Three kinds of coplanar waveguides (CPWs) are designed and fabricated on different silicon substrates---common low-resistivity silicon substrate (LRS), LRS with a 3μm-thick silicon oxide interlayer, and high-resi...Three kinds of coplanar waveguides (CPWs) are designed and fabricated on different silicon substrates---common low-resistivity silicon substrate (LRS), LRS with a 3μm-thick silicon oxide interlayer, and high-resistivity silicon (HRS) substrate. The results show that the microwave loss of a CPW on LRS is too high to be used, but it can be greatly reduced by adding a thick interlayer of silicon oxide between the CPW transmission lines and the LRS.A CPW directly on HRS shows a loss lower than 2dB/cm in the range of 0-26GHz and the process is simple,so HRS is a more suitable CPW substrate.展开更多
We present a study on radiation losses in the microwave X band in Al-Cr substituted Y-type hexaferrites, namely Ba2Mg2Alx/2Crx/2Fe12-xO22 (x = 0, 0.5 and 1.0). The study is performed by means of a vector network ana...We present a study on radiation losses in the microwave X band in Al-Cr substituted Y-type hexaferrites, namely Ba2Mg2Alx/2Crx/2Fe12-xO22 (x = 0, 0.5 and 1.0). The study is performed by means of a vector network analyzer, Fourier transform infrared spectroscopy, a vibrating sample magnetometer and x-ray powder diffraction. Ba2Mg2Fe12O22 hexaferrite shows radiation loss of -37.25dB (99.999% loss) at frequency 9.81 GHz, which can be attributed to its high value of saturation magnetization, i.e., 22.08emu/g. Moreover, we obtain that magnetic properties have strong influence on the radiation losses.展开更多
文摘Three kinds of coplanar waveguides (CPWs) are designed and fabricated on different silicon substrates---common low-resistivity silicon substrate (LRS), LRS with a 3μm-thick silicon oxide interlayer, and high-resistivity silicon (HRS) substrate. The results show that the microwave loss of a CPW on LRS is too high to be used, but it can be greatly reduced by adding a thick interlayer of silicon oxide between the CPW transmission lines and the LRS.A CPW directly on HRS shows a loss lower than 2dB/cm in the range of 0-26GHz and the process is simple,so HRS is a more suitable CPW substrate.
文摘We present a study on radiation losses in the microwave X band in Al-Cr substituted Y-type hexaferrites, namely Ba2Mg2Alx/2Crx/2Fe12-xO22 (x = 0, 0.5 and 1.0). The study is performed by means of a vector network analyzer, Fourier transform infrared spectroscopy, a vibrating sample magnetometer and x-ray powder diffraction. Ba2Mg2Fe12O22 hexaferrite shows radiation loss of -37.25dB (99.999% loss) at frequency 9.81 GHz, which can be attributed to its high value of saturation magnetization, i.e., 22.08emu/g. Moreover, we obtain that magnetic properties have strong influence on the radiation losses.