期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
A Brief introduction on Electric-Wind-Thermal Moxibustion Apparatus
1
作者 Xu Jingtang,Tang Yongfen(Anhui College of TCM) 《中国针灸》 CAS CSCD 北大核心 1995年第S2期385-386,共2页
ABriefIntroductiononElectric-Wind-ThermalMoxibustionApparatus¥XuJingtang,TangYongfen(AnhuiCollegeofTCM)Anewm... ABriefIntroductiononElectric-Wind-ThermalMoxibustionApparatus¥XuJingtang,TangYongfen(AnhuiCollegeofTCM)Anewmoxibustioninstrum?.. 展开更多
关键词 WIND A Brief introduction on Electric-Wind-Thermal moxibustion apparatus
下载PDF
Electronic moxibustion apparatus and traditional moxibustion in treating knee osteoarthritis:a randomized controlled trial 被引量:3
2
作者 Xue Kun Xing Qiu-juan +3 位作者 Wang Ya-qiong Wu Ji Zhao Hai-yin Lu Wang 《Journal of Acupuncture and Tuina Science》 CSCD 2020年第4期286-294,共9页
Objective:To observe the clinical efficacy of DZWJY-1 type electronic moxibustion apparatus and traditional moxibustion in treating knee osteoarthritis(KOA).Methods:A total of 76 eligible patients were randomized into... Objective:To observe the clinical efficacy of DZWJY-1 type electronic moxibustion apparatus and traditional moxibustion in treating knee osteoarthritis(KOA).Methods:A total of 76 eligible patients were randomized into an electronic moxibustion apparatus group and a traditional moxibustion group,with 38 cases in each group.The electronic moxibustion apparatus group was intervened by DZWJY-1 type electronic moxibustion apparatus,and the traditional moxibustion group received moxa stick moxibustion for treatment.Neixiyan(EX-LE 4),Dubi(ST 35),Xuehai(SP 10)and Liangqiu(ST 34)were selected for both groups and the treatment was conducted 3 times a week for a total of 12 times.The visual analog scale(VAS)and the Western Ontario and McMaster Universities osteoarthritis index(WOMAC)scores were observed before treatment and after 6 and 12 sessions of treatment,respectively.Results:There were 4 dropout cases in the traditional moxibustion group.Therefore,this trial had 72 valid cases,including 38 cases in the electronic moxibustion apparatus group and 34 cases in the traditional moxibustion group,the differences in the baseline data between the two groups were statistically insignificant(P>0.05).After 6 and 12 sessions of treatment,the VAS scores decreased significantly with the increase of treatment sessions in both groups(all P<0.01),and the betweengroup differences were statistically insignificant at the same time points(both P>0.05).The pain intensity was evaluated using the weighted value of VAS score.The markedly effective rate was 47.4%and the total effective rate was 89.5%in the electronic moxibustion apparatus group,versus 50.0%and 94.1%in the traditional moxibustion group,and the betweengroup differences were statistically insignificant(both P>0.05).After 6 and 12 sessions of treatment,the total score and the component scores including pain,stiffness and difficulty moving in the WOMAC decreased significantly with the increase of treatment sessions in both groups(all P<0.01),and the between-group differences were statistically insignificant(all P>0.05).Conclusion:Electronic moxibustion apparatus and traditional moxibustion both are effective in reducing joint pain and improving joint function in KOA patients,and they are equivalent comparing the clinical efficacy. 展开更多
关键词 moxibustion Therapy Moxa Stick moxibustion Electronic moxibustion apparatus Osteoarthritis Knee Pain Measurement Visual Analog Scale
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部