Measuring multi-directional waves with the wave gauge array is one of the fundamental and easily realised methods. In this paper, the wave gauge array is described and the effects of the gauge spacing, the array orien...Measuring multi-directional waves with the wave gauge array is one of the fundamental and easily realised methods. In this paper, the wave gauge array is described and the effects of the gauge spacing, the array orientations, etc. of the three array arrangements, i. e., linear array, T-type array and pentagon array, on the resolution of the directional spreading of waves, are investigated experimentally. This study can be used as a reference in the experimental study and the field measurement of directional waves.展开更多
Rail irregularities, in particular for urban rail- way infrastructures, are one of the main causes for the generation of noise and vibrations. In addition, repetitive loading may also lead to decay of the structural e...Rail irregularities, in particular for urban rail- way infrastructures, are one of the main causes for the generation of noise and vibrations. In addition, repetitive loading may also lead to decay of the structural elements of the rolling stock. This further causes an increase in main- tenance costs and reduction of service life. Monitoring these defects on a periodic basis enables the network rail managers to apply proactive measures to limit further damage. This paper discusses the measurement methods for rail corrugation with particular regard to the analysis tools for evaluating the thresholds of acceptability in re- lation to the tramway Italian transport system. Further- more, a method of analysis has been proposed: an application of the methodology used for treating road profiles has been also utilized for the data processing of rail profilometric data.展开更多
Several methods for investigating the thickness uniformity of polymer thin films are presented as well as their measurement principles. A comparison of these experimental methods is given.The cylindrical lightwave ref...Several methods for investigating the thickness uniformity of polymer thin films are presented as well as their measurement principles. A comparison of these experimental methods is given.The cylindrical lightwave reflection method is found to can obtain the thickness distribution along a certain direction.It is a simple and suitable method to evaluate the film thickness uniformity.展开更多
In the terahertz band,the dispersive characteristic of dielectric material is one of the major problems in the scaled radar cross section(RCS)measurement,which is inconsistent with the electrodynamics similitude deduc...In the terahertz band,the dispersive characteristic of dielectric material is one of the major problems in the scaled radar cross section(RCS)measurement,which is inconsistent with the electrodynamics similitude deducted according to the Maxwell’s equations.Based on the high-frequency estimation method of physical optics(PO),a scaled RCS measurement method for lossy objects is proposed through dynamically matching the reflection coefficients according to the distribution of the object facets.Simulations of the model of SLICY are conducted,and the inversed RCS of the lossy prototype is obtained using the proposed method.Comparing the inversed RCS with the calculated results,the validity of the proposed method is demonstrated.The proposed method provides an effective solution to the scaled RCS measurement for lossy objects in the THz band.展开更多
Method of VSC (Voltage Shorted Compaction)can be used to determine the intrinsic temperature dependence ofconductivity ofpolycrystalline compaction. The experimental conditions and technical key for preparation of VSC...Method of VSC (Voltage Shorted Compaction)can be used to determine the intrinsic temperature dependence ofconductivity ofpolycrystalline compaction. The experimental conditions and technical key for preparation of VSC device and its physical model as well as its applications in conducting polymers are discussed in detail.展开更多
Through the experimental design and theoretical analysis, three technologies used for characterizing the two-photon absorption(TPA) properties, such as nonlinear transmission experiment and theory, Z-scan technology a...Through the experimental design and theoretical analysis, three technologies used for characterizing the two-photon absorption(TPA) properties, such as nonlinear transmission experiment and theory, Z-scan technology and two-photon induced fluorescence method, are introduced. The properties of the three experiments to be utilizable and realizable under desirable limitation are simply analyzed. The advantages of the measurements for TPA characterization are also analyzed.展开更多
The Quality factor is the parameter that can be used to describe the energy attenuation on seismic wave. In theory, we can obtain the relationship between the change of the coda wave quality factor with time and the s...The Quality factor is the parameter that can be used to describe the energy attenuation on seismic wave. In theory, we can obtain the relationship between the change of the coda wave quality factor with time and the strong earthquake preparation process on the basis of the quality factor of a coda wave in a same ray path. However, in reality the coda wave quality factor measured by different seismic coda waves corresponds to different seismic wave ray paths. The change of the quality factor with time is related to non-elastic characteristics of the medium and the volume of scattering ellipsoid constrained by scattered wave phase fronts, besides the change of regional stress field. This paper discusses the relationship between quality factor, epicenter distance and different lapse time, and then discusses the relationship between quality factor and frequency. Furthermore the determination method of the coda wave quality factor is put forward. The improved determination method of the quality factor, which removes the influence of different earthquakes or propagation depth of scattered waves, may increase measurement precision, thus information pertaining to abnormal changes in quality factor and the relationship between the quality factor and earthquake preparation process can be acquired.展开更多
Objective to study an in vitro accurate measurement method for the placement depth of PICC. Methods 270 patients undergoing PICC catheterization under ultrasound guidance in outpatient PICC catheterization from March ...Objective to study an in vitro accurate measurement method for the placement depth of PICC. Methods 270 patients undergoing PICC catheterization under ultrasound guidance in outpatient PICC catheterization from March to September 2019 were selected by convenient sampling. By using the random number table method, the subjects were divided into group A (horizontal L-type measurement method) and Group B (characteristic index measurement calculation) by 1:1, with 135 cases in each group. X-ray chest radiograph was taken after catheterization in both groups, and the indwelling position of the catheter was adjusted according to the X-ray chest radiograph. The correlation between PICC predicted length and ideal depth and patient satisfaction were compared between the two groups. Results The success rate of PICC catheter tip insertion in group B was 97.78%, while that in control group A was 82.22%, the difference was statistically significant (P < 0.05). The satisfaction degree of patients in group B was significantly higher than that in group A. The differences were statistically significant (P < 0.05). Conclusion Improving the success rate of the precise depth of PICC catheter placement can significantly reduce the incidence of complications, waste of human and material resources caused by adjusting the catheter position, and significantly improve patient satisfaction.展开更多
Laser display technology is the most promising display technology in the market and is widely used in many fields. However, laser speckle has been troubling the application and expansion of this technology in some fie...Laser display technology is the most promising display technology in the market and is widely used in many fields. However, laser speckle has been troubling the application and expansion of this technology in some fields. In order to better evaluate the speckle, speckle measurement methods must be studied. In this study, a dynamic measurement method for laser speckles is proposed according to the optical superposition characteristics of speckle, which can reduce the influence of non-coherent factors on the speckle measurement results. The feasibility of the dynamic speckle measurement method is verified by designing an experimental scheme.展开更多
The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(R...The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(RCZ) is built. The formula for an ultimate cutting force is established based on the limit equilibrium principle. The relationship between digital drilling parameters(DDP) and the c-φ parameter(DDP-cφ formula, where c refers to the cohesion and φ refers to the internal friction angle) is derived, and the response of drilling parameters and cutting ratio to the strength parameters is analyzed. The drillingbased measuring method for the c-φ parameter of rock is constructed. The laboratory verification test is then completed, and the difference in results between the drilling test and the compression test is less than 6%. On this basis, in-situ rock drilling tests in a traffic tunnel and a coal mine roadway are carried out, and the strength parameters of the surrounding rock are effectively tested. The average difference ratio of the results is less than 11%, which verifies the effectiveness of the proposed method for obtaining the strength parameters based on digital drilling. This study provides methodological support for field testing of rock strength parameters.展开更多
Aiming at the approximate measurement of magnetic rotation angle in optical current sensor based on light intensity detection mode,this paper proposes a current measurement method based on triangular constant transfor...Aiming at the approximate measurement of magnetic rotation angle in optical current sensor based on light intensity detection mode,this paper proposes a current measurement method based on triangular constant transformation to reconstruct magnetic rotation angle,so as to avoid the large current measurement error caused by the approximate measurement of the magnetic rotation angle.By extracting the direct current(DC)component and the alternating current(AC)component of the light intensity signal detected by the photoelectric detector(PD),the sine signal containing the magnetic rotation angle is directly obtained by dividing the two components,and then the triangular identity transformation method is used to linearly demodulate the magnetic rotation angle and reconstruct the current waveform.The experimental results show that the relative error of current measurement does not exceed 1.40%in the current range of 0.05—0.50 A,which is less than the approximate linear measurement(ALM)method,and the magnetic rotation angle and the current have a good linear relationship.展开更多
Peroxyacetic acid has been widely used in food,medical,and synthetic chemical fields for the past several decades.Recently,peroxyacetic acid has gradually become an effective alternative disinfectant in wastewater dis...Peroxyacetic acid has been widely used in food,medical,and synthetic chemical fields for the past several decades.Recently,peroxyacetic acid has gradually become an effective alternative disinfectant in wastewater disinfection and has strong redox capacity for removing micro-pollutants from drinking water.However,commercial peroxyacetic acid solutions are primarily multi-component mixtures of peroxyacetic acid,acetic acid,hydrogen peroxide,and water.During the process of water treatment,peroxyacetic acid and hydrogen peroxide(H2O2)often coexist,which limits further investigation on the properties ofperoxyacetic acid.Therefore,analytical methods need to achieve a certain level of selectivity,particularly when peroxyacetic acid and hydrogen peroxide coexist.This review summarizes the measurement and detection methods of peroxyacetic acid,comparing the principle,adaptability,and relative merits of these methods.展开更多
A novel measurement method of temperature model for bioreactor has been proposed.Temperature is the key parameter in monitoring the bioreactor operation.However,the system input signal of bioreactor is delayed,and mod...A novel measurement method of temperature model for bioreactor has been proposed.Temperature is the key parameter in monitoring the bioreactor operation.However,the system input signal of bioreactor is delayed,and model parameters are uncertain,so the output of temperature is non-steady-state.Many dynamic measurements are not steady so that it cannot be described by variables constant in time.In this paper,we adopt the monopulse signal as input so that the output of the bioreactor system is steady.This method has a powerful ability to steady the output of the bioreactor.In view of the measurement results,it can be seen that the model dynamic measurement approaches the real process.The analytical expression of the monopulse response for the temperature model of the bioreactor is obtained.The novel measurement approach is simple and can be easily adopted by industry.展开更多
Rail transit plays a key role in mitigating transportation system carbon emissions.Accurate measurement of urban rail transit carbon emission can help quantify the contribution of urban rail transit towards urban tran...Rail transit plays a key role in mitigating transportation system carbon emissions.Accurate measurement of urban rail transit carbon emission can help quantify the contribution of urban rail transit towards urban transportation carbon emission reduction.Since the whole life cycle of urban rail transit carbon emission measurement involves a wide range of aspects,a systematic framework model is required for analysis.This research reviews the existing studies on carbon emission of urban rail transit.First,the characteristics of urban rail transit carbon emission were determined and the complexity of carbon emission measurement was analyzed.Then,the urban rail transit carbon emission measurement models were compared and analyzed in terms of the selection of research boundaries,the types of greenhouse gas(GHG)emissions calculation,and the accuracy of the measurement.Following that,an intelligent station was introduced to analyze the practical application of digital collaboration technology and energy-saving and carbon-reducing system platforms for rail transit.Finally,the urgent problems and future research directions at this stage were discussed.This research presents the necessity of establishing a dynamic carbon emission factor library and the important development trend of system integration of carbon emission measurement and digital system technology.展开更多
Prom investigation of the advantages and disadvantages of conventional tri-voltage method,a method for the measurement of the transmitting transducer's impedance was presented to solve the difficult problem of examin...Prom investigation of the advantages and disadvantages of conventional tri-voltage method,a method for the measurement of the transmitting transducer's impedance was presented to solve the difficult problem of examining the consistency of the transmitting phased array on the single-mode excitation sea spot.In the method based on the system function, the circuit structure of tri-voltage method was used but new parameters were measured.The principle of the method was given first.Then when resistors with different nominal values were used in the circuit,the measured results for the impedance of transducers were reported.The results were compared with the higher precision impedance analyzer.Finally,the error analysis was performed according to the impedance formula and the equivalent circuit parameters were fitted.Under the condition of guaranteeing the sampling precision,by performance analyzing, the resistor value in series was chosen relatively smaller than the impedance of transducer,the measurement of impedance could achieve the same precision as the higher precision impedance analyzer.Finally,the least squares curve-fitting of measured curves indicated that the transducer equivalent electrical parameters could be extracted accurately and used to design the matching network.展开更多
Previous works have shown that the suction probe cannot be used to accurately measure the upward and downward particle fluxes independently. A new method using a single optical probe to measure the local solid flux is...Previous works have shown that the suction probe cannot be used to accurately measure the upward and downward particle fluxes independently. A new method using a single optical probe to measure the local solid flux is presented. The measurement of upward, downward and net solid fluxes was carried out in a cold model circulating fluidized bed (CFB) unit. The result shows that the profile of the net solid flux is in good agreement with the previous experimental data measured with a suction probe. The comparison between the average solid flux determined with the optical measuring system and the external solid flux was made, and the maximum deviationturned out to be 22%, with the average error being about 6.9%. These confirm that the optical fiber system can be successfully used to measure the upward, downward and net solid fluxes simultaneously by correctly processing the sampling signals obtained from the optical measuring system.展开更多
Gas holdup is one of the key parameters in flotation process. Gas holdup as measured by a differential pressure method was investigated and the relative errors compared to the average gas holdup from the volume expans...Gas holdup is one of the key parameters in flotation process. Gas holdup as measured by a differential pressure method was investigated and the relative errors compared to the average gas holdup from the volume expansion method. The errors were used to establish optimum measurement positions. The results show that the measurement position should be in the middle of the column and in the region half way from the center to the wall (the half-radius). The gas holdup along the axial direction is lower at the bottom and higher at the top of the floatation column. The gas holdup along the radial direction is lower near the wall and higher near the center of the flotation column. The average gas holdup measure- ment can be replaced by regional gas holdup values.展开更多
Pavement horizontal curve is designed to serve as a transition between straight segments, and its presence may cause a series of driving-related safety issues to motorists and drivers. As is recognized that traditiona...Pavement horizontal curve is designed to serve as a transition between straight segments, and its presence may cause a series of driving-related safety issues to motorists and drivers. As is recognized that traditional methods for curve geometry investigation are time consuming, labor intensive, and inaccurate, this study attempts to develop a method that can automatically conduct horizontal curve identification and measurement at network level. The digital highway data vehicle (DHDV) was utilized for data collection, in which three Euler angles, driving speed, and acceleration of survey vehicle were measured with an inertial measurement unit (IMU). The 3D profiling data used for cross slope calibration was obtained with PaveVision3D Ultra technology at 1 mm resolution. In this study, the curve identification was based on the variation of heading angle, and the curve radius was calculated with ki- nematic method, geometry method, and lateral acceleration method. In order to verify the accuracy of the three methods, the analysis of variance (ANOVA) test was applied by using the control variable of curve radius measured by field test. Based on the measured curve radius, a curve safety analysis model was used to predict the crash rates and safe driving speeds at horizontal curves. Finally, a case study on 4.35 km road segment demonstrated that the proposed method could efficiently conduct network level analysis.展开更多
Surface potential decay of polymers for electrical insulation can help to determine the dark conductivity for spacecraft charging analysis. Due to the existence of radiation-induced conductivity, it decays fast in the...Surface potential decay of polymers for electrical insulation can help to determine the dark conductivity for spacecraft charging analysis. Due to the existence of radiation-induced conductivity, it decays fast in the first few hours after irradiation and exponentially slowly for the remaining time. The measurement of dark conductivity with this method usually takes the slow part and needs a couple of days. Integrating the Fowler formula into the deep dielectric charging equations, we obtain a new expression for the fast decay part. The experimental data of different materials, dose rates and temperatures are fitted by the new expression. Both the dark conductivity and the radiation-induced conductivity are derived and compared with other methods. The result shows a good estimation of dark conductivity and radiation-induced conductivity in high-resistivity polymers, which enables a fast measurement of dielectric conductivity within about 600 rain after irradiation.展开更多
A new dye-staining method for protein assay is described.The reaction between TPPS_4 and protein molecule causes a shift in the absorption of TPPS_4 from 435 nm to 488nm.The absorbance at 488 nm is proportional to the...A new dye-staining method for protein assay is described.The reaction between TPPS_4 and protein molecule causes a shift in the absorption of TPPS_4 from 435 nm to 488nm.The absorbance at 488 nm is proportional to the concentration of protein.The range of Beer's law was 1-5 ug/ml and the Sandell's sensitivity was 0.0087 ug/cm^2.展开更多
文摘Measuring multi-directional waves with the wave gauge array is one of the fundamental and easily realised methods. In this paper, the wave gauge array is described and the effects of the gauge spacing, the array orientations, etc. of the three array arrangements, i. e., linear array, T-type array and pentagon array, on the resolution of the directional spreading of waves, are investigated experimentally. This study can be used as a reference in the experimental study and the field measurement of directional waves.
文摘Rail irregularities, in particular for urban rail- way infrastructures, are one of the main causes for the generation of noise and vibrations. In addition, repetitive loading may also lead to decay of the structural elements of the rolling stock. This further causes an increase in main- tenance costs and reduction of service life. Monitoring these defects on a periodic basis enables the network rail managers to apply proactive measures to limit further damage. This paper discusses the measurement methods for rail corrugation with particular regard to the analysis tools for evaluating the thresholds of acceptability in re- lation to the tramway Italian transport system. Further- more, a method of analysis has been proposed: an application of the methodology used for treating road profiles has been also utilized for the data processing of rail profilometric data.
文摘Several methods for investigating the thickness uniformity of polymer thin films are presented as well as their measurement principles. A comparison of these experimental methods is given.The cylindrical lightwave reflection method is found to can obtain the thickness distribution along a certain direction.It is a simple and suitable method to evaluate the film thickness uniformity.
基金supported by the National Natural Science Foundation of China(Grant Nos.61871386,61971427,62035014,and 61921001)the Natural Science Fund for Distinguished Young Scholars of Hunan Province,China(Grant No.2019JJ20022)。
文摘In the terahertz band,the dispersive characteristic of dielectric material is one of the major problems in the scaled radar cross section(RCS)measurement,which is inconsistent with the electrodynamics similitude deducted according to the Maxwell’s equations.Based on the high-frequency estimation method of physical optics(PO),a scaled RCS measurement method for lossy objects is proposed through dynamically matching the reflection coefficients according to the distribution of the object facets.Simulations of the model of SLICY are conducted,and the inversed RCS of the lossy prototype is obtained using the proposed method.Comparing the inversed RCS with the calculated results,the validity of the proposed method is demonstrated.The proposed method provides an effective solution to the scaled RCS measurement for lossy objects in the THz band.
文摘Method of VSC (Voltage Shorted Compaction)can be used to determine the intrinsic temperature dependence ofconductivity ofpolycrystalline compaction. The experimental conditions and technical key for preparation of VSC device and its physical model as well as its applications in conducting polymers are discussed in detail.
基金Key Laboratory for Supramolecular Structure and Materials of Ministry of Education, Jilin University(KLSSM-200607)
文摘Through the experimental design and theoretical analysis, three technologies used for characterizing the two-photon absorption(TPA) properties, such as nonlinear transmission experiment and theory, Z-scan technology and two-photon induced fluorescence method, are introduced. The properties of the three experiments to be utilizable and realizable under desirable limitation are simply analyzed. The advantages of the measurements for TPA characterization are also analyzed.
基金sponsored by the Natural Science Foundation of Shandong Province (Y2007E09)Joint Earthquake Science Foundation (C08028)Special Application Research of Digital Seismic Wave Data ,Shangdong,China
文摘The Quality factor is the parameter that can be used to describe the energy attenuation on seismic wave. In theory, we can obtain the relationship between the change of the coda wave quality factor with time and the strong earthquake preparation process on the basis of the quality factor of a coda wave in a same ray path. However, in reality the coda wave quality factor measured by different seismic coda waves corresponds to different seismic wave ray paths. The change of the quality factor with time is related to non-elastic characteristics of the medium and the volume of scattering ellipsoid constrained by scattered wave phase fronts, besides the change of regional stress field. This paper discusses the relationship between quality factor, epicenter distance and different lapse time, and then discusses the relationship between quality factor and frequency. Furthermore the determination method of the coda wave quality factor is put forward. The improved determination method of the quality factor, which removes the influence of different earthquakes or propagation depth of scattered waves, may increase measurement precision, thus information pertaining to abnormal changes in quality factor and the relationship between the quality factor and earthquake preparation process can be acquired.
文摘Objective to study an in vitro accurate measurement method for the placement depth of PICC. Methods 270 patients undergoing PICC catheterization under ultrasound guidance in outpatient PICC catheterization from March to September 2019 were selected by convenient sampling. By using the random number table method, the subjects were divided into group A (horizontal L-type measurement method) and Group B (characteristic index measurement calculation) by 1:1, with 135 cases in each group. X-ray chest radiograph was taken after catheterization in both groups, and the indwelling position of the catheter was adjusted according to the X-ray chest radiograph. The correlation between PICC predicted length and ideal depth and patient satisfaction were compared between the two groups. Results The success rate of PICC catheter tip insertion in group B was 97.78%, while that in control group A was 82.22%, the difference was statistically significant (P < 0.05). The satisfaction degree of patients in group B was significantly higher than that in group A. The differences were statistically significant (P < 0.05). Conclusion Improving the success rate of the precise depth of PICC catheter placement can significantly reduce the incidence of complications, waste of human and material resources caused by adjusting the catheter position, and significantly improve patient satisfaction.
基金supported by the National Natural Science Foundation of China (No.62076160)the Natural Science Foundation of Shanghai (No.21ZR1424700)。
文摘Laser display technology is the most promising display technology in the market and is widely used in many fields. However, laser speckle has been troubling the application and expansion of this technology in some fields. In order to better evaluate the speckle, speckle measurement methods must be studied. In this study, a dynamic measurement method for laser speckles is proposed according to the optical superposition characteristics of speckle, which can reduce the influence of non-coherent factors on the speckle measurement results. The feasibility of the dynamic speckle measurement method is verified by designing an experimental scheme.
基金supported by the National Key Research and Development Program of China(No.2023YFC2907600)the National Natural Science Foundation of China(Nos.42077267,42277174 and 52074164)+2 种基金the Natural Science Foundation of Shandong Province,China(No.ZR2020JQ23)the Opening Project of State Key Laboratory of Explosion Science and Technology,Beijing Institute of Technology(No.KFJJ21-02Z)the Fundamental Research Funds for the Central Universities,China(No.2022JCCXSB03).
文摘The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(RCZ) is built. The formula for an ultimate cutting force is established based on the limit equilibrium principle. The relationship between digital drilling parameters(DDP) and the c-φ parameter(DDP-cφ formula, where c refers to the cohesion and φ refers to the internal friction angle) is derived, and the response of drilling parameters and cutting ratio to the strength parameters is analyzed. The drillingbased measuring method for the c-φ parameter of rock is constructed. The laboratory verification test is then completed, and the difference in results between the drilling test and the compression test is less than 6%. On this basis, in-situ rock drilling tests in a traffic tunnel and a coal mine roadway are carried out, and the strength parameters of the surrounding rock are effectively tested. The average difference ratio of the results is less than 11%, which verifies the effectiveness of the proposed method for obtaining the strength parameters based on digital drilling. This study provides methodological support for field testing of rock strength parameters.
基金the Joint Guidance Project of Natural Science Foundation of Heilongjiang Province(No.LH2021F008)。
文摘Aiming at the approximate measurement of magnetic rotation angle in optical current sensor based on light intensity detection mode,this paper proposes a current measurement method based on triangular constant transformation to reconstruct magnetic rotation angle,so as to avoid the large current measurement error caused by the approximate measurement of the magnetic rotation angle.By extracting the direct current(DC)component and the alternating current(AC)component of the light intensity signal detected by the photoelectric detector(PD),the sine signal containing the magnetic rotation angle is directly obtained by dividing the two components,and then the triangular identity transformation method is used to linearly demodulate the magnetic rotation angle and reconstruct the current waveform.The experimental results show that the relative error of current measurement does not exceed 1.40%in the current range of 0.05—0.50 A,which is less than the approximate linear measurement(ALM)method,and the magnetic rotation angle and the current have a good linear relationship.
基金We acknowledge supports from National Key Basic Research Program of China(Grant No.2019YFA0705800)National Natural Science Foundation of China(Nos.21876049 and 91834301).The authors show deep gratitude to Mr.Casey Finnerty from UC Berkeley on polishing the manuscript.
文摘Peroxyacetic acid has been widely used in food,medical,and synthetic chemical fields for the past several decades.Recently,peroxyacetic acid has gradually become an effective alternative disinfectant in wastewater disinfection and has strong redox capacity for removing micro-pollutants from drinking water.However,commercial peroxyacetic acid solutions are primarily multi-component mixtures of peroxyacetic acid,acetic acid,hydrogen peroxide,and water.During the process of water treatment,peroxyacetic acid and hydrogen peroxide(H2O2)often coexist,which limits further investigation on the properties ofperoxyacetic acid.Therefore,analytical methods need to achieve a certain level of selectivity,particularly when peroxyacetic acid and hydrogen peroxide coexist.This review summarizes the measurement and detection methods of peroxyacetic acid,comparing the principle,adaptability,and relative merits of these methods.
基金This work was supported by the National High Technology Research and Development Program of China(No.2004AA412050).
文摘A novel measurement method of temperature model for bioreactor has been proposed.Temperature is the key parameter in monitoring the bioreactor operation.However,the system input signal of bioreactor is delayed,and model parameters are uncertain,so the output of temperature is non-steady-state.Many dynamic measurements are not steady so that it cannot be described by variables constant in time.In this paper,we adopt the monopulse signal as input so that the output of the bioreactor system is steady.This method has a powerful ability to steady the output of the bioreactor.In view of the measurement results,it can be seen that the model dynamic measurement approaches the real process.The analytical expression of the monopulse response for the temperature model of the bioreactor is obtained.The novel measurement approach is simple and can be easily adopted by industry.
基金supported by Beijing Natural Science Foundation(J210001)Natural Science Foundation of Hebei Province(E2021210142)Tianjin Natural Science Foundation(21JCZXJC00160).
文摘Rail transit plays a key role in mitigating transportation system carbon emissions.Accurate measurement of urban rail transit carbon emission can help quantify the contribution of urban rail transit towards urban transportation carbon emission reduction.Since the whole life cycle of urban rail transit carbon emission measurement involves a wide range of aspects,a systematic framework model is required for analysis.This research reviews the existing studies on carbon emission of urban rail transit.First,the characteristics of urban rail transit carbon emission were determined and the complexity of carbon emission measurement was analyzed.Then,the urban rail transit carbon emission measurement models were compared and analyzed in terms of the selection of research boundaries,the types of greenhouse gas(GHG)emissions calculation,and the accuracy of the measurement.Following that,an intelligent station was introduced to analyze the practical application of digital collaboration technology and energy-saving and carbon-reducing system platforms for rail transit.Finally,the urgent problems and future research directions at this stage were discussed.This research presents the necessity of establishing a dynamic carbon emission factor library and the important development trend of system integration of carbon emission measurement and digital system technology.
基金supported by the National Natural Science Foundation of China(11004214,10574137)
文摘Prom investigation of the advantages and disadvantages of conventional tri-voltage method,a method for the measurement of the transmitting transducer's impedance was presented to solve the difficult problem of examining the consistency of the transmitting phased array on the single-mode excitation sea spot.In the method based on the system function, the circuit structure of tri-voltage method was used but new parameters were measured.The principle of the method was given first.Then when resistors with different nominal values were used in the circuit,the measured results for the impedance of transducers were reported.The results were compared with the higher precision impedance analyzer.Finally,the error analysis was performed according to the impedance formula and the equivalent circuit parameters were fitted.Under the condition of guaranteeing the sampling precision,by performance analyzing, the resistor value in series was chosen relatively smaller than the impedance of transducer,the measurement of impedance could achieve the same precision as the higher precision impedance analyzer.Finally,the least squares curve-fitting of measured curves indicated that the transducer equivalent electrical parameters could be extracted accurately and used to design the matching network.
文摘Previous works have shown that the suction probe cannot be used to accurately measure the upward and downward particle fluxes independently. A new method using a single optical probe to measure the local solid flux is presented. The measurement of upward, downward and net solid fluxes was carried out in a cold model circulating fluidized bed (CFB) unit. The result shows that the profile of the net solid flux is in good agreement with the previous experimental data measured with a suction probe. The comparison between the average solid flux determined with the optical measuring system and the external solid flux was made, and the maximum deviationturned out to be 22%, with the average error being about 6.9%. These confirm that the optical fiber system can be successfully used to measure the upward, downward and net solid fluxes simultaneously by correctly processing the sampling signals obtained from the optical measuring system.
基金supports for this work provided by the NationalKey Technology R&D Program in the 11th Five-Year Plan of China(No. 2008BAB31B03)
文摘Gas holdup is one of the key parameters in flotation process. Gas holdup as measured by a differential pressure method was investigated and the relative errors compared to the average gas holdup from the volume expansion method. The errors were used to establish optimum measurement positions. The results show that the measurement position should be in the middle of the column and in the region half way from the center to the wall (the half-radius). The gas holdup along the axial direction is lower at the bottom and higher at the top of the floatation column. The gas holdup along the radial direction is lower near the wall and higher near the center of the flotation column. The average gas holdup measure- ment can be replaced by regional gas holdup values.
文摘Pavement horizontal curve is designed to serve as a transition between straight segments, and its presence may cause a series of driving-related safety issues to motorists and drivers. As is recognized that traditional methods for curve geometry investigation are time consuming, labor intensive, and inaccurate, this study attempts to develop a method that can automatically conduct horizontal curve identification and measurement at network level. The digital highway data vehicle (DHDV) was utilized for data collection, in which three Euler angles, driving speed, and acceleration of survey vehicle were measured with an inertial measurement unit (IMU). The 3D profiling data used for cross slope calibration was obtained with PaveVision3D Ultra technology at 1 mm resolution. In this study, the curve identification was based on the variation of heading angle, and the curve radius was calculated with ki- nematic method, geometry method, and lateral acceleration method. In order to verify the accuracy of the three methods, the analysis of variance (ANOVA) test was applied by using the control variable of curve radius measured by field test. Based on the measured curve radius, a curve safety analysis model was used to predict the crash rates and safe driving speeds at horizontal curves. Finally, a case study on 4.35 km road segment demonstrated that the proposed method could efficiently conduct network level analysis.
基金Supported by the Fundamental Research Funds for the Central Universities in Nanjing University of Aeronautics and Astronautics under Grant No NS2014089
文摘Surface potential decay of polymers for electrical insulation can help to determine the dark conductivity for spacecraft charging analysis. Due to the existence of radiation-induced conductivity, it decays fast in the first few hours after irradiation and exponentially slowly for the remaining time. The measurement of dark conductivity with this method usually takes the slow part and needs a couple of days. Integrating the Fowler formula into the deep dielectric charging equations, we obtain a new expression for the fast decay part. The experimental data of different materials, dose rates and temperatures are fitted by the new expression. Both the dark conductivity and the radiation-induced conductivity are derived and compared with other methods. The result shows a good estimation of dark conductivity and radiation-induced conductivity in high-resistivity polymers, which enables a fast measurement of dielectric conductivity within about 600 rain after irradiation.
文摘A new dye-staining method for protein assay is described.The reaction between TPPS_4 and protein molecule causes a shift in the absorption of TPPS_4 from 435 nm to 488nm.The absorbance at 488 nm is proportional to the concentration of protein.The range of Beer's law was 1-5 ug/ml and the Sandell's sensitivity was 0.0087 ug/cm^2.