This paper reports that Goos-Hǎnchen (GH) shifts occurring on a symmetrical metal-cladding waveguide are experimentally identified. It was found that there exists a critical thickness of the upper metal layer, hcr,...This paper reports that Goos-Hǎnchen (GH) shifts occurring on a symmetrical metal-cladding waveguide are experimentally identified. It was found that there exists a critical thickness of the upper metal layer, hcr, above which negative shift is observed and, reversely, positive shift occurs. Both positive and negative GH shifts near the critical thickness do not vary dramatically and can achieve a maximum on the submillimeter scale, which is different from simulated results using the stationary-phase method. It also shows that this critical thickness, hcr, can be obtained at the position for zero reflectivity by setting the intrinsic damping to be the same as the radiative damping. The GH effects observed near the critical thickness are produced by extreme distortion of the reflected beam profiles, which limits the amplitude of the GH shift and, further, the sensitivity of the GH optical sensor based on the symmetrical metal-cladding waveguide.展开更多
An optical platform for sensitive detection of chemical vapor based on a polymer-coated symmetrical metal-cladding waveguide is proposed.The diffusion of chemical vapor usually leads to a combinational effect in the p...An optical platform for sensitive detection of chemical vapor based on a polymer-coated symmetrical metal-cladding waveguide is proposed.The diffusion of chemical vapor usually leads to a combinational effect in the polymer layer,i.e.,swelling and refractive index change.Owing to the high sensitivity of ultrahigh-order modes,the vapor-induced effect will give rise to a dramatic variation of the reflected light intensity.For proof-of-concept,a good linearity and a low detection limit of toluene and benzene are experimentally demonstrated with an amorphous Teflon AF polymer layer.展开更多
A metal-clad planar polymer waveguide refractive index sensor based on epoxy(EPO)polymer materials by using light intensity interrogation at 850 nm is designed.The polymethyl methacrylate(PMMA)material is deployed as ...A metal-clad planar polymer waveguide refractive index sensor based on epoxy(EPO)polymer materials by using light intensity interrogation at 850 nm is designed.The polymethyl methacrylate(PMMA)material is deployed as the low refractive index(RI)buffer layer in order to better couple the optical guided mode and the surface plasmon polaritons(SPP)mode for working in water environment.The effects of the gold film thickness,PMMA buffer layer thickness,waveguide layer thickness,waveguide width,and gold length on the sensor sensing characteristics have been comprehensively studied.Simulation results demonstrate that the normalized transmission increases quasi-linearly with the increment of RI of the analyte from 1.33 to 1.46.The sensitivity is 491.5 dB/RIU,corresponding to a high RI resolution of 2.6×10^(9)RIU.The designed SPP-based optical waveguide sensor is low-cost,wide-range,and high-precision,and has a broad application prospect in biochemical sensing with merits of miniaturization,flexibility,and multiplexing.展开更多
基金Project supported by the Research Fund for Selecting and Training Excellent Young Teachers in Universities of Shanghai, Shanghai Municipal Education Commission (Grant No slg08006)"Chen Guang" project of Shanghai Municipal Education Commission and Shanghai Education Development Foundation (Grant No 09CG49)+2 种基金Dawn Project of Education Committee of Shanghai and Shanghai Education Development Foundation (Grant No 08SG48)Innovation Program of Shanghai Municipal Education Commission (Grant No 09YZ221)the Program from Shanghai Committee of Science and Technology, China (Grant Nos 07DZ22026 and 08ZR1415400)
文摘This paper reports that Goos-Hǎnchen (GH) shifts occurring on a symmetrical metal-cladding waveguide are experimentally identified. It was found that there exists a critical thickness of the upper metal layer, hcr, above which negative shift is observed and, reversely, positive shift occurs. Both positive and negative GH shifts near the critical thickness do not vary dramatically and can achieve a maximum on the submillimeter scale, which is different from simulated results using the stationary-phase method. It also shows that this critical thickness, hcr, can be obtained at the position for zero reflectivity by setting the intrinsic damping to be the same as the radiative damping. The GH effects observed near the critical thickness are produced by extreme distortion of the reflected beam profiles, which limits the amplitude of the GH shift and, further, the sensitivity of the GH optical sensor based on the symmetrical metal-cladding waveguide.
基金supported by the National Natural Science Foundation of China (Grant No. 61168002)the Opening Foundation of the State Key Laboratory of Advanced Optical Communication Systems and Networks(Grant No. 2011GZKF031105)
文摘An optical platform for sensitive detection of chemical vapor based on a polymer-coated symmetrical metal-cladding waveguide is proposed.The diffusion of chemical vapor usually leads to a combinational effect in the polymer layer,i.e.,swelling and refractive index change.Owing to the high sensitivity of ultrahigh-order modes,the vapor-induced effect will give rise to a dramatic variation of the reflected light intensity.For proof-of-concept,a good linearity and a low detection limit of toluene and benzene are experimentally demonstrated with an amorphous Teflon AF polymer layer.
基金The authors gratefully acknowledge the financial support from the Shandong Provincial Key Research and Development Program(Grant Nos.2018YFJH0702 and 2019JZZY020711)Shandong Postdoctoral Innovation Project,and Qingdao Postdoctoral Applied Research Project.
文摘A metal-clad planar polymer waveguide refractive index sensor based on epoxy(EPO)polymer materials by using light intensity interrogation at 850 nm is designed.The polymethyl methacrylate(PMMA)material is deployed as the low refractive index(RI)buffer layer in order to better couple the optical guided mode and the surface plasmon polaritons(SPP)mode for working in water environment.The effects of the gold film thickness,PMMA buffer layer thickness,waveguide layer thickness,waveguide width,and gold length on the sensor sensing characteristics have been comprehensively studied.Simulation results demonstrate that the normalized transmission increases quasi-linearly with the increment of RI of the analyte from 1.33 to 1.46.The sensitivity is 491.5 dB/RIU,corresponding to a high RI resolution of 2.6×10^(9)RIU.The designed SPP-based optical waveguide sensor is low-cost,wide-range,and high-precision,and has a broad application prospect in biochemical sensing with merits of miniaturization,flexibility,and multiplexing.