期刊文献+
共找到1,310篇文章
< 1 2 66 >
每页显示 20 50 100
Accuracy of axial length measurements from immersion B-scan ultrasonography in highly myopic eyes 被引量:9
1
作者 Qing-Hua Yang Bing Chen +2 位作者 Guang-Hua Peng Zhao-Hui Li Yi-Fei Huang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第3期441-445,共5页
AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHOD... AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHODS:Immersion B-scan,contact A-scan ultrasonography(contact A-scan),and the IOLMaster were used to preoperatively measure the AL in 102 eyes from 102 patients who underwent phacoemulsification and IOL implantation.Patients were divided into two groups according to the AL:one containing patients with22 mm≤AL【26 mm(group A)and the other containing patients with AL≥26 mm(group B).The mean error(ME)was calculated from the difference between the AL measurement methods predicted refractive error and the actual postoperative refractive error.RESULTS:Ingroup A,ALs measured byimmersion Bscan(23.48±1.15)didn’t differ significantly from those measured by the IOLMaster(23.52±1.17)or from those by contact A-scan(23.38±1.20).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.090±0.397 D)didn’t differ significantly from those of IOLMaster(-0.095±0.411 D)and contact A-scan(-0.099±0.425 D).In group B,ALs measured by immersion B-scan(27.97±2.21 mm)didn’t differ significantly from those of the IOLMaster(27.86±2.18 mm),but longer than those measured by Contact A-scan(27.75±2.23 mm,P=0.009).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.635±0.157 D)didn’t differ significantly from those of the IOLMaster(-0.679±0.359 D),but differed significantly from those of contact A-scan(-0.953±1.713 D,P=0.028).CONCLUSION:ImmersionB-scanexhibitsmeasurement accuracy comparable to that of the IOLMaster,and is thus a good alternative in measuring AL in eyes with high myopia when the IOLMaster can’t be used,and it is more accurate than the contact A-scan. 展开更多
关键词 axial length measurement IMMERSION ULTRASONOGRAPHY high myopia
下载PDF
Precise measurement method of optical fiber length based on timestamp technique
2
作者 缪新育 周波 周峰 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2016年第3期302-306,共5页
A measurement method of optical fiber length using timestamp technique is demonstrated. Based on IEEE1588 precise clock synchronization protocol, the principle that time delay asymmetry on two path results in synchr... A measurement method of optical fiber length using timestamp technique is demonstrated. Based on IEEE1588 precise clock synchronization protocol, the principle that time delay asymmetry on two path results in synchronization time deviation is used, and the difference between two-path delays could be deduced by measuring the synchronization time deviation reversely. Then the length of optical fiber on one path could be calculated if that on the other path is known Due to the fact that the path of Sync and Delay_Req message is symmetric, the optical pulse dispersion and the asymmetry of photoelectric detector performance on two paths are averaged by exchanging two optical fibers. The time difference between master and slave clocks is eliminated by sharing the same time base. At last, the lengths of two single-mode optical fibers are measured with the uncertainty of 0. 578 m for 3 227. 722 m and 0. 758 m for 25 491. 522 m, respectively. Thus this method has high precision and long range. 展开更多
关键词 TIMESTAMP fiber length measurement time synchronization
下载PDF
Significance of Axial Length Monitoring in Children with Congenital Cataract and Update of Measurement Methods 被引量:11
3
作者 Jiao Zhan Haotian Lin +2 位作者 Xinyu Zhang Weirong Chen Yizhi Liu 《Eye Science》 CAS 2013年第2期95-102,共8页
Congenital cataract is the main cause of blindness in children, with significantly varying treatment effects. The development of axial length is an important factor that affects the prognosis of these children.However... Congenital cataract is the main cause of blindness in children, with significantly varying treatment effects. The development of axial length is an important factor that affects the prognosis of these children.However,when compared with the eyes of normal children,the mechanism of growth of the axial length is so complicated that the reported findings differ significantly in terms of the measuring apparatus,assessment methods,and statistical outcome,making the rule of axial length development still unclear. In this paper, we first review the process of axial length development in normal healthy children and compare different hypotheses about certain factors that could affect the development of axial length. The results of some current research about the characteristics of axial length development in congenital cataract children are then reviewed. Lastly, the advantages and disadvantages of current axial length measurements methods are compared and analyzed.The purpose of this review is to improve our understanding of the complexity and importance of axial length development and to suggest better use of axial length monitoring measurements in congenital cataract children for pediatric ophthalmologists,with the hope of offering assistance that will enhance long-term therapeutic effects for these children. 展开更多
关键词 轴向长度 测量方法 白内障 先天性 儿童 监测 治疗效果 测量设备
下载PDF
A linear crack length measurement method for railway bridges based on calibration points fitting 被引量:1
4
作者 WANG Ji-wu YU Peng-fei +1 位作者 LUO Hai-bao YU Pei-long 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2020年第2期118-125,共8页
For the linear crack skeleton of railway bridges with irregular strike,it is difficult to accurately express the crack contour feature by using a single smoothing fitting algorithm.In order to improve the measurement ... For the linear crack skeleton of railway bridges with irregular strike,it is difficult to accurately express the crack contour feature by using a single smoothing fitting algorithm.In order to improve the measurement accuracy,a polynomial curve fitting was proposed,which used the calibration point of crack contour as the boundary point,and then put them all together to produce a continuous contour curve to achieve the crack length measurement.The method was tested by measuring the linar cracks with different shapes.It is shown that this proposed algorithm can not only solve the jagged problem generated in the crack skeleton extraction process,but also improve the crack length measurement accuracy.The relative deviation is less than 0.15,and the measurement accuracy is over 98.05%,which provides a more effective means for the crack length measurement in railway bridges. 展开更多
关键词 crack skeleton length measurement calibration point polynomial fitting railway bridge
下载PDF
Injection transient study using a two-frequency bunch length measurement system at the SSRF 被引量:7
5
作者 Li-Wu Duan Yong-Bin Leng +1 位作者 Ren-Xian Yuan Zhi-Chu Chen 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第7期37-42,共6页
The bunch length can be measured by comparison of two frequency components of a synchrotron beam signal.An online bunch length measurement system has been implemented based on this method.Working frequencies of 3 GHz ... The bunch length can be measured by comparison of two frequency components of a synchrotron beam signal.An online bunch length measurement system has been implemented based on this method.Working frequencies of 3 GHz and 500 MHz were selected,and the raw data was acquired by digital oscilloscope and was resampled and analyzed using the MATLAB software platform at bunch-by-bunch rate.The constructed system was employed to study the bunch length synchronous oscillation phenomenon during injection.The beam experiments demonstrated a time resolution of less than 0.5 ps. 展开更多
关键词 长度测量系统 束团长度 注射过程 双频 光源 上海 瞬态 Matlab
下载PDF
Automatic Detection and Measurement of Fetal Biparietal Diameter and Femur Length —Feasibility on a Portable Ultrasound Device
6
作者 Naiad Hossain Khan Eva Tegnander +3 位作者 Johan Morten Dreier Sturla Eik-Nes Hans Torp Gabriel Kiss 《Open Journal of Obstetrics and Gynecology》 2017年第3期334-350,共17页
An automatic method able to recognize a presented section through the biparietal plane of the fetal head and a section through the fetal femur in ultrasound images is developed. Once the correct anatomical section for... An automatic method able to recognize a presented section through the biparietal plane of the fetal head and a section through the fetal femur in ultrasound images is developed. Once the correct anatomical section for measurement is identified by the machine, the placement of the measurement calipers is automatically determined by fitting an active contour model to the structure of interest. The fetal biparietal diameter (BPD) and femur length (FL) are then measured automatically. The validation data set contained 167 and 197 B-mode images for BPD and FL measurements, respectively. The images were acquired using 4 different ultrasound scanners, which resulted in varied image quality and gain settings. The mean gestational age (GA) of the fetuses was 19.4 weeks, range 16 to 41 weeks. A measurement success rate of 90% was achieved for both BPD and FL. The correlation coefficients between the manual and automatic measurements were 0.995 (BPD) and 0.967 (FL), mean errors were 0.5 mm (BPD) and -1.7 mm (FL) and error range with 95% confidence interval (CI) were ﹣3.8 - 4.8 mm (BPD) and ﹣11.4 - 8.1 mm (FL). The automatic measurement results were consistent in both high and low gain settings. The intraclass correlation coefficients between manual and automatic measurements were 0.995 (95% CI;0.981 - 0.999) for BPD in high gain, 1.0 (95% CI;0.998 - 1.0) for BPD in low gain, 0.998 (95% CI;0.991 - 0.999) for FL in high gain and 0.999 (95% CI;0.996 - 1.0) for FL in low gain settings. The method was implemented on a prototype, portable ultrasound machine designed to be used in low- and middle-income countries (LMIC). The overall performance of the method supports our hypothesis that automated methods can be used and are beneficial in a clinical setting. 展开更多
关键词 FETAL DATING Biparietal DIAMETER FEMUR length PORTABLE Ultrasound Machine Automatic measurement
下载PDF
Variations of OCT measurements corrected for the magnification effect according to axial length and refractive error in children
7
作者 Inmaculada Bueno-Gimeno Enrique España-Gregori +2 位作者 Andres Gene-Sampedro Juan Carlos Ondategui-Parra Carlos J.Zapata-Rodriguez 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2018年第1期123-137,共15页
Purpose:The aim of this paper was to examine the distribution of macular,retinal nerve fiber layer(RNFL)thickness and optic disc parameters of myopic and hyperopic eyes in comparison withemmetropic control eyes and to... Purpose:The aim of this paper was to examine the distribution of macular,retinal nerve fiber layer(RNFL)thickness and optic disc parameters of myopic and hyperopic eyes in comparison withemmetropic control eyes and to investigate their variation according to axial length(AL)andspherical equivalent(SE)in healthy children.Methods:This study included 293 pairs of eyes of 293children(145 boys and 148 girks),ranging in age from 6 to 17 years,Subjects were dividedaccording to SE in control(emmetropia,99 children),myopia(100 children)and hyperopia(94children)groups and according to axial AL in 68 short(<22.00 mm,68),medium(from≥22.00 mmto 25.00 mm,189)and long eyes(>25.00 mm,36).Macular parameters,RNFL thickness and opticdisc morphology were assessed by the Cirrus^(TM) HD-OCT.AL was measured using the IOL-Mastersystem.Littmann's formula was used for calculating the corrected AL-related ocular magnification.Results Mean age(±SD)was 10.84±3.05 years;mean(±SD)SE was+0.14±0.51 D(range from8.75 to+8.25 D)and mean AL(±SD)was 23.12±1.49.Average RNFL thickness,averagemacular thickness and macular volume decreased as AL and myopia increased.No correlationsbetween AL/SE and optic disc parameters were found after correcting for magnification effect.Conclusions:AL and refractive error affect measurements of macular and RNFL thickness inhealthy children.To make a correct interpretation of ocT measurements,ocular magnificationeffect should be taken into account by clinicians or OCT manufacturers. 展开更多
关键词 Axial length refractive error CHILDREN OCT measurements magnification fect
下载PDF
Precise Optical Fiber Length Measurement System Based on Fresnel Reflection
8
作者 Firat Ertac Durak Arif Basgumus +1 位作者 Serif Ali Sadik Ahmet Altuncu 《Journal of Electrical Engineering》 2016年第3期128-132,共5页
In this study, a precise optical fiber length measurement system is proposed. The measurement technique is based on the measurement of relative Fresnel reflected light intensity in a test fiber. Time delayed optical r... In this study, a precise optical fiber length measurement system is proposed. The measurement technique is based on the measurement of relative Fresnel reflected light intensity in a test fiber. Time delayed optical reflected pulses are obtained from a single nanosecond pulse injected at the input due to the difference in lengths of the reference and test fibers. The lengths of the different optical fibers have been measured with this technique with high resolution and fast response time. The measured results show that, the proposed technique has a comparable performance with the well-known length measurement systems. 展开更多
关键词 Fresnel reflection nanosecond pulse optical fiber length measurement time delayed pulses.
下载PDF
Beak Measurements of Octopus (Octopus variabilis) in Jiaozhou Bay and Their Use in Size and Biomass Estimation 被引量:2
9
作者 XUE Ying REN Yiping +4 位作者 MENG Wenrong LI Long MAO Xia HAN Dongyan MA Qiuyun 《Journal of Ocean University of China》 SCIE CAS 2013年第3期469-476,共8页
Cephalopods play key roles in global marine ecosystems as both predators and preys.Regressive estimation of original size and weight of cephalopod from beak measurements is a powerful tool of interrogating the feeding... Cephalopods play key roles in global marine ecosystems as both predators and preys.Regressive estimation of original size and weight of cephalopod from beak measurements is a powerful tool of interrogating the feeding ecology of predators at higher trophic levels.In this study,regressive relationships among beak measurements and body length and weight were determined for an octopus species(Octopus variabilis),an important endemic cephalopod species in the northwest Pacific Ocean.A total of 193 individuals(63 males and 130 females) were collected at a monthly interval from Jiaozhou Bay,China.Regressive relationships among 6 beak measurements(upper hood length,UHL;upper crest length,UCL;lower hood length,LHL;lower crest length,LCL;and upper and lower beak weights) and mantle length(ML),total length(TL) and body weight(W) were determined.Results showed that the relationships between beak size and TL and beak size and ML were linearly regressive,while those between beak size and W fitted a power function model.LHL and UCL were the most useful measurements for estimating the size and biomass of O.variabilis.The relationships among beak measurements and body length(either ML or TL) were not significantly different between two sexes;while those among several beak measurements(UHL,LHL and LBW) and body weight(W) were sexually different.Since male individuals of this species have a slightly greater body weight distribution than female individuals,the body weight was not an appropriate measurement for estimating size and biomass,especially when the sex of individuals in the stomachs of predators was unknown.These relationships provided essential information for future use in size and biomass estimation of O.variabilis,as well as the estimation of predator/prey size ratios in the diet of top predators. 展开更多
关键词 Octopus variabilis Jiaozhou Bay beak measurement body size hood length crest length
下载PDF
A New High Accuracy Measurement Method forHot Deformation of Large Structures
10
作者 丁振良 袁峰 +1 位作者 陈中 申杰 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1998年第2期17-22,共6页
This paper presents a new high accuracy measurement for hot deformation of large structure. Its princple and technological features, several key technologies and factors that affect measurement accuracy are discussed,... This paper presents a new high accuracy measurement for hot deformation of large structure. Its princple and technological features, several key technologies and factors that affect measurement accuracy are discussed, the uncertainty of measurement is analyzed, and measures to ensure accuracy are given. 展开更多
关键词 TEMPERATURE measurement length measurement HOT DEFORMATION
下载PDF
Use of Foot Measurements as Sonographic Parameter for Estimation of Fetal Age
11
作者 Bushra Abdel Malik Mohammed Ibrahim +3 位作者 Qurashi Ali Mohamed Yousef Qurain Turki Alshammari Saddig Jastaniah 《Open Journal of Medical Imaging》 2017年第4期248-262,共15页
Objectives: this research was conducted to describe the ultrasonic measurements of the foot full measurements (FFM) and their importance in the antenatal care (ANC). Material and methods: the Descriptive quantitative ... Objectives: this research was conducted to describe the ultrasonic measurements of the foot full measurements (FFM) and their importance in the antenatal care (ANC). Material and methods: the Descriptive quantitative cross-sectional study conducted in the ultrasound department at Alshaekh Mohammed Ali Fadol hospital in Omdurman locality. The study included 400 healthy Sudanese pregnant women whom in the 1st (late), 2nd and 3rd trimesters (i.e., after 10 weeks gestational age) of different parity and ages (15 years old and above);they have regular menstrual cycle and well certain of their last menstrual period and calculated date of delivery. Ultrasonographic measurement of Full Foot Length1 (FFL1), Foot Full Length2 (FFL2), and Foot Full Width (FFW) of all pregnant women were done. Sonographically we measured fetal foot from 14 to 40 weeks of gestation. Results: the study revealed that the mean FFL1 was 58.7 ± 12.9 mm. The minimum measurement was 18.8 mm, and the maximum was 89.1 mm, while the mean value of FFL2 was 53.4 ± 11.4 mm, with minimum value 17.5 mm and maximum 81.7 mm, and the mean FFW was 23.7 ± 5.1 mm, with minimum value 7.0 mm and maximum 38.0 mm. Conclusion: a strongly significant relationships were observed between (FFL1, FFL2, FFW) and gestational age (p = 0.00). However there is no significant difference between the FFL1, FFL2, and correlations with sex of embryo, residence, occupation, parity, maternal height, socioeconomic status, bleeding during this pregnancy, chronic illness, and caesarian section, moreover there are significant correlations between the FFL1, FFL2 and the (maternal age, maternal weight, and body mass index), but in the measurement of the fetal FFW there were no significant correlations with (sex of embryo, maternal age, body mass index, residence, occupation, parity, socioeconomic status, bleeding during this pregnancy, chronic illness, and caesarian section). Also there are significant correlations between the FFW and the maternal weight and height. 展开更多
关键词 GESTATIONAL Age Full FOOT measurementS FOOT Full length1 (FFL1) FOOT Full length2 (FFL2) and FOOT Full WIDTH (FFW)
下载PDF
Error Analysis for High-precision 7m Laser Measuring Machine
12
作者 赵维谦 谭久彬 +1 位作者 杨文国 赵熙萍 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1997年第3期5-9,共5页
This paper introduces a high precision 7m laser measuring instrument developedby the anthors and its operating principle,and systematically analyses the errors havinginfluence on the performance of the measuring instr... This paper introduces a high precision 7m laser measuring instrument developedby the anthors and its operating principle,and systematically analyses the errors havinginfluence on the performance of the measuring instrument.Error analysis and actualverification indicate that all the characteristics reached or exceeded the original designspecifications. 展开更多
关键词 Laser measuring machine length measurement ERROR analysis large-dimension measurement
下载PDF
Correlation between Endocervical Length in the First Trimester and Spontaneous Preterm Delivery
13
作者 Korine Camargo de Oliveira Mariana Menegon de Souza +3 位作者 Patricia Telló Dürks Maria Alexandrina Zanatta Eduardo Becker Jr. Janete Vettorazzi 《Open Journal of Obstetrics and Gynecology》 2021年第11期1608-1618,共11页
<strong>Introduction:</strong><span><span><span style="font-family:""><span style="font-family:Verdana;"> Prematurity is a public health problem in Brazil, ... <strong>Introduction:</strong><span><span><span style="font-family:""><span style="font-family:Verdana;"> Prematurity is a public health problem in Brazil, with 12% of deliveries occurring before 37 weeks of gestation. The measurement of the cervix in the second trimester is already established as a method of screening for prematurity and some studies point out advantages to start this screening in the first trimester. </span><b><span style="font-family:Verdana;">Objective:</span></b><span style="font-family:Verdana;"> To define the correlation between the length of the endocervix by transvaginal ultrasound in the first trimester (11 to 14 weeks) with spontaneous early deliveries. </span><b><span style="font-family:Verdana;">Method:</span></b><span style="font-family:Verdana;"> A prospective and observational study realized in a suplementar and private ultrasound clinic and hospital of Porto Alegre, Brazil between 2019-2020. Ultrasound screening of cervix was performed in singleton pregnancies in first and second trimester of pregnancy and correlated with age of delivery. </span><b><span style="font-family:Verdana;">Results:</span></b><span style="font-family:Verdana;"> 142 pregnant women were studied, 80% were in the first pregnancy. The average age was 33.8 years. The rate of prematurity was 18% before 37 weeks and 4% before 34 weeks. The average of cervix measured in the first and second trimesters in deliveries before 34 weeks was 32.7 mm and 29.3 mm, respectively. In term deliveries the median cervical length was 38.8 mm and 37.8 mm, respectively. When analyzing the measurements of the cervix in the second trimester, the cervix was smaller (p = 0.008) among deliveries below 34 weeks (29</span></span></span></span><span><span><span style="font-family:""> </span></span></span><span><span><span style="font-family:""><span style="font-family:Verdana;">mm) than deliveries after 37 weeks. No statistically related differences were found between preterm birth and first trimester cervix measurements. </span><b><span style="font-family:Verdana;">Conclusions</span></b><span style="font-family:Verdana;">: In this study, we did not observe a statistically significant relationship between first trimester cervix measurement and prematurity. More studies are needed to evaluate this finding. However, the measurement of the cervix in the second trimester is different from that found in the literature. This suggest</span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">s</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> a possible new cut-off point that increases the sensitivity of transvaginal ultrasound as a method of preventing prematurity.</span></span></span> 展开更多
关键词 Preterm Birth SCREENING Cervical length measurement Preterm Birth Prevention Clinic
下载PDF
Implementation and Validation of a Stride Length Estimation Algorithm,Using a Single Basic Inertial Sensor on Healthy Subjects and Patients Suffering from Parkinson’s Disease
14
作者 Benoit Sijobert Mourad Benoussaad +3 位作者 Jennifer Denys Roger Pissard-Gibollet Christian Geny Christine Azevedo Coste 《Health》 2015年第6期704-714,共11页
As low cost and highly portable sensors, inertial measurements units (IMU) have become increas-ingly used in gait analysis, embodying an efficient alternative to motion capture systems. Mean-while, being able to compu... As low cost and highly portable sensors, inertial measurements units (IMU) have become increas-ingly used in gait analysis, embodying an efficient alternative to motion capture systems. Mean-while, being able to compute reliably accurate spatial gait parameters using few sensors remains a relatively complex problematic. Providing a clinical oriented solution, our study presents a gy-rometer and accelerometer based algorithm for stride length estimation. Compared to most of the numerous existing works where only an averaged stride length is computed from several IMU, or where the use of the magnetometer is incompatible with everyday use, our challenge here has been to extract each individual stride length in an easy-to-use algorithm requiring only one inertial sensor attached to the subject shank. Our results were validated on healthy subjects and patients suffering from Parkinson’s disease (PD). Estimated stride lengths were compared to GAITRite? walkway system data: the mean error over all the strides was less than 6% for healthy group and 10.3% for PD group. This method provides a reliable portable solution for monitoring the in-stantaneous stride length and opens the way to promising applications. 展开更多
关键词 Inertial measurement Unit(IMU) Stride length Gait Analysis Parkinson’s Disease BIOLOGGING
下载PDF
北京佑安医院降低平均住院日的管理措施研究
15
作者 张志丽 曲金宁 +2 位作者 李国英 茹永聪 张月宁 《中国医药科学》 2024年第21期152-155,177,共5页
目的探讨首都医科大学附属北京佑安医院实施平均住院日管理的效果。方法首都医科大学附属北京佑安医院在2022年1月起采取建立集中预约平台、成立住院服务中心、实时沟通机制、积极开展日间手术和微创手术、深入推进临床路径和单病种管... 目的探讨首都医科大学附属北京佑安医院实施平均住院日管理的效果。方法首都医科大学附属北京佑安医院在2022年1月起采取建立集中预约平台、成立住院服务中心、实时沟通机制、积极开展日间手术和微创手术、深入推进临床路径和单病种管理、优化多学科诊疗模式等多项措施综合管控平均住院日,比较2021年1—12月和2022年1—12月病案首页数据,对全院、重点科室、前20位疾病的平均住院日相关数据进行统计分析。结果采取多措并举后,2022年1—12月全院平均住院日、重点科室平均住院日和前20位疾病平均住院日均较2021年1—12月明显下降,2022年1—12月平均住院日由9.49 d降至8.50 d。结论多部门联动后优化措施可有效缩短平均住院日。 展开更多
关键词 平均住院日 管理措施 传染病 多部门联动
下载PDF
Simulation and Error Analysis of Electro-optic Sampling Measurement of Ultrashort Electron Beam Bunch Length
16
作者 孙大睿 徐金强 唐坤 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第z1期121-123,共3页
For the development of high energy physics,it is needed to improve the performance of the relativistic electron bunch.The measurement of the ultrashort relativistic electron pulse becomes one of the key technologies.T... For the development of high energy physics,it is needed to improve the performance of the relativistic electron bunch.The measurement of the ultrashort relativistic electron pulse becomes one of the key technologies.The electro-optic sampling measurement of relativistic electron pulses is a promising method.This method is nondestructive, non-intrusive,and real-time monitoring.Distance and angles of the reference frames will cause system deviations.In this paper these system deviations are analyzed by simulation.It provides a reference for the experiment. 展开更多
关键词 electro-optic sampling ultrashort electron beam bunch measurement of electron bunch length
原文传递
面向油品参数快速计量的高精度傅里叶近红外光谱仪 被引量:2
17
作者 方旭 刘欣 +4 位作者 李琪 舒慧 张正东 程真英 李瑞君 《计量学报》 CSCD 北大核心 2024年第1期103-111,共9页
针对油品现场检测中实时性和准确度的需要,研制了一种面向油品参数快速计量的高精度傅里叶近红外光谱仪。该光谱仪采用相干长度扩增方法,可快速定位有效信号;通过驱动采集控制系统对傅里叶近红外检测光路进行100 nm等间隔的干涉调制,最... 针对油品现场检测中实时性和准确度的需要,研制了一种面向油品参数快速计量的高精度傅里叶近红外光谱仪。该光谱仪采用相干长度扩增方法,可快速定位有效信号;通过驱动采集控制系统对傅里叶近红外检测光路进行100 nm等间隔的干涉调制,最终由傅里叶逆变换解析出的吸收光谱分辨力可达3.25 cm^(-1)。用该光谱仪对汽油样品进行质量检测的结果表明:该光谱仪可在短时间内对汽油中5种物质含量进行快速计量,其最大体积误差不超过0.7%,可以满足油品参数现场计量的需求,对市场中成品油质量的监管具有重要意义。 展开更多
关键词 油品参数测量 近红外光谱仪 傅里叶逆变换 汽油 相干长度扩增法
下载PDF
调频连续波激光多路并行相干精密长度测量方法 被引量:1
18
作者 胡申博 刘俊辰 +3 位作者 余苏 杨承昱 曲兴华 张福民 《光电工程》 CAS CSCD 北大核心 2024年第3期106-114,共9页
面向航空航天等大型复杂机电系统,长度测量的需求从单独的一维位移测量发展到多目标、灵活便于拓展的多路并行测量。调频连续波激光雷达长度测量技术具备抗干扰、精度高、无合作等优势。本文基于调频连续波激光雷达技术开展多路并行相... 面向航空航天等大型复杂机电系统,长度测量的需求从单独的一维位移测量发展到多目标、灵活便于拓展的多路并行测量。调频连续波激光雷达长度测量技术具备抗干扰、精度高、无合作等优势。本文基于调频连续波激光雷达技术开展多路并行相干精密长度测量方法研究,针对传统长度测量系统存在光纤色散、辅助路光纤漂移导致长度测量精度降低问题,提出一种含有氰化氢气体吸收池的三光路马赫-曾德尔干涉测量系统,在此基础上,基于光开关结构实现精密长度多路并行测量。通过精密导轨长度测量实验结果表明,提出的方法在3.6 m长度范围内标准差不超过25μm,实现了四路并行长度测量。与商用激光干涉仪测量结果比较,多路测量结果的绝对误差不超过30μm。 展开更多
关键词 调频连续波 HCN气体吸收池 光开关 长度测量
下载PDF
流动式相对重力仪的研制与应用
19
作者 张寒 朱学毅 +3 位作者 缑小路 吴畏 仇恺 高峰 《地震科学进展》 2024年第7期466-470,共5页
地球重力场信息是进行地球物理研究的重要基础数据,对我国具有重要意义。作为陆上高精度重力测量的核心仪器,流动式相对重力仪因其技术门槛高,国内市场长期被国外产品所垄断。天津航海仪器研究所依托掌握的金属零长弹簧制备核心技术,成... 地球重力场信息是进行地球物理研究的重要基础数据,对我国具有重要意义。作为陆上高精度重力测量的核心仪器,流动式相对重力仪因其技术门槛高,国内市场长期被国外产品所垄断。天津航海仪器研究所依托掌握的金属零长弹簧制备核心技术,成功研制出流动式相对重力仪,成为国内极少数掌握该项技术的单位,可全面满足包括陆上重力基线场在内的野外测量作业要求。由天津航海仪器研究所研制的流动式相对重力仪通过了国内最具权威用户组织中国地震局的入网测评,实测重复性标准差为3.1μGal,精度为3.5μGal,分辨力优于1μGal,整体性能达到国际先进水平。 展开更多
关键词 相对重力仪 重力测量 零长弹簧 设备入网测试
下载PDF
眼轴长度与角膜曲率半径比值在儿童青少年近视评估中的效能 被引量:1
20
作者 王伟 欧盛钰 《国际眼科杂志》 CAS 2024年第8期1314-1318,共5页
目的:评估眼轴长度与角膜曲率半径比值(AL/CR)在儿童青少年近视诊断中的价值。方法:收集2022-01/2023-12在北海市第二人民医院视光门诊初次就诊的儿童青少年2182例4364眼的屈光度及眼生物学参数,并进行分析。结果:受试者工作特征曲线(RO... 目的:评估眼轴长度与角膜曲率半径比值(AL/CR)在儿童青少年近视诊断中的价值。方法:收集2022-01/2023-12在北海市第二人民医院视光门诊初次就诊的儿童青少年2182例4364眼的屈光度及眼生物学参数,并进行分析。结果:受试者工作特征曲线(ROC曲线)分析显示,AL/CR诊断近视具有更高的曲线下面积(AUC=0.925,95%CI为0.917-0.933),且AL/CR=3.053时,Youden指数最大,随着AL/CR界值变小,近视诊断的灵敏度呈升高趋势,特异度则有所下降。与筛查性近视相比,AL/CR=3.053诊断近视的灵敏度偏低,但特异度较高,尤其在远视和近视前期者中表现更明显。结论:AL/CR对于近视诊断的准确性优于眼轴长度及平均角膜曲率,且具有更高的特异度;随着AL/CR界值变小,其诊断近视的灵敏度增加,但特异度下降。在远视和近视前期者中,AL/CR对于近视诊断的特异度高于筛查性近视。 展开更多
关键词 近视 生物学测量 眼轴 轴率比 儿童青少年
下载PDF
上一页 1 2 66 下一页 到第
使用帮助 返回顶部