期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Endovascular Embolization of Pseudoaneurysms Complicating Pancreatitis Using Microcoils: Case Series 被引量:1
1
作者 Kishor Taori Jawahar Rathod +5 位作者 Amit Disawal Rajesh Mundhada Atul Rewatkar Vishal Bakare Prasad Wavare Rakhi P. Puria 《Open Journal of Radiology》 2013年第1期33-40,共8页
Purpose: To determine whether endovascular embolization of pseudoaneurysms complicating pancreatitis with microcoils was associated with better therapeutic outcome. Materials and Method: The prospective clinical study... Purpose: To determine whether endovascular embolization of pseudoaneurysms complicating pancreatitis with microcoils was associated with better therapeutic outcome. Materials and Method: The prospective clinical study was carried out in the Department of Interventional Radiology for a period of 2 years extending from May 2010 upto August 2012 on 16 male patients in the age group of about 30 - 55 years, with each one of them having vascular complications as a sequel to pancreatitis, after obtaining well informed written consent from each one of them. Results: The outcome of the procedure was judged by the following parameters—a) Restoration of the blood pressure of the patient;b) Cessation of the hemetemesis and malena;c) Reduction in abdominal pain and discomfort and d) Overall improvement in the general condition of the patient. Each of the patients had been on follow up for at least 6 months, except 2 of them, with no new complaints in any of them. The procedure related mortality was none. Conclusion: Vascular complications of pancreatitis need immediate and accurate diagnosis and prompt treatment. Micro coil embolisation, is a minimally invasive technique which helps to exclude the pseudoaneurysm from the circulation and thus reduces the scope for massive life threatening internal hemorrhage, and is a better alternative to surgery. 展开更多
关键词 PANCREATITIS RUPTURED PSEUDOANEURYSMS VISCERAL ARTERIES microcoils
下载PDF
Endovascular embolisation of Giant Ruptured Proximal Splenic Arterial Pseudoaneurysm Using Microcoils &Glue: Case Report 被引量:1
2
作者 Jawahar Rathod Kishor Taori +7 位作者 Sachin Dhomne Prakash Pawar Devkaran Vaghasiya Amit Disawal Amrita Guha Kiran Naiknavare Rahul Agale Prajwleet Gour 《Surgical Science》 2011年第5期290-293,共4页
Splenic artery aneurysms (SAA) are third most common intra-abdominal aneurysm (after aneurysms of the abdominal aorta and iliac arteries). A splenic artery aneurysm larger than 3 cm is even rare. Splenic artery aneury... Splenic artery aneurysms (SAA) are third most common intra-abdominal aneurysm (after aneurysms of the abdominal aorta and iliac arteries). A splenic artery aneurysm larger than 3 cm is even rare. Splenic artery aneurysms are fatal vascular lesions if ruptured. The incidence of rupture is increased in larger aneurysms. Transcatheter arterial embolization is an alternative method of treatment in a patient with splenic arterial aneurysm which has relative lower morbidity and mortality than surgical procedures. Here, we report a case of giant ruptured proximal splenic artery pseudoaneurysm detected by contrast enhanced computed tomography (CECT) & referred to Interventional Radiology for Transcatheter arterial embolisation. 展开更多
关键词 PROXIMAL PSEUDOANEURYSM microcoils GLUE Pancreatitis
下载PDF
High-density stacked microcoils integrated microminiaturized electromagnetic vibration energy harvester for self-powered acceleration sensing
3
作者 HOU XiaoJuan ZHANG RuoYang +6 位作者 BI XiaoXue ZHAO HuiPeng ZHANG Jie ZHU Jie GENG WenPing HE Jian CHOU XiuJian 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2023年第12期3369-3380,共12页
With the rapid development of microelectronics and flexible electronics technology,self-powered sensors have significant application prospects in human-machine interface systems and Internet of Things.However,piezoele... With the rapid development of microelectronics and flexible electronics technology,self-powered sensors have significant application prospects in human-machine interface systems and Internet of Things.However,piezoelectric-and triboelectricbased sensors have low current output and are easily affected,while electromagnetic-based sensors are difficult to miniaturize.This work proposes a high-density stacked microcoil integrated microminiaturized electromagnetic vibration energy harvester(EVEH).The double-layer high-density microcoil is fabricated on both sides of the flexible polyimide substrate interconnected via the central through-hole.Owing to reduced single coil line width,line spacing,and stacked structure,the number of turns can be substantially enhanced.Moreover,the relative position of the coils and magnet has a considerable influence on the performances;due to the huge change rate in magnetic flux when the coil is placed in the radial direction of the magnet than in the axial direction,the open-circuit voltage in the radial direction is 10 times greater.The microcoil can maintain good performance at high,low temperatures and under bending conditions.When the distance between the ends of the coil changes from 2 to 20 mm in 2 mm steps,the bending angle of the coil changes from 45°to 270°in 45°steps;furthermore,when the coil is exposed to-40and 60℃conditions,the coil resistance is maintained at approximately 447Ω.The peak open-circuit voltage of three-piece microcoils reaches 0.41 V at 4 Hz under 2g,and the output voltage and current increase with an increasing number of stacked layers.These excellent properties indicate that EVEH can be used for self-powered acceleration sensing.The sensitivity is measured to be 0.016 V/(m/s^(2))with a correlation coefficient of 0.979 over the acceleration range of 1–18 m/s^(2).Thus,the developed microminiaturized EVEH has enormous potential for self-powered sensing applications in confined spaces and harsh environments. 展开更多
关键词 electromagnetic vibration energy harvester axial direction radial direction high-density stacked microcoils acceleration sensor
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部