Phase unwrapping is one of the key roles in fringe projection three-dimensional(3D)measurement technology.We propose a new method to achieve phase unwrapping in camera array light filed fringe projection 3D measuremen...Phase unwrapping is one of the key roles in fringe projection three-dimensional(3D)measurement technology.We propose a new method to achieve phase unwrapping in camera array light filed fringe projection 3D measurement based on deep learning.A multi-stream convolutional neural network(CNN)is proposed to learn the mapping relationship between camera array light filed wrapped phases and fringe orders of the expected central view,and is used to predict the fringe order to achieve the phase unwrapping.Experiments are performed on the light field fringe projection data generated by the simulated camera array fringe projection measurement system in Blender and by the experimental 3×3 camera array light field fringe projection system.The performance of the proposed network with light field wrapped phases using multiple directions as network input data is studied,and the advantages of phase unwrapping based on deep learning in light filed fringe projection are demonstrated.展开更多
In this paper, we present a method based on self-mixing interferometry combing extreme learning machine for real-time human blood pressure measurement. A signal processing method based on wavelet transform is applied ...In this paper, we present a method based on self-mixing interferometry combing extreme learning machine for real-time human blood pressure measurement. A signal processing method based on wavelet transform is applied to extract reversion point in the self-mixing interference signal, thus the pulse wave profile is successfully reconstructed. Considering the blood pressure values are intrinsically related to characteristic parameters of the pulse wave, 80 samples from the MIMIC-II database are used to train the extreme learning machine blood pressure model. In the experiment, 15 measured samples of pulse wave signal are used as the prediction sets. The results show that the errors of systolic and diastolic blood pressure are both within 5 mm Hg compared with that by the Coriolis method.展开更多
基金the National Natural Science Foundation of China(No.61905178)the Science&Technology Development Fund of Tianjin Education Commission for Higher Education(No.2019KJ021)the Natural Science Foundation of Tianjin(No.18JCQNJC71100)。
文摘Phase unwrapping is one of the key roles in fringe projection three-dimensional(3D)measurement technology.We propose a new method to achieve phase unwrapping in camera array light filed fringe projection 3D measurement based on deep learning.A multi-stream convolutional neural network(CNN)is proposed to learn the mapping relationship between camera array light filed wrapped phases and fringe orders of the expected central view,and is used to predict the fringe order to achieve the phase unwrapping.Experiments are performed on the light field fringe projection data generated by the simulated camera array fringe projection measurement system in Blender and by the experimental 3×3 camera array light field fringe projection system.The performance of the proposed network with light field wrapped phases using multiple directions as network input data is studied,and the advantages of phase unwrapping based on deep learning in light filed fringe projection are demonstrated.
基金supported by the National Natural Science Foundation of China (No.61675174)the Natural Science Foundation of Fujian Province (No.2020J01705)。
文摘In this paper, we present a method based on self-mixing interferometry combing extreme learning machine for real-time human blood pressure measurement. A signal processing method based on wavelet transform is applied to extract reversion point in the self-mixing interference signal, thus the pulse wave profile is successfully reconstructed. Considering the blood pressure values are intrinsically related to characteristic parameters of the pulse wave, 80 samples from the MIMIC-II database are used to train the extreme learning machine blood pressure model. In the experiment, 15 measured samples of pulse wave signal are used as the prediction sets. The results show that the errors of systolic and diastolic blood pressure are both within 5 mm Hg compared with that by the Coriolis method.
基金Supported by the National Science Foundation of USA ( the most recent one being num bered PHY- 970 4 5 2 0 ) and by the U niversities of Missouri and Nebraska ( U SA )