The clinical efficacy was compared between 3D navigation-assisted percutaneous iliosacral screw(3DPS)and minimally invasive reconstruction plate(MIRP)in treating sacroiliac complex injury and the surgical procedures o...The clinical efficacy was compared between 3D navigation-assisted percutaneous iliosacral screw(3DPS)and minimally invasive reconstruction plate(MIRP)in treating sacroiliac complex injury and the surgical procedures of 3DPS were introduced.A retrospective analysis was performed on 49 patients with sacroiliac complex injury from March 2013 to May 2017.Twenty-one cases were treated by 3DPS,and 28 cases by MIRP.Intraoperative indexes as operative time,blood loss,incision length,length of hospital stay and postoperative complications were respectively documented.Quality of reduction was postoperatively evaluated by Matta radiological criteria,and clinical effect was assessed by Majeed scoring criteria at the last followup.Operative time and hospital stay were significantly shortened,and blood loss,and incision length were significantly reduced in 3DPS group as compared with those in MIRP group(P<0.05).No statistically significant difference was found between 3DPS group and MIRP group in the assessment of reduction and function(P>0.05).It was concluded that both 3DPS and MIRP can effectively treat the sacroiliac complex injury,and 3DPS can provide an accurate,safe and minimally invasive fixation with shorter operative time and hospital stay.展开更多
Objective:To study the effects of MIPO and ORIF on stress degree and bone metabolism activity in patients with middle humeral shaft fractures.Methods: Patients with middle humeral shaft fractures who received surgical...Objective:To study the effects of MIPO and ORIF on stress degree and bone metabolism activity in patients with middle humeral shaft fractures.Methods: Patients with middle humeral shaft fractures who received surgical treatment in Mianyang Orthopedic Hospital between June 2010 and October 2015 were enrolled and randomly divided into MIPO group and ORIF group who were treated with minimally invasive plate oateosynthesis and open reduction internal fixation respectively. Before surgery as well as 1 d and 3 d after surgery, serum was collected to determine the contents of stress response molecules and bone metabolism markers.Results:1 d and 3 d after surgery, serum stress molecules PGE2, CRP, NE and E as well as bone resorption markers TRACP-5B,β-CTX, RANK and RANKL contents of both groups were higher than those before surgery while bone formation markers BGP, BALP, PINP and OPG contents were lower than those before surgery;serum stress molecules PGE2, CRP, NE and E as well as bone resorption markers TRACP-5B,β-CTX, RANK and RANKL contents of MIPO group were lower than those of ORFI group while bone formation markers BGP, BALP, PINP and OPG contents were higher than those of ORFI group.Conclusion: Compared with ORIF, MIPO for middle humeral shaft fractures can reduce stress response degree and improve bone metabolism.展开更多
Background Accurate and precise preoperative planning can provide information instrumental for performing less invasive articular fracture surgery. The purpose of this study was to determine that computer-assisted pre...Background Accurate and precise preoperative planning can provide information instrumental for performing less invasive articular fracture surgery. The purpose of this study was to determine that computer-assisted preoperative planning (CAPP) has the potential to improve efficiency and time in the operating room. Methods Sixty-four patients with proximal humeral fractures were treated using locking plates by minimally invasive plate osteosynthesis (MIPO) with CAPP. The time needed for virtual segmentation, reduction, and fixation of the fracture fragments were recorded. Intra and interobserver reliabilities were analyzed using the intraclass correlation coefficient. The clinical function was analyzed using Constant Score and radiology. Results The mean total time required for CAPP of two-part, three-part, and four-part proximal humeral fractures were (13.63±1.38) minutes, (23.14±2.18) minutes, and (39.61±3.01) minutes, respectively. The intra and interobserver reliabilities for all variables were high, ranging from 0.785 to 0.992. The mean operation time was (50.1±6.7) minutes. Fifty- two patients were followed up with an average time of 34.2 months. The mean Constant Score of the injury side was (82.5 ± 9.9). Three of the fifty-two patients had four complications. Conclusion The application of CAPP was efficient and reliable, and provided excellent clinical and radiographic outcomes for the treatment of proximal humerus fractures by MIPO.展开更多
文摘The clinical efficacy was compared between 3D navigation-assisted percutaneous iliosacral screw(3DPS)and minimally invasive reconstruction plate(MIRP)in treating sacroiliac complex injury and the surgical procedures of 3DPS were introduced.A retrospective analysis was performed on 49 patients with sacroiliac complex injury from March 2013 to May 2017.Twenty-one cases were treated by 3DPS,and 28 cases by MIRP.Intraoperative indexes as operative time,blood loss,incision length,length of hospital stay and postoperative complications were respectively documented.Quality of reduction was postoperatively evaluated by Matta radiological criteria,and clinical effect was assessed by Majeed scoring criteria at the last followup.Operative time and hospital stay were significantly shortened,and blood loss,and incision length were significantly reduced in 3DPS group as compared with those in MIRP group(P<0.05).No statistically significant difference was found between 3DPS group and MIRP group in the assessment of reduction and function(P>0.05).It was concluded that both 3DPS and MIRP can effectively treat the sacroiliac complex injury,and 3DPS can provide an accurate,safe and minimally invasive fixation with shorter operative time and hospital stay.
文摘Objective:To study the effects of MIPO and ORIF on stress degree and bone metabolism activity in patients with middle humeral shaft fractures.Methods: Patients with middle humeral shaft fractures who received surgical treatment in Mianyang Orthopedic Hospital between June 2010 and October 2015 were enrolled and randomly divided into MIPO group and ORIF group who were treated with minimally invasive plate oateosynthesis and open reduction internal fixation respectively. Before surgery as well as 1 d and 3 d after surgery, serum was collected to determine the contents of stress response molecules and bone metabolism markers.Results:1 d and 3 d after surgery, serum stress molecules PGE2, CRP, NE and E as well as bone resorption markers TRACP-5B,β-CTX, RANK and RANKL contents of both groups were higher than those before surgery while bone formation markers BGP, BALP, PINP and OPG contents were lower than those before surgery;serum stress molecules PGE2, CRP, NE and E as well as bone resorption markers TRACP-5B,β-CTX, RANK and RANKL contents of MIPO group were lower than those of ORFI group while bone formation markers BGP, BALP, PINP and OPG contents were higher than those of ORFI group.Conclusion: Compared with ORIF, MIPO for middle humeral shaft fractures can reduce stress response degree and improve bone metabolism.
文摘Background Accurate and precise preoperative planning can provide information instrumental for performing less invasive articular fracture surgery. The purpose of this study was to determine that computer-assisted preoperative planning (CAPP) has the potential to improve efficiency and time in the operating room. Methods Sixty-four patients with proximal humeral fractures were treated using locking plates by minimally invasive plate osteosynthesis (MIPO) with CAPP. The time needed for virtual segmentation, reduction, and fixation of the fracture fragments were recorded. Intra and interobserver reliabilities were analyzed using the intraclass correlation coefficient. The clinical function was analyzed using Constant Score and radiology. Results The mean total time required for CAPP of two-part, three-part, and four-part proximal humeral fractures were (13.63±1.38) minutes, (23.14±2.18) minutes, and (39.61±3.01) minutes, respectively. The intra and interobserver reliabilities for all variables were high, ranging from 0.785 to 0.992. The mean operation time was (50.1±6.7) minutes. Fifty- two patients were followed up with an average time of 34.2 months. The mean Constant Score of the injury side was (82.5 ± 9.9). Three of the fifty-two patients had four complications. Conclusion The application of CAPP was efficient and reliable, and provided excellent clinical and radiographic outcomes for the treatment of proximal humerus fractures by MIPO.