期刊文献+
共找到521篇文章
< 1 2 27 >
每页显示 20 50 100
A synthetic diagnostics platform for microwave imaging diagnostics in tokamaks
1
作者 李子涵 杨尚川 +5 位作者 徐新航 张立夫 渠承明 李诚普 庄革 谢锦林 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期38-45,共8页
Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has bee... Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has been established that facilitates microwave imaging reflectometry and electron cyclotron emission imaging.This platform utilizes plasma profiles as input and incorporates the finite-difference time domain,ray tracing and the radiative transfer equation to calculate the propagation of plasma spontaneous radiation and the external electromagnetic field in plasmas.Benchmark tests for classical cases have been conducted to verify the accuracy of every core module in the GSD platform.Finally,2D imaging of a typical electron temperature distribution is reproduced by this platform and the results are consistent with the given real experimental data.This platform also has the potential to be extended to 3D electromagnetic field simulations and other microwave diagnostics such as cross-polarization scattering. 展开更多
关键词 synthetic diagnostics tokamak plasmas microwave imaging diagnostics microwave imaging reflectometer electron cyclotron emission imaging
下载PDF
Microwave-induced thermoacoustic imaging with functional nanoparticles
2
作者 Xiaoyu Tang Jia Fu Huan Qin 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS CSCD 2023年第2期92-107,共16页
As an emerging hybrid imaging modality,microwave-induced thermoacoustic imaging(MTAI),using microwaves as the excitation source and ultrasonic signals as the information carrier for combining the characteristics of hi... As an emerging hybrid imaging modality,microwave-induced thermoacoustic imaging(MTAI),using microwaves as the excitation source and ultrasonic signals as the information carrier for combining the characteristics of high contrast of electromagnetic imaging and high resolution of ultrasound imaging,has shown broad prospects in biomedical and clinical applications.The imaging contrast depends on the microwave-absorption coe±cient of the endogenous imaged tissue and the injected MTAI contrast agents.With systemically introduced functional nanoparticles,MTAI contrast and sensitivity can be further improved,and enables visualization of biological processes in vivo.In recent years,functional nanoparticles for MTAI have been developed to improve the performance and application range of MTAI in biomedical applications.This paper reviews the recent progress of functional nanoparticles for MTAI and their biomedical applications.The challenges and future directions of microwave thermoacoustic imaging with functional nanoparticles in theeld of translational medicine are discussed. 展开更多
关键词 microwave thermoacoustic imaging NANOMATERIALS NANOPROBE
下载PDF
Prospects of microwave-induced thermoacoustic imaging
3
作者 Xing-Hua Wang Huan Qin 《Journal of Electronic Science and Technology》 EI CAS CSCD 2023年第3期21-37,共17页
Microwave-induced thermoacoustic imaging(MTAI)has advantages including the large imaging depth,high imaging resolution,high imaging contrast,and fast imaging speed.The thermoacoustic(TA)group of South China Normal Uni... Microwave-induced thermoacoustic imaging(MTAI)has advantages including the large imaging depth,high imaging resolution,high imaging contrast,and fast imaging speed.The thermoacoustic(TA)group of South China Normal University has dedicated to developing TA imaging for more than a decade and has made many breakthroughs.This review introduces these breakthroughs from two aspects including the improvement in techniques and the exploration of applications.On the technological level,there are ultrashort microwave pulse(USMP)-inducedTA imaging that can improve the imaging resolution,nonlinear thermoacoustic imaging(NTAI)that can improve the imaging contrast,polarized microwave-inducedthermoacoustic imaging(P-MTAI)that can obtain cellular-level alignment information,and more convenient and accurate handheld and multimodal probes.On the application side,the optimization and expansion have been carried out,mainly concentrating on breast and myocardial imaging.Finally,several current research directions are introduced,including the application of P-MTAI on joint imaging and research on whole-body imaging of small animals. 展开更多
关键词 Applications in biomedical field microwave-induced thermoacoustic imaging(MTAI) Nonlinear thermoacoustic imaging(NTAI) Polarized microwave-induced thermoacoustic imaging(P-MTAI) Ultrashort microwave pulse (USMP)-induced thermoacoustic imagING
下载PDF
Zero-Index Metamaterial Superstrates UWB Antenna for Microwave Imaging Detection
4
作者 Mohd Aminudin Jamlos Nur Amirah Othman +2 位作者 Wan Azani Mustafa Mohd Faizal Jamlos Mohamad Nur Khairul Hafizi Rohani 《Computers, Materials & Continua》 SCIE EI 2023年第4期277-292,共16页
Metamaterials(MTM)can enhance the properties of microwaves and also exceed some limitations of devices used in technical practice.Note that the antenna is the element for realizing a microwave imaging(MWI)system since... Metamaterials(MTM)can enhance the properties of microwaves and also exceed some limitations of devices used in technical practice.Note that the antenna is the element for realizing a microwave imaging(MWI)system since it is where signal transmission and absorption occur.Ultra-Wideband(UWB)antenna superstrates with MTM elements to ensure the signal transmitted from the antenna reaches the tumor and is absorbed by the same antenna.The lack of conventional head imaging techniques,for instance,Magnetic Resonance Imaging(MRI)and Computerized Tomography(CT)-scan,has been demonstrated in the paper focusing on the point of failure of these techniques for prompt diagnosis and portable systems.Furthermore,the importance ofMWIhas been addressed elaborately to portray its effectiveness and aptness for a primary tumor diagnosis.Other than that,MTM element designs have been discussed thoroughly based on their performances towards the contributions to the better image resolution of MWI with detailed reasonings.This paper proposes the novel design of a Zeroindex Split RingResonator(SRR)MTMelement superstrate with a UWB antenna implemented in MWI systems for detecting tumor.The novel design of the MTM enables the realization of a high gain of a superstrate UWB antenna with the highest gain of 5.70 dB.Besides that,the MTM imitates the conduct of the zeroreflection phase on the resonance frequency,which does not exist.An antenna with an MTM unit is of a 7×4 and 10×5 Zero-index SRR MTM element that acts as a superstrate plane to the antenna.Apart from that,Rogers(RT5880)substrate material is employed to fabricate the designed MTM unit cell,with the following characteristics:0.51mm thickness,the loss tangent of 0.02,as well as the relative permittivity of 2.2,with Computer Simulation Technology(CST)performing the simulation and design.Both MTM unit cells of 7×4 and 10×5 attained 0°with respect to the reflection phase at the 2.70 GHz frequency band.The first design,MTM Antenna Design 1,consists of a 7×4 MTM unit cell that observed a rise of 5.70 dB with a return loss(S11)−20.007 dB at 2.70 GHz frequency.The second design,MTM Antenna Design 2,consists of 10×5 MTM unit cells that recorded a gain of 5.66 dB,having the return loss(S11)−19.734 dB at 2.70 GHz frequency.Comparing these two MTM elements superstrates with the antenna,one can notice that the 7×4 MTM element shape has a low number of the unit cell with high gain and is a better choice than the 10×5 MTM element in realizing MTM element superstrates antenna for MWI. 展开更多
关键词 Zero-index metamaterial(ZIM) ultra-wideband(UWB) microwave imaging(MWI)detection
下载PDF
Assimilation of GPM Microwave Imager Radiance for Track Prediction of Typhoon Cases with the WRF Hybrid En3DVAR System 被引量:1
5
作者 Dongmei XU Feifei SHEN +1 位作者 Jinzhong MIN Aiqing SHU 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2021年第6期983-993,共11页
The impact of assimilating radiance data from the advanced satellite sensor GMI(GPM microwave imager)for typhoon analyses and forecasts was investigated using both a three-dimensional variational(3DVAR)and a hybrid en... The impact of assimilating radiance data from the advanced satellite sensor GMI(GPM microwave imager)for typhoon analyses and forecasts was investigated using both a three-dimensional variational(3DVAR)and a hybrid ensemble-3DVAR method.The interface of assimilating the radiance for the sensor GMI was established in the Weather Research and Forecasting(WRF)model.The GMI radiance data are assimilated for Typhoon Matmo(2014),Typhoon Chan-hom(2015),Typhoon Meranti(2016),and Typhoon Mangkhut(2018)in the Pacific before their landing.The results show that after assimilating the GMI radiance data under clear sky condition with the 3DVAR method,the wind,temperature,and humidity fields are effectively adjusted,leading to improved forecast skills of the typhoon track with GMI radiance assimilation.The hybrid DA method is able to further adjust the location of the typhoon systematically.The improvement of the track forecast is even more obvious for later forecast periods.In addition,water vapor and hydrometeors are enhanced to some extent,especially with the hybrid method. 展开更多
关键词 WRF model GMI microwave imager data TYPHOON data assimilation
下载PDF
A review of microwave-induced thermoacoustic imaging:Excitation source,data acquisition system and biomedical applications 被引量:3
6
作者 Yongsheng Cui Chang Yuan Zhong Ji 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2017年第4期52-69,共18页
Microwave-induced thermoacoustic imaging(TAI)is a noninvasive modality based on the differences in microwave absorption of various biological tissues.TAI has been extensively researched in recent years,and several stu... Microwave-induced thermoacoustic imaging(TAI)is a noninvasive modality based on the differences in microwave absorption of various biological tissues.TAI has been extensively researched in recent years,and several studies have revealed that TAI possesses advantages such as high resolution,high contrast,high imaging depth and fast imaging speed.In this paper,we reviewed the development of the TAI technique,its excitation source,data acquisition system and biomedical applications.It is believed that TAI has great potential applications in biomedical research and clinical study. 展开更多
关键词 Thermoacoustic imaging microwave biomedical applications
下载PDF
Directional Wideband Wearable Antenna with Circular Parasitic Element for Microwave Imaging Applications 被引量:2
7
作者 N.A.Koma’rudin Z.Zakaria +5 位作者 A.A.Althuwayb H.Lago H.Alsariera H.Nornikman A.J.A.Al-Gburi P.J.Soh 《Computers, Materials & Continua》 SCIE EI 2022年第7期983-998,共16页
This work proposes a wideband and unidirectional antenna consisting of dual layer of coplanar waveguide based on the circular parasitic element technique.The design procedure is implemented in three stages:Design A,wh... This work proposes a wideband and unidirectional antenna consisting of dual layer of coplanar waveguide based on the circular parasitic element technique.The design procedure is implemented in three stages:Design A,which operates at 3.94 GHz with a bandwidth of 3.83 GHz and a fractional bandwidth(FBW)of 97.2%;Design B,which operates at 3.98 GHz with a bandwidth of 0.66 GHz(FBW of 56.53%);and Design C as the final antenna.The final Design C is designed to resonate at several frequencies between 2.89 and 7.0 GHz for microwave imaging applications with a bandwidth of 4.11 GHz(79.8%)centered at 5.15 GHz.This antenna is fabricated fully using two textile materials:felt as the substrate and ShieldIt as the conductor.It features a unidirectional radiation with a gain of 5.5 dBi,and reduced lowback radiation from 2.06 to−7.81 dB.The front-to-back ratio(FBR)for Design A,Design B and Design C are 4.82,2.94 and 11.36 dB,respectively.This antenna is wideband with unidirectional radiation,lightweight,and flexible. 展开更多
关键词 Wearable antennas ultrawideband antennas unidirectional antennas microwave imaging
下载PDF
A Comparative Study of Automated Segmentation Methods for Use in a Microwave Tomography System for Imaging Intracerebral Hemorrhage in Stroke Patients 被引量:2
8
作者 Qaiser Mahmood Shaochuan Li +4 位作者 Andreas Fhager Stefan Candefjord Artur Chodorowski Andrew Mehnert Mikael Persson 《Journal of Electromagnetic Analysis and Applications》 2015年第5期152-167,共16页
Microwave technology offers the possibility for pre-hospital stroke detection as we have previously demonstrated using non-imaging diagnostics. The focus in this paper is on image-based diagnostics wherein the technic... Microwave technology offers the possibility for pre-hospital stroke detection as we have previously demonstrated using non-imaging diagnostics. The focus in this paper is on image-based diagnostics wherein the technical and computational complexities of image reconstruction are a challenge for clinical realization. Herein we investigate whether information about a patient’s brain anatomy obtained prior to a stroke event can be used to facilitate image-based stroke diagnostics. A priori information can be obtained by segmenting the patient’s head tissues from magnetic resonance images. Expert manual segmentation is presently the gold standard, but it is laborious and subjective. A fully automatic method is thus desirable. This paper presents an evaluation of several such methods using both synthetic magnetic resonance imaging (MRI) data and real data from four healthy subjects. The segmentation was performed on the full 3D MRI data, whereas the electromagnetic evaluation was performed using a 2D slice. The methods were evaluated in terms of: i) tissue classification accuracy over all tissues with respect to ground truth, ii) the accuracy of the simulated electromagnetic wave propagation through the head, and iii) the accuracy of the image reconstruction of the hemorrhage. The segmentation accuracy was measured in terms of the degree of overlap (Dice score) with the ground truth. The electromagnetic simulation accuracy was measured in terms of signal deviation relative to the simulation based on the ground truth. Finally, the image reconstruction accuracy was measured in terms of the Dice score, relative error of dielectric properties, and visual comparison between the true and reconstructed intracerebral hemorrhage. The results show that accurate segmentation of tissues (Dice score = 0.97) from the MRI data can lead to accurate image reconstruction (relative error = 0.24) for the intracerebral hemorrhage in the subject’s brain. They also suggest that accurate automated segmentation can be used as a surrogate for manual segmentation and can facilitate the rapid diagnosis of intracerebral hemorrhage in stroke patients using a microwave imaging system. 展开更多
关键词 Magnetic RESONANCE imagING Automatic Segmentation microwave DIELECTRIC Head Model INTRACEREBRAL HEMORRHAGE Reconstruction
下载PDF
Holographic microwave imaging for medical applications 被引量:1
9
作者 Lulu Wang Ray Simpkin A. M. Al-Jumaily 《Journal of Biomedical Science and Engineering》 2013年第8期823-833,共11页
This paper presents a new 2D holographic microwave imaging array (HMIA) technique for medical imaging applications. The HMIA technique has been applied to early stage breast cancer detection and brain stroke detection... This paper presents a new 2D holographic microwave imaging array (HMIA) technique for medical imaging applications. The HMIA technique has been applied to early stage breast cancer detection and brain stroke detection. Computer models are developed to demonstrate the feasibility of detecting and localizing small brain strokes within a 2D numerical head model and breast tumours within a 3D numerical breast model using the HMIA technique. Experimental validation of the HMIA simulation model using a breast phantom has been undertaken and demonstrated a good agreement between experimental and simulated images. Simulation and experimental results showed that the proposed HMIA technique has the potential to become a powerful medical screening and diagnostic tool. 展开更多
关键词 APERTURE Synthesis imagING BRAIN imagING BRAIN Stroke BREAST imagING BREAST Cancer microwave imagING HOLOGRAPHIC microwave imagING HOLOGRAPHIC microwave imagING Array
下载PDF
An Overview of Active Microwave Imaging for Early Breast Cancer Detection 被引量:4
10
作者 LIU Guang-dong ZHANG Ye-rong 《南京邮电大学学报(自然科学版)》 2010年第1期64-70,共7页
First,this article reviews the background of microwave imaging for early breast cancer detection,with a focus on active methods.Then active approaches,namely microwave tomography and radar-based microwave imaging,to m... First,this article reviews the background of microwave imaging for early breast cancer detection,with a focus on active methods.Then active approaches,namely microwave tomography and radar-based microwave imaging,to microwave breast cancer detection are overviewed briefly,where there are recent developments in imaging algorithms as well as antennas,models,phantom and experimental systems.Lastly,we give concluding remarks and future research.In a word,the main objective of this article is to provide an overview of the principles,development,and current research status of these approaches. 展开更多
关键词 雷达 信号处理系统 微波 电磁波
下载PDF
Design of tightly linked dual ring antenna and imaging of magnetic field distribution using a diamond fiber probe
11
作者 叶青云 薛雅文 +8 位作者 何飞越 赵旭彤 卞雨辰 卢文韬 王金旭 陈鸿浩 夏圣开 曾明菁 杜关祥 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期347-352,共6页
A tightly linked dual ring antenna is designed,and it is specifically tailored for uniformly coupling the microwave magnetic field to the nitrogen-vacancy(NV)center.The designed antenna operates at a center frequency ... A tightly linked dual ring antenna is designed,and it is specifically tailored for uniformly coupling the microwave magnetic field to the nitrogen-vacancy(NV)center.The designed antenna operates at a center frequency of about 2.87 GHz,with a bandwidth of around 200 MHz,allowing it to address multiple resonance peaks in the optically detected magnetic resonance(ODMR)spectrum in an external magnetic field.Moreover,the antenna generates a fairly uniform magnetic field in a range with a radius of 0.75 mm.High resolution imaging of the magnetic field distribution on the surface of the antenna is conducted by using a fiber diamond probe.We also investigate the effect of magnetic field uniformity on the linewidth of ODMR,so as to provide insights into reducing the inhomogeneous broadening of ODMR. 展开更多
关键词 nitrogen vacancy(NV) microwave(MW)imaging inhomogeneous broadening
下载PDF
Recent Advances in Short-Range Microwave Imaging in Europe
12
作者 Matteo Pastorino (Department of Biophysical and Electronic Engineering, University of Genova, Italy) 《Advances in Manufacturing》 SCIE CAS 1998年第1期4-17,共14页
This paper reports the content of a lecture presented at the 1995 International Conference and Exhibition on Electronic Measurement and Instrumentation, held in Shanghai, China in 1995. The paper presents(thanks to th... This paper reports the content of a lecture presented at the 1995 International Conference and Exhibition on Electronic Measurement and Instrumentation, held in Shanghai, China in 1995. The paper presents(thanks to the courtesy of several scientists) some of the most significant results recently obtained in the field of short range microwave imaging. The overview concerns the research activity carried out in Europe and is focused on microwave imaging for non destructive testing, civil engineering, and scientific and medical applications. This type of imaging is characterized by a relatively short distance between the object to be detected and the probes. 展开更多
关键词 microwave imaging inverse scattering spectrum domain method space domain method
下载PDF
Holographic Microwave Imaging Array for Brain Stroke Detection
13
作者 Lulu Wang A. M. Al-Jumaily Ray Simpkin 《Journal of Signal and Information Processing》 2013年第3期96-101,共6页
This paper proposes a new holographic microwave imaging array (HMIA) technique for brain stroke detection. This approach is based on holographic microwave and aperture synthesis imaging techniques. The system is desig... This paper proposes a new holographic microwave imaging array (HMIA) technique for brain stroke detection. This approach is based on holographic microwave and aperture synthesis imaging techniques. The system is designed for operation at a single frequency of 2.5 GHz. A realistic three dimensional (3D) head model that contains skin, fat, skull, cerebrospinal fluid (CSF), grey matter, white matter and ischemic or hemorrhagic stroke area is developed using MATLAB to demonstrate the proposed HMIA imaging algorithm.A matching solution medium is used between the antennas and the head model. The study is conducted using HMIA computer simulations and 3D head model with-stroke.The simulation results showed that small stroke area (5 mmin diameter) could be successfully detected with the HMIA approach. 展开更多
关键词 microwave imagING HOLOGRAPHIC microwave imagING ARRAY Aperture Synthesis imagING BRAIN imagING BRAIN STROKE
下载PDF
Near Field Microwave Holography for Bio-Tissue Imaging
14
作者 Yoshihiko Kuwahara Kimihito Fujii 《Open Journal of Medical Imaging》 2020年第3期143-150,共8页
This study investigated the ability of microwave holography to accurately reconstruct the tissue structure of the human body. Numerical breast and head phantoms were imaged by 3D near-field holography using backscatte... This study investigated the ability of microwave holography to accurately reconstruct the tissue structure of the human body. Numerical breast and head phantoms were imaged by 3D near-field holography using backscattered waves obtained by a monostatic planar scan. Complex organizational structures have been reconstructed accurately and quickly. In addition, breasts with relatively simple histology could be reconstructed without the matching liquid. 展开更多
关键词 microwave imaging Near Field Holography Bio-Tissue
下载PDF
Resolution Limits in Near-Distance Microwave Holographic Imaging for Safer and More Autonomous Vehicles
15
作者 Dmitry Leshchiner Konstantin Zvezdin +2 位作者 Grigory Chepkov Pietro Perlo Anatoly Popkov 《Journal of Traffic and Transportation Engineering》 2017年第6期316-327,共12页
下载PDF
Assessment and Assimilation of FY-3 Humidity Sounders and Imager in the UK Met Office Global Model 被引量:3
16
作者 Fabien CARMINATI Brett CANDY +1 位作者 William BELL Nigel ATKINSON 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2018年第8期46-58,共13页
China's FengYnn 3 (FY-3) polar orbiting satellites axe set to become an important sonrce of observational data for nu- merical weather prediction (NWP), atmospheric reanalyses, and climate monitoring studies over... China's FengYnn 3 (FY-3) polar orbiting satellites axe set to become an important sonrce of observational data for nu- merical weather prediction (NWP), atmospheric reanalyses, and climate monitoring studies over the next two decades. As part of the Climate Science for Service Partnership China (CSSP China) prograln, FY-3B Microwave Humidity Sounder 1 (MWHS-1) and FY-3C MWHS-2 observations have been thoroughly assessed and prepared for operational assimilation. This represents the first time observations from China's polar orbiting satellites have been used in the UK's global NWP model. Since 2016, continuous data quality monitoring has shown occasional bias changes found to be correlated to changes in the energy supply scheme regulating the platform heating system and other transient anomalies. Nonetheless, MWHS-1 and MWHS-2 significantly contribute to the 24-h forecast error reduction by 0.3% and 0.6%, respectively, and the combination of both instruments is shown to improve the fit to the model background of independent sounders by up to 1%. The observations from the Microwave Radiation Imager (MWRI) also are a potentially significant source of benefits for NWP models, but a solar-dependent bias observed in the instrument half-orbits has prevented their assimilation. This paper presents the bases of a correction scheme developed at the Met Office for the purpose of a future assimilation of MWRI data. 展开更多
关键词 microwave Humidity Sounder microwave Radiation imager numerical weather prediction
下载PDF
A TRUST REGION METHOD FOR MICROWAVE TOMOGRAPHY 被引量:1
17
作者 Gong Xing (Dept. of Biomedical Engineering, Zhejiang University, Hangzhou 310027) 《Journal of Electronics(China)》 2001年第2期181-184,共4页
A trust region method is proposed to solve the problem of microwave tomography,which is very difficult to be solved for its ill-posedness and nonlinearity. Compared with the Levenberg-Marquardt method, this method int... A trust region method is proposed to solve the problem of microwave tomography,which is very difficult to be solved for its ill-posedness and nonlinearity. Compared with the Levenberg-Marquardt method, this method introduces more a priori knowledge and might obtain better results, though the two methods are equal in some cases. 展开更多
关键词 microwave TOMOGRAPHY imagE RECONSTRUCTION TRUST REGION method
下载PDF
Large Scale Analysis of Complex Permittivity of Breast Cancer in Microwave Band 被引量:1
18
作者 Yoshihiko Kuwahara Akira Nozaki Kimihito Fujii 《Advances in Breast Cancer Research》 2020年第4期101-109,共9页
To obtain some prior knowledge of breast cancer detection by microwave imaging, we have measured and analyzed the complex permittivity of tissues extracted from over 140 breast cancer surgeries. The relative permittiv... To obtain some prior knowledge of breast cancer detection by microwave imaging, we have measured and analyzed the complex permittivity of tissues extracted from over 140 breast cancer surgeries. The relative permittivity and conductivity of tumor at 1.6 GHz were 17.5% and 16.2% higher than those of mammary gland tissue, respectively. In invasive ductal carcinoma of scirrhous type, 8 out of 64 had higher relative permittivity and conductivity of mammary gland than those of tumor. However, when evaluated by the Debye parameter considering the frequency dependence of the tissue, it is rare that </span><i><span style="font-family:Verdana;">ε</span></i><sub><span style="font-family:Verdana;">∞</span></sub><span style="font-family:Verdana;"> and Δ</span><i><span style="font-family:Verdana;">ε</span></i><span style="font-family:Verdana;"> of cancer are simultaneously lower than those of mammary gland. The relative permittivity and conductivity of fibroadenoma are almost the same as those of mammary glands. The relative permittivity and conductivity of each tissue showed strong linearity. Microwave imaging requires accurate reconstruction of </span><i><span style="font-family:Verdana;">ε</span></i><sub><span style="font-family:Verdana;">∞</span></sub><span style="font-family:Verdana;"> and Δ</span><i><span style="font-family:Verdana;">ε</span></i><span style="font-family:Verdana;"> to distinguish cancer from normal tissue. 展开更多
关键词 Breast Cancer Detection microwave imaging Complex Permittivity Debye Model
下载PDF
Simulation and Experimental Method for Microwave Oven 被引量:3
19
作者 Han-Ji Ju Qing Zhao 《Journal of Electronic Science and Technology of China》 2009年第2期188-191,共4页
The simulation software, HFSS (high frequency structure simulator), is introduced in microwave oven design. In the cold test, a network analyzer is used to measure the reflection coefficient (S11) of the cavity un... The simulation software, HFSS (high frequency structure simulator), is introduced in microwave oven design. In the cold test, a network analyzer is used to measure the reflection coefficient (S11) of the cavity under empty and loaded states over the frequency range from 2.448 GHz to 2.468 GHz. In the hot test, a piece of wet thermal paper and an infrared thermal imaging camera are used to measure the electric field distributions on the mica and turntable. In the cold test, the simulation agrees well with the experiment no matter in empty state or loaded state. In the hot test, the simulation agrees well with the experiment in general in empty state and approximately in loaded state. The little difference in both cold and hot test may be due to that the model in simulation is not absolutely identical with that in experiment or the inadequate precision of infrared thermal imaging camera. 展开更多
关键词 Index Terms-Far-infrared thermal imaging camera microwave oven simulation network analyzer wetthermal paper.
下载PDF
MICROWAVE SENSOR DEVELOPMENT IN RECENT TWO YEARS IN CHINA
20
作者 ZHANG Yunhua ZHANG Shengwei XU Ke JIANG Jingshan 《空间科学学报》 CAS CSCD 北大核心 2002年第z1期185-189,共5页
The development of microwave sensors in recent two years in China are in troduced with an emphasis on spaceborne sensors without the applications in cluded. The microwave sensors as the main payloads to be boarded on ... The development of microwave sensors in recent two years in China are in troduced with an emphasis on spaceborne sensors without the applications in cluded. The microwave sensors as the main payloads to be boarded on the future operational satellites, such as FY-3 meteorological satellites and HY-2 marine satellite are introduced with much in detail. Besides these, four new sensors are outlined, i.e. the imaging radar altimeter,synthetic aperture radiometer, and polarimetric radiometer. Two recently conducted flight experiment campaigns are also introduced with results shown. 展开更多
关键词 microwave Radiation imager (MWRI) microwave ATMOSPHERIC Temperature Sounder (MWTS) imaging Radar Altimeter Synthetic APERTURE Radiometer Polarimetric RADIOMETER
下载PDF
上一页 1 2 27 下一页 到第
使用帮助 返回顶部