The paper describes firstly the principles and scientific train of thought involved in determining the significant seismic monitoring and protection regions (SSMPR) in China. The principles include the gradation princ...The paper describes firstly the principles and scientific train of thought involved in determining the significant seismic monitoring and protection regions (SSMPR) in China. The principles include the gradation principle, i.e. the national level SSMPR and the provincial level SSMPR, the principle of highlighting priorities, namely, the area of an SSMPR should be a fraction of the total area of the country or of the respective province, but the earthquake losses incurred in SSMPR should be a major proportion of the national or provincial ones. The scientific train of thought adopted is to determine the SSMPR on the basis of seismic hazard assessment and loss estimation. Secondly, it reviews the achievements in determining the SSMPRs for the period from 1996 to 2005. The result shows that 10 strong earthquakes occurred during that period in the areas with earthquake monitoring and prediction capability available on the Chinese continent, 8 of which occurred in SSMPRs with the economic loss and death toll accounting for 67% and 92% of the total loss on the Chinese mainland. Lastly, the paper introduces preparatory research for determining the SSMPR for the period from 2006 to 2020, including decade-scale mid-and long-range seismic risk assessment based on seismology, seismogeology, geodesy, earthquake engineering, sociology and stochastics and so on, and the national seismic risk probability map, the seismic hazard (intensity) map, earthquake disaster losses map and the comprehensive seismic risk index, etc. obtained for the period of 2006 to 2020.展开更多
The regulation of the National Significant Seismic Monitoring and Protection Regions(NSSMPR for short) is defined by the Law of the Peoples Republic of China on Protecting Against and Mitigating Earthquake Disasters.T...The regulation of the National Significant Seismic Monitoring and Protection Regions(NSSMPR for short) is defined by the Law of the Peoples Republic of China on Protecting Against and Mitigating Earthquake Disasters.The first stage of implementation of the regulation of NSSMPR in the Chinese mainland was finished from 1996 to 2005.The second stage is being carried on from 2006 to 2020.With the support of the National Social Science Foundation,this paper follows up and evaluates the implementation of the regulation of NSSMPR from 1996 to 2012 in the Chinese mainland.Based on analysis of earthquake examples and investigation data,we find that the effect of disaster mitigation is good,and on this basis,some suggestions are proposed to improve the regulation of NSSMPR.展开更多
A power monitoring and protection system based on an embedded processor was designed for the junction boxes(JBs) of an experimental seafloor observatory network in China. The system exhibits high reliability, fast res...A power monitoring and protection system based on an embedded processor was designed for the junction boxes(JBs) of an experimental seafloor observatory network in China. The system exhibits high reliability, fast response, and high real-time performance. A two-step power management method which uses metal-oxide-semiconductor field-effect transistors(MOSFETs) and a mechanical contactor in series was adopted to generate a reliable power switch, to limit surge currents and to facilitate automatic protection. Grounding fault diagnosis and environmental monitoring were conducted by designing a grounding fault detection circuit and by using selected sensors, respectively. The data collected from the JBs must be time-stamped for analysis and for correlation with other events and data. A highly precise system time, which is necessary for synchronizing the times within and across nodes, was generated through the IEEE 1588(precision clock synchronization protocol for networked measurement and control systems) time synchronization method. In this method, time packets were exchanged between the grandmaster clock at the shore station and the slave clock module of the system. All the sections were verified individually in the laboratory prior to a sea trial. Finally, a subsystem for power monitoring and protection was integrated into the complete node system, installed in a frame, and deployed in the South China Sea. Results of the laboratory and sea trial experiments demonstrated that the developed system was effective, stable, reliable, and suitable for continuous deep-sea operation.展开更多
A new type of corrosion inhibitor and fog suppressor composed of Nitrogen-containing alkaloid,water-soluble butadiene lower polymer, and inorganic electrolyte has been investigated by gravimetric and electrochemical m...A new type of corrosion inhibitor and fog suppressor composed of Nitrogen-containing alkaloid,water-soluble butadiene lower polymer, and inorganic electrolyte has been investigated by gravimetric and electrochemical method. Effects or this chemicals on pickling rate and hydrogen penetration into iron and steel material in 50~150 g/L HCI or/and H2SO4 solutions at 20~70℃ temperature were examined. The amount of acid fog escaping from the surface of air-liquid was determined by chemical titration. The results indicate that the efficiency of inhibition and suppression depends on film properties by which mean a barrier film on the interface of bare mild steel/solution or an unsolvable liquid membrane as hydrophibic effect.In present work the film-forming mechanism by in situ and chemistry-mechanics effect is also discussed.展开更多
At present,smart substations use the IEC61850 standard based on the architectural framework of three layers and two networks to realize information digitization and advanced applications.Although the smart substation ...At present,smart substations use the IEC61850 standard based on the architectural framework of three layers and two networks to realize information digitization and advanced applications.Although the smart substation offers many improvements in design,equipment manufacturing,and construction,the intelligent devices used in smart substations are costly,and are also difficult to maintain since they are dispersed within a single unit.Functionality optimization and device integration,thus,have become important issues in smart substation development.This paper presents an integrated solution and implementation process for a smart substation system.In the process layer,an integrated intelligence component is developed that functions both as an intelligent terminal and a merging unit.In the bay layer,an integrated station-area protection measurement and control master device is designed to achieve such functions as protection,monitoring,control,fault recorder,and power quality monitoring.Finally,in the station control layer,an integrated information platform is established to bring together various system functions and to promote interactive sharing.Integration technology improves the economy and practicality of the smart substation,especially in a distribution power grid.展开更多
基金the Special Public Welfare Project of Ministry of Science and Technology of China (2004DIA3J010)
文摘The paper describes firstly the principles and scientific train of thought involved in determining the significant seismic monitoring and protection regions (SSMPR) in China. The principles include the gradation principle, i.e. the national level SSMPR and the provincial level SSMPR, the principle of highlighting priorities, namely, the area of an SSMPR should be a fraction of the total area of the country or of the respective province, but the earthquake losses incurred in SSMPR should be a major proportion of the national or provincial ones. The scientific train of thought adopted is to determine the SSMPR on the basis of seismic hazard assessment and loss estimation. Secondly, it reviews the achievements in determining the SSMPRs for the period from 1996 to 2005. The result shows that 10 strong earthquakes occurred during that period in the areas with earthquake monitoring and prediction capability available on the Chinese continent, 8 of which occurred in SSMPRs with the economic loss and death toll accounting for 67% and 92% of the total loss on the Chinese mainland. Lastly, the paper introduces preparatory research for determining the SSMPR for the period from 2006 to 2020, including decade-scale mid-and long-range seismic risk assessment based on seismology, seismogeology, geodesy, earthquake engineering, sociology and stochastics and so on, and the national seismic risk probability map, the seismic hazard (intensity) map, earthquake disaster losses map and the comprehensive seismic risk index, etc. obtained for the period of 2006 to 2020.
基金sponsored by the National Social Science Foundation of China"Research on the Status,Efficiencies and the Policy on the National Significant Seismic Monitoring and Protection Regions"(11&ZD054)
文摘The regulation of the National Significant Seismic Monitoring and Protection Regions(NSSMPR for short) is defined by the Law of the Peoples Republic of China on Protecting Against and Mitigating Earthquake Disasters.The first stage of implementation of the regulation of NSSMPR in the Chinese mainland was finished from 1996 to 2005.The second stage is being carried on from 2006 to 2020.With the support of the National Social Science Foundation,this paper follows up and evaluates the implementation of the regulation of NSSMPR from 1996 to 2012 in the Chinese mainland.Based on analysis of earthquake examples and investigation data,we find that the effect of disaster mitigation is good,and on this basis,some suggestions are proposed to improve the regulation of NSSMPR.
基金Project supported by the National High-Tech R&D Program(863 Program)of China(Nos.2012AA09A408 and 2012AA09A402)the National Natural Science Foundation of China(No.51409229)the Zhejiang Provincial Natural Science Foundation of China(No.LQ14E070002)
文摘A power monitoring and protection system based on an embedded processor was designed for the junction boxes(JBs) of an experimental seafloor observatory network in China. The system exhibits high reliability, fast response, and high real-time performance. A two-step power management method which uses metal-oxide-semiconductor field-effect transistors(MOSFETs) and a mechanical contactor in series was adopted to generate a reliable power switch, to limit surge currents and to facilitate automatic protection. Grounding fault diagnosis and environmental monitoring were conducted by designing a grounding fault detection circuit and by using selected sensors, respectively. The data collected from the JBs must be time-stamped for analysis and for correlation with other events and data. A highly precise system time, which is necessary for synchronizing the times within and across nodes, was generated through the IEEE 1588(precision clock synchronization protocol for networked measurement and control systems) time synchronization method. In this method, time packets were exchanged between the grandmaster clock at the shore station and the slave clock module of the system. All the sections were verified individually in the laboratory prior to a sea trial. Finally, a subsystem for power monitoring and protection was integrated into the complete node system, installed in a frame, and deployed in the South China Sea. Results of the laboratory and sea trial experiments demonstrated that the developed system was effective, stable, reliable, and suitable for continuous deep-sea operation.
文摘A new type of corrosion inhibitor and fog suppressor composed of Nitrogen-containing alkaloid,water-soluble butadiene lower polymer, and inorganic electrolyte has been investigated by gravimetric and electrochemical method. Effects or this chemicals on pickling rate and hydrogen penetration into iron and steel material in 50~150 g/L HCI or/and H2SO4 solutions at 20~70℃ temperature were examined. The amount of acid fog escaping from the surface of air-liquid was determined by chemical titration. The results indicate that the efficiency of inhibition and suppression depends on film properties by which mean a barrier film on the interface of bare mild steel/solution or an unsolvable liquid membrane as hydrophibic effect.In present work the film-forming mechanism by in situ and chemistry-mechanics effect is also discussed.
基金supported in part by the research program of State Grid Corporation of China under Grant PD71-15-036.
文摘At present,smart substations use the IEC61850 standard based on the architectural framework of three layers and two networks to realize information digitization and advanced applications.Although the smart substation offers many improvements in design,equipment manufacturing,and construction,the intelligent devices used in smart substations are costly,and are also difficult to maintain since they are dispersed within a single unit.Functionality optimization and device integration,thus,have become important issues in smart substation development.This paper presents an integrated solution and implementation process for a smart substation system.In the process layer,an integrated intelligence component is developed that functions both as an intelligent terminal and a merging unit.In the bay layer,an integrated station-area protection measurement and control master device is designed to achieve such functions as protection,monitoring,control,fault recorder,and power quality monitoring.Finally,in the station control layer,an integrated information platform is established to bring together various system functions and to promote interactive sharing.Integration technology improves the economy and practicality of the smart substation,especially in a distribution power grid.