BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model ...BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control.We designed a Tshaped magnet system to overcome these problems and verified its effectiveness via animal experiments.AIM To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs.METHODS Twelve beagles were randomly assigned to groups in which magnets of the Tshaped scheme(study group,n=6)or normal magnets(control group,n=6)were implanted into the trachea and esophagus separately under gastroscopy.Operation time,operation success rate,and accidental injury were recorded.After operation,the presence and timing of cough and the time of magnet shedding were observed.Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing,and gross specimens of TEFs were obtained.Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery,and gross specimens were obtained.Fistula size was measured in all animals,and then harvested fistula specimens were examined by hematoxylin and eosin(HE)and Masson trichrome staining.RESULTS The operation success rate was 100%for both groups.Operation time did not differ between the study group(5.25 min±1.29 min)and the control group(4.75 min±1.70 min;P=0.331).No bleeding,perforation,or unplanned magnet attraction occurred in any animal during the operation.In the early postoperative period,all dogs ate freely and were generally in good condition.Dogs in the control group had severe cough after drinking water at 6-9 d after surgery.X-ray indicated that the magnets had entered the stomach,and gastroscopy showed TEF formation.Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm±1.29 mm(range,3.52-6.56 mm).HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas.Dogs in the study group did not exhibit obvious coughing after surgery.X-ray examination 2 wk after surgery indicated fixed magnet positioning,and gastroscopy showed no change in magnet positioning.The magnets were removed using a snare under endoscopy,and TEF was observed.Gross specimens showed well-formed fistulas with a diameter of 6.11 mm±0.16 mm(range,5.92-6.36 mm),which exceeded that in the control group(P<0.001).Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining,and the structure was more regular than that in the control group.CONCLUSION Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets.Most importantly,this model offers better controllability,which improves the flexibility of follow-up studies.展开更多
BACKGROUND Previous studies have validated the efficacy of both magnetic compression and surgical techniques in creating rabbit tracheoesophageal fistula(TEF)models.Magnetic compression achieves a 100%success rate but...BACKGROUND Previous studies have validated the efficacy of both magnetic compression and surgical techniques in creating rabbit tracheoesophageal fistula(TEF)models.Magnetic compression achieves a 100%success rate but requires more time,while surgery,though less frequently successful,offers rapid model establishment and technical maturity in larger animal models.AIM To determine the optimal approach for rabbit disease modeling and refine the process.METHODS TEF models were created in 12 rabbits using both the modified magnetic compression technique and surgery.Comparisons of the time to model establishment,success rate,food and water intake,weight changes,activity levels,bronchoscopy findings,white blood cell counts,and biopsies were performed.In response to the failures encountered during modified magnetic compression modeling,we increased the sample size to 15 rabbit models and assessed the repeatability and stability of the models,comparing them with the original magnetic compression technique.RESULTS The modified magnetic compression technique achieved a 66.7%success rate,whereas the success rate of the surgery technique was 33.3%.Surviving surgical rabbits might not meet subsequent experimental requirements due to TEF-related inflammation.In the modified magnetic compression group,one rabbit died,possibly due to magnet corrosion,and another died from tracheal magnet obstruction.Similar events occurred during the second round of modified magnetic compression modeling,with one rabbit possibly succumbing to aggravated lung infection.The operation time of the first round of modified magnetic compression was 3.2±0.6 min,which was significantly reduced to 2.1±0.4 min in the second round,compared to both the first round and that of the original technique.CONCLUSION The modified magnetic compression technique exhibits lower stress responses,a simple procedure,a high success rate,and lower modeling costs,making it a more appropriate choice for constructing TEF models in rabbits.展开更多
BACKGROUND The treatment of postoperative anastomotic stenosis after excision of rectal cancer is challenging.Endoscopic balloon dilation and radial incision are not effective in all patients.We present a new endoscop...BACKGROUND The treatment of postoperative anastomotic stenosis after excision of rectal cancer is challenging.Endoscopic balloon dilation and radial incision are not effective in all patients.We present a new endoscopy-assisted magnetic compression technique(MCT)for the treatment of rectal anastomotic stenosis.We successfully applied this MCT to a patient who developed an anastomotic stricture after radical resection of rectal cancer.A 50-year-old man had undergone laparoscopic radical rectal cancer surgery at a local hospital 5 months ago.A colonoscopy performed 2 months ago indicated that the rectal anastomosis was narrow due to which ileostomy closure could not be performed.The patient came to the Magnetic Surgery Clinic of the First Affiliated Hospital of Xi'an Jiaotong University after learning that we had successfully treated patients with colorectal stenosis using MCT.We performed endoscopy-assisted magnetic compression surgery for rectal stenosis.The magnets were removed 16 d later.A follow-up colonoscopy performed after 4 months showed good anastomotic patency,following which,ileostomy closure surgery was performed.CONCLUSION MCT is a simple,non-invasive technique for the treatment of anastomotic stricture after radical resection of rectal cancer.The technique can be widely used in clinical settings.展开更多
BACKGROUNDThe treatment of postoperative anastomotic stenosis(AS)after resection of colorectalcancer is challenging.Endoscopic balloon dilation is used to treat stenosisin such cases,but some patients do not show impr...BACKGROUNDThe treatment of postoperative anastomotic stenosis(AS)after resection of colorectalcancer is challenging.Endoscopic balloon dilation is used to treat stenosisin such cases,but some patients do not show improvement even after multipleballoon dilations.Magnetic compression technique(MCT)has been used for gastrointestinalanastomosis,but its use for the treatment of postoperative AS aftercolorectal cancer surgery has rarely been reported.CASE SUMMARYWe report a 72-year-old man who underwent radical resection of colorectal cancerand ileostomy one year ago.An ileostomy closure was prepared six months ago,but colonoscopy revealed a narrowing of the rectal anastomosis.Endoscopic balloondilation was performed three times,but colonoscopy showed no significantimprovement in stenosis.The AS was successfully treated using MCT.CONCLUSIONMCT is a minimally invasive method that can be used for the treatment of postoperativeAS after colorectal cancer surgery.展开更多
BACKGROUND Clinically,tracheoesophageal fistula(TEF)is lack of effective surgical strategies.One reason is due to the lack of appropriate animal models of acquired TEF,which is usually complex and difficult.Recently,t...BACKGROUND Clinically,tracheoesophageal fistula(TEF)is lack of effective surgical strategies.One reason is due to the lack of appropriate animal models of acquired TEF,which is usually complex and difficult.Recently,the magnetic compression technique has been applied for digestive tract anastomosis or vascular anastomosis in animals.In this study,an animal model of TEF in dogs was developed by using the magnetic compression technique,hoping to provide a new method for mimicking TEF.AIM To establish a TEF model in dogs by using the magnetic compression technique.METHODS Six male beagles were used as models with two Nd-Fe-B permanent magnets for TEF.The parent magnet and the daughter magnet were placed in the cervical esophagus and trachea,respectively.The anterior wall of the esophagus and the posterior wall of the trachea were compressed when the two magnets coupled.After 4-6 d,the necrotic tissue between the two magnets fell off and the parent and daughter magnets disengaged from the target location,leaving a fistula.Gastroscopy/bronchoscopy,upper gastrointestinal contrast study,and histological analysis were performed.RESULTS The establishment of the TEF model in all six beagles was successful.The average time of magnet placement was 4.33±1.11 min(range,3-7 min).Mean time for the magnets to disengage from the target location was 4.67±0.75 d(range,4-6 d).TEFs were observed by gastroscopy/bronchoscopy and esophageal angiography.The gross anatomical structure of the esophagus and the trachea was in good condition.There was no esophageal mucosa or pseudostratified ciliated columnar epithelium at the site of the fistula according to histological analysis.CONCLUSION It is simple,feasible,and minimally invasive to use the magnetic compression technique for the establishment of the TEF model in dogs.展开更多
AIM: To explore the anatomical feasibility of portacaval shunt using a magnetic compression technique(MCT) in cadavers.METHODS: Computed tomography(CT) images of 30 portal hypertensive patients were obtained.The diame...AIM: To explore the anatomical feasibility of portacaval shunt using a magnetic compression technique(MCT) in cadavers.METHODS: Computed tomography(CT) images of 30 portal hypertensive patients were obtained.The diameters of the portal vein(PV),the inferior vena cava(IVC),and distance between the two structures were measured.Similar measurements were performed on 20 adult corpses.The feasibility of portacaval shunt based on those measurements was analyzed.First stage of the extrahepatic portacaval shunt using MCT was performed on five cadavers.Specifically,the PV and IVC were exposed through an abdominal incision of the cadavers.The parent magnet was introduced from the femoral vein and was delivered into the IVC by an anchor wire and a 5F Cook catheter.The daughter magnet was introduced into the PV through the splenic vein using aninterventional guide wire.When the daughter magnet met the parent magnet,they automatically clipped together and the first stage of the portacaval shunt was set up.RESULTS: The average diameters of the PV and the IVC measured from the 30 CT image were 14.39 ± 2.36 mm and 18.59 ± 4.97 mm,respectively,and the maximum and minimum distances between the PV and the IVC were 9.79 ± 4.56 mm and 9.50 ± 4.79 mm,respectively.From 20 cadavers,the average diameters of the PV and the IVC were 14.48 ± 1.47 mm and 24.71 ± 2.64 mm,and the maximum and minimum distances between the PV and the IVC were 10.14 ± 1.70 mm and 8.93 ± 1.17 mm,respectively.The distances between the PV and the IVC from both the CT images and the cadavers were within the effective length of portacaval anastomosis using MCT(30.30 ± 4.19 mm).The PV and IVC are in close proximity to each other with no intervening tissues or structures in between.Simulated surgeries of the first stage using MCT on five cadavers was successfully performed.CONCLUSION: Anatomically,extrahepatic portacaval shunt employing MCT is highly feasible in humans.展开更多
We present a new model of an electron gun for generating subrelativistic femtosecond (fs) electron pulses. The basic idea is to utilize a dc acceleration stage combined with a time focusing region, the time focusing...We present a new model of an electron gun for generating subrelativistic femtosecond (fs) electron pulses. The basic idea is to utilize a dc acceleration stage combined with a time focusing region, the time focusing electrode generates an electron energy chirp for bunching at the target. Without considering the space charge effects, simulations of the electron gun were carried out under the conditions of different dc voltages and various slopes of the voltage added on the time focusing electrode. Tracing and simulating large numbers of photoelectrons through Monte-Carlo and finite difference methods, the electron pulses with 1 ps can be compressed to 55 fs, which will allow significant advances in the field of ultrafast diagnosis.展开更多
Objective: To evaluate the effectiveness of conservative compression surgical suture techniques used for the management of pernicious placenta previa to conserve fertility in the subsequent pregnancies. Study Design: ...Objective: To evaluate the effectiveness of conservative compression surgical suture techniques used for the management of pernicious placenta previa to conserve fertility in the subsequent pregnancies. Study Design: This was a non-comparative retrospective study of 188 patients diagnosed with pernicious placenta previa who underwent cesarean section in The First Hospital of Jilin University, China, from 1 January 2013 to 1 January 2018. Successful group was defined as those in which the intraoperative bleeding was managed by either modified CHO or by B-lynch suture technique and those who had further intervention including hysterectomy were designated as failure group. Results: Out of 217 patients, 188 met inclusion criteria and 29 patients were excluded. In 188 cases, 183 (97.34%) cases successes and 5 (2.65%) cases had hysterectomy. Among included group, 118 patients (62.76%) had undergone emergency cesarean section and 70 patients (37.23%) underwent elective cesarean section. The emergency group had significantly lesser gestation period of gestation at the time of cesarean section (P = 0.021) and lower neonatal weight (P = 0.001) than that of elective group. The estimated blood loss during surgery was 500 - 3200 ml (mean: 925 ml). Additionally, the amount of bleeding was found to be significantly more in patient with intraoperative complication (P = 0.007) and in patient with implanted placenta (P 0.001). Conclusion: The conservative compression suture technique including modified CHO and B-lynch suture technique during the cesarean delivery is a feasible, safe and effective alternative conservative surgical technique for the management of bleeding in case of pernicious placenta previa. Besides good surgical outcome and proper neonatal result this technique also reduces the rate of hysterectomy, thus conserving the fertility.展开更多
In this paper, three techniques, line run coding, quadtree DF (Depth-First) representation and H coding for compressing classified satellite cloud images with no distortion are presented. In these three codings, the f...In this paper, three techniques, line run coding, quadtree DF (Depth-First) representation and H coding for compressing classified satellite cloud images with no distortion are presented. In these three codings, the first two were invented by other persons and the third one, by ourselves. As a result, the comparison among their compression rates is. given at the end of this paper. Further application of these image compression technique to satellite data and other meteorological data looks promising.展开更多
Data compression plays a key role in optimizing the use of memory storage space and also reducing latency in data transmission. In this paper, we are interested in lossless compression techniques because their perform...Data compression plays a key role in optimizing the use of memory storage space and also reducing latency in data transmission. In this paper, we are interested in lossless compression techniques because their performance is exploited with lossy compression techniques for images and videos generally using a mixed approach. To achieve our intended objective, which is to study the performance of lossless compression methods, we first carried out a literature review, a summary of which enabled us to select the most relevant, namely the following: arithmetic coding, LZW, Tunstall’s algorithm, RLE, BWT, Huffman coding and Shannon-Fano. Secondly, we designed a purposive text dataset with a repeating pattern in order to test the behavior and effectiveness of the selected compression techniques. Thirdly, we designed the compression algorithms and developed the programs (scripts) in Matlab in order to test their performance. Finally, following the tests conducted on relevant data that we constructed according to a deliberate model, the results show that these methods presented in order of performance are very satisfactory:- LZW- Arithmetic coding- Tunstall algorithm- BWT + RLELikewise, it appears that on the one hand, the performance of certain techniques relative to others is strongly linked to the sequencing and/or recurrence of symbols that make up the message, and on the other hand, to the cumulative time of encoding and decoding.展开更多
The random models of open-cell foams that can reflect the actual cell geometrical properties are constructed with the Voronoi technique. The compression process of elastic open-cell foams is simulated with the nonline...The random models of open-cell foams that can reflect the actual cell geometrical properties are constructed with the Voronoi technique. The compression process of elastic open-cell foams is simulated with the nonlinear calculation module of finite element analysis program. In order to get the general results applicable to this kind of materials, the dimensionless compressive stress is used and the stress-strain curves of foam models with different geometrical properties are obtained. Then, the influences of open-cell geometrical properties, including the shape of strut cross section, relative density and cell shape irregularity, on the compressive nonlinear mechani- cal performance are analyzed. In addition, the numerical results are compared with the predicted results of cubic staggering model. Nu- merical results indicate that the simulated results reflect the compressive process of foams quite well and the geometrical properties of cell have significant influences on the nonlinear mechanical behavior of foams.展开更多
The uniaxial compressive strength(UCS)of rock is an essential property of rock material in different relevant applications,such as rock slope,tunnel construction,and foundation.It takes enormous time and effort to obt...The uniaxial compressive strength(UCS)of rock is an essential property of rock material in different relevant applications,such as rock slope,tunnel construction,and foundation.It takes enormous time and effort to obtain the UCS values directly in the laboratory.Accordingly,an indirect determination of UCS through conducting several rock index tests that are easy and fast to carry out is of interest and importance.This study presents powerful boosting trees evaluation framework,i.e.,adaptive boosting machine,extreme gradient boosting machine(XGBoost),and category gradient boosting machine,for estimating the UCS of sandstone.Schmidt hammer rebound number,P-wave velocity,and point load index were chosen as considered factors to forecast UCS values of sandstone samples.Taylor diagrams and five regression metrics,including coefficient of determination(R2),root mean square error,mean absolute error,variance account for,and A-20 index,were used to evaluate and compare the performance of these boosting trees.The results showed that the proposed boosting trees are able to provide a high level of prediction capacity for the prepared database.In particular,itwas worth noting that XGBoost is the best model to predict sandstone strength and it achieved 0.999 training R^(2) and 0.958 testing R^(2).The proposed model had more outstanding capability than neural network with optimization techniques during training and testing phases.The performed variable importance analysis reveals that the point load index has a significant influence on predicting UCS of sandstone.展开更多
The current work is focused on the study of optical clearing of skeletal muscles under local compression.The experiments were performed on in vitro bovine skeletal muscle.The time dependence of optical clearing was st...The current work is focused on the study of optical clearing of skeletal muscles under local compression.The experiments were performed on in vitro bovine skeletal muscle.The time dependence of optical clearing was studied by monitoring the luminescence intensity of NaYF_(4)∶Er,Yb upconverting particles located under tissue layers.This study shows the possibility to use upconverting nanoparticles(UCNPs)both for studying the dynamics of the optical clearing of biological tissue under compression and to detect moments of cell wall damage under excessive pressure.The advantage of using UCNPs is the presence of several bands in their luminescence spectra,located both at close wavelengths and far apart.展开更多
This paper presents a hybrid technique for the compression of ECG signals based on DWT and exploiting the correlation between signal samples. It incorporates Discrete Wavelet Transform (DWT), Differential Pulse Code M...This paper presents a hybrid technique for the compression of ECG signals based on DWT and exploiting the correlation between signal samples. It incorporates Discrete Wavelet Transform (DWT), Differential Pulse Code Modulation (DPCM), and run-length coding techniques for the compression of different parts of the signal;where lossless compression is adopted in clinically relevant parts and lossy compression is used in those parts that are not clinically relevant. The proposed compression algorithm begins by segmenting the ECG signal into its main components (P-waves, QRS-complexes, T-waves, U-waves and the isoelectric waves). The resulting waves are grouped into Region of Interest (RoI) and Non Region of Interest (NonRoI) parts. Consequently, lossless and lossy compression schemes are applied to the RoI and NonRoI parts respectively. Ideally we would like to compress the signal losslessly, but in many applications this is not an option. Thus, given a fixed bit budget, it makes sense to spend more bits to represent those parts of the signal that belong to a specific RoI and, thus, reconstruct them with higher fidelity, while allowing other parts to suffer larger distortion. For this purpose, the correlation between the successive samples of the RoI part is utilized by adopting DPCM approach. However the NonRoI part is compressed using DWT, thresholding and coding techniques. The wavelet transformation is used for concentrating the signal energy into a small number of transform coefficients. Compression is then achieved by selecting a subset of the most relevant coefficients which afterwards are efficiently coded. Illustrative examples are given to demonstrate thresholding based on energy packing efficiency strategy, coding of DWT coefficients and data packetizing. The performance of the proposed algorithm is tested in terms of the compression ratio and the PRD distortion metrics for the compression of 10 seconds of data extracted from records 100 and 117 of MIT-BIH database. The obtained results revealed that the proposed technique possesses higher compression ratios and lower PRD compared to the other wavelet transformation techniques. The principal advantages of the proposed approach are: 1) the deployment of different compression schemes to compress different ECG parts to reduce the correlation between consecutive signal samples;and 2) getting high compression ratios with acceptable reconstruction signal quality compared to the recently published results.展开更多
In recent years,a wide range of gastrointestinal endoscopy techniques have been developed,such as endoscopic submucosal dissection(ESD)and endoscopic retrograde cholangiopancreatography(ERCP).Although ESD and ERCP hav...In recent years,a wide range of gastrointestinal endoscopy techniques have been developed,such as endoscopic submucosal dissection(ESD)and endoscopic retrograde cholangiopancreatography(ERCP).Although ESD and ERCP have an important role in gastrointestinal and biliary diseases,each technique has its limitations.Hybrid techniques that combine endoscopic and surgical procedures have emerged that have the advantages of different procedures and negate their limitations at the same time.Laparoscopic endoscopic cooperative surgery and modified laparoscopic endoscopic cooperative surgery combine ESD and laparoscopic techniques to resect submucosal tumors with minimum resection area.Air leak test by intraoperative endoscopy can effectively identify a mechanically insufficient anastomosis and decrease the complication rate.The rendezvous technique that combines percutaneous transhepatic biliary drainage and endoscopy can be performed as a rescue approach for the treatment of biliary obstruction,stenosis and bile duct injuries.For patients with simultaneous presence of stones in the gallbladder and the common bile duct,the laparoendoscopic rendezvous technique can perform ERCP and laparoscopic cholecystectomy at the same time and reduces the risk of pancreatic injury caused by ERCP.Biliobiliary and bilioenteric anastomosis using magnetic compression anastomosis is another choice for biliary obstruction.The most common used approach to deliver the magnets is by percutaneous-peroral tract.Laparoscopicassisted ERCP is a safe and highly effective therapy for patients who develop biliary diseases after Roux-en-Y gastric bypass surgery.展开更多
In Order to reduce the noise in the images and the physical storage, the wavelet-based image compression technique was applied to PIV processing in this paper. To study the effect of the wavelet bases, the standard PI...In Order to reduce the noise in the images and the physical storage, the wavelet-based image compression technique was applied to PIV processing in this paper. To study the effect of the wavelet bases, the standard PIV images were compressed by some known wavelet families, Daubechies, Coifman and Baylkin families with various compression ratios. It was found that a higher order wavelet base provided good compression performance for compressing PIV images. The error analysis of velocity field obtained indicated that the high compression ratio, even up to 64.1, can be realized without losing significant flow information in PIV processing. The wavelet compression technique of PIV was applied to the experimental images of jet flow and showed excellent performance. A reduced number of erroneous vectors can be realized by varying compression ratio. It can say that the wavelet image compression technique is very effective in PIV system.展开更多
In this paper, a new flux limiter scheme with the splitting technique is successfully incorporated into a multiple-relaxation-time lattice Boltzmann (LB) model for shacked compressible flows. The proposed flux limit...In this paper, a new flux limiter scheme with the splitting technique is successfully incorporated into a multiple-relaxation-time lattice Boltzmann (LB) model for shacked compressible flows. The proposed flux limiter scheme is efficient in decreasing the artificial oscillations and numerical diffusion around the interface. Due to the kinetic nature, some interface problems being difficult to handle at the macroscopic level can be modeled more naturally through the LB method. Numerical simulations for the Richtmyer-Meshkov instability show that with the new model the computed interfaces are smoother and more consistent with physical analysis. The growth rates of bubble and spike present a satisfying agreement with the theoretical predictions and other numerical simulations.展开更多
基金Supported by the Key Research&Development Program of Shaanxi Province of China,No.2024SF-YBXM-447Institutional Foundation of The First Affiliated Hospital of Xi’an Jiaotong University,No.2022MS-07+1 种基金Fundamental Research Funds for the Central Universities,No.xzy022023068Natural Science Foundation of Shaanxi Province,No.2023-JC-QN-0814.
文摘BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control.We designed a Tshaped magnet system to overcome these problems and verified its effectiveness via animal experiments.AIM To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs.METHODS Twelve beagles were randomly assigned to groups in which magnets of the Tshaped scheme(study group,n=6)or normal magnets(control group,n=6)were implanted into the trachea and esophagus separately under gastroscopy.Operation time,operation success rate,and accidental injury were recorded.After operation,the presence and timing of cough and the time of magnet shedding were observed.Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing,and gross specimens of TEFs were obtained.Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery,and gross specimens were obtained.Fistula size was measured in all animals,and then harvested fistula specimens were examined by hematoxylin and eosin(HE)and Masson trichrome staining.RESULTS The operation success rate was 100%for both groups.Operation time did not differ between the study group(5.25 min±1.29 min)and the control group(4.75 min±1.70 min;P=0.331).No bleeding,perforation,or unplanned magnet attraction occurred in any animal during the operation.In the early postoperative period,all dogs ate freely and were generally in good condition.Dogs in the control group had severe cough after drinking water at 6-9 d after surgery.X-ray indicated that the magnets had entered the stomach,and gastroscopy showed TEF formation.Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm±1.29 mm(range,3.52-6.56 mm).HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas.Dogs in the study group did not exhibit obvious coughing after surgery.X-ray examination 2 wk after surgery indicated fixed magnet positioning,and gastroscopy showed no change in magnet positioning.The magnets were removed using a snare under endoscopy,and TEF was observed.Gross specimens showed well-formed fistulas with a diameter of 6.11 mm±0.16 mm(range,5.92-6.36 mm),which exceeded that in the control group(P<0.001).Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining,and the structure was more regular than that in the control group.CONCLUSION Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets.Most importantly,this model offers better controllability,which improves the flexibility of follow-up studies.
基金Independent Scientific Research Project for Graduate Students of Beijing University of Chinese Medicine(2023),No.ZJKT2023020.
文摘BACKGROUND Previous studies have validated the efficacy of both magnetic compression and surgical techniques in creating rabbit tracheoesophageal fistula(TEF)models.Magnetic compression achieves a 100%success rate but requires more time,while surgery,though less frequently successful,offers rapid model establishment and technical maturity in larger animal models.AIM To determine the optimal approach for rabbit disease modeling and refine the process.METHODS TEF models were created in 12 rabbits using both the modified magnetic compression technique and surgery.Comparisons of the time to model establishment,success rate,food and water intake,weight changes,activity levels,bronchoscopy findings,white blood cell counts,and biopsies were performed.In response to the failures encountered during modified magnetic compression modeling,we increased the sample size to 15 rabbit models and assessed the repeatability and stability of the models,comparing them with the original magnetic compression technique.RESULTS The modified magnetic compression technique achieved a 66.7%success rate,whereas the success rate of the surgery technique was 33.3%.Surviving surgical rabbits might not meet subsequent experimental requirements due to TEF-related inflammation.In the modified magnetic compression group,one rabbit died,possibly due to magnet corrosion,and another died from tracheal magnet obstruction.Similar events occurred during the second round of modified magnetic compression modeling,with one rabbit possibly succumbing to aggravated lung infection.The operation time of the first round of modified magnetic compression was 3.2±0.6 min,which was significantly reduced to 2.1±0.4 min in the second round,compared to both the first round and that of the original technique.CONCLUSION The modified magnetic compression technique exhibits lower stress responses,a simple procedure,a high success rate,and lower modeling costs,making it a more appropriate choice for constructing TEF models in rabbits.
基金Supported by The Key Research and Development Program of Shaanxi Province of China,No.2024SF-YBXM-447The Institutional Foundation of The First Affiliated Hospital of Xi’an Jiaotong University,No.2022MS-07The Fundamental Research Funds for the Central Universities,No.xzy022023068。
文摘BACKGROUND The treatment of postoperative anastomotic stenosis after excision of rectal cancer is challenging.Endoscopic balloon dilation and radial incision are not effective in all patients.We present a new endoscopy-assisted magnetic compression technique(MCT)for the treatment of rectal anastomotic stenosis.We successfully applied this MCT to a patient who developed an anastomotic stricture after radical resection of rectal cancer.A 50-year-old man had undergone laparoscopic radical rectal cancer surgery at a local hospital 5 months ago.A colonoscopy performed 2 months ago indicated that the rectal anastomosis was narrow due to which ileostomy closure could not be performed.The patient came to the Magnetic Surgery Clinic of the First Affiliated Hospital of Xi'an Jiaotong University after learning that we had successfully treated patients with colorectal stenosis using MCT.We performed endoscopy-assisted magnetic compression surgery for rectal stenosis.The magnets were removed 16 d later.A follow-up colonoscopy performed after 4 months showed good anastomotic patency,following which,ileostomy closure surgery was performed.CONCLUSION MCT is a simple,non-invasive technique for the treatment of anastomotic stricture after radical resection of rectal cancer.The technique can be widely used in clinical settings.
基金the Institutional Foundation of The First Affiliated Hospital of Xi’an Jiaotong University,No.2022MS-07Fundamental Research Funds for the Central Universities,No.xzy022023068.
文摘BACKGROUNDThe treatment of postoperative anastomotic stenosis(AS)after resection of colorectalcancer is challenging.Endoscopic balloon dilation is used to treat stenosisin such cases,but some patients do not show improvement even after multipleballoon dilations.Magnetic compression technique(MCT)has been used for gastrointestinalanastomosis,but its use for the treatment of postoperative AS aftercolorectal cancer surgery has rarely been reported.CASE SUMMARYWe report a 72-year-old man who underwent radical resection of colorectal cancerand ileostomy one year ago.An ileostomy closure was prepared six months ago,but colonoscopy revealed a narrowing of the rectal anastomosis.Endoscopic balloondilation was performed three times,but colonoscopy showed no significantimprovement in stenosis.The AS was successfully treated using MCT.CONCLUSIONMCT is a minimally invasive method that can be used for the treatment of postoperativeAS after colorectal cancer surgery.
基金Supported by the National Natural Science Foundation of China,No.81700545the Natural Science Basic Research Plan of Shaanxi Province of China,No.2017JQ8021the Fundamental Research Funds for the Central Universities,No.xjj2018jchz14
文摘BACKGROUND Clinically,tracheoesophageal fistula(TEF)is lack of effective surgical strategies.One reason is due to the lack of appropriate animal models of acquired TEF,which is usually complex and difficult.Recently,the magnetic compression technique has been applied for digestive tract anastomosis or vascular anastomosis in animals.In this study,an animal model of TEF in dogs was developed by using the magnetic compression technique,hoping to provide a new method for mimicking TEF.AIM To establish a TEF model in dogs by using the magnetic compression technique.METHODS Six male beagles were used as models with two Nd-Fe-B permanent magnets for TEF.The parent magnet and the daughter magnet were placed in the cervical esophagus and trachea,respectively.The anterior wall of the esophagus and the posterior wall of the trachea were compressed when the two magnets coupled.After 4-6 d,the necrotic tissue between the two magnets fell off and the parent and daughter magnets disengaged from the target location,leaving a fistula.Gastroscopy/bronchoscopy,upper gastrointestinal contrast study,and histological analysis were performed.RESULTS The establishment of the TEF model in all six beagles was successful.The average time of magnet placement was 4.33±1.11 min(range,3-7 min).Mean time for the magnets to disengage from the target location was 4.67±0.75 d(range,4-6 d).TEFs were observed by gastroscopy/bronchoscopy and esophageal angiography.The gross anatomical structure of the esophagus and the trachea was in good condition.There was no esophageal mucosa or pseudostratified ciliated columnar epithelium at the site of the fistula according to histological analysis.CONCLUSION It is simple,feasible,and minimally invasive to use the magnetic compression technique for the establishment of the TEF model in dogs.
基金Supported by Key Project of Clinical Discipline of Ministry of Health Subordinates of China,No.2010105
文摘AIM: To explore the anatomical feasibility of portacaval shunt using a magnetic compression technique(MCT) in cadavers.METHODS: Computed tomography(CT) images of 30 portal hypertensive patients were obtained.The diameters of the portal vein(PV),the inferior vena cava(IVC),and distance between the two structures were measured.Similar measurements were performed on 20 adult corpses.The feasibility of portacaval shunt based on those measurements was analyzed.First stage of the extrahepatic portacaval shunt using MCT was performed on five cadavers.Specifically,the PV and IVC were exposed through an abdominal incision of the cadavers.The parent magnet was introduced from the femoral vein and was delivered into the IVC by an anchor wire and a 5F Cook catheter.The daughter magnet was introduced into the PV through the splenic vein using aninterventional guide wire.When the daughter magnet met the parent magnet,they automatically clipped together and the first stage of the portacaval shunt was set up.RESULTS: The average diameters of the PV and the IVC measured from the 30 CT image were 14.39 ± 2.36 mm and 18.59 ± 4.97 mm,respectively,and the maximum and minimum distances between the PV and the IVC were 9.79 ± 4.56 mm and 9.50 ± 4.79 mm,respectively.From 20 cadavers,the average diameters of the PV and the IVC were 14.48 ± 1.47 mm and 24.71 ± 2.64 mm,and the maximum and minimum distances between the PV and the IVC were 10.14 ± 1.70 mm and 8.93 ± 1.17 mm,respectively.The distances between the PV and the IVC from both the CT images and the cadavers were within the effective length of portacaval anastomosis using MCT(30.30 ± 4.19 mm).The PV and IVC are in close proximity to each other with no intervening tissues or structures in between.Simulated surgeries of the first stage using MCT on five cadavers was successfully performed.CONCLUSION: Anatomically,extrahepatic portacaval shunt employing MCT is highly feasible in humans.
基金supported the Young Scientists Fund of the National Natural Science Foundation of China(Grant No.60901036)the National Natural Science Foundation of China(Grant No.60777027)the Innovation Laboratory Fund of the Chinese Academy of Sciences(Grant No.CXJJ-10-S13)
文摘We present a new model of an electron gun for generating subrelativistic femtosecond (fs) electron pulses. The basic idea is to utilize a dc acceleration stage combined with a time focusing region, the time focusing electrode generates an electron energy chirp for bunching at the target. Without considering the space charge effects, simulations of the electron gun were carried out under the conditions of different dc voltages and various slopes of the voltage added on the time focusing electrode. Tracing and simulating large numbers of photoelectrons through Monte-Carlo and finite difference methods, the electron pulses with 1 ps can be compressed to 55 fs, which will allow significant advances in the field of ultrafast diagnosis.
文摘Objective: To evaluate the effectiveness of conservative compression surgical suture techniques used for the management of pernicious placenta previa to conserve fertility in the subsequent pregnancies. Study Design: This was a non-comparative retrospective study of 188 patients diagnosed with pernicious placenta previa who underwent cesarean section in The First Hospital of Jilin University, China, from 1 January 2013 to 1 January 2018. Successful group was defined as those in which the intraoperative bleeding was managed by either modified CHO or by B-lynch suture technique and those who had further intervention including hysterectomy were designated as failure group. Results: Out of 217 patients, 188 met inclusion criteria and 29 patients were excluded. In 188 cases, 183 (97.34%) cases successes and 5 (2.65%) cases had hysterectomy. Among included group, 118 patients (62.76%) had undergone emergency cesarean section and 70 patients (37.23%) underwent elective cesarean section. The emergency group had significantly lesser gestation period of gestation at the time of cesarean section (P = 0.021) and lower neonatal weight (P = 0.001) than that of elective group. The estimated blood loss during surgery was 500 - 3200 ml (mean: 925 ml). Additionally, the amount of bleeding was found to be significantly more in patient with intraoperative complication (P = 0.007) and in patient with implanted placenta (P 0.001). Conclusion: The conservative compression suture technique including modified CHO and B-lynch suture technique during the cesarean delivery is a feasible, safe and effective alternative conservative surgical technique for the management of bleeding in case of pernicious placenta previa. Besides good surgical outcome and proper neonatal result this technique also reduces the rate of hysterectomy, thus conserving the fertility.
文摘In this paper, three techniques, line run coding, quadtree DF (Depth-First) representation and H coding for compressing classified satellite cloud images with no distortion are presented. In these three codings, the first two were invented by other persons and the third one, by ourselves. As a result, the comparison among their compression rates is. given at the end of this paper. Further application of these image compression technique to satellite data and other meteorological data looks promising.
文摘Data compression plays a key role in optimizing the use of memory storage space and also reducing latency in data transmission. In this paper, we are interested in lossless compression techniques because their performance is exploited with lossy compression techniques for images and videos generally using a mixed approach. To achieve our intended objective, which is to study the performance of lossless compression methods, we first carried out a literature review, a summary of which enabled us to select the most relevant, namely the following: arithmetic coding, LZW, Tunstall’s algorithm, RLE, BWT, Huffman coding and Shannon-Fano. Secondly, we designed a purposive text dataset with a repeating pattern in order to test the behavior and effectiveness of the selected compression techniques. Thirdly, we designed the compression algorithms and developed the programs (scripts) in Matlab in order to test their performance. Finally, following the tests conducted on relevant data that we constructed according to a deliberate model, the results show that these methods presented in order of performance are very satisfactory:- LZW- Arithmetic coding- Tunstall algorithm- BWT + RLELikewise, it appears that on the one hand, the performance of certain techniques relative to others is strongly linked to the sequencing and/or recurrence of symbols that make up the message, and on the other hand, to the cumulative time of encoding and decoding.
基金National Natural Science Foundation of China (10572013) ECB Foundation (XK100060522)
文摘The random models of open-cell foams that can reflect the actual cell geometrical properties are constructed with the Voronoi technique. The compression process of elastic open-cell foams is simulated with the nonlinear calculation module of finite element analysis program. In order to get the general results applicable to this kind of materials, the dimensionless compressive stress is used and the stress-strain curves of foam models with different geometrical properties are obtained. Then, the influences of open-cell geometrical properties, including the shape of strut cross section, relative density and cell shape irregularity, on the compressive nonlinear mechani- cal performance are analyzed. In addition, the numerical results are compared with the predicted results of cubic staggering model. Nu- merical results indicate that the simulated results reflect the compressive process of foams quite well and the geometrical properties of cell have significant influences on the nonlinear mechanical behavior of foams.
基金funded by Act 211 Government of the Russian Federation,Contract No.02.A03.21.0011.
文摘The uniaxial compressive strength(UCS)of rock is an essential property of rock material in different relevant applications,such as rock slope,tunnel construction,and foundation.It takes enormous time and effort to obtain the UCS values directly in the laboratory.Accordingly,an indirect determination of UCS through conducting several rock index tests that are easy and fast to carry out is of interest and importance.This study presents powerful boosting trees evaluation framework,i.e.,adaptive boosting machine,extreme gradient boosting machine(XGBoost),and category gradient boosting machine,for estimating the UCS of sandstone.Schmidt hammer rebound number,P-wave velocity,and point load index were chosen as considered factors to forecast UCS values of sandstone samples.Taylor diagrams and five regression metrics,including coefficient of determination(R2),root mean square error,mean absolute error,variance account for,and A-20 index,were used to evaluate and compare the performance of these boosting trees.The results showed that the proposed boosting trees are able to provide a high level of prediction capacity for the prepared database.In particular,itwas worth noting that XGBoost is the best model to predict sandstone strength and it achieved 0.999 training R^(2) and 0.958 testing R^(2).The proposed model had more outstanding capability than neural network with optimization techniques during training and testing phases.The performed variable importance analysis reveals that the point load index has a significant influence on predicting UCS of sandstone.
基金This work was supported by the Russian Science Foundation,project no.19-12-00118.
文摘The current work is focused on the study of optical clearing of skeletal muscles under local compression.The experiments were performed on in vitro bovine skeletal muscle.The time dependence of optical clearing was studied by monitoring the luminescence intensity of NaYF_(4)∶Er,Yb upconverting particles located under tissue layers.This study shows the possibility to use upconverting nanoparticles(UCNPs)both for studying the dynamics of the optical clearing of biological tissue under compression and to detect moments of cell wall damage under excessive pressure.The advantage of using UCNPs is the presence of several bands in their luminescence spectra,located both at close wavelengths and far apart.
文摘This paper presents a hybrid technique for the compression of ECG signals based on DWT and exploiting the correlation between signal samples. It incorporates Discrete Wavelet Transform (DWT), Differential Pulse Code Modulation (DPCM), and run-length coding techniques for the compression of different parts of the signal;where lossless compression is adopted in clinically relevant parts and lossy compression is used in those parts that are not clinically relevant. The proposed compression algorithm begins by segmenting the ECG signal into its main components (P-waves, QRS-complexes, T-waves, U-waves and the isoelectric waves). The resulting waves are grouped into Region of Interest (RoI) and Non Region of Interest (NonRoI) parts. Consequently, lossless and lossy compression schemes are applied to the RoI and NonRoI parts respectively. Ideally we would like to compress the signal losslessly, but in many applications this is not an option. Thus, given a fixed bit budget, it makes sense to spend more bits to represent those parts of the signal that belong to a specific RoI and, thus, reconstruct them with higher fidelity, while allowing other parts to suffer larger distortion. For this purpose, the correlation between the successive samples of the RoI part is utilized by adopting DPCM approach. However the NonRoI part is compressed using DWT, thresholding and coding techniques. The wavelet transformation is used for concentrating the signal energy into a small number of transform coefficients. Compression is then achieved by selecting a subset of the most relevant coefficients which afterwards are efficiently coded. Illustrative examples are given to demonstrate thresholding based on energy packing efficiency strategy, coding of DWT coefficients and data packetizing. The performance of the proposed algorithm is tested in terms of the compression ratio and the PRD distortion metrics for the compression of 10 seconds of data extracted from records 100 and 117 of MIT-BIH database. The obtained results revealed that the proposed technique possesses higher compression ratios and lower PRD compared to the other wavelet transformation techniques. The principal advantages of the proposed approach are: 1) the deployment of different compression schemes to compress different ECG parts to reduce the correlation between consecutive signal samples;and 2) getting high compression ratios with acceptable reconstruction signal quality compared to the recently published results.
基金Supported by Key Research and Development Program of Science and Technology Department of Sichuan Province,No.2018GZ0088.
文摘In recent years,a wide range of gastrointestinal endoscopy techniques have been developed,such as endoscopic submucosal dissection(ESD)and endoscopic retrograde cholangiopancreatography(ERCP).Although ESD and ERCP have an important role in gastrointestinal and biliary diseases,each technique has its limitations.Hybrid techniques that combine endoscopic and surgical procedures have emerged that have the advantages of different procedures and negate their limitations at the same time.Laparoscopic endoscopic cooperative surgery and modified laparoscopic endoscopic cooperative surgery combine ESD and laparoscopic techniques to resect submucosal tumors with minimum resection area.Air leak test by intraoperative endoscopy can effectively identify a mechanically insufficient anastomosis and decrease the complication rate.The rendezvous technique that combines percutaneous transhepatic biliary drainage and endoscopy can be performed as a rescue approach for the treatment of biliary obstruction,stenosis and bile duct injuries.For patients with simultaneous presence of stones in the gallbladder and the common bile duct,the laparoendoscopic rendezvous technique can perform ERCP and laparoscopic cholecystectomy at the same time and reduces the risk of pancreatic injury caused by ERCP.Biliobiliary and bilioenteric anastomosis using magnetic compression anastomosis is another choice for biliary obstruction.The most common used approach to deliver the magnets is by percutaneous-peroral tract.Laparoscopicassisted ERCP is a safe and highly effective therapy for patients who develop biliary diseases after Roux-en-Y gastric bypass surgery.
文摘In Order to reduce the noise in the images and the physical storage, the wavelet-based image compression technique was applied to PIV processing in this paper. To study the effect of the wavelet bases, the standard PIV images were compressed by some known wavelet families, Daubechies, Coifman and Baylkin families with various compression ratios. It was found that a higher order wavelet base provided good compression performance for compressing PIV images. The error analysis of velocity field obtained indicated that the high compression ratio, even up to 64.1, can be realized without losing significant flow information in PIV processing. The wavelet compression technique of PIV was applied to the experimental images of jet flow and showed excellent performance. A reduced number of erroneous vectors can be realized by varying compression ratio. It can say that the wavelet image compression technique is very effective in PIV system.
基金Supported by the Science Foundation of Laboratory of Computational Physics, Science Foundation of China Academy of Engineering Physics under Grant Nos. 2009A0102005, 2009B0101012National Basic Research Program of China under Grant No. 2007CB815105+1 种基金National Natural Science Foundation of China under Grant Nos. 11074300, 11075021, and 11074303the Fundamental Research Funds for the Central Universities under Grant No. 2010YS03
文摘In this paper, a new flux limiter scheme with the splitting technique is successfully incorporated into a multiple-relaxation-time lattice Boltzmann (LB) model for shacked compressible flows. The proposed flux limiter scheme is efficient in decreasing the artificial oscillations and numerical diffusion around the interface. Due to the kinetic nature, some interface problems being difficult to handle at the macroscopic level can be modeled more naturally through the LB method. Numerical simulations for the Richtmyer-Meshkov instability show that with the new model the computed interfaces are smoother and more consistent with physical analysis. The growth rates of bubble and spike present a satisfying agreement with the theoretical predictions and other numerical simulations.