采用离子分子质谱IMR-MS(ion molecule reaction mass spectrometry)与转盘式吸烟机RM20H相连的方法,对卷烟主流烟气中气相成分建立了在线、实时、高效的逐口定量检测方法。该方法日内重复性、日间重复性结果显示除最后一口由于抽吸烟...采用离子分子质谱IMR-MS(ion molecule reaction mass spectrometry)与转盘式吸烟机RM20H相连的方法,对卷烟主流烟气中气相成分建立了在线、实时、高效的逐口定量检测方法。该方法日内重复性、日间重复性结果显示除最后一口由于抽吸烟气量不同,RSD较大外,其他抽吸口数RSD均小于15%。用该方法测定标准卷烟2R4F、3R4F和1R5F,并将结果与文献经典方法进行比较,数据显示本方法定量结果准确。展开更多
An off-line chelation system combined with ICP-MS technique was developed for the quantitative determination of trace elements in seawater,namely V,Co,Ni,Cu,Zn,Mo,Cd,Pb,U and rare earth elements(REEs).The system was...An off-line chelation system combined with ICP-MS technique was developed for the quantitative determination of trace elements in seawater,namely V,Co,Ni,Cu,Zn,Mo,Cd,Pb,U and rare earth elements(REEs).The system was built based on an ion chromatography equipped with MetPac CC-1 chelation columns which had a strong selective chelation to these target elements within a pH range 5.2—5.6.Acidified seawater samples and NH4Ac(2 mol/L) were blended to meet suitable pH before being injected into the chelation column,thus target elements were retained while alkali and alkaline metals were excluded.Then chelated elements were eluted by HNO3(1 mol/L) and samples were collected for ICP-MS analysis.Varying the ratio of input(gen.200 mL) to output(gen.5 mL),the target elements which were concentrated as 40 times as their concentrations were far beyond instrumental quantification limits.At last,a certificated seawater CASS-4 was introduced and our detected values were in good agreement with those certified values.展开更多
文摘采用离子分子质谱IMR-MS(ion molecule reaction mass spectrometry)与转盘式吸烟机RM20H相连的方法,对卷烟主流烟气中气相成分建立了在线、实时、高效的逐口定量检测方法。该方法日内重复性、日间重复性结果显示除最后一口由于抽吸烟气量不同,RSD较大外,其他抽吸口数RSD均小于15%。用该方法测定标准卷烟2R4F、3R4F和1R5F,并将结果与文献经典方法进行比较,数据显示本方法定量结果准确。
文摘An off-line chelation system combined with ICP-MS technique was developed for the quantitative determination of trace elements in seawater,namely V,Co,Ni,Cu,Zn,Mo,Cd,Pb,U and rare earth elements(REEs).The system was built based on an ion chromatography equipped with MetPac CC-1 chelation columns which had a strong selective chelation to these target elements within a pH range 5.2—5.6.Acidified seawater samples and NH4Ac(2 mol/L) were blended to meet suitable pH before being injected into the chelation column,thus target elements were retained while alkali and alkaline metals were excluded.Then chelated elements were eluted by HNO3(1 mol/L) and samples were collected for ICP-MS analysis.Varying the ratio of input(gen.200 mL) to output(gen.5 mL),the target elements which were concentrated as 40 times as their concentrations were far beyond instrumental quantification limits.At last,a certificated seawater CASS-4 was introduced and our detected values were in good agreement with those certified values.