期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Clues for diagnosing misplaced central venous catheter in the right ascending lumbar vein during right femoral venous access
1
作者 Joho Tokumine Kiyoshi Moriyama Tomoko Yorozu 《World Journal of Clinical Cases》 SCIE 2024年第24期5473-5475,共3页
The right ascending lumbar vein is difficult to detect on anteroposterior abdominalradiographs because it overlaps with the inferior vena cava on anteroposteriorradiographs.Intensive observation by medical providers m... The right ascending lumbar vein is difficult to detect on anteroposterior abdominalradiographs because it overlaps with the inferior vena cava on anteroposteriorradiographs.Intensive observation by medical providers may be a cue fordiagnosis.However,knowledge of catheter misplacement of the right ascendinglumbar vein is also necessary,because misplacement cannot be suspected withoutthat awareness. 展开更多
关键词 Central venous catheter Ascending lumbar vein Femoral vein Catheter misplacement Anteroposterior abdominal X-ray
下载PDF
The Nasogastric Tube in the Thorax after Gastric Pull Up!
2
作者 Puneet Khanna Rakesh Garg Amit Chirom Singh 《Open Journal of Anesthesiology》 2012年第2期36-37,共2页
Although nasogastric tube (NGT) is a simple procedure, the blind placement of nasogastric feeding tubes is not without risks. Chest radiogram is done to confirm the correct position of the NGT. We report a case where ... Although nasogastric tube (NGT) is a simple procedure, the blind placement of nasogastric feeding tubes is not without risks. Chest radiogram is done to confirm the correct position of the NGT. We report a case where radiography could not be confirmatory for the correct position of the tube in a specific group of patients. 展开更多
关键词 Nasogastric TUBE misplaced ESOPHAGECTOMY
下载PDF
Method with repeated extraction-insertion cycles to im prove the needle insertion accuracy
3
作者 张少华 金鑫 +2 位作者 张之敬 叶鑫 刘冰冰 《Journal of Beijing Institute of Technology》 EI CAS 2013年第3期324-329,共6页
In order to improve the effectiveness of percutaneous diagnosis and therapies, the needle insertion into the deforming soft and inhomogenous tissue should be accurate. In this study a needle with 6 degrees of freedom ... In order to improve the effectiveness of percutaneous diagnosis and therapies, the needle insertion into the deforming soft and inhomogenous tissue should be accurate. In this study a needle with 6 degrees of freedom force/torque sensor is used to find the relationship between the pathway's length and the force. Our experiments show that the method with repeated extraction-insertion cy- cles can make the needle approach the target as much as possible. Meanwhile a method to obtain the appropriaterepeated extraction-insertion cycles is given to drive the needle to execute the repeat- ed cycles efficiently. Experiments and discussions were conducted to preliminarily validate the meth- od. 展开更多
关键词 needle insertion soft tissue deformation misplacement elimination force feedback
下载PDF
Case Series: Nasogastric (NG) Feeding Tube Misplacement in Critically Ill Tracheostomized Patients
4
作者 Yoav Comay Elchanan Quint +4 位作者 Yoav Bichovsky Leonid Koyfman Anton Osyntsov Asaf Acker Evgeni Brotfain 《Case Reports in Clinical Medicine》 2020年第12期399-407,共9页
In this case series we present 3 cases of nasogastric tube misplacement in tracheostomy patients. Although considered safe and it being a common procedure nasogastric tube misplacement can lead to serious and life-thr... In this case series we present 3 cases of nasogastric tube misplacement in tracheostomy patients. Although considered safe and it being a common procedure nasogastric tube misplacement can lead to serious and life-threatening complications. We present three cases of nasogastric tube misplacement in tracheostomized patients. One of the cases presented suffered from pneumothorax. Different time intervals between procedures in these different cases resulted in similar results. We would like to emphasize the importance of due conformation of correct placement of the nasogastric tube in the tracheostomy patient as well as to suggest that over inflation of the balloon securing the tracheostomy apparatus in place during nasogastric tube placement, might prevent misplacement. Nasogastric tube placement in tracheostomized patients has potential for serious complications. As such maintaining safe practice procedure is essential. Considering over inflation of the tracheostomy apparatus balloon might be beneficial as well, by preventing entry of NGT into the trachea. 展开更多
关键词 Nasogastric Intubation Nasogastric Misplacement TRACHEOSTOMY Mechanically Ventilated
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部