期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Application of Modified Silica Coated Magnetite Nanoparticles for Removal of Iodine from Water Samples 被引量:6
1
作者 Tayyebeh Madrakian Abbas Afkhami +2 位作者 Mohammad Ali Zolfigol Mazaher Ahmadi Nadia Koukabi 《Nano-Micro Letters》 SCIE EI CAS 2012年第1期57-63,共7页
The adsorption of iodine onto silica coated magnetite nanoparticles(im-SCMNPs) that modified with imidazole was investigated for removal of high concentrations of iodine from wastewater. Modified silica magnetite nano... The adsorption of iodine onto silica coated magnetite nanoparticles(im-SCMNPs) that modified with imidazole was investigated for removal of high concentrations of iodine from wastewater. Modified silica magnetite nanoparticles showed high efficiency in removing iodine from wastewater samples. The optimum pH for iodine removal was 7.0-8.0. The adsorption capacity was evaluated using both the Langmuir and Freundlich adsorption isotherm models. The size of the produced magnetite nanoparticles was determined by X-ray diffraction analysis and scanning electron microscopy. Synthesized magnetite nanoparticles showed the high adsorption capacity and would be a good method to increase adsorption efficiency for the removal of iodine in a wastewater treatment process. The Langmuir adsorption capacity(qmax) was found to be 140.84 mg/g of the adsorbent. 展开更多
关键词 modified silica magnetite nanoparticles IODINE IMIDAZOLE Water samples
下载PDF
A Gas Chromatographic Analysis of Light Hydrocarbons on a Column Packed with Modified Silica Gel
2
《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第11期1019-1022,共4页
关键词 LI A Gas Chromatographic Analysis of Light Hydrocarbons on a Column Packed with modified silica Gel
下载PDF
Highly Efficient Heavy-Metal-Ion Removal from Shellfish Processing Liquid with Low Protein and Polysaccharide Loss by Hybrid Mesoporous Silica Diol-APDC-SBA15 被引量:1
3
作者 QI Yanxia SONG Yang +4 位作者 LIU Chang QI Shizhe WANG Haibo CAO Jijuan ZHAO Qiancheng 《Journal of Ocean University of China》 SCIE CAS CSCD 2023年第1期221-228,共8页
Heavy metal ions in shellfish products are harmful to human health,and their removal with low nutrient loss remains challenging.Herein,a new type of mesoporous silica(SBA15),modified internally with ammonium pyrrolidi... Heavy metal ions in shellfish products are harmful to human health,and their removal with low nutrient loss remains challenging.Herein,a new type of mesoporous silica(SBA15),modified internally with ammonium pyrrolidine dithiocarbamate(APDC)and externally with alkyl-diol groups,which was named as Diol-APDC-SBA15,was successfully developed and characterized by powder X-ray diffraction patterns,nitrogen adsorption,and Fourier transform infrared spectroscopy.The solutions with lead,chromium,cadmium,and copper were used to investigate the adsorption capacity of Diol-APDC-SBA15.Diol-APDC-SBA15 was adopted to remove heavy metals from cooking liquids of clams(Ruditapes philippinarum),hydrolysate liquids of oysters(Ostrea gigas Thunberg),and polysaccharide solution from the cooking liquid of R.philippinarum.The efficiencies of removing heavy metal ions and the loss rates of proteins and polysaccharides were examined.The results showed that the adsorption capacities of Diol-APDCSBA15 for Pb,Cr,Cd,and Cu in standard heavy-metal solutions were 161.4,166.1,29.6,and 60.2mgg^(−1),respectively.The removal efficiency of Diol-APDC-SBA15 for Pb in the three shellfish processing liquids ranged from 60.5%to 99.6%.The Cr removal efficiency was above 99.9%in the oyster hydrolysate liquid.Meanwhile,the percentages of polysaccharide loss were 5.5%and 3.7%in the cooking liquid of clam and polysaccharide solution,respectively,and the protein loss was 1.2%in the oyster hydrolysate liquid.Therefore,the Diol-APDC-SBA15 material exhibits a great potential application in the removal of heavy metals from shellfish processing liquids with low losses of proteins and polysaccharides. 展开更多
关键词 heavy-metal removal modified mesoporous silica shellfish processing liquid protein POLYSACCHARIDE
下载PDF
Microstructure and Mechanical Properties of Poly (Vinyl Chloride) Modified by Silica Fume /Acrylic Core-Shell Impact Modifier Blends 被引量:1
4
作者 黄健 马保国 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2012年第5期886-891,共6页
This research explored replacing acrylic core-shell impact modifier (AIM) by silica fume to toughen PVC. 100%, 75%, 50% and 25% of AIM (8 phr) were substituted by silica fume in PVC respectively, and then processe... This research explored replacing acrylic core-shell impact modifier (AIM) by silica fume to toughen PVC. 100%, 75%, 50% and 25% of AIM (8 phr) were substituted by silica fume in PVC respectively, and then processed by dry blending and twin-screw extrusion. Severe silica fume agglomeration was observed by scanning electron microscope (SEM) in the PVC matrix when 8 phr pure silica fume was used and processed by screw speed of 20 rpm. Its tensile strength was thereby reduced by 38% comparing to unmodified PVC. The silica fume was successfully dispersed while the screw speed was slowed down to 10 rpm to give a stronger screw torque and a longer melt residential time in the extruder. The tensile strength was ’recovered’ to a level comparable to unmodified PVC. Impact test were performed on all formulations extruded at 10 rpm screw speed and synergetic toughening effect was found with 50% substitution and it had the impact strength that was comparable to 8 phr pure AIM toughened PVC. 展开更多
关键词 silica fume acrylic impact modifier synergetic effect poly (vinyl chloride) tensile strength impact modification twin screw extrusion
下载PDF
Evaluation of Average Wall Thickness of Organically Modified Mesoporous Silica
5
作者 YanJunGONG ZhiHongLI BaoZhongDONG 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第1期139-142,共4页
The small angle X-ray scattering of organically modified MSU-X silica prepared by co-condensation of tetraethoxysilane (TEOS) and methyltriethoxysilane (MTES) show negative deviation from Debye’s theory due to the ... The small angle X-ray scattering of organically modified MSU-X silica prepared by co-condensation of tetraethoxysilane (TEOS) and methyltriethoxysilane (MTES) show negative deviation from Debye’s theory due to the existence of the organic interface layer. By exerting correction of the scattering negative deviation, Debye relation may be recovered, and the average wall thickness of the material may be evaluated. 展开更多
关键词 Organically modified mesoporous silica average wall thickness small angle X-ray scattering (SAXS).
下载PDF
STUDY ON ENRICHMENT AND SEPARATION OF TRACE ELEMENTS WITH SILICA GELS MODIFIED BY HETEROCYCLIC AZO DYES
6
作者 Ke An LI~2, Feng LIU, Shen Yang TONG (Department of Chemistry, Peking University, Beijing 100871) 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第8期633-636,共4页
Two types of modified silica gels were prepared by adsorption method and bonding method respectively. Enrichment and separation of trace metal ions have been done by using the column packed with modified silica gels.
关键词 HCI Br SG STUDY ON ENRICHMENT AND SEPARATION OF TRACE ELEMENTS WITH silica GELS modified BY HETEROCYCLIC AZO DYES AZO TAH
下载PDF
Electrochemical Behavior of Magnolol on FeWO4 Nanoflower Modified Carbon Paste Electrode
7
作者 胡卫兵 ZHANG Wen +2 位作者 SONG Nannan QU Wanyun HU Sheng 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2016年第4期722-726,共5页
In order to establish a simple,sensitive,and fast reliable detection method to determine the magnolol,FeWO4 nanoflower was synthesised through a solvothermal technique and FeWO4 nanoflower modified carbon paste electr... In order to establish a simple,sensitive,and fast reliable detection method to determine the magnolol,FeWO4 nanoflower was synthesised through a solvothermal technique and FeWO4 nanoflower modified carbon paste electrode(CPE) was developed.The voltammetric behavior of magnolol on the modified electrodes was studied using cyclic voltammetry(CV),linear sweep voltammetry(LSV),and differential pulse voltammetry(DPV).The experimental results showed that the modified electrode remarkably enhanced the electrochemical response of the magnolol and exhibited a wide linear range for determination of the magnolol from 1.0×10-7 to 1.0×10-4 mol/L with a low detection limit of 5.0×10-8 mol/L. 展开更多
关键词 voltammetry Paste paste remarkably modified graphite paraffin anodic electrolyte silica
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部