期刊文献+
共找到60篇文章
< 1 2 3 >
每页显示 20 50 100
Studying a kind of portable ultra-bright microfocus x-ray source
1
作者 王凯歌 王雷 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第5期1807-1813,共7页
This paper studies the properties of a kind of portable ultra-bright microfocus x-ray source with the Monte-Carlo method in detail. The new x-ray source consists of an electron-emission system, an electrostatic focusi... This paper studies the properties of a kind of portable ultra-bright microfocus x-ray source with the Monte-Carlo method in detail. The new x-ray source consists of an electron-emission system, an electrostatic focusing system and a metal target. A crystal Lanthanum Hexaboride cathode, a Wehnelt grid and an extracted electrode compose the triode electrode electron-gun system. Two equal radius cylinder electrodes form the focusing system. The key factors determining the focus properties of the electron beam such as the ratio Dw/H, grid bias Vg, and the properties of the extracted electrode arc numerically studied. The calculated results reveal that when Dw/H, Vg, the length of the extracted electrode, and the distance between the grid and the extracted electrode equals 5, q).6 kV, 10 mm, and 8 mm respectively, the electron beam focal spot can be concentrated down to 9 μm in radius and a reasonable focal length about 72.5 mm can be achieved, at the same time, the cathode emission currents can be as high as 30 mA. 展开更多
关键词 microfocus x-ray source high brightness micro-focal spot Monte-Carlo method
下载PDF
Two Monte Carlo-based simulators for imaging-system modeling and projection simulation of flat-panel X-ray source
2
作者 Meng-Ke Qi Ting He +7 位作者 Yi-Wen Zhou Jing Kang Zeng-Xiang Pan Song Kang Wang-Jiang Wu Jun Chen Ling-Hong Zhou Yuan Xu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期31-46,共16页
The advantages of a flat-panel X-ray source(FPXS)make it a promising candidate for imaging applications.Accurate imaging-system modeling and projection simulation are critical for analyzing imaging performance and res... The advantages of a flat-panel X-ray source(FPXS)make it a promising candidate for imaging applications.Accurate imaging-system modeling and projection simulation are critical for analyzing imaging performance and resolving overlapping projection issues in FPXS.The conventional analytical ray-tracing approach is limited by the number of patterns and is not applicable to FPXS-projection calculations.However,the computation time of Monte Carlo(MC)simulation is independent of the size of the patterned arrays in FPXS.This study proposes two high-efficiency MC projection simulators for FPXS:a graphics processing unit(GPU)-based phase-space sampling MC(gPSMC)simulator and GPU-based fluence sampling MC(gFSMC)simulator.The two simulators comprise three components:imaging-system modeling,photon initialization,and physical-interaction simulations in the phantom.Imaging-system modeling was performed by modeling the FPXS,imaging geometry,and detector.The gPSMC simulator samples the initial photons from the phase space,whereas the gFSMC simulator performs photon initialization from the calculated energy spectrum and fluence map.The entire process of photon interaction with the geometry and arrival at the detector was simulated in parallel using multiple GPU kernels,and projections based on the two simulators were calculated.The accuracies of the two simulators were evaluated by comparing them with the conventional analytical ray-tracing approach and acquired projections,and the efficiencies were evaluated by comparing the computation time.The results of simulated and realistic experiments illustrate the accuracy and efficiency of the proposed gPSMC and gFSMC simulators in the projection calculation of various phantoms. 展开更多
关键词 Flat-panel x-ray source(FPXS) Imaging-system modeling Projection simulation Monte Carlo-based simulators
下载PDF
Beam and image experiment of beam deflection electron gun for distributed X-ray sources 被引量:7
3
作者 Cheng-Jun Tan Chuan-Xiang Tang +7 位作者 Wen-Hui Huang Qing-Xiu Jin Ying-Chao Du Qun Luo Pei-Dong Wu Dong-Hai Liu Lu-Ming Zhang Cong Xu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期127-138,共12页
Distributed X-ray sources comprise a single vacuum chamber containing multiple X-ray sources that are triggered and emit X-rays at a specific time and location. This process facilitates an application for innovative s... Distributed X-ray sources comprise a single vacuum chamber containing multiple X-ray sources that are triggered and emit X-rays at a specific time and location. This process facilitates an application for innovative system concepts in X-ray and computer tomography. This paper proposes a novel electron beam focusing, shaping,and deflection electron gun for distributed X-ray sources.The electron gun uses a dispenser cathode as an electron emitter, a mesh grid to control emission current, and two electrostatic lenses for beam shaping, focusing, and deflection. Novel focusing and deflecting electrodes were designed to increase the number of focal spots in the distributed source. Two identical half-rectangle opening electrodes are controlled by adjusting the potential of the two electrodes to control the electron beam trajectory, and then, multifocal spots are obtained on the anode target. The electron gun can increase the spatial density of the distributed X-ray sources, thereby improving the image quality. The beam experimental results show that the focal spot sizes of the deflected(deflected amplitude 10.5 mm)and non-deflected electron beams at full width at half maximum are 0.80 mm 90.50 mm and 0.55 mm 90.40 mm, respectively(anode voltage 160 kV; beam current 30 mA). The imaging experimental results demonstrate the excellent spatial resolution and time resolution of an imaging system built with the sources, which has an excellent imaging effect on a field-programmable gate array chip and a rotating metal disk. 展开更多
关键词 BEAM DEFLECTION electron GUN x-ray imaging DISTRIBUTED x-ray sources STATIONARY CT
下载PDF
Laser-produced plasma helium-like titanium Kα x-ray source and its application to Rayleigh-Taylor instability study 被引量:1
4
作者 王瑞荣 陈伟民 +2 位作者 王伟 董佳钦 肖沙里 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期362-368,共7页
Several experiments are performed on the ShenGuang-Ⅱ laser facility to investigate an x-ray source and test radiography concepts. X-ray lines emitted from laser-produced plasmas are the most practical means of genera... Several experiments are performed on the ShenGuang-Ⅱ laser facility to investigate an x-ray source and test radiography concepts. X-ray lines emitted from laser-produced plasmas are the most practical means of generating these high intensity sources. By using a time-integrated space-resolved keV spectroscope and pinhole camera, potential helium-like titanium Kα x-ray backlighting (radiography) line source is studied as a function of laser wavelength, ratio of pre-pulse intensity to main pulse intensity, and laser intensity (from 7.25 to ~ 11.3 × 10^15 W/cm2). One-dimensional radiography using a grid consisting of 5 #m Au wires on 16 μm period and the pinhole-assisted point projection is tested. The measurements show that the size of the helium-like titanium Ka source from a simple foil target is larger than 100 ~m, and relative x-ray line emission conversion efficiency ~x from the incident laser light energy to helium- like titanium K-shell spectrum increases significantly with pre-pulse intensity increasing, increases rapidly with laser wavelength decreasing, and increases moderately with main laser intensity increasing. It is also found that a gold gird foils can reach an imaging resolution better than 5-μm featured with high contrast. It is further demonstrated that the pinhole-assisted point projection at such a level will be a novel two-dimensional imaging diagnostic technique for inertial confinement fusion experiments. 展开更多
关键词 x-ray source plasma diagnostic techniques x-ray spectra
下载PDF
Optimization of 4.7-keV X-ray titanium sources driven by 100-ps laser pulses 被引量:1
5
作者 熊俊 董佳钦 +4 位作者 贾果 王瑞荣 王伟 傅思祖 郑无敌 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第6期454-458,共5页
An experiment with thin titanium foils irradiated by two pulses delayed in time is conducted on the bnenguang-Il laser facility. A prepulse induces an underdense plasma, 2-ns later a main pulse (λL ≈ 0.35 μm, EL ... An experiment with thin titanium foils irradiated by two pulses delayed in time is conducted on the bnenguang-Il laser facility. A prepulse induces an underdense plasma, 2-ns later a main pulse (λL ≈ 0.35 μm, EL ≈120 J, τL ≈100 ps) is injected into the underdense plasma and produces strong line emission from the titanium K shell (i.e., Hea at 4.7 keV). Data show that the intensity of 4.7-keV X-ray emission with the prepulse is approximately twice more than without the prepulse, and can be used as a backlighting source satisfying the diagnostic requirements for dense plasma probing. High- quality plasma images are obtained with the backlighfing 4.7-keV X-rays in a Rayleigh-Taylor hydrodynamic instability experiment. 展开更多
关键词 x-ray source PREPULSE titanium foil
下载PDF
Development of a seven-cell S-band standing-wave RF-deflecting cavity for Tsinghua Thomson scattering X-ray source 被引量:1
6
作者 Xian-Cai Lin Hao Zha +4 位作者 Jia-Ru Shi Liu-Yuan Zhou Shuang Liu Jian Gao Huai-Bi Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第4期20-29,共10页
A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and p... A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and provided a deflecting voltage of 4.2 MV with an input power of 2.5 MW.Bunch length diagnoses of electron beams with energies up to 39 MeV have been performed.In this article,the RF design of the cavity using HFSS,fabrication,and RF test processes are reviewed.High-power operation with accelerated beams and calibration of the deflecting voltage are also presented. 展开更多
关键词 Deflecting RF cavity Standing wave Bunchlength measurement Thomson x-ray source
下载PDF
Experimental Study of the X-Ray Radiation Source at Approximately Constant Radiation Temperature 被引量:1
7
作者 宋天明 杨家敏 +2 位作者 杨冬 李志超 尚万里 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第11期1108-1111,共4页
An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse. A simple theoretical model based on power balance is used to design the... An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse. A simple theoretical model based on power balance is used to design the shape of the drive laser pulse. Experiments are carried out on the Shenguang III prototype laser facility, and the experimentM results are presented for radiation sources with the flat-top lasting about 2.5 ns at two different peak temperatures of about 150 eV and 170 eV, respectively, including the the drive laser pulses and the time integrated possible improvements are discussed. time histories of the temperatures, the shapes of radiation spectra. The validity of the model and 展开更多
关键词 x-ray radiation source laser pulse shaping power balance
下载PDF
Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-ray
8
作者 Zhi-Jun Chi Hong-Ze Zhang +7 位作者 Jin Lin Xuan-Qi Zhang Hao Ding Qi-Li Tian Zhi Zhang Ying-Chao Du Wen-Hui Huang Chuan-Xiang Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期41-50,共10页
Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of th... Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy. 展开更多
关键词 x-ray fluorescence computed tomography Compton scattering computed tomography Linear polarization Thomson scattering x-ray source Monte Carlo simulation
下载PDF
Scanning Microfocus Small Angle X-ray Scattering Study of the Avian Eggshell
9
作者 D. Lammie M. M. Bain +1 位作者 S. E. Solomon T. J. Wess 《Journal of Bionic Engineering》 SCIE EI CSCD 2006年第1期11-18,共8页
Synchrotron microfocus small angle X-ray scattering was used to investigate the nanostructure and microscopic variation of eggshells. It uses a microbeam allowing the ability to probe interactions between the organic ... Synchrotron microfocus small angle X-ray scattering was used to investigate the nanostructure and microscopic variation of eggshells. It uses a microbeam allowing the ability to probe interactions between the organic and inorganic components at nanometer level and is ideal for mapping over small areas to obtain a detailed analysis of structural variations. Thin sections of eggshells were scanned from the shell membrane (inner) to the cuticle (outer) surface. The data collected was used to produce two-dimensional maps showing microscopic changes within the different layers of the eggshell. The structural alterations ap- parently could have implications at the macroscopic level of the resulting eggshell. As the organic matrix is embedded within the eggshell this may contribute to the variations observed in calcite crystal form and texture, Structural information obtained about a biomaterial at different length scales is important in relating the structure to its functional properties. This knowledge and the principles behind the formation of biomaterials could be used in the attempt of bioengineering new systems. 展开更多
关键词 biomaterial EGGSHELL NANOSTRUCTURE microfocus small angle x-ray scattering
下载PDF
Numerical simulation for all-optical Thomson scattering X-ray source
10
作者 谭放 朱斌 +5 位作者 韩丹 辛建婷 赵宗清 曹磊峰 谷渝秋 张保汉 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第3期249-255,共7页
Energy spectra, angular distributions, and temporal profiles of the photons produced by an all-optical Thomson scat- tering X-ray source are explored through numerical simulations based on the parameters of the SILEX-... Energy spectra, angular distributions, and temporal profiles of the photons produced by an all-optical Thomson scat- tering X-ray source are explored through numerical simulations based on the parameters of the SILEX-I laser system (800 nm, 30 fs, 300 TW) and the previous wakefield acceleration experimental results. The simulation results show that X-ray pulses with a duration of 30 fs and an emission angle of 50 mrad can be produced from such a source. Using the optimized electron parameters, X-ray pulses with better directivity and narrower energy spectra can be obtained. Besides the electron parameters, the laser parameters such as the wavelength, pulse duration, and spot size also affect the X-ray yield, the angular distribution, and the maximum photon energy, except the X-ray pulse duration which is slightly changed for the case of ultrafast laser-electron interaction. 展开更多
关键词 ultrashort laser wakefield acceleration Thomson scattering x-ray source
下载PDF
Biomedical X-ray Imaging Enabled by Carbon Nanotube X-ray Sources
11
作者 Guohua Cao 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2018年第4期529-536,615,共9页
Although discovered more than 100 years ago, X-ray source technology has evolved rather slowly. The recent invention of the carbon nanotube (CNT) X-ray source technology holds great promise to revolutionize the fiel... Although discovered more than 100 years ago, X-ray source technology has evolved rather slowly. The recent invention of the carbon nanotube (CNT) X-ray source technology holds great promise to revolutionize the field of biomedical X-ray imaging. CNT X-ray sources have been successfully adapted to several biomedical imaging applications including dynamic rnicro-CT of small animals and stationary breast tomosynthesis of breast cancers. Yet their more irnportant biomedical imaging applications still lie ahead in the future, with the devel- oprnent of stationary rnulti-source CT as a noteworthy exarnple. 展开更多
关键词 Biomedical imaging x-ray imaging x-ray source Carbon nanotube x-raysource Carbon nanotube Field emission Cornputed tornography Breast tornosynthesis
下载PDF
Low Energy Plasma Focus as an Intense X-ray Source for Radiography
12
作者 S.Hussain M.Zakaullah +1 位作者 Shujaat Ali A.Waheed 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第3期2296-2300,共5页
Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode ... Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energywindows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry isfound to be (27.3+-1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52+-0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at theanode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device asan intense X-ray source for radiography is demonstrated. 展开更多
关键词 plasma focus x-ray source RADIOGRAPHY
下载PDF
Phase Imaging Using Laser-produced X-ray Sources
13
作者 程静 张长学 韩申生 《Plasma Science and Technology》 SCIE EI CAS CSCD 2000年第4期411-413,共3页
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. We established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profil... A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. We established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging. 展开更多
关键词 Phase Imaging Using Laser-produced x-ray sources THAN
下载PDF
Self Consistent Calibration of Detectors and Sources for Hard and Soft X-Ray Diagnostics
14
作者 Danilo Pacella Afra Romano +3 位作者 Seung Hun Lee Federica Causa Lori Gabellieri Wonho Choe 《Modern Instrumentation》 2014年第3期13-23,共11页
X-Ray sources, detectors and optical components are now used in a wide range of applications. What is crucial is the absolute calibration of such devices to permit a quantitative assessment of the system under study. ... X-Ray sources, detectors and optical components are now used in a wide range of applications. What is crucial is the absolute calibration of such devices to permit a quantitative assessment of the system under study. A new X-ray laboratory has been built in Frascati (ENEA) to develop diagnostics for nuclear fusion experiments and study applications of these X-ray techniques in other domains, like new material science, non destructive tests and so on. An in-house developed selfconsistent calibration procedure is described that permits the absolute calibration of sources (X-ray emitted fluxes) and detectors (detection efficiencies) as function of the X-ray photon energy, in the range 2 - 120 keV. The calibration procedure involves the use of an in-house developed code that also predicts the spectral response of any detector in any experimental condition that can be setup in the laboratory. The procedure has been then applied for the calibration and characterisation of gas and solid state imaging detectors, such as Medipix-2, GEM gas detector, CCD camera, Cd-Te C-MOS imager, demonstrating the versatility of the method developed here. 展开更多
关键词 x-ray Detector x-ray source ABSOLUTE CALIBRATION Plasma Physics DIAGNOSTICS
下载PDF
Research on the Influence of X-ray Phase Contrast Imaging Parameters with Micro-focus Source
15
作者 WU jie WANG Yan +3 位作者 CHEN Jia-bi CHENG Jing-hai ZHANG Xue-long NIE Sheng-dong 《Chinese Journal of Biomedical Engineering(English Edition)》 2011年第1期29-35,共7页
X-ray in-line phase contrast imaging enables weakly to absorb specimens to be imaged successfully with high resolution and definition. In this paper we use computer simulation method to analyze how each parameter infl... X-ray in-line phase contrast imaging enables weakly to absorb specimens to be imaged successfully with high resolution and definition. In this paper we use computer simulation method to analyze how each parameter influences the quality of the image. It can avoid wasting unnecessary time and materials in the course of experiment to get ideal images. 展开更多
关键词 x-ray phase contrast micro-focus source SIMULATION
下载PDF
A Reflectron Time-of-Flight Mass Spectrometer with a Nano-Electrospray Ionization Source for Study of Metal Cluster Compounds
16
作者 吴小虎 谢华 +3 位作者 刘志凌 苏海峰 林水潮 唐紫超 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2016年第4期401-406,I0001,共7页
An experiment facility has been set up for the study of metal cluster compounds in our laboratory, which consists of a nano-electrospray ionization source, an ion transmission and focus system, and a reflectron time-o... An experiment facility has been set up for the study of metal cluster compounds in our laboratory, which consists of a nano-electrospray ionization source, an ion transmission and focus system, and a reflectron time-of-fight mass spectrometer. Taking advantage of the nano-electrospray ionization source, polyvalent ions are usually produced in the "ionization" process and the obtained mass resolution of the equipment is over 8000. The molecular ion peaks of metal cluster compounds [Au20(PPhpy2)10Cl2](SbF6)4, where PPhpy2=bis(2- pyridyl)phenylphosphine, and [AuaAg2(C)L6](BF4)4, where L=2-(diphenylphosphino)-5- methylpyridine, are distinguished in the respective mass spectrum, accompanied by some fragment ion peaks. In addition, the mass-to-charge ratios of the parent ions are determi- nated. Preliminary results suggest that the device is a powerful tool for the study of metal cluster compounds. It turns out that the information obtained by the instrumentation serves as an essential supplement to single crystal X-ray diffraction for structure characterization of metal cluster compounds. 展开更多
关键词 Nano-electrospray ionization source Ion transmission and focus system Reflectron time-of-flight mass spectrometer Metal cluster compounds Single crystal x-ray diffraction
下载PDF
Mineralogical study of surface sediments in the western Arctic Ocean and their implications for material sources 被引量:2
17
作者 DONG Linsen SHI Xuefa +5 位作者 LIU Yanguang FANG Xisheng CHEN Zhihua WANG Chunjuan ZOU Jianjun HUANG Yuanhui 《Advances in Polar Science》 2014年第3期192-203,共12页
Mineralogical analysis was performed on bulk sediments of 79 surface samples using X-ray diffraction. The analytical results, combined with data on ocean currents and the regional geological background, were used to i... Mineralogical analysis was performed on bulk sediments of 79 surface samples using X-ray diffraction. The analytical results, combined with data on ocean currents and the regional geological background, were used to investigate the mineral sources. Mineral assemblages in sediments and their distribution in the study area indicate that the material sources are complex. (1) Feldspar is abundant in the sediments of the middle Chukchi Sea near the Bering Strait, originating from sediments in the Anadyr River carried by the Anadyr Current. Sediments deposited on the western side of the Chukchi Sea are rich in feldspar. Compared with other areas, sediments in this region are rich in hornblende transported from volcanic and sedimentary rocks in Siberia by the Anadyr Stream and the Siberian Coastal Current. Sediments in the eastern Chukchi Sea are rich in quartz sourced from sediments of the Yukon and Kuskokwim rivers carried by the Alaska Coastal Current. Sediments in the northern Chukchi Sea are rich in quartz and carbonates from the Mackenzie River sediments. (2) Sediments of the southern and central Canada Basin contain little calcite and dolomite, mainly due to the small impact of the Beaufort Gyre carrying carbonates from the Canadian Arctic Islands. Compared with other areas, the mica content in the region is high, implying that the Laptev Sea is the main sediment source for the southern and central Canada Basin. In the other deep sea areas, calcite and dolomite levels are high caused by the input of large amounts of sediment carried by the Beaufort Gyre from the Canadian Arctic Islands (Banks and Victoria). The Siberian Laptev Sea also provides small amounts of sediment for this region. Furthermore, the Atlantic mid-water contributes some fine-grained material to the entire deep western Arctic Ocean. 展开更多
关键词 x-ray diffraction western Arctic Ocean MINERALS surface sediments sourceS
下载PDF
X-Ray from Laser Produced Plasma as an Excitation Source in Spectroscopy Study
18
作者 周赤 王骐 +1 位作者 李思宁 马祖光 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1994年第2期71-74,共4页
Spectral and temporal characteristics of soft X-ray from the laser-produced plasma (LPX)were studied under different conditions.The obtained LPX spectrum showed a little different from the black-body distribution in s... Spectral and temporal characteristics of soft X-ray from the laser-produced plasma (LPX)were studied under different conditions.The obtained LPX spectrum showed a little different from the black-body distribution in some other references,which is analysed theoretically.It is shown that LPX can be used as a convenient exciting method in spectroscopy study. 展开更多
关键词 ss:Laser PLASMA PUMPING source x-ray
下载PDF
High-brightness photo-injector with standing-wave buncher-based ballistic bunching scheme for inverse Compton scattering light source
19
作者 Jian-Xin Wang Kui Zhou +7 位作者 Peng Li De-Xin Xiao Li-Jun Shan Xu-Ming Shen Yu Liu Zheng Zhou Han-Bin Wang Dai Wu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第4期51-61,共11页
We report our recent progress in the design and simulation of a high-brightness S-band photo-injector with a ballistic bunching scheme aimed at driving an inverse Compton scattering(ICS)X-ray source.By adding a short ... We report our recent progress in the design and simulation of a high-brightness S-band photo-injector with a ballistic bunching scheme aimed at driving an inverse Compton scattering(ICS)X-ray source.By adding a short standing-wave buncher between the RF gun and first booster in a conventional S-band photo-injector,electron bunches with a 500 pC charge can be compressed to the sub-picosecond level with very limited input RF power and an unchanged basic layout of the photo-injector.Beam dynamics analysis indicates that fine tuning of the focusing strength of the gun and linac solenoid can well balance additional focusing provided by the standing wave buncher and generate a well-compensated transverse emittance.Thorough bunching dynamics simulations with different operating conditions of the buncher show that a buncher with more cells and a moderate gradient is suitable for simultaneously obtaining a short bunch duration and low emittance.In a typical case of a 9-cell buncher with a 38 MV/m gradient,an ultrashort bunch duration of 0.5 ps(corresponding to a compression ratio of>5)and a low emittance of<1 mm mrad can be readily obtained for a 500 pC electron pulse.This feasible ballistic bunching scheme will facilitate the implementation of an ultrashort pulse mode inverse Compton scattering X-ray source on most existing S-band photo-injectors. 展开更多
关键词 Beam brightness Ballistic bunching Emittance compensation Compton scattering x-ray source
下载PDF
Continued Study on Hohlraum Radiation Source with Approximately Constant Radiation Temperature
20
作者 宋天明 杨家敏 +2 位作者 朱托 李志超 黄成武 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第4期342-345,共4页
An experiment was performed on the Shenguang III prototype laser facility to continue the study on hohlraum radiation source with approximately constant radiation temperature using a continuously shaped laser pulse.A ... An experiment was performed on the Shenguang III prototype laser facility to continue the study on hohlraum radiation source with approximately constant radiation temperature using a continuously shaped laser pulse.A radiation source with a flattop temperature of about130 e V that lasted about 5 ns was obtained.The previous analytical iteration method based on power balance and self-similar solution of ablation was modified taking into account the plasma movements and it was used to design the laser pulse shape for experiment.A comparison between experimental results and simulation is presented and better agreement was achieved using the modified method.Further improvements are discussed. 展开更多
关键词 x-ray radiation source laser pulse shaping power balance
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部