We develop two types of adaptive energy preserving algorithms based on the averaged vector field for the guiding center dynamics,which plays a key role in magnetized plasmas.The adaptive scheme is applied to the Gauss...We develop two types of adaptive energy preserving algorithms based on the averaged vector field for the guiding center dynamics,which plays a key role in magnetized plasmas.The adaptive scheme is applied to the Gauss Legendre’s quadrature rules and time stepsize respectively to overcome the energy drift problem in traditional energy-preserving algorithms.These new adaptive algorithms are second order,and their algebraic order is carefully studied.Numerical results show that the global energy errors are bounded to the machine precision over long time using these adaptive algorithms without massive extra computation cost.展开更多
The present work proposed a new method for the modeling by the finite element method of the acoustic propagation problems in infinite axisymmetric cylindrical guides lined with locally reacting absorbent materials wit...The present work proposed a new method for the modeling by the finite element method of the acoustic propagation problems in infinite axisymmetric cylindrical guides lined with locally reacting absorbent materials without flow. The method deals with the development of an efficient transparent boundary condition based on DtN operators. The method developed in this study is successfully applied to a straight axisymmetric lined guide by imposing a mode on one of the artificial boundaries of the truncated guide. The results are in good agreement with analytical solutions. Applying the method for a non-uniform axisymmetric lined guide which is a complex case, proved its effectiveness and the results compared to those of PML layers are in very good agreement.展开更多
OBJECTIVE: To compare the clinical effect of brachial plexus block with "One Injection Two Points" guided under ultrasound and the conventional method guiding by ultrasound. METHODS: 70 patients were randomi...OBJECTIVE: To compare the clinical effect of brachial plexus block with "One Injection Two Points" guided under ultrasound and the conventional method guiding by ultrasound. METHODS: 70 patients were randomized evenly into 2 groups, with 35 patients in each group, while the Experiment Group(Group B) received One Injection Two Points" method, the Control Group(Group A) received the conventional method.The nerve block every 5 s, the success rate of anesthesia, the dosage of local anesthetics, second remedial anesthesia, adverse reactions, etc.were recorded. RESULTS: Group B was superior to group A in the success rate of anesthesia; There were 6 patients in group A who required constant pump injection of Remifentanil to remedy, while no patients in Group B needed remedy treatment. There were no serious adverse reactions in both groups.CONCLUSIONS: The clinical effect of brachial plexus block with "One Injection Two Points" method guided under ultrasoundguiding by ultrasound was superior to that of the conventional method.展开更多
With the full-vector plane-wave method (FVPWM) and the full-vector beam propagation method (FVBPM), the dependences of the band-gap and mode characteristics on material index and cladding structure parameter in an...With the full-vector plane-wave method (FVPWM) and the full-vector beam propagation method (FVBPM), the dependences of the band-gap and mode characteristics on material index and cladding structure parameter in anti- resonance guiding photonic crystal fibres (ARGPCFs) are sufficiently analysed. An ARGPCF operating in the near- infrared wavelength is shown. The influences of the high index cylinders, glass interstitial apexes and silica structure on the characteristics of band-gaps and modes are deeply investigated. The equivalent planar waveguide theory is used for analysing such an ARGPCF filled by the isotropic materials, and the resonance and the anti-resonance characteristics r:~n h~ w~|] r^r~dlrtpd展开更多
The parallelism of saw guide motion locus against the blade is one of the main iterns in the testing of the geometric precision of the whole woodworking band saxving-machine. It reflects the making and mounting precis...The parallelism of saw guide motion locus against the blade is one of the main iterns in the testing of the geometric precision of the whole woodworking band saxving-machine. It reflects the making and mounting precisions of the sawguide device,having a direct effect on the working performance. the saw timber quality. and the safety (nature) of the woodworking band sawing-machine, so it is of great importance in the testing process of the band sawing-machine assembly and their going out of the plant.展开更多
To analyze the stress of the guiding & positioning board and the effectiveness of the guiding & positioning device,according to guiding & positioning device's operational principle and structure,the gu...To analyze the stress of the guiding & positioning board and the effectiveness of the guiding & positioning device,according to guiding & positioning device's operational principle and structure,the guiding & positioning board's motion regular was analyzed by diagrammatical method based on 2 postulated conditions.Considering about the working conditions' change,simulations in 5 different kinds of working conditions were done to check the correctness of the motion regulars obtained by diagrammatical method.Simulation results prove that the motion regulars are right,the postulated conditions have no effect on the obtained motion regulars.According to the simulation results,the motion processs's characters were drawn out at the same time.展开更多
AIM To evaluate the efficacy of endoscopic ultrasoundguided fine needle aspiration(EUS-FNA) of pancreatic head cancer when pushing(push method) or pulling the echoendoscope(pull method).METHODS Overall, 566 pancreatic...AIM To evaluate the efficacy of endoscopic ultrasoundguided fine needle aspiration(EUS-FNA) of pancreatic head cancer when pushing(push method) or pulling the echoendoscope(pull method).METHODS Overall, 566 pancreatic cancer patients had their first EUS-FNA between February 2001 and December 2017. Among them, 201 who underwent EUS-FNA for pancreatic head lesions were included in this study. EUS-FNA was performed by the push method in 85 patients, the pull method in 101 patients and both the push and pull methods in 15 patients. After propensity score matching(age, sex, tumor diameter, and FNA needle), 85 patients each were stratified into the push and pull groups. Patient characteristics and EUSFNA-related factors were compared between the two groups.RESULTS Patient characteristics were not significantly different between the two groups. The distance to lesion was significantly longer in the push group than in the pull group(13.9 ± 4.9 mm vs 7.0 ± 4.9 mm, P < 0.01). The push method was a significant factor influencing the distance to lesion(≥ median 10 mm)(P < 0.01). Additionally, tumor diameter ≥ 25 mm(OR = 1.91, 95%CI: 1.02-3.58, P = 0.043) and the push method(OR = 1.91, 95%CI: 1.03-3.55, P = 0.04) were significant factors contributing to the histological diagnosis of malignancy.CONCLUSION The pull method shortened the distance between the endoscope and the lesion and facilitated EUS-FNA of pancreatic head cancer. The push method contributed to the histological diagnosis of pancreatic head cancer using EUS-FNA specimens.展开更多
视差不连续区域和重复纹理区域的误匹配率高一直是影响双目立体匹配测量精度的主要问题,为此,本文提出一种基于多特征融合的立体匹配算法。首先,在代价计算阶段,通过高斯加权法赋予邻域像素点的权值,从而优化绝对差之和(Sum of Absolute...视差不连续区域和重复纹理区域的误匹配率高一直是影响双目立体匹配测量精度的主要问题,为此,本文提出一种基于多特征融合的立体匹配算法。首先,在代价计算阶段,通过高斯加权法赋予邻域像素点的权值,从而优化绝对差之和(Sum of Absolute Differences,SAD)算法的计算精度。接着,基于Census变换改进二进制链码方式,将邻域内像素的平均灰度值与梯度图像的灰度均值相融合,进而建立左右图像对应点的判断依据并优化其编码长度。然后,构建基于十字交叉法与改进的引导滤波器相融合的聚合方法,从而实现视差值再分配,以降低误匹配率。最后,通过赢家通吃(Winner Take All,WTA)算法获取初始视差,并采用左右一致性检测方法及亚像素法提高匹配精度,从而获取最终的视差结果。实验结果表明,在Middlebury数据集的测试中,所提SAD-Census算法的平均非遮挡区域和全部区域的误匹配率为分别为2.67%和5.69%,测量200~900 mm距离的平均误差小于2%;而实际三维测量的最大误差为1.5%。实验结果检验了所提算法的有效性和可靠性。展开更多
目的:观察超声引导下股神经阻滞联合复元活血汤对全膝关节置换术后患者疼痛程度及膝关节功能的影响。方法:选择2020年5月至2022年5月就诊于武汉市中医医院骨科收治的拟行全膝关节置换术的60例膝骨关节炎患者,按照随机数字表法分为试验...目的:观察超声引导下股神经阻滞联合复元活血汤对全膝关节置换术后患者疼痛程度及膝关节功能的影响。方法:选择2020年5月至2022年5月就诊于武汉市中医医院骨科收治的拟行全膝关节置换术的60例膝骨关节炎患者,按照随机数字表法分为试验组和对照组,每组各30例。两组患者均给予人工全膝关节置换术,对照组于术后即刻行超声引导下股神经阻滞镇痛,试验组在对照组治疗的基础上口服复原活血汤。记录两组患者手术后第3天、第5天、第7天静息及被动屈曲20°、50°、70°时视觉模拟评分法(visual analogue scale,VAS)评分、患膝关节周缘肿胀差值、关节主动屈伸活动度、美国特种外科医院膝关节功能(hospital for special surgery,HSS)评分。结果:静息0°状态下,术后第3天试验组VAS评分高于对照组(P<0.05),但术后第5天、第7天两组患者VAS评分比较,差异无统计学意义(P>0.05)。被动屈曲20°、45°、70°状态下,术后第3天、第5天、第7天试验组VAS评分高于对照组(P<0.05)。在同一测量点,术后第3天、第5天、第7天试验组患肢肿胀差值大对照组(P<0.05)。术后第3天、第5天、第7天试验组膝关节主动屈曲角度大于对照组(P<0.05)。术后第3天、第5天、第7天试验组膝关节HSS评分高于对照组(P<0.05)。结论:将超声引导下股神经阻滞联合复元活血汤运用于全膝关节置换术后,可降低术后各时间段的静息及主动屈伸时的疼痛程度,缓解患肢肿胀程度,从而增加患膝活动范围,促进膝关节功能恢复。展开更多
基金supported by National Natural Science Foundation of China(Nos.11901564,11775222 and 12171466)Geo-Algorithmic Plasma Simulator(GAPS)Project。
文摘We develop two types of adaptive energy preserving algorithms based on the averaged vector field for the guiding center dynamics,which plays a key role in magnetized plasmas.The adaptive scheme is applied to the Gauss Legendre’s quadrature rules and time stepsize respectively to overcome the energy drift problem in traditional energy-preserving algorithms.These new adaptive algorithms are second order,and their algebraic order is carefully studied.Numerical results show that the global energy errors are bounded to the machine precision over long time using these adaptive algorithms without massive extra computation cost.
文摘The present work proposed a new method for the modeling by the finite element method of the acoustic propagation problems in infinite axisymmetric cylindrical guides lined with locally reacting absorbent materials without flow. The method deals with the development of an efficient transparent boundary condition based on DtN operators. The method developed in this study is successfully applied to a straight axisymmetric lined guide by imposing a mode on one of the artificial boundaries of the truncated guide. The results are in good agreement with analytical solutions. Applying the method for a non-uniform axisymmetric lined guide which is a complex case, proved its effectiveness and the results compared to those of PML layers are in very good agreement.
文摘OBJECTIVE: To compare the clinical effect of brachial plexus block with "One Injection Two Points" guided under ultrasound and the conventional method guiding by ultrasound. METHODS: 70 patients were randomized evenly into 2 groups, with 35 patients in each group, while the Experiment Group(Group B) received One Injection Two Points" method, the Control Group(Group A) received the conventional method.The nerve block every 5 s, the success rate of anesthesia, the dosage of local anesthetics, second remedial anesthesia, adverse reactions, etc.were recorded. RESULTS: Group B was superior to group A in the success rate of anesthesia; There were 6 patients in group A who required constant pump injection of Remifentanil to remedy, while no patients in Group B needed remedy treatment. There were no serious adverse reactions in both groups.CONCLUSIONS: The clinical effect of brachial plexus block with "One Injection Two Points" method guided under ultrasoundguiding by ultrasound was superior to that of the conventional method.
基金partly supported by the National Key Basic Research Special Foundation of China (Grant Nos. 2010CB327605 and 2010CB328300)the National High-Technology Research and Development Program of China (Grant No. 2009AA01Z220)+3 种基金the Key Grant of the Chinese Ministry of Education (Grant No. 109015)the Discipline Co-construction Project of Beijing Municipal Commission of Education,China (Grant No. YB20081001301)the Open Fund of Key Laboratory of Information Photonics and Optical Communications (Beijing University of Posts and Telecommunications),Chinese Ministry of Educationthe Specialized Research Fund for the Doctoral Program of Beijing University of Posts and Telecommunications (Grant No. CX201023)
文摘With the full-vector plane-wave method (FVPWM) and the full-vector beam propagation method (FVBPM), the dependences of the band-gap and mode characteristics on material index and cladding structure parameter in anti- resonance guiding photonic crystal fibres (ARGPCFs) are sufficiently analysed. An ARGPCF operating in the near- infrared wavelength is shown. The influences of the high index cylinders, glass interstitial apexes and silica structure on the characteristics of band-gaps and modes are deeply investigated. The equivalent planar waveguide theory is used for analysing such an ARGPCF filled by the isotropic materials, and the resonance and the anti-resonance characteristics r:~n h~ w~|] r^r~dlrtpd
文摘The parallelism of saw guide motion locus against the blade is one of the main iterns in the testing of the geometric precision of the whole woodworking band saxving-machine. It reflects the making and mounting precisions of the sawguide device,having a direct effect on the working performance. the saw timber quality. and the safety (nature) of the woodworking band sawing-machine, so it is of great importance in the testing process of the band sawing-machine assembly and their going out of the plant.
基金SRF of HLJ (No.F2004-15)SRF of HIT (No.HIT2003.20)
文摘To analyze the stress of the guiding & positioning board and the effectiveness of the guiding & positioning device,according to guiding & positioning device's operational principle and structure,the guiding & positioning board's motion regular was analyzed by diagrammatical method based on 2 postulated conditions.Considering about the working conditions' change,simulations in 5 different kinds of working conditions were done to check the correctness of the motion regulars obtained by diagrammatical method.Simulation results prove that the motion regulars are right,the postulated conditions have no effect on the obtained motion regulars.According to the simulation results,the motion processs's characters were drawn out at the same time.
文摘AIM To evaluate the efficacy of endoscopic ultrasoundguided fine needle aspiration(EUS-FNA) of pancreatic head cancer when pushing(push method) or pulling the echoendoscope(pull method).METHODS Overall, 566 pancreatic cancer patients had their first EUS-FNA between February 2001 and December 2017. Among them, 201 who underwent EUS-FNA for pancreatic head lesions were included in this study. EUS-FNA was performed by the push method in 85 patients, the pull method in 101 patients and both the push and pull methods in 15 patients. After propensity score matching(age, sex, tumor diameter, and FNA needle), 85 patients each were stratified into the push and pull groups. Patient characteristics and EUSFNA-related factors were compared between the two groups.RESULTS Patient characteristics were not significantly different between the two groups. The distance to lesion was significantly longer in the push group than in the pull group(13.9 ± 4.9 mm vs 7.0 ± 4.9 mm, P < 0.01). The push method was a significant factor influencing the distance to lesion(≥ median 10 mm)(P < 0.01). Additionally, tumor diameter ≥ 25 mm(OR = 1.91, 95%CI: 1.02-3.58, P = 0.043) and the push method(OR = 1.91, 95%CI: 1.03-3.55, P = 0.04) were significant factors contributing to the histological diagnosis of malignancy.CONCLUSION The pull method shortened the distance between the endoscope and the lesion and facilitated EUS-FNA of pancreatic head cancer. The push method contributed to the histological diagnosis of pancreatic head cancer using EUS-FNA specimens.
文摘视差不连续区域和重复纹理区域的误匹配率高一直是影响双目立体匹配测量精度的主要问题,为此,本文提出一种基于多特征融合的立体匹配算法。首先,在代价计算阶段,通过高斯加权法赋予邻域像素点的权值,从而优化绝对差之和(Sum of Absolute Differences,SAD)算法的计算精度。接着,基于Census变换改进二进制链码方式,将邻域内像素的平均灰度值与梯度图像的灰度均值相融合,进而建立左右图像对应点的判断依据并优化其编码长度。然后,构建基于十字交叉法与改进的引导滤波器相融合的聚合方法,从而实现视差值再分配,以降低误匹配率。最后,通过赢家通吃(Winner Take All,WTA)算法获取初始视差,并采用左右一致性检测方法及亚像素法提高匹配精度,从而获取最终的视差结果。实验结果表明,在Middlebury数据集的测试中,所提SAD-Census算法的平均非遮挡区域和全部区域的误匹配率为分别为2.67%和5.69%,测量200~900 mm距离的平均误差小于2%;而实际三维测量的最大误差为1.5%。实验结果检验了所提算法的有效性和可靠性。
文摘目的:观察超声引导下股神经阻滞联合复元活血汤对全膝关节置换术后患者疼痛程度及膝关节功能的影响。方法:选择2020年5月至2022年5月就诊于武汉市中医医院骨科收治的拟行全膝关节置换术的60例膝骨关节炎患者,按照随机数字表法分为试验组和对照组,每组各30例。两组患者均给予人工全膝关节置换术,对照组于术后即刻行超声引导下股神经阻滞镇痛,试验组在对照组治疗的基础上口服复原活血汤。记录两组患者手术后第3天、第5天、第7天静息及被动屈曲20°、50°、70°时视觉模拟评分法(visual analogue scale,VAS)评分、患膝关节周缘肿胀差值、关节主动屈伸活动度、美国特种外科医院膝关节功能(hospital for special surgery,HSS)评分。结果:静息0°状态下,术后第3天试验组VAS评分高于对照组(P<0.05),但术后第5天、第7天两组患者VAS评分比较,差异无统计学意义(P>0.05)。被动屈曲20°、45°、70°状态下,术后第3天、第5天、第7天试验组VAS评分高于对照组(P<0.05)。在同一测量点,术后第3天、第5天、第7天试验组患肢肿胀差值大对照组(P<0.05)。术后第3天、第5天、第7天试验组膝关节主动屈曲角度大于对照组(P<0.05)。术后第3天、第5天、第7天试验组膝关节HSS评分高于对照组(P<0.05)。结论:将超声引导下股神经阻滞联合复元活血汤运用于全膝关节置换术后,可降低术后各时间段的静息及主动屈伸时的疼痛程度,缓解患肢肿胀程度,从而增加患膝活动范围,促进膝关节功能恢复。