期刊文献+
共找到1,730篇文章
< 1 2 87 >
每页显示 20 50 100
Intrinsic background radiation of LaBr3(Ce)detector via coincidence measurements and simulations 被引量:11
1
作者 Hao Cheng Bao-Hua Sun +5 位作者 Li-Hua Zhu Tian-Xiao Li Guang-Shuai Li Cong-Bo Li Xiao-Guang Wu Yun Zheng 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第10期33-42,共10页
The LaBr3(Ce)detector has attracted much attention in recent years because of its superior characteristics compared with other scintillating materials in terms of resolution and efficiency.However,it has a relatively ... The LaBr3(Ce)detector has attracted much attention in recent years because of its superior characteristics compared with other scintillating materials in terms of resolution and efficiency.However,it has a relatively high intrinsic background radiation because of the naturally occurring radioisotopes in lanthanum,actinium,and their daughter nuclei.This limits its applications in low-counting rate experiments.In this study,we identified the radioactive isotopes in theφ3"x 3"Saint-Gobain B380 detector by a coincidence measurement using a Clover detector in a low-background shielding system.Moreover,we carried out a Geant4 simulation of the experimental spectra to evaluate the activities of the main internal radiation components.The total activity of the background radiation of B380 is determined to be 1.523(34)Bq/cm^3.The main sources include 138La at 1.428(34)Bq/cm^3,207Tl at 0.0135(13)Bq/cm^3,211Bi at 0.0136(15)Bq/cm^3,215Po at 0.0135(3)Bq/cm^3,219Rn at 0.0125(12)Bq/cm^3,223Fr at 0.0019(11)Bq/cm^3,223Ra at 0.0127(10)Bq/cm^3,227Th at 0.0158(22)Bq/cm^3,and 227Ac at 0.0135(13)Bq/cm^3.Of these,the activities of 207Tl,211Po,215Po,223Fr,and 227Ac are deduced for the first time from the secular equilibrium established in the decay chain of 227Ac. 展开更多
关键词 LaBr3 Coincidence measurement technique Intrinsic radiation GEANT4 simulation
下载PDF
Radiation Damage Analysis of Individual Subcells for GaInP/GaAs/Ge Solar Cells Using Photoluminescence Measurements 被引量:2
2
作者 郑勇 易天成 +2 位作者 王君玲 肖鹏飞 王荣 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第2期63-66,共4页
The radiation damage of three individual subcells for GalnP/GaAs//Ge triple-junction solar cells irradiated with electrons and protons is investigated using photoluminescence (PL) measurements. The PL spectra of eac... The radiation damage of three individual subcells for GalnP/GaAs//Ge triple-junction solar cells irradiated with electrons and protons is investigated using photoluminescence (PL) measurements. The PL spectra of each subcell are obtained using different excitation lasers. The PL intensity has a fast degradation after irradiation, and decreases as the displacement damage dose increases. Furthermore, the normalized PL intensity varying with the displacement damage dose is analyzed in detail, and then the lifetime damage coefficients of the recombination centers for GaInP top-cell, GaAs mid-cell and Ge bottom-cell of the triple-junction solar cells are determined from the PL radiative efficiency. 展开更多
关键词 radiation Damage Analysis of Individual Subcells for GaInP/GaAs/Ge Solar Cells Using Photoluminescence measurements Ge
下载PDF
Simultaneous Measurements of Rainfall Intensity, Low Energy Neutrons and Gamma Radiation in Sao Jose Dos Campos, SP, Brazil 被引量:1
3
作者 Marcelo Pego Gomes Inacio Malmonge Martin +4 位作者 Mauro Angelo Alves Bogos Nubar Sismanoglu Marco Antonio S. Ferro Marcos Pinto Flavio Antonio 《Journal of Environmental Science and Engineering(B)》 2013年第11期643-647,共5页
关键词 降雨强度 低能中子 同步测量 γ射线 SP 巴西 低能量 航空航天技术
下载PDF
Ensuring Uniformity of Measurements of Absorbed Doses of Intensive Photon and Electron Radiation in Radiation Technologies
4
作者 V. V. Generalova A. A. Gromov O. I. Kovalenko 《Journal of Applied Mathematics and Physics》 2015年第8期942-946,共5页
Ensuring reliability and traceability of the unit of absorbed dose of intense photon and electron radiation, used in radiation technologies in industry, is based on the creation of a system of sample measures and meth... Ensuring reliability and traceability of the unit of absorbed dose of intense photon and electron radiation, used in radiation technologies in industry, is based on the creation of a system of sample measures and methods of transmission with minimal loss of dimensional accuracy of the unit of absorbed dose from the sample tools to working dosimeters and is a necessary basis of yield growth, of increase of labour productivity and the introduction of innovative products. The measuring capabilities of the State primary special standard of power unit of absorbed dose of intensity photon, electron and beta radiation for radiation technologies and of the standards of the absorbed dose of photon and electron radiation, used for radiation monitoring of radiation pro- cesses. 展开更多
关键词 radiation Technology Absorbed DOSE Ensuring UNIFORMITY of measurementS Certified Reference Material
下载PDF
Environmental Radiation Measurement and Assessment of Natural Radioactivity in Soil, Water and Vegetation 被引量:1
5
作者 Nandi-Esom Chariette Ereh Meng Zhang 《Journal of Applied Mathematics and Physics》 2018年第11期2330-2337,共8页
Environmental radioactivity is produced by radioactive materials in the human environment. While some radioisotopes, such as strontium-90 (90Sr) and technetium-99 (99Tc), are only found on Earth as a result of human a... Environmental radioactivity is produced by radioactive materials in the human environment. While some radioisotopes, such as strontium-90 (90Sr) and technetium-99 (99Tc), are only found on Earth as a result of human activity, and some, like potassium-40 (40K), are only present due to natural processes, a few isotopes, e.g. tritium (3H), result from both natural processes and human activities. The concentration and location of some natural isotopes, particularly uranium-238 (238U), can be affected by human activity because of the constant exposure of Human beings to radiation caused by terrestrial, extra-terrestrial and anthropogenic radio nuclides, it is necessary to determine and estimate the activity of various radio nuclides in environmental media such as vegetation, soil, and water. In the present research, the activities of 226Ra, 232Th and 40K are measured in soil, vegetation and water samples, collected from Yangdong District, Yangxi County, and Yangjiang County of Guangdong Province, China using an HPGe based gamma spectrometry system. The measured mean activity of 226Ra, 232Th and 40K in soil samples was found to be 31.19 ± 1.2, 47.00 ± 2.30 and 589.31 ± 17.52 Bqkg-1, respectively. The measured mean activity of these radionuclides in all water samples was found to be below minimum detectable activity. The measured mean activity of 226Ra, 232Th and 40K in vegetation samples was 19.92 ± 3.09, 25.36 ± 8.11 and 4982.94 ± 85.68 Bqkg-1, respectively. No anthropogenic 137Cs was detected in these environmental samples. Mean radium equivalent activity (Raeq), external radiation hazard index (Hex), internal radiation hazard index (Hin) and absorbed dose rate (D) for the area under study were determined as 142.92 Bqkg-1, 0.38, 0.47 and 66.47 nGyh-1, respectively. The annual effective dose equivalent (AEDE) varied in the range from 0.03 to 0.12 mSvy-1. It is concluded that the surveyed area do not pose any significant radiological risk to the population and environment. 展开更多
关键词 High PURITY GERMANIUM Detector RADIUM THORIUM POTASSIUM RADIUM Equivalent Activity radiation HAZARD Indices and Environment Measure-ment
下载PDF
Analysis of The Current Cituation of Solar Radiation Measurement
6
作者 Chen Xi 《Instrumentation》 2017年第1期32-36,共5页
This paper mainly discusses the development status of solar radiation measurement technology,it expounds the relevant content of the current world radiation measurement datum and its standardization. Article the direc... This paper mainly discusses the development status of solar radiation measurement technology,it expounds the relevant content of the current world radiation measurement datum and its standardization. Article the direct radiation from the sun,the main measuring principle of total radiation and scattering radiation,this paper discusses the different types of radiation survey measuring elements,measuring range,emphasis and the current widespread use of measurement instruments. The development trend of future solar radiation measurement is put forward,and it is emphasized that nanotechnology and spectrum technology will become the focus of solar radiation instrument research and development. 展开更多
关键词 Solar radiation Direct radiation Scattered radiation Measuring Instrument
下载PDF
The definition analyses of radiation temperature measurement area
7
作者 Fu Tairan Cheng Xiaofang Zhong Maohua 《Engineering Sciences》 EI 2008年第2期42-45,共4页
In the research of primary spectrum pyrometry, this paper discussed the definition problem of radiation temperature measurement area based on the measurement coordinates. For the linear spectrum emissivity model and i... In the research of primary spectrum pyrometry, this paper discussed the definition problem of radiation temperature measurement area based on the measurement coordinates. For the linear spectrum emissivity model and improved monotonic spectrum emissivity model, the characteristics of radiation temperature measurement area restricted by the measurement coordinates were theoretically analyzed, through the investigations of the temperature and emissivity coordinate axes. Choosing the specific primary spectrum pyrometer as an example in applications, the theoretical area of radiation temperature measurement of this pyrometer was given and it was verified through blackbody experiments. The discussions of this paper will provide the necessary foundation for the theory research development of primary spectrum pyrometry and the realization of technical applications. 展开更多
关键词 辐射温度测量 光谱发射率 测量坐标系 辐射高温计 测温技术 发射模型 应用程序 基础理论
下载PDF
Measurements of non-equilibrium and equilibrium temperature behind a strong shock wave in simulated martian atmosphere 被引量:4
8
作者 Xin Lin Xi-Long Yu +3 位作者 Fei Li Shao-Hua Zhang Jian-Guo Xin Xin-Yu Zhang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2012年第5期1296-1302,共7页
Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- reso... Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- resolved spectra of the Av = 0 sequence of the B^2∑^+ → X^2∑^+ electronic transition of CN have been observed through optical emission spectroscopy (OES). A new method, which is based on fitting high resolution spectrum for rotational and vibrational temperatures measurement, is proposed to diag- nose temperature distribution behind the shock wave. It is estimated that the current scheme has the maximum deviation less than 8% (lσ) for vibrational temperature measurement through detailed analysis of the influence of the uncertainties of spectroscopic constants and spectral resolution. Radiation structure of the shock layer, including induction, relaxation and equilibrium process, and corresponding rotational and vibrational temperatures are obtained through time gating OES diagnostics with sub-microsecond temporal resolution. The present extensive results will strongly benefit the reaction rate estimation and computational fluid dynamics (CFD) code validation in high enthalpy Mars reentry chemistry. 展开更多
关键词 radiation measurements - Shock wave Marsre-entry Rotational temperature Vibrational temperature
下载PDF
Estimation of Hourly and Daily Global Solar Radiation at Clear Days Using an Approach Based on Modified Version of Gaussian Distribution 被引量:4
9
作者 S.M EI shazly 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 1996年第3期349-358,共10页
The performance of two models,Jam and Baig,based on the modified version of Gaussian distribution function in estimating the daily total of global solar radiation and its distribution through the hours of the day from... The performance of two models,Jam and Baig,based on the modified version of Gaussian distribution function in estimating the daily total of global solar radiation and its distribution through the hours of the day from sunrise to sunset al any clear day is evaluated with our own measured data in the period from June 1992 to May 1993 in Qena Egypt The results show a high relative deviation of calculated values from measured ones,especially for Jain model,in the most hours of the day,except for those near to local noon.This misfit behavior is quite obvious in the early morning and late afternoon A new approach has been proposed in this paper to estimate the daily and hourly global solar radiation This model performs with very high accuracy on the recorded data in our region.The validity of this approach was verified with new measurements in some clear days in June and August 1994.The resultant very low relative deviation of the calculated values of global solar radiation from the measured ones confirms the high performance of the approach proposed in this work 展开更多
关键词 Glohal solar radiation . measurements Models Gaussian distribution function Statistical treatment
下载PDF
Simultaneous estimation of aerosol optical constants and size distribution from angular light-scattering measurement signals 被引量:3
10
作者 贺振宗 梁栋 +1 位作者 毛军逵 韩省思 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第5期564-572,共9页
The angular light-scattering measurement(ALSM) method combined with an improved artificial bee colony algorithm is introduced to determine aerosol optical constants and aerosol size distribution(ASD) simultaneousl... The angular light-scattering measurement(ALSM) method combined with an improved artificial bee colony algorithm is introduced to determine aerosol optical constants and aerosol size distribution(ASD) simultaneously. Meanwhile, an optimized selection principle of the ALSM signals based on the sensitivity analysis and principle component analysis(PCA)is proposed to improve the accuracy of the retrieval results. The sensitivity analysis of the ALSM signals to the optical constants or characteristic parameters in the ASD is studied first to find the optimized selection region of measurement angles. Then, the PCA is adopted to select the optimized measurement angles within the optimized selection region obtained by sensitivity analysis. The investigation reveals that, compared with random selection measurement angles, the optimized selection measurement angles can provide more useful measurement information to ensure the retrieval accuracy. Finally,the aerosol optical constants and the ASDs are reconstructed simultaneously. The results show that the retrieval accuracy of refractive indices is better than that of absorption indices, while the characteristic parameters in ASDs have similar retrieval accuracy. Moreover, the retrieval accuracy in studying L-N distribution is a little better than that in studying Gamma distribution for the difference of corresponding correlation coefficient matrixes of the ALSM signals. All the results confirm that the proposed technique is an effective and reliable technique in estimating the aerosol optical constants and ASD simultaneously. 展开更多
关键词 angular light-scattering measurement method aerosol optical constants aerosol size distribution inverse radiation problem
下载PDF
Spectral measurements of hypervelocity flow in an expansion tunnel 被引量:2
11
作者 C.K.Yuan K.Zhou +2 位作者 Y.F.Liu Z.M.Hu Z.L.Jiang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2019年第1期24-31,I0002,共9页
Atmospheric reentry vehicles and planetary probes fly through the atmosphere at hypervelocity speed. At such speed, there is a significant proportion of heat load to the vehicle surface due to radiative heating. Accur... Atmospheric reentry vehicles and planetary probes fly through the atmosphere at hypervelocity speed. At such speed, there is a significant proportion of heat load to the vehicle surface due to radiative heating. Accurate prediction needs a good knowledge of the radiation spectrum properties. In this paper, a high-speed camera and spectrograph coupled to an intensified charge-coupled device have bee n impleme nted to inv estigate the rad i at io n flow over a semi-cylinder model. The experiments were carried out in the JF16 expansi on timnel with secondary shock velocity of 7.9 km·s^-1. Results show that the emissio n spectrum comprises several atomic lines and molecular band systems. We give detailed data of the radiation spectrum, shock shape, shock detached distance and radiation intensity varying with space and wavelength. This valuable experimental dataset will be helpful to validate computational fluid dynamics codes and radiation models, which equates to increased prediction accuracy of radiation heating. Also, some suggestions for spectral measurement in hypervelocity flow field were list in the end. 展开更多
关键词 SPECTRAL measurement HYPERVELOCITY FLOW radiation EXPANSION TUNNEL
下载PDF
Application study of the awning measure to obstruct solar radiation in permafrost regions on the Qinghai-Tibet Plateau 被引量:3
12
作者 WenJie Feng ZhiZhong Sun +3 位作者 Zhi Wen GuoYu Li Ze Zhang WenBing Yu 《Research in Cold and Arid Regions》 2012年第2期121-126,共6页
With globe warming, road safety will change dramatically, especially within the Qinghai-Tibet Plateau permafrost regions. Because of higher elevation and better almospheric transparency, the Qinghai-Tibet Plateau has ... With globe warming, road safety will change dramatically, especially within the Qinghai-Tibet Plateau permafrost regions. Because of higher elevation and better almospheric transparency, the Qinghai-Tibet Plateau has stronger radiation than other regions, which can change the daily variation of ground surface temperature on the Plateau. The awning measure (shading board) is one of the actively protected permafrost measures, which was adopted along the Qinghai-Tibet railway and highway and the Qing-Kang Highway in China. Field test results show that embankment surface month mean net radiation is 60-130 W/m2, but the value is below 20 W/m2 under the shading board, and the reducing level of naRn-al net radiation is 80%-90%. The shading board reduced the heat flow entering into the embankment by 80%,90% or more, with heat entering into the soil on the common embankment, but emitting from the embankment under the shading board. At the same time, ground surface temperature under the shading board is 6-8 ℃ lower than the exposed embankment. Test results show that the shading board measure can rapidly and effectively reduce net radiation and heat flow into the embankment, decrease embankment surface and interior temperature, effectively delay increase rate of soil temperature under globe warming, ensure stability and safety of the embankment, and guarantee unblocked road projects in cold and permafrost regions. 展开更多
关键词 PERMAFROST sunshading (awning) measure EMBANKMENT net radiation heat flow
下载PDF
Preliminary Report on the Indoor Electromagnetic Radiation in a Municipality of Western P.R. China: Up-to-Now Still within the Range 被引量:1
13
作者 Tingting Fu Yu Chen +1 位作者 Lingli Han Qizhong Qin 《Journal of Electromagnetic Analysis and Applications》 2012年第5期199-205,共7页
Objective: This study is designed to measure the current level of Indoor Electromagnetic Radiation (IER) in Chongqing, a municipality of western P.R. China, on which further epidemiological investigation on the relati... Objective: This study is designed to measure the current level of Indoor Electromagnetic Radiation (IER) in Chongqing, a municipality of western P.R. China, on which further epidemiological investigation on the relation between the level of IER and certain health effects could be based. Methods: 118 Households in 4 urban residential districts in Chongqing were randomly selected. The IER intensity was measured in each household’s living room at different frequencies under three different conditions. Results: The average electric field intensity measured at the frequency range of 1 MHz- 40 GHz was within the guidelines set by the International Commission on Non Ionizing Radiation Protection (ICNIRP). The electromagnetic field intensity measured at other frequencies were at the lowest range of the acceptable values. The average electric field intensity at the frequency range of 5 Hz - 1 kHz was higher at a standing posture than at a sitting posture with domestic appliances turned off in both cases (P < 0.01). Conclusion: The indoor electromagnetic radiation in Chongqing currently is still within the recommended public exposure limit set by ICNIRP. 展开更多
关键词 HOUSEHOLD Appliances INDOOR ELECTROMAGNETIC radiation measurement
下载PDF
Radiation of lamp and optimized experiment using artificial light in the Arctic Ocean 被引量:1
14
作者 赵进平 David Barber +2 位作者 李涛 李淑江 李翔 《Chinese Journal of Polar Science》 2008年第2期249-260,共12页
A winter optical experiment by an artificial lamp was conducted in the Amundsen Bay of Arctic Ocean from November of 2007 to January of 2008. The radiation field emitted from an artificial lamp was measured and is int... A winter optical experiment by an artificial lamp was conducted in the Amundsen Bay of Arctic Ocean from November of 2007 to January of 2008. The radiation field emitted from an artificial lamp was measured and is introduced in this paper, and the optimized experiment project is discussed. It is demonstrated that the minimum size allowed of the lamp is determined by both the field of view ( FOV ) of optical instrument and the measuring distance from the lamp. Some problems that might influence on the experiment result often occur for a simple fluorescent lamp, such as instability, spatial nonuniformity, light divergence, effect of lamp temperature, etc. By the analysis of the light radiation, three kind of measures are proposed to control the quality of the experiment, i.e. keeping consistency of lamp size with FOV of instrument, calibrating in situ downwind, and conducting measurement in effective range. Among them, the downwind calibration is the key step to overcome most problems arose by the lamp. The experiment indicated that the reliable results can be obtained only when the optical measurement is coordinated with the radiation field of artificial lamp. The measured radiation property of the lamp was used to advise the field experiment to minimize measuring error. As the experiment by artificial lamp was the first attempt in the Arctic Ocean, the experience given by this paper is a valuable reference to the correlative studies. 展开更多
关键词 ARCTIC Artificial light experiment radiation of lamp optical measurement field of view.
下载PDF
Research on Solar Simulation System for Test of Solar Radiation Measuring Instrument 被引量:5
15
作者 ZhengRu Zhang Guoyu +3 位作者 Lyu Wenhua Yan Jiajun Su Shi Zhang Jian 《Instrumentation》 2017年第1期3-11,共9页
Since traditional solar simulators are mainly applied to spacecraft and photovoltaic industry,they are not suitable for solar radiation measuring instrument test. Therefore,a deep research is carried out on solar simu... Since traditional solar simulators are mainly applied to spacecraft and photovoltaic industry,they are not suitable for solar radiation measuring instrument test. Therefore,a deep research is carried out on solar simulators to test of solar radiation measuring instrument,so that obtain the requirements of performance test of solar radiation measuring instrument. With a combination of the requirements for national regulations of metrological verification and performance test of pyranometer and pyrheliometer,it lays emphasis on the research of design methods for improving radiation uniformity and stability of solar simulators; it also focuses on design methods of multidimensional detection workbench,which achieves different detection of solar radiation. After practical test,solar irradiation is within Φ60 mm; irradiation non-uniformity is better than ±0.8%; instability is better than ±0.72%;rotating angle precision is better than 0.09°. Then,solar simulator is used to carry out pyranometer sensitivity test,pyranometer directional response test,pyranometer tilt response test and non-linearity test for radiation instruments. Test results showthat the solar simulator meets the testing requirements of solar radiation measuring instruments. 展开更多
关键词 Solar Simulation System Irradiation Non-uniformity Irradiation Stability Solar radiation Measuring Instrument TEST
下载PDF
Synchrotrons radiation stability measurement and improvement 被引量:2
16
作者 Tang Siwei Yin Chongxian Liu Dekang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2012年第1期7-9,共3页
In the 3rd generation synchrotron light source,beside the orbit,air disturbance and ground vibration also could affect the position stability of photon beam in synchrotrons radiation measurement.In the condition of im... In the 3rd generation synchrotron light source,beside the orbit,air disturbance and ground vibration also could affect the position stability of photon beam in synchrotrons radiation measurement.In the condition of implementation of orbit feedback system at SSRF,the measured position stability of photon beam in synchrotrons radiation measurement station was presented in this paper.And then the improvement methods of position stability of photon beam were discussed.Finally the measured result was shown when the designed feedback system is implemented to improve the position stability of photon beam. 展开更多
关键词 同步加速器辐射 稳定性测试 同步辐射光源 测量位置 辐射测量 反馈系统 光子束 地面震动
下载PDF
Analysis of the blackbody-radiation shift in an ytterbium optical lattice clock
17
作者 徐艺琳 徐信业 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第10期119-127,共9页
We accurately evaluate the blackbody-radiation shift in a171 Yb optical lattice clock by utilizing temperature measurement and numerical simulation. In this work. three main radiation sources are considered for the bl... We accurately evaluate the blackbody-radiation shift in a171 Yb optical lattice clock by utilizing temperature measurement and numerical simulation. In this work. three main radiation sources are considered for the blackbody-radiation shift, including the heated atomic oven, the warm vacuum chamber, and the room-temperature vacuum windows. The temperatures on the outer surface of the vacuum chamber are measured during the clock operation period by utilizing seven calibrated temperature sensors. Then we infer the temperature distribution inside the vacuum chamber by numerical simulation according to the measured temperatures. Furthermore, we simulate the temperature variation around the cold atoms while the environmental temperature is fluctuating. Finally, we obtain that the total blackbody-radiation shift is -1.289(7)Hz with an uncertainty of 1.25×10;for our;Yb optical lattice clock. The presented method is quite suitable for accurately evaluating the blackbody-radiation shift of the optical lattice clock in the case of lacking the sensors inside the vacuum chamber. 展开更多
关键词 optical lattices blackbody radiation shift temperature measurement finite element analysis
下载PDF
Study of Luminous Emission from a Coaxial Plasma Discharge Device in the Presence of External Transverse Magnetic Field
18
作者 Tarek M. Allam Hanaa A. El-Sayed Hanaa M. Soliman 《Energy and Power Engineering》 2011年第4期444-449,共6页
The experimental investigations in this paper are focused on the study of luminous radiation emission from coaxial plasma discharge device and the effect of applied transverse magnetic field Btr on it. The experiment ... The experimental investigations in this paper are focused on the study of luminous radiation emission from coaxial plasma discharge device and the effect of applied transverse magnetic field Btr on it. The experiment was done in (1.5 KJ - 10 KV) coaxial plasma discharge device. The discharge is operated in Nitrogen gas at pressures from 1 to 2.2 torr. Helmholtz magnetic coils are placed outside the coaxial electrodes with its axis at a distance = 3 cm from the coaxial electrodes muzzle, then Btr with a maximum induction ≈ 0.85 T is applied perpendicularly to the expanded plasma from the coaxial electrodes muzzle. The diagnostics used in the measurements include a Rogowsky coil and a photomultiplier tube equipped with light collimator. The experimental results showed that the maximum intensity of luminous radiation is detected at axial distance (side view) z = 8 cm and gas pressure, P = 2.2 torr. It also showed that the maximum value of axial luminous plasma zone velocity = 2.383 × 106 cm/s at z = 11 cm and P = 1.4 torr. In mode of presence of external Btr, the investigations have shown that, at P = 1.4 torr the maximum intensity of luminous radiation (detected at end-view position) is reduced by 17%, the full width at half maximum, FWHM of luminous radiation signal is increased by 40 times, while the luminous radiation signal is delayed by ta = 438 μs. In two modes of operation ta and FWHM have approximately a minimum values at P = 1.4 torr. 展开更多
关键词 COAXIAL DISCHARGE luminous radiation TRANSVERSE Magnetic Field Energy LOSSES
下载PDF
Infrared radiation method for measuring ice segregation temperature of artificially frozen soils 被引量:3
19
作者 Zhou Guoqing Zhang Qi +1 位作者 Xu Zhiwei Zhou Yang 《International Journal of Mining Science and Technology》 2012年第1期35-40,共6页
In order to study the evolution of the freezing fringe and final lenses of frost susceptible soils and advance the understanding of frost heave and mechanism of frost heave control, we used an open one-dimensional fro... In order to study the evolution of the freezing fringe and final lenses of frost susceptible soils and advance the understanding of frost heave and mechanism of frost heave control, we used an open one-dimensional frost heave test system of infrared radiation technology, instead of a traditional thermistor method. Temperatures of the freezing fringe and segregated ice were measured in a non-contact mode. The results show that accurate and precise temperatures of ice segregation can be obtained by infrared thermal imaging systems. A self-developed inversion program inverted the temperature field of frozen soils. Based on our analysis of temperature variation in segregated ice and our study of the relationship between temperature and rate of ice segregation in cooling and warming processes during intermittent freezing, the mechanism of decreasing frost heave of frozen soils by controlling the growth of final lenses with an intermittent freezing mode, can be explained properly. 展开更多
关键词 温度测量 人工冻土 红外辐射 红外热成像系统 冻结过程 测试系统 辐射技术
下载PDF
An Improved Method for Correction of Air Temperature Measured Using Different Radiation Shields
20
作者 CHENG Xinghong SU Debin +6 位作者 LI Deping CHEN Lu XU Wenjing YANG Meilin LI Yongcheng YUE Zhizhong WANG Zijing 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2014年第6期1460-1468,共9页
The variation of air temperature measurement errors using two different radiation shields (DTR502B Vaisala,Finland,and HYTFZ01,Huayun Tongda Satcom,China) was studied.Datasets were collected in the field at the Daxi... The variation of air temperature measurement errors using two different radiation shields (DTR502B Vaisala,Finland,and HYTFZ01,Huayun Tongda Satcom,China) was studied.Datasets were collected in the field at the Daxing weather station in Beijing from June 2011 to May 2012.Most air temperature values obtained with these two commonly used radiation shields were lower than the reference records obtained with the new Fiber Reinforced Polymers (FRP) Stevenson screen.In most cases,the air temperature errors when using the two devices were smaller on overcast and rainy days than on sunny days; and smaller when using the imported rather than the Chinese shield.The measured errors changed sharply at sunrise and sunset,and reached maxima at noon.Their diurnal variation characteristics were,naturally,related to changes in solar radiation.The relationships between the record errors,global radiation,and wind speed were nonlinear.An improved correction method was proposed based on the approach described by Nakamura and Mahrt (2005) (NM05),in which the impact of the solar zenith angle (SZA) on the temperature error is considered and extreme errors due to changes in SZA can be corrected effectively.Measurement errors were reduced significantly after correction by either method for both shields.The error reduction rate using the improved correction method for the Chinese and imported shields were 3.3% and 40.4% higher than those using the NM05 method,respectively. 展开更多
关键词 radiation shield measurement error impacts of solar zenith angle improved correction method
下载PDF
上一页 1 2 87 下一页 到第
使用帮助 返回顶部