Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect o...Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect of the cooling water flow,thickness of the plate,and motor loss density on the cooling effect of the water cold plate were studied.To compare the cooling performance of water cold plate and outer spiral water jacket cooling structures,a high-speed permanent magnet motor with a high loss density was used to establish two motor models with the two cooling structures.Consequently,the cooling effects of the two models were analyzed using the finite element method under the same loss density,coolant flow,and main dimensions.The results were as follows.(1)The maximum and average temperatures of the water cold plate structure were reduced by 25.5%and 30.5%,respectively,compared to that of the outer spiral water jacket motor;(2)Compared with the outer spiral water jacket structure,the water cold plate structure can reduce the overall mass and volume of the motor.Considering a 100 kW high-speed permanent magnet motor as an example,a water cold plate cooling system was designed,and the temperature distribution is analyzed,with the result indicating that the cooling structure satisfied the cooling requirements of the high loss density motor.展开更多
This paper presents an analysis based on analytical method for solid rotor motors for determining the rotor eddy current losses due to the current harmonics of the stator winding. The accuracy of the analytical result...This paper presents an analysis based on analytical method for solid rotor motors for determining the rotor eddy current losses due to the current harmonics of the stator winding. The accuracy of the analytical results is verified by experiments.展开更多
High speed and high efficiency synchronized electric motors are favored in the automotive industry and turbo machinery industry worldwide because of the demands placed on efficiency. Herein an electric motor thermal c...High speed and high efficiency synchronized electric motors are favored in the automotive industry and turbo machinery industry worldwide because of the demands placed on efficiency. Herein an electric motor thermal control system using cooling air which enters from the drive end of the motor and exits from the non-drive end of the motor as the rotor experiences dissipates heat is addressed using CFD. Analyses using CFD can help to find the appropriate mass flow rate and windage losses while satisfying temperature requirements on the motor. Here, the air flow through a small annular gap is fed at 620 L/min (0.011 kg/sec) as the rotor spins at 100,000 rpm (10,472 rad/sec) and the rotor dissipates 200 W. The CFD results are compared with experimental results. Based upon the CFD findings, a novel heat transfer correlation suitable for large axial Reynolds number, large Taylor number, small annular gap Taylor-Couette flows subject to axial cross-flow is proposed herein.展开更多
The aim of this paper is to present the eddy current losses in solid pole shoes in a permanent magnet two-pole electric motor. In the presented paper, the authors have chosen to work with three different analytical mo...The aim of this paper is to present the eddy current losses in solid pole shoes in a permanent magnet two-pole electric motor. In the presented paper, the authors have chosen to work with three different analytical models, Carter’s theory, Gibb’s theory and Lawrenson’s theory, each with different degree of accuracy and simplifications. The results from the analytical models all present relatively low eddy current losses, giving the designer valuable arguments to utilize solid pole shoes, as a rotor with solid poles is from a construction point of view a more suitable choice, increasing the mechanical stability and reducing the production cost, compared to the laminated design.展开更多
基金supported by the National Natural Science Foundation of China(51920105011)Natural Science Foundation of Liaoning Province(2021-YQ-09)Liaoning Bai Qian Wan Talents Program,China.
文摘Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect of the cooling water flow,thickness of the plate,and motor loss density on the cooling effect of the water cold plate were studied.To compare the cooling performance of water cold plate and outer spiral water jacket cooling structures,a high-speed permanent magnet motor with a high loss density was used to establish two motor models with the two cooling structures.Consequently,the cooling effects of the two models were analyzed using the finite element method under the same loss density,coolant flow,and main dimensions.The results were as follows.(1)The maximum and average temperatures of the water cold plate structure were reduced by 25.5%and 30.5%,respectively,compared to that of the outer spiral water jacket motor;(2)Compared with the outer spiral water jacket structure,the water cold plate structure can reduce the overall mass and volume of the motor.Considering a 100 kW high-speed permanent magnet motor as an example,a water cold plate cooling system was designed,and the temperature distribution is analyzed,with the result indicating that the cooling structure satisfied the cooling requirements of the high loss density motor.
文摘This paper presents an analysis based on analytical method for solid rotor motors for determining the rotor eddy current losses due to the current harmonics of the stator winding. The accuracy of the analytical results is verified by experiments.
文摘High speed and high efficiency synchronized electric motors are favored in the automotive industry and turbo machinery industry worldwide because of the demands placed on efficiency. Herein an electric motor thermal control system using cooling air which enters from the drive end of the motor and exits from the non-drive end of the motor as the rotor experiences dissipates heat is addressed using CFD. Analyses using CFD can help to find the appropriate mass flow rate and windage losses while satisfying temperature requirements on the motor. Here, the air flow through a small annular gap is fed at 620 L/min (0.011 kg/sec) as the rotor spins at 100,000 rpm (10,472 rad/sec) and the rotor dissipates 200 W. The CFD results are compared with experimental results. Based upon the CFD findings, a novel heat transfer correlation suitable for large axial Reynolds number, large Taylor number, small annular gap Taylor-Couette flows subject to axial cross-flow is proposed herein.
文摘The aim of this paper is to present the eddy current losses in solid pole shoes in a permanent magnet two-pole electric motor. In the presented paper, the authors have chosen to work with three different analytical models, Carter’s theory, Gibb’s theory and Lawrenson’s theory, each with different degree of accuracy and simplifications. The results from the analytical models all present relatively low eddy current losses, giving the designer valuable arguments to utilize solid pole shoes, as a rotor with solid poles is from a construction point of view a more suitable choice, increasing the mechanical stability and reducing the production cost, compared to the laminated design.