The application of non-suppressed ion chromatography for monitoring of trace elements in air particulate matter was studied in the present investigation. The results indicate that the use of microwave acid digestion m...The application of non-suppressed ion chromatography for monitoring of trace elements in air particulate matter was studied in the present investigation. The results indicate that the use of microwave acid digestion method is superior in comparison with the conventional thermal acid digestion method as it leads to higher recovery, better reproducibility, lower volatility loss, better protection against environmental contamination and much less digestion time (5 minutes vs. 24 hours). The use of eluent as extractant is shown to reduce the water dip problem in the chro-matogram. The addition of chelating agent in the eluent coupled with UV detection is shown to provide satisfactory chromatographic separation and good sensitivity for the analysis of transition metals present in the air particulate matter. Using the U.S. National Bureau of Standards Reference Material 1648 Urban Particulate Matter as standard for checking, the analytical procedure is shown to give good recovery and reproducibility for the detection of the following cations and anions in air particulate matter: Fe2 Cu, Mn, Pb, Zn, Mg, Na, HN4+, Cl-, NO3- and SO42-. Field test was also performed to check the applicability of the method and the results obtained were discussed in the present paper.展开更多
A method has been established to study the competing binding of metal ions with protein by a combined technique of microdialysis with high performance liquid chromatography (HPLC). Ni2+, Cd2+, Zn2+, Cu2+ and human ser...A method has been established to study the competing binding of metal ions with protein by a combined technique of microdialysis with high performance liquid chromatography (HPLC). Ni2+, Cd2+, Zn2+, Cu2+ and human serum albumin (HSA) were chosen as model metal ions and protein. The experimental results show that Ni2+ and Cu2+ share a common primary binding site on HSA, and Zn2+ and Cd2+ share a different common primary binding site from them, but there is a common multi-metal binding site for all of those four metal ions. This method show advantages of fast sampling, easily to be operated and especially to be useful when ideal spectroscopic probes are not available for the study of interaction between protein and metal ions.展开更多
Protein kinase substrate phage (PKS phage) was constructed by fusing the substrate recognition consensus sequence of cAMP-dependent protein kinase (cAPK) with bacteriophage minor coat protein g3p and by dis-playing it...Protein kinase substrate phage (PKS phage) was constructed by fusing the substrate recognition consensus sequence of cAMP-dependent protein kinase (cAPK) with bacteriophage minor coat protein g3p and by dis-playing it on the surface of filamentous bacteriophage fd. Phosphorylation in vitro by cAPK showed a unique labelled band of approximately 60 ku, which was consistent with the molecular weight of the PKS-g3p fusion protein. Some weakly phosphorylated bands for both PKS phage and wild-type phage were also observed. Phage display random 15-mer peptide library phosphorylated by cAPK was selected with ferric (Fe3+ ) chelalion affinity resin. After 4 rounds of screening, phage clones were picked out to determine the displayed peptide sequences by DNA sequencing. The results showed that 5 of 14 sequenced phages displayed the cAPK recognition sequence motif (R)RXS/T. Their in vitro phosphorylation analyses revealed the specific labelled bands corresponding to the positive PKS phages with and without the展开更多
A method for simultaneous determination of nine cations including Fe 3+, Cu 2+, Ni 2+, Zn 2+, Co 2+, Fe 2+, Cd 2+, Mg 2+ and Ca 2+ by single-column ion chromatography with a conductivity detector was developed. The op...A method for simultaneous determination of nine cations including Fe 3+, Cu 2+, Ni 2+, Zn 2+, Co 2+, Fe 2+, Cd 2+, Mg 2+ and Ca 2+ by single-column ion chromatography with a conductivity detector was developed. The optimum composition of eluent was 6 mmol/L malic acid and 3 mmol/L ethylenediamine(pH=4 0). The effects of malic acid concentration, ethylenediamine concentration and pH value on retention time were studied in details. The method was used to determine Fe, Cu, Zn, Mg and Ca in whole blood and serum with satisfactory results.展开更多
文摘The application of non-suppressed ion chromatography for monitoring of trace elements in air particulate matter was studied in the present investigation. The results indicate that the use of microwave acid digestion method is superior in comparison with the conventional thermal acid digestion method as it leads to higher recovery, better reproducibility, lower volatility loss, better protection against environmental contamination and much less digestion time (5 minutes vs. 24 hours). The use of eluent as extractant is shown to reduce the water dip problem in the chro-matogram. The addition of chelating agent in the eluent coupled with UV detection is shown to provide satisfactory chromatographic separation and good sensitivity for the analysis of transition metals present in the air particulate matter. Using the U.S. National Bureau of Standards Reference Material 1648 Urban Particulate Matter as standard for checking, the analytical procedure is shown to give good recovery and reproducibility for the detection of the following cations and anions in air particulate matter: Fe2 Cu, Mn, Pb, Zn, Mg, Na, HN4+, Cl-, NO3- and SO42-. Field test was also performed to check the applicability of the method and the results obtained were discussed in the present paper.
文摘A method has been established to study the competing binding of metal ions with protein by a combined technique of microdialysis with high performance liquid chromatography (HPLC). Ni2+, Cd2+, Zn2+, Cu2+ and human serum albumin (HSA) were chosen as model metal ions and protein. The experimental results show that Ni2+ and Cu2+ share a common primary binding site on HSA, and Zn2+ and Cd2+ share a different common primary binding site from them, but there is a common multi-metal binding site for all of those four metal ions. This method show advantages of fast sampling, easily to be operated and especially to be useful when ideal spectroscopic probes are not available for the study of interaction between protein and metal ions.
文摘Protein kinase substrate phage (PKS phage) was constructed by fusing the substrate recognition consensus sequence of cAMP-dependent protein kinase (cAPK) with bacteriophage minor coat protein g3p and by dis-playing it on the surface of filamentous bacteriophage fd. Phosphorylation in vitro by cAPK showed a unique labelled band of approximately 60 ku, which was consistent with the molecular weight of the PKS-g3p fusion protein. Some weakly phosphorylated bands for both PKS phage and wild-type phage were also observed. Phage display random 15-mer peptide library phosphorylated by cAPK was selected with ferric (Fe3+ ) chelalion affinity resin. After 4 rounds of screening, phage clones were picked out to determine the displayed peptide sequences by DNA sequencing. The results showed that 5 of 14 sequenced phages displayed the cAPK recognition sequence motif (R)RXS/T. Their in vitro phosphorylation analyses revealed the specific labelled bands corresponding to the positive PKS phages with and without the
文摘A method for simultaneous determination of nine cations including Fe 3+, Cu 2+, Ni 2+, Zn 2+, Co 2+, Fe 2+, Cd 2+, Mg 2+ and Ca 2+ by single-column ion chromatography with a conductivity detector was developed. The optimum composition of eluent was 6 mmol/L malic acid and 3 mmol/L ethylenediamine(pH=4 0). The effects of malic acid concentration, ethylenediamine concentration and pH value on retention time were studied in details. The method was used to determine Fe, Cu, Zn, Mg and Ca in whole blood and serum with satisfactory results.