期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Dechlorination of disinfection by-product monochloroacetic acid in drinking water by nanoscale palladized iron bimetallic particle 被引量:7
1
作者 CHEN, Chao WANG, Xiangyu +1 位作者 CHANG, Ying LIU, Huiling 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2008年第8期945-951,共7页
Nanoscale palladized iron(Pd/Fe)bimetallic particles were prepared by reductive deposition method.The particles were characterized by X-ray diffraction(XRD),X-ray fluorescence(XRF),scanning electron microscope(SEM),tr... Nanoscale palladized iron(Pd/Fe)bimetallic particles were prepared by reductive deposition method.The particles were characterized by X-ray diffraction(XRD),X-ray fluorescence(XRF),scanning electron microscope(SEM),transmission electron microscope(TEM),and Brunauer-Emmett-Teller-nitrogen(BET-N_2)method.Data obtained from those methods indicated that nanoscale Pd/Fe bimetallic particles containedα-Fe^0.Detected Pd to Fe ratio by weight(Pd/Fe ratio)was close to theoretical value. Spherical granules with diame... 展开更多
关键词 nanoscale Pd/Fe bimetallic particles DECHLORINATION monochloroacetic acid
下载PDF
Determination of Glycolate Acid, Mono- and Dichloroacetic Acids in Synthetical Betaine by Anion-exchange Chromatography 被引量:3
2
作者 石海宁 王宗花 +2 位作者 王辉 赵锐 丁明玉 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2011年第4期778-782,共5页
An anion-exchange chromatography method combined solid phase extraction (SPE) was developed for the simultaneous analysis of glycolate acid (GL), monochloroacetic acid (MCA) and dichloroacetic acid (DCA) in sy... An anion-exchange chromatography method combined solid phase extraction (SPE) was developed for the simultaneous analysis of glycolate acid (GL), monochloroacetic acid (MCA) and dichloroacetic acid (DCA) in synthetical betaine products. The analytes and unknown anionic impurities were well separated on a Metrosep A supp5 anion-exchange column (150 mm×4 mm) with 2.0 mmol/L Na2CO3+2.0 mmol/L NaHCO3 solution as eluent. Suppressed conductivity detection was used. A strong cation exchange (SCX) solid phase extraction (SPE) cartridge was used to reduce the concentration of matrix betaine and a Cleanert IC-Ag pretreatment cartridge was used to remove high Cl- concentration. The detection limits of GL, MCA and DCA were 0.09, 0.017 and 0.05 μg/L, respectively. The relative standard deviations (RSDs) of the retention times and peak areas were less than 0.09% and 0.49%, respectively. The recoveries of the three analytes were between 90.6% and 100.8%. The analytical results showed that GL and DCA were present in high concentration and no MCA was found when the proposed ion chromatography method was applied to three synthetical betaine samples. The proposed method is simple, sensitive and timesaving, and is also suitable for routine analysis in quality control of synthetical betaine products. 展开更多
关键词 ion chromatography (IC) solid phase extraction (SPE) glycolate acid monochloroacetic acid dichloroacetic acid synthetical betaine
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部