Decomposition experiments conducted with and without microbial processes are commonly used to study the effects of environmental microorganisms on the degradation of organic pollutants.However,the effects of biologica...Decomposition experiments conducted with and without microbial processes are commonly used to study the effects of environmental microorganisms on the degradation of organic pollutants.However,the effects of biological pretreatment (sterilization) on organic matter often have a negative impact on such experiments.Based on the principle of water total organic carbon (TOC) analysis,the effects of physical sterilization treatments on determination of TOC and other water quality parameters were investigated.The results revealed that two conventional physical sterilization treatments,autoclaving and 60 Co γ-radiation sterilization,led to the direct decomposition of some organic pollutants,resulting in remarkable errors in the analysis of TOC in water samples.Furthermore,the extent of the errors varied with the intensity and the duration of sterilization treatments.Accordingly,a novel sterilization method for water samples,0.45 μm micro-filtration coupled with ultraviolet radiation (MCUR),was developed in the present study.The results indicated that the MCUR method was capable of exerting a high bactericidal effect on the water sample while significantly decreasing the negative impact on the analysis of TOC and other water quality parameters.Before and after sterilization treatments,the relative errors of TOC determination could be controlled to lower than 3% for water samples with different categories and concentrations of organic pollutants by using MCUR.展开更多
A simple harmonic motion is proposed to make the membrane move in a simpleharmonic way so as to enhance the membrane filtration, and minimize the membrane fouling andconcentration polarization. The velocity distributi...A simple harmonic motion is proposed to make the membrane move in a simpleharmonic way so as to enhance the membrane filtration, and minimize the membrane fouling andconcentration polarization. The velocity distribution and pressure distribution are deduced from theNavier-Stokes equation on the basis of a laminar flow when the membrane rotates at the speed of Asin(αt). And then the shear stress, shear force, moment of force on the membrane surface and powerconsumed by viscous force are calculated. The velocity distribution demonstrates that the phase ofmembrane velocity does not synchronize with that of shear stress. The simple harmonic motion canresult in self-cleaning, optimize energy utilization, provide the velocity field with instability,and make the feed fluid fluctuation. It also results in higher shear stress on the membrane surfacethan the constant motion when they consume the same quantitative energy.展开更多
基金supported by the National Natural Science Foundation of China (No. 40821140540)the National High Technology Research and Development Program (863) of China (No. 2007AA10Z218)
文摘Decomposition experiments conducted with and without microbial processes are commonly used to study the effects of environmental microorganisms on the degradation of organic pollutants.However,the effects of biological pretreatment (sterilization) on organic matter often have a negative impact on such experiments.Based on the principle of water total organic carbon (TOC) analysis,the effects of physical sterilization treatments on determination of TOC and other water quality parameters were investigated.The results revealed that two conventional physical sterilization treatments,autoclaving and 60 Co γ-radiation sterilization,led to the direct decomposition of some organic pollutants,resulting in remarkable errors in the analysis of TOC in water samples.Furthermore,the extent of the errors varied with the intensity and the duration of sterilization treatments.Accordingly,a novel sterilization method for water samples,0.45 μm micro-filtration coupled with ultraviolet radiation (MCUR),was developed in the present study.The results indicated that the MCUR method was capable of exerting a high bactericidal effect on the water sample while significantly decreasing the negative impact on the analysis of TOC and other water quality parameters.Before and after sterilization treatments,the relative errors of TOC determination could be controlled to lower than 3% for water samples with different categories and concentrations of organic pollutants by using MCUR.
文摘A simple harmonic motion is proposed to make the membrane move in a simpleharmonic way so as to enhance the membrane filtration, and minimize the membrane fouling andconcentration polarization. The velocity distribution and pressure distribution are deduced from theNavier-Stokes equation on the basis of a laminar flow when the membrane rotates at the speed of Asin(αt). And then the shear stress, shear force, moment of force on the membrane surface and powerconsumed by viscous force are calculated. The velocity distribution demonstrates that the phase ofmembrane velocity does not synchronize with that of shear stress. The simple harmonic motion canresult in self-cleaning, optimize energy utilization, provide the velocity field with instability,and make the feed fluid fluctuation. It also results in higher shear stress on the membrane surfacethan the constant motion when they consume the same quantitative energy.