期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Dosimetric evaluation of VMAT radiation therapy technique for breast cancer after conservative surgery based on three different types of multileaf collimators 被引量:5
1
作者 Fuli Zhang Weidong Xu +3 位作者 Huayong Jiang Yadi Wang Junmao Gao Qingzhi Liu 《Oncology and Translational Medicine》 2018年第5期208-214,共7页
Objective Radiotherapy combined with conservative surgery plays an important role in the treatment of early-stage breast cancer. Volumetric modulated arc therapy(VMAT) has been introduced into clinical practice. The p... Objective Radiotherapy combined with conservative surgery plays an important role in the treatment of early-stage breast cancer. Volumetric modulated arc therapy(VMAT) has been introduced into clinical practice. The purpose of this study was to investigate the dosimetric effects of different multileaf collimators(MLC) on VMAT radiotherapy plans for treating breast cancer.Methods Fifteen breast cancer patients who were treated using a conventional technique in our department were selected to participate in this retrospective analysis. VMAT plans based on three types of Elekta MLCs [Beam Modulator(BM) with 4-mm leaf width, Agility with 5-mm leaf width and MLCi2 with 10-mm leaf width] were independently generated for each patient. Plan comparisons were performed based on dose-volume histogram(DVH) analysis including dosimetric parameters such as the homogeneity index(HI), conformity index(CI), Dmax, Dmin, and Dmean for the planning treatment volume(PTV), in addition to dose-volume parameters for the organs at risk(OARs). The delivery efficiency of the three types of MLCs was compared in terms of the beam delivery time and the monitor units(MUs) per fraction for each plan. Results Both target uniformity and conformity were improved in plans for Agility and BM MLC compared with the plan using MLCi2. The mean HI decreased from 1.14 for MLCi2 to 1.13 for BM and 1.10 for Agility, while the mean CI increased from 0.68 for MLCi2 to 0.73 for BM and 0.75 for Agility. Furthermore, at both low and high dose levels, smaller volumes of ipsilateral lung, heart, contralateral lung, and breast were irradiated with Agility MLC than with the other two types of MLCs. The delivery time with Agility MLC was reduced by 10.8% and 32.1%, respectively, compared with that for MLCi2 and BM.Conclusion Our results indicate that the Agility MLC exhibits a dosimetric advantage and a significant improvement in delivery efficiency for the treatment of breast cancer using VMAT. 展开更多
关键词 放射治疗 癌病 类型 外科 保守 技术 评估
下载PDF
Agility光栅系统在眼眶淋巴瘤放疗剂量学研究 被引量:1
2
作者 石慧烽 涂文勇 +2 位作者 胡海生 樊文慧 窦圣金 《中华肿瘤防治杂志》 CAS 北大核心 2019年第8期573-577,共5页
目的眼眶淋巴瘤靶区空间位置比较特殊,提高眼眶淋巴瘤计划的质量,保护眼睛是医生和物理师关注的焦点。本研究旨在探讨Agility光栅系统在眼眶淋巴瘤中的剂量学特点。方法选取2016-05-01-2018-05-30上海交通大学医学院附属第九人民医院放... 目的眼眶淋巴瘤靶区空间位置比较特殊,提高眼眶淋巴瘤计划的质量,保护眼睛是医生和物理师关注的焦点。本研究旨在探讨Agility光栅系统在眼眶淋巴瘤中的剂量学特点。方法选取2016-05-01-2018-05-30上海交通大学医学院附属第九人民医院放疗的10例眼眶淋巴瘤患者,选用monaco计划系统进行计算,光栅数据分别选择Mlci2和Agility,照射方式采用动态调强。计算时,固定其他组织的限量,仅改变患者患侧晶体的限量,限量范围从4~20Gy进行变化,函数采用Serial,每次变化为2Gy,根据计算结果,分别对眼睛整体、晶体、视神经、靶区的适形性指数(conformal index,CI)、均匀性指数(homogeneity idex,HI)以及计划跳数进行统计分析。结果随着患侧晶体限量增加,在CI、HI、患侧视神经、患侧晶体平均量、患侧眼睛平均量、计划跳数参数上,Agility更具优势,CI差别率从27.12%降到5.11%,HI差别率从11.52%降到1.57%,下降趋势逐渐变缓,差异有统计学意义,P<0.01;患侧视神经差别率从11.99%下降到1.53%,差异有统计学意义,P<0.01;患侧晶体平均值差别率从20.59%下降到3.55%,差异有统计学意义,P<0.01;患侧眼睛平均值在晶体限量低于10Gy时,差异有统计学意义,P<0.05;高于14Gy,差异无统计学意义。对侧晶体的计算结果,Mlci2更具优势。结论眼眶淋巴瘤放疗时,Agility光栅的计算结果比Mlci2光栅更具有剂量学优势,眼眶淋巴瘤的放疗应采用Agility光栅。 展开更多
关键词 mlci2 AGILITY 光栅 monaco治疗计划系统 眼眶淋巴瘤
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部