期刊文献+
共找到17篇文章
< 1 >
每页显示 20 50 100
L-shell x-ray fluorescence relative intensities for elements with 62≤Z≤83 at 18 keV and 23 keV by synchrotron radiation
1
作者 M Alqadi S AL-Humaidi +1 位作者 H Alkhateeb F Alzoubi 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第8期270-273,共4页
The relative intensities of L-subshell x-ray fluorescence(XRF)for elements with atomic numbers 62≤Z≤83 were measured at two excitation energies,18 keV and 23 keV,using a synchrotron radiation source at a beamline of... The relative intensities of L-subshell x-ray fluorescence(XRF)for elements with atomic numbers 62≤Z≤83 were measured at two excitation energies,18 keV and 23 keV,using a synchrotron radiation source at a beamline of the Synchrotron Light Center for Experimental Science and Applications in the Middle East(SESAME),Jordan.The experimentally measured results of the relative intensities were compared with the calculated results using the subshell fluorescence yield and the Coster-Kronig transition probabilities recommended by Campbell and the values based on the Dirac-Hartree-Slater model by Puri.The experimental and theoretical results are in agreement.In this work,L XRF relative intensities for the elements Sm,Gd,Tb,Er,Ta,W,Re,Hg,Pb and Bi at energies of 18 keV and 23 keV were measured. 展开更多
关键词 L shell x-ray fluorescence(XRF) relative intensities synchrotron radiation
下载PDF
Analysis of nickel distribution by synchrotron radiation X-ray fluorescence in nickel-induced early- and late-phase allergic contact dermatitis in Hartley guinea pigs 被引量:1
2
作者 Shan-Qun Jiang Xiang-Yu Wu +11 位作者 Jin-Lyu Sun Guang Chen Rui Tang Zhi Li Ruo-Yao Wei Lan Liang Xian-Jie Zhou Dong-Liang Chen Jun Li Hong Gao Jing Zhang Zuo-Tao Zhao 《Chinese Medical Journal》 SCIE CAS CSCD 2019年第16期1959-1964,共6页
Background: Nickel-induced allergic contact dermatitis (Ni-ACD) is a global health problem. More detailed knowledge on the skin uptake of haptens is required. This study aimed to investigate the penetration process an... Background: Nickel-induced allergic contact dermatitis (Ni-ACD) is a global health problem. More detailed knowledge on the skin uptake of haptens is required. This study aimed to investigate the penetration process and distribution of nickel in skin tissues with late phase and early phase of Ni-ACD to understand the mechanisms of metal allergy. Methods: Forty Hartley guinea pigs were divided into four groups according to the NiSO4 sensitizing concentration and the NiSO4 challenged concentration: the 5% NiSO4-group, 5% to 10%(sensitization-challenge;late phase group);10% NiSO4-group, 10% to 10%(sensitization-challenge;early-phase group);and the positive and negative controls. Pathological biopsies were performed on each group. The depth profile of nickel element concentration in the skin of guinea pigs was detected by synchrotron radiation micro X-ray fluorescence spectroscopy (SR-μ-XRF) and micro X-ray absorption near-edge spectroscopy (μ-XANES). Results: In each section, the nickel element concentration in both the 5% NiSO4-group and 10% NiSO4-group was significantly higher than that in the negative control group. In the upper 300-μm section of skin for the early phase group, the nickel element concentration was significantly higher than that in the lower section of skin. In deeper sections (>200 μm) of skin, the concentration of nickel in the early phase group was approximately equal to that in the late phase group. The curve of the late phase group was flat, which means that the nickel element concentration was distributed uniformly by SR-μ-XRF. According to the XANES data for the 10% NiSO4 metal salt solution, structural changes occurred in the skin model sample, indicating that nickel was not present in the Ni^2+ aqueous ionic state but in the nickel-binding protein. Conclusions: This study showed that the distribution of the nickel element concentration in ACD skin tissue was different between the early phase and late phase groups. The nickel element was not present in the Ni^2+ aqueous ionic state but bound with certain proteins to form a complex in the stratum corneum in ACD model tissue. 展开更多
关键词 synchrotron radiation micro x-ray fluorescence SPECTROSCOPY Micro x-ray absorption near-edge SPECTROSCOPY Dermatitis ALLERGIC CONTACT Nickel-induced ALLERGIC CONTACT DERMATITIS Dermatology
原文传递
In situ analysis of trace elements in metalloproteins of human liver by synchrotron radiation X-ray fluorescence
3
作者 陈春英 章佩群 +2 位作者 柴之芳 李光城 黄宇营 《Science China Mathematics》 SCIE 2000年第1期88-92,共5页
A method using synchrotron radiation X-ray fluorescence analysis to in situ determine trace elements during protein electrophoretically separating process was established. The distribution of elements in protein bands... A method using synchrotron radiation X-ray fluorescence analysis to in situ determine trace elements during protein electrophoretically separating process was established. The distribution of elements in protein bands for human liver cytosolic sample separated by SDS-PAGE was analyzed a-long polyacrylamide gel. The results showed that the protein fraction of peak III in cvtosol was mainly composed of metal ion Zn-associated proteins, being in agreement with that given by atomic absorption spectrometry. Thus, it demonstrated the feasibility of this novel technique for in situ analysis of trace elements in protein bands. 展开更多
关键词 synchrotron radiation x-ray fluorescence ANALYSIS in SITU ANALYSIS METALLOPROTEIN electrophoretic separation.
原文传递
Characterization of metal element distributions in the rat brain following ischemic stroke by synchrotron radiation microfluorescence analysis 被引量:3
4
作者 Shu-Peng Shi Hui Wang +3 位作者 Zhuo-Hui Chen Xiao-Han Li Shi-Xin Liu Meng-Qi Zhang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第10期1-12,共12页
Ischemic stroke is one of the leading causes of death worldwide,and effective treatment strategies in the chronic phase of this disease remain insufficient.Homeostasis of metals in the brain plays an important role in... Ischemic stroke is one of the leading causes of death worldwide,and effective treatment strategies in the chronic phase of this disease remain insufficient.Homeostasis of metals in the brain plays an important role in maintaining normal brain function.However,the dynamic spatial distributions of iron,zinc,calcium,potassium,and copper in a rat brain following ischemic stroke and the association between structural distribution and function remain to be elucidated.In this study,we used a synchrotron radiation-based micro-X-ray fluorescence technique to image element mapping changes in special rat brain regions after ischemic stroke,showing the distribution characteristics of iron,zinc,calcium,potassium,and copper.We demonstrated,for the first time,the consistent dynamic spatial distributions of metal elements at a series of time points(3 h,4.5 h,6 h,12 h,1 d,3 d,5 d,7 d,10 d,14 d,28 d)after brain ischemia,which revealed that the homeostasis of iron,zinc,calcium,potassium,and copper in the brain was disturbed with distinctive change trends,providing clear insights in understanding the underlying pathogenesis of stroke from a novel perspective,thus laying the foundation of further developing new drug targets for stroke treatment. 展开更多
关键词 Ischemic stroke synchrotron radiation x-ray fluorescence METAL Rat brain
下载PDF
The Study Internal Structure of the Annual Layers in Lake Sediments Using Synchrotron Radiation with X-ray Focusing Optics
5
作者 Fedor DARIN Ivan KALUGIN +1 位作者 Andrey DARIN Yakov RAKSHUN 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2014年第S1期5-6,共2页
1 Introduction Annually laminated(varve)sedimentary deposits are considered as one of the most important archives,since they offer precise temporal information(years)in combination with high time resolutions.Bottom se... 1 Introduction Annually laminated(varve)sedimentary deposits are considered as one of the most important archives,since they offer precise temporal information(years)in combination with high time resolutions.Bottom sediments of the lakes contain detailed geochemical information on 展开更多
关键词 VARVE .synchrotron radiation scanning X_ray fluorescence microanalysis focusing x-ray optics.
下载PDF
Scan system for arbitrary-shaped samples at the synchrotron radiation facility
6
作者 Xu-Ying Lan Dong-Xu Liang Cheng-Wen Mao 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第5期18-27,共10页
X-ray fluorescence(XRF) scan methodology is important for elemental mapping of samples at a synchrotron radiation facility. To save the experiment time and improve the experiment efficiency, one should develop an effi... X-ray fluorescence(XRF) scan methodology is important for elemental mapping of samples at a synchrotron radiation facility. To save the experiment time and improve the experiment efficiency, one should develop an efficient XRF scan method. In this paper, a new scan mode is presented. It can map arbitrary-shaped areas withou stopping the motors. The control and data acquisition system integrates motor controlling, detector triggering, and data acquisition and storage. The system realizes the arbitrary-shaped 2D-mapping and fluorescence data acquisition synchronously. SR-XRF mapping has been performed with a standard gold mask to verify the validity of this method a beamline BL15U1 of the Shanghai Synchrotron Radiation Facility. The results show that this method reduces the tota scan time and improves the experiment efficiency. 展开更多
关键词 synchrotron radiation x-ray fluorescence mapping EPICS XPS controller
下载PDF
Influence of crystal materials on the synchrotron X-ray fluorescence analysis:a study of crystal and amorphous clinopyroxene
7
作者 Haifei Zheng Yuying Huang +1 位作者 Peixue Ma Xing Ju 《Chinese Science Bulletin》 SCIE EI CAS 1999年第12期1144-1146,共3页
Synchrotron X-ray fluorescence analyses of crystal and amorphous clinopyroxene were compared. The results showed that using the synchrotron X-ray as a source of energy, the diffraction X-ray of crystal materials will ... Synchrotron X-ray fluorescence analyses of crystal and amorphous clinopyroxene were compared. The results showed that using the synchrotron X-ray as a source of energy, the diffraction X-ray of crystal materials will seriously affect the X-ray fluorescence analysis. In order to avoid the influence of diffraction, the best way to solve it is to use the monochromatic source, or to have a collimating slit between sample and Si(Li) detector. 展开更多
关键词 synchrotron radiation x-ray fluorescence analysis diffraction.
原文传递
Synchrotron radiation XRF microprobe investigation of elemental distribution in femoral head slice with osteoporosis 被引量:3
8
作者 ZHANG Yuanxun CHENG Feng +7 位作者 LI Deyi WANG Yinsong ZHANG Guilin XU Hongjie LIAO Wensheng TANG Tingling HUANG Yuying HE Wei 《Chinese Science Bulletin》 SCIE EI CAS 2001年第13期1138-1141,共4页
This note deals with the scanning of femoral head slices from both normal and osteoporosis subjects using synchrotron radiation X-ray fluorescence (SRXRF) microprobe technique. The sample preparation and experimental ... This note deals with the scanning of femoral head slices from both normal and osteoporosis subjects using synchrotron radiation X-ray fluorescence (SRXRF) microprobe technique. The sample preparation and experimental apparatus are described in detail. The quantitative computerized tomography (QCT) of elemental distribution, such as Ca, P, K, Fe, Zn, Sr and Pb in bone slice tissue including cartilage, substantial compact and substantial spongy, is investigated. Combined with the correlation between P, K, Zn, Sr and Ca, the loss way of minerals and the physiological functions of some metal elements in bone are also discussed. 展开更多
关键词 synchrotron radiation x-ray fluorescence MICROPROBE inorganic elements osteoporosis.
原文传递
First X-ray fluorescence CT experimental results at the SSRF X-ray imaging beamline 被引量:5
9
作者 邓彪 杨群 +2 位作者 谢红兰 杜国浩 肖体乔 《Chinese Physics C》 SCIE CAS CSCD 2011年第4期402-404,共3页
X-ray fluorescence CT is a non-destructive technique for detecting elemental composition and distribution inside a specimen. In this paper, the first experimental results of X-ray fluorescence CT obtained at the SSRF ... X-ray fluorescence CT is a non-destructive technique for detecting elemental composition and distribution inside a specimen. In this paper, the first experimental results of X-ray fluorescence CT obtained at the SSRF X-ray imaging beamline (BL13W1) are described. The test samples were investigated and the 2D elemental image was reconstructed using a filtered back-projection algorithm. In the sample the element Cd was observed. Up to now, the X-ray fluorescence CT could be carried out at the SSRF X-ray imaging beamline. 展开更多
关键词 x-ray fluorescence CT elemental distribution synchrotron radiation
原文传递
Sulfur speciation and bioaccumulation in camphor tree leaves as atmospheric sulfur indicator analyzed by synchrotron radiation XRF and XANES 被引量:9
10
作者 Jianrong Zeng Guilin Zhang +5 位作者 Liangman Bao Shilei Long Mingguang Tan Yan Li Chenyan Ma Yidong Zhao 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2013年第3期605-612,共8页
Analyzing and understanding the effects of ambient pollution on plants is getting more and more attention as a topic of environmental biology.A method based on synchrotron radiation X-ray fluorescence and X-ray absorp... Analyzing and understanding the effects of ambient pollution on plants is getting more and more attention as a topic of environmental biology.A method based on synchrotron radiation X-ray fluorescence and X-ray absorption near edge structure spectroscopy was established to analyze the sulfur concentration and speciation in mature camphor tree leaves (CTLs),which were sampled from 5 local fields in Shanghai,China.Annual SO2 concentration,SO42-concentration in atmospheric particulate,SO42-and sulfur concentration in soil were also analyzed to explore the relationship between ambient sulfur sources and the sulfur nutrient cycling in CTLs.Total sulfur concentration in mature camphor tree leaves was 766-1704 mg/kg.The mainly detected sulfur states and their corresponding compounds were +6 (sulfate,include inorganic sulfate and organic sulfate),+5.2 (sulfonate),+2.2 (suloxides),+0.6 (thiols and thiothers),+0.2 (organic sulfides).Total sulfur concentration was strongly correlated with sulfate proportion with a linear correlation coefficient up to 0.977,which suggested that sulfur accumulated in CTLs as sulfate form.Reduced sulfur compounds (organic sulfides,thiols,thioethers,sulfoxide and sulfonate) assimilation was sufficed to meet the nutrient requirement for growth at a balanced level around 526 mg/kg.The sulfate accumulation mainly caused by atmospheric sulfur pollution such as SO2 and airborne sulfate particulate instead of soil contamination.From urban to suburb place,sulfate in mature CTLs decreased as the atmospheric sulfur pollution reduced,but a dramatic increase presented near the seashore,where the marine sulfate emission and maritime activity pollution were significant.The sulfur concentration and speciation in mature CTLs effectively represented the long-term biological accumulation of atmospheric sulfur pollution in local environment. 展开更多
关键词 synchrotron radiation x-ray fluorescence x-ray absorption near edge structure sulfur speciation sulfur bioaccumulation camphor tree leaves
原文传递
用同步辐射X荧光分析法研究兔肝金属硫蛋白中的微量元素 被引量:3
11
作者 陈春英 章佩群 +2 位作者 高愈希 柴之芳 黄宇营 《核技术》 CAS CSCD 北大核心 2003年第1期17-20,共4页
采用同步辐射X荧光分析法 (SRXRF)直接测定了兔肝金属硫蛋白 (MT)中的金属离子含量 ,以及经过十二烷基硫酸钠 -聚丙烯酰胺凝胶电泳 (SDS -PAGE)分离后凝胶板中蛋白条带上金属离子的分布。实验结果表明 ,兔肝MT - 1以含锌为主 ,占总金属... 采用同步辐射X荧光分析法 (SRXRF)直接测定了兔肝金属硫蛋白 (MT)中的金属离子含量 ,以及经过十二烷基硫酸钠 -聚丙烯酰胺凝胶电泳 (SDS -PAGE)分离后凝胶板中蛋白条带上金属离子的分布。实验结果表明 ,兔肝MT - 1以含锌为主 ,占总金属含量的 97.9% ;兔肝MT - 2以含锌、镉为主。本工作表明 。 展开更多
关键词 微量元素 金属硫蛋白 同步辐射X荧光分析 电泳 SRXRF 柱层析法 分离 纯化
下载PDF
用同步辐射X-荧光定量测定电泳分离后蛋白条带内的微量元素 被引量:4
12
作者 董元兴 高愈希 +6 位作者 陈春英 李柏 邢丽 喻宏伟 何伟 黄宇营 柴之芳 《分析化学》 SCIE EI CAS CSCD 北大核心 2006年第4期443-446,共4页
建立了同步辐射X-荧光(SRXRF)定量测定生物样品等电聚焦(IEF)分离后蛋白条带内的微量元素Fe、Cu和Zn的方法.用薄层聚丙烯酰胺凝胶分离人血红蛋白后,用SRXRF测定了各亚型条带内的金属含量,用加一定量金属的含蛋白聚丙烯酰胺凝胶做SR... 建立了同步辐射X-荧光(SRXRF)定量测定生物样品等电聚焦(IEF)分离后蛋白条带内的微量元素Fe、Cu和Zn的方法.用薄层聚丙烯酰胺凝胶分离人血红蛋白后,用SRXRF测定了各亚型条带内的金属含量,用加一定量金属的含蛋白聚丙烯酰胺凝胶做SRXRF定量测定蛋白条带内微量元素Fe、Cu和Zn的定量标准,校准曲线线性回归系数r在0~8 μg/g范围内均大于0.99;检出限分别为2.43、1.12和0.96 μg/g;测定蛋白条带内Fe和Zn的回收率分别为90.4%和115.7 %.该联用技术可用于生物样品中微量元素的化学形态分析,同时给出蛋白质的微量元素组成和等电点等信息. 展开更多
关键词 微量元素 形态分析 同步辐射X荧光 电泳 金属蛋白
下载PDF
Compositional Distribution and Growth Mode of Garnet Porphyroblasts during Deformation and Metamorphism 被引量:1
13
作者 ZHAOGuiping LIUShuwen LIUXiaohan 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2004年第1期186-190,共5页
Although porphyroblast microstructures play an important role in structural and metamorphic studies, there are still controversies in the interpretation. The focus is how porphyroblasts grow during deformation and met... Although porphyroblast microstructures play an important role in structural and metamorphic studies, there are still controversies in the interpretation. The focus is how porphyroblasts grow during deformation and metamorphism. In this paper, we introduce a new approach, the Synchrotron Radiation X-Ray Fluorescence, to a hemi-quantitative interpretation of the growth mode of porphyroblasts. The analysis was done at the Beijing Synchrotron Radiation Facility. The specimens were sampled from metapelite of the Baoyintu Group, northern Urad Middle Banner, Inner Mongolia. The new method is successful for determining the microscopic distribution of trace elements in porphybroblasts. The results support the theory of deformation partition, which has been brought forth by Bell and his colleagues, and demonstrate the existence of porphyroblast growth phases and the growth mode of porphyroblasts by hemi-quantitative mineral chemical analysis. The porphyroblast grows stage by stage in the manner of the distribution of a roseleaf and is controlled by deformation. We call the growth stage of porphyroblast a growth phase. 展开更多
关键词 synchrotron radiation x-ray fluorescence Analysis deformation partition PORPHYROBLAST growth phase Baoyintu Group
下载PDF
SRXRF Experiments and Analytical Methods of Mineral Individual Fluid Inclusions
14
作者 Wu Chunxue Huang Yuying +3 位作者 Li Hongkui Chen Chuanren He Wei Li Kuifa 《Petroleum Science》 SCIE CAS CSCD 2007年第3期63-67,共5页
This paper focuses on the micro-beam and trace element non-destructive experiment and analytical method of mineral fluid inclusions by synchrotron radiation X-ray fluorescence (SRXRF) microprobe at Beijing Synchrotr... This paper focuses on the micro-beam and trace element non-destructive experiment and analytical method of mineral fluid inclusions by synchrotron radiation X-ray fluorescence (SRXRF) microprobe at Beijing Synchrotron Radiation Facility (BSRF). The experimental instrument, measurement process and calculating method are introduced. A set of oil- and gas-containing typical mineral fluid inclusions taken from the Tazhong and Lunnan oilfields in the Tarim Basin were analyzed non-destructively. The trace element contents in the fluid inclusions may provide guidance for oil and gas exploration and development. 展开更多
关键词 synchrotron radiation x-ray fluorescence (SRXRF) mineral fluid inclusion experiment and analysis
下载PDF
Sodium and potassium in the bones of penguin and skua revealed by EPR and SR-XRF technique
15
作者 谢周清 徐思琦 +3 位作者 黄宇营 何伟 金嗣昭 孙立广 《Chinese Journal of Polar Science》 2010年第1期22-30,共9页
Penguin and skua in the maritime Antarctic have high salt loadings in the body due to almost exclusive diet consumption of marine invertebrates.However,the storage and turnover of sodium and potassium in these animals... Penguin and skua in the maritime Antarctic have high salt loadings in the body due to almost exclusive diet consumption of marine invertebrates.However,the storage and turnover of sodium and potassium in these animals are poorly investigated.Here we determined the concentration and microscopic distribution of the two elements in the bones of penguin and skua.The average concentrations of sodium and potassium in penguin bone were comparable with that in skua bone(0.18% and 0.82% for penguin bone;0.19% and 0.76% for skua bone in dry weight).The ratios of sodium to calcium and potassium to calcium(0.0330 and 0.0075 for penguin,0.0335 and 0.0082 for skua in average by weight) were somewhat higher than the reported ratios for terrestrial animals,indicating these marine animals' bone enrichment of salt.The ratios of sodium to potassium in average by weight were 6.75 and 4.65 for penguin and skua,respectively.This value is much lower compared with the bulk sea water ratio of about 27.0,implying that potassium is favorable to reside in the bone rather than sodium.Both sodium and potassium were found to significant correlation with the content of organic materials in bone based upon the intensity of native signal determined by electron paramagnetic resonance(EPR).It was estimated that almost all of potassium is kept within the organic phases,while about 30% of sodium is stored in organic phases and the other 70% within mineral phase.The microscopic distributions of potassium in the cross-section and/or surface were revealed by synchrotron radiation Xray fluorescence(SR-XRF) technique.The ratio of potassium to calcium based upon the SR-XRF intensity counter varied considerably from the surface to the interior,and on the surface the highest concentration of potassium was observed in the middle section with decreasing amounts toward the edge.This indirectly documented that exchange of potassium between fluid and bone organic phase maybe occur. 展开更多
关键词 bone penguin and skua sodium and potassium electron paramagnetic resonance(EPR) synchrotron radiation x-ray fluorescence(SR-XRF).
下载PDF
Compositional change in human enamel irradiated with MIR free electron laser
16
作者 LIU Nianqing LI Yonggui +8 位作者 ZHU Junbiao ZHANG Liwen WANG Mingkai WU Gang YANG Xueping Li Guangcheng Huang Yuying DONG Yanmei GAO Xuejun 《Chinese Science Bulletin》 SCIE EI CAS 2001年第23期2016-2018,共3页
The purpose of this study was to investigate compositional changes in human enamel irradiated with the free electron laser (FEL). The exposure on dental enamel at the wavelength of 9.64 μm was observed with the Beiji... The purpose of this study was to investigate compositional changes in human enamel irradiated with the free electron laser (FEL). The exposure on dental enamel at the wavelength of 9.64 μm was observed with the Beijing free electron laser. The distribution of elements in the irradiated or non-irradiated enamel was measured by scanning electron microscope (SEM) with energy-dispersive spectroscopy and synchrotron radiation X-ray fluorescence (SRXRF) in Beijing Synchrotron Radiation Facility (BSRF). The results showed that the P/Ca ratio in the ablation region of enamel at the maximum wavelength of infrared absorption was obviously smaller than that at the non-maximum wavelength. In the ablation region the ratios of P/Ca and Ca/Sr were smaller than those in the non-ablation region. The distributions of P, Ca and Sr in the ablation region were heterogeneous due to the element change caused by FEL irradiation. 展开更多
关键词 human ENAMEL BEIJING free electron laser synchrotron radiation x-ray fluorescence ablation ELEMENT distribution.
原文传递
Ore Forming Fluids of Several Gold Deposits in the Irtysh Gold Belt, Xinjiang, China
17
作者 Yingwei Wang Jiuhua Xu +3 位作者 Rufu Ding Hui Zhang Xihui Cheng Chunjing Bian 《Journal of Earth Science》 SCIE CAS CSCD 2020年第2期298-312,共15页
The metallogenic environment of the Irtysh gold belt in Xinjiang is studied in detail.The metallogenic geological background,metallogenic conditions and ore-controlling factors of the gold deposits in eastern,central ... The metallogenic environment of the Irtysh gold belt in Xinjiang is studied in detail.The metallogenic geological background,metallogenic conditions and ore-controlling factors of the gold deposits in eastern,central and western regions of the metallogenic belt are compared.The metallogenic structure of the Irtysh tectonic belt has the characteristics of diverging to the west and converging to the east.Composite ore controlling by ductile shearing and magmatic activity in Irtysh gold belt result in zoned and segmented distribution of gold mineralization.Through the fluid inclusion research and H-O-S isotope analysis,the evolution regularity of gold ore-forming fluids in the region was analyzed.Synchrotron radiation X-ray fluorescence was used to analysis the concentration of metal elements in a single fluid inclusion,explaining the occurrence and migration process of Au in hydrothermal fluid.The source of ore forming minerals in western gold deposit is more closely related to magmatic activity,and the structural metamorphism of eastern gold deposit has greater influence on mineralization.Metallogenic fluids of gold deposits are characterized by metamorphic water(and magmatic water)in the early stage and mixed with meteoric water in the late stage.And the metallogenic elements are enriched in CO2 rich fluid.The Au is mainly activated,migrated and enriched with the mixed fluid of magmatic hydrothermal,metamorphic hydrothermal and atmospheric precipitation in the medium-low temperature,shallow to medium-deep environment. 展开更多
关键词 Irtysh gold belt ORE FORMING FLUIDS H-O-S isotope synchrotron radiation x-ray fluorescence METALLOGENIC model
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部