效果。
文摘将α-Fe_(2)O_(3)@C与钛粉和铝粉一同进行高温煅烧,制备了Fe O@C/MAX(FCM)复合材料。通过XRD、SEM、TEM表征了FCM复合材料在不同Ti/C与Al/C物质的量比下的结构、组成及形貌变化,采用电化学动力学分析方法定量计算了FCM复合材料的赝电容占比,推测可能的电荷储存机理。结果表明,随着Ti/C与Al/C物质的量比的增大,FCM复合材料中MAX相(Ti_(2)Al C和Ti_(3)Al C_(2))的含量随之变化,而α-Fe_(2)O_(3)转变为不稳定的Fe O。当n(Ti)∶n(Al)∶n(C)=3∶1∶2时,制得的FCM-312样品在1 m V/s扫描速率下的比电容最大,为125.09 F/g,约为α-Fe_(2)O_(3)@C的4.76倍。FCM复合材料中部分MAX相在电化学过程中发生氧化还原反应,为离子间电子快速输运提供了条件,增加了FCM复合材料的赝电容占比。其中,FCM-312样品在10 m V/s扫描速率下的赝电容占比为22.12%。