The main goal of this study was to introduce a novel three-dimensional procedure to objectively quantify both inner and outer condylar remodelling on preoperative multi-slice computed tomography (MSCT) and postopera...The main goal of this study was to introduce a novel three-dimensional procedure to objectively quantify both inner and outer condylar remodelling on preoperative multi-slice computed tomography (MSCT) and postoperative cone-beam computed tomography (CBCT) images. Second, the reliability and accuracy of this condylar volume quantification method was assessed. The mandibles of 20 patients (11 female and 9 male) who underwent bimaxillary surgery were semi-automatically extracted from MSCT/CBCT scans and rendered in 3D. The resulting condyles were spatially matched by using an anatomical landmark-based registration procedure. A standardized sphere was created around each condyle, and the condylar bone volume within this selected region of interest was automatically calculated. To investigate the reproducibility of the method, inter- and intra-observer reliability was calculated for assessments made by two experienced radiologists twice five months apart in a set of ten randomly selected patients. To test the accuracy of the bone segmentation, the inner and outer bone structures of one dry mandible, scanned according to the clinical set-up, were compared with the gold standard, micro-CT. Thirty-eight condyles showed a significant (P〈O.05) mean bone volume decrease of 26.4%_ 11.4% (502.9 mm3+ 268.1 mm3). No significant effects of side, sex or age were found. Good to excellent (ICC〉 0.6) intra- and inter-observer reliability was observed for both MSCT and CBCT. Moreover, the bone segmentation accuracy was less than one voxel (0.4 mm) for MSCT (0.3 mm __. 0.2 mm) and CBCT (0.4 mm _ 0.3 mm), thus indicating the clinical potential of this method for objective follow-up in pathological condylar resorption.展开更多
The traditional crack exploring method with echo (reflected wave) in metals is called the "single-wave detecting method" that uses a probe of single weight. This method is not able to detect directly the size and ...The traditional crack exploring method with echo (reflected wave) in metals is called the "single-wave detecting method" that uses a probe of single weight. This method is not able to detect directly the size and shape of the crack and the result can only be obtained by relative comparison, that is to compare the echo amplitudes of the unknown quantity (crack) with the known quantity (regular artificial crack) to determine the equivalent size and shape of a certain crack.展开更多
Multi-detector row computed tomography urography (MDCTU) becomes the imaging modality of choice for evaluation of the kidneys and urinary tract. The aim of this study was to discuss and illustrate the role of MDCTU, o...Multi-detector row computed tomography urography (MDCTU) becomes the imaging modality of choice for evaluation of the kidneys and urinary tract. The aim of this study was to discuss and illustrate the role of MDCTU, on a 32-row CT scanner in the evaluation a variety of entities that were frequently associated with microscopic hematuria in adults. This prospective cohort study was performed in the period of August 2013 to October 2014. Fifty positive participants to microscopic hematuria were examined at the radiology department of Alnilin Diagnostic Medical Center and Antalya Medical Center. Computed tomography urography (CTU) scanning was performed using two powerful performances, high speed multi-detector row on 32-row CT scanners (Siemens Healthcare Global, Somatom Emotion Duo Eco). Statistical analysis was done through the standard Statistical Package for the Social Sciences (SPSS Inc., Chicago, IL, USA) version 15 for windows. MDCTU established the correct cause of microscopic hematuria in (44;88%) of participants. In (6;12%) of participants, no cause of hematuria was identified based on the standard of references. The causes of hematuria in (41;82%) participants were diseases in the upper urinary tract, while urinary bladder neoplasms (2;4%) and diverticulum (1;2%) were the causes of hematuria (3;6%) in the lower urinary tract. Thirty two-row MDCTU scanner demonstrated satisfactory results in the investigation of microscopic hematuria, being able to demonstrate a wide spectrum of diseases affecting the urinary tract is the main advantage of the technique.展开更多
基金the Coordination for the Improvement of Higher Education Personnel(CAPES)programmeScience without borders from Brazilian governmentthe Research Foundation Flanders(FWO)from Flemish government for the fellowship support
文摘The main goal of this study was to introduce a novel three-dimensional procedure to objectively quantify both inner and outer condylar remodelling on preoperative multi-slice computed tomography (MSCT) and postoperative cone-beam computed tomography (CBCT) images. Second, the reliability and accuracy of this condylar volume quantification method was assessed. The mandibles of 20 patients (11 female and 9 male) who underwent bimaxillary surgery were semi-automatically extracted from MSCT/CBCT scans and rendered in 3D. The resulting condyles were spatially matched by using an anatomical landmark-based registration procedure. A standardized sphere was created around each condyle, and the condylar bone volume within this selected region of interest was automatically calculated. To investigate the reproducibility of the method, inter- and intra-observer reliability was calculated for assessments made by two experienced radiologists twice five months apart in a set of ten randomly selected patients. To test the accuracy of the bone segmentation, the inner and outer bone structures of one dry mandible, scanned according to the clinical set-up, were compared with the gold standard, micro-CT. Thirty-eight condyles showed a significant (P〈O.05) mean bone volume decrease of 26.4%_ 11.4% (502.9 mm3+ 268.1 mm3). No significant effects of side, sex or age were found. Good to excellent (ICC〉 0.6) intra- and inter-observer reliability was observed for both MSCT and CBCT. Moreover, the bone segmentation accuracy was less than one voxel (0.4 mm) for MSCT (0.3 mm __. 0.2 mm) and CBCT (0.4 mm _ 0.3 mm), thus indicating the clinical potential of this method for objective follow-up in pathological condylar resorption.
基金National Natural Science Fundation of China (60172061).
文摘The traditional crack exploring method with echo (reflected wave) in metals is called the "single-wave detecting method" that uses a probe of single weight. This method is not able to detect directly the size and shape of the crack and the result can only be obtained by relative comparison, that is to compare the echo amplitudes of the unknown quantity (crack) with the known quantity (regular artificial crack) to determine the equivalent size and shape of a certain crack.
文摘Multi-detector row computed tomography urography (MDCTU) becomes the imaging modality of choice for evaluation of the kidneys and urinary tract. The aim of this study was to discuss and illustrate the role of MDCTU, on a 32-row CT scanner in the evaluation a variety of entities that were frequently associated with microscopic hematuria in adults. This prospective cohort study was performed in the period of August 2013 to October 2014. Fifty positive participants to microscopic hematuria were examined at the radiology department of Alnilin Diagnostic Medical Center and Antalya Medical Center. Computed tomography urography (CTU) scanning was performed using two powerful performances, high speed multi-detector row on 32-row CT scanners (Siemens Healthcare Global, Somatom Emotion Duo Eco). Statistical analysis was done through the standard Statistical Package for the Social Sciences (SPSS Inc., Chicago, IL, USA) version 15 for windows. MDCTU established the correct cause of microscopic hematuria in (44;88%) of participants. In (6;12%) of participants, no cause of hematuria was identified based on the standard of references. The causes of hematuria in (41;82%) participants were diseases in the upper urinary tract, while urinary bladder neoplasms (2;4%) and diverticulum (1;2%) were the causes of hematuria (3;6%) in the lower urinary tract. Thirty two-row MDCTU scanner demonstrated satisfactory results in the investigation of microscopic hematuria, being able to demonstrate a wide spectrum of diseases affecting the urinary tract is the main advantage of the technique.