When a steel plate produced by a steel plant leaves the factory,its upper surface should be marked with the specification,variety,batch number,and other identifying information,and its side should be marked with a sid...When a steel plate produced by a steel plant leaves the factory,its upper surface should be marked with the specification,variety,batch number,and other identifying information,and its side should be marked with a side marking.The side marking contains the plate number,specification,batch number,and other information,which are convenient for customers to accurately identify relevant information after stacking.However,because of the influence of weather,environment,and other factors,the side marking becomes unidentifiable when the steel plate is corroded,affecting the customer’s loading,unloading,and other operations.The development and application of side anticorrosion devices and cleaning of finished heavy steel plates with antirust agents will solve the problem of unrecognizable side marking due to corrosion.展开更多
Purpose – Straightness measurement of rail weld joint is of essential importance to railway maintenance. Dueto the lack of efficient measurement equipment, there has been limited in-depth research on rail weld joint ...Purpose – Straightness measurement of rail weld joint is of essential importance to railway maintenance. Dueto the lack of efficient measurement equipment, there has been limited in-depth research on rail weld joint with a5-m wavelength range, leaving a significant knowledge gap in this field.Design/methodology/approach – In this study, the authors used the well-established inertial referencemethod (IR-method), and the state-of-the-art multi-point chord reference method (MCR-method). Two methodshave been applied in different types of rail straightness measurement trollies, respectively. These instrumentswere tested in a high-speed rail section within a certain region of China. The test results were ultimatelyvalidated through using traditional straightedge and feeler gauge methods as reference data to evaluate the railweld joint straightness within the 5-m wavelength range.Findings – The research reveals that IR-method and MCR-method produce reasonably similar measurementresults for wavelengths below 1 m. However, MCR-method outperforms IR-method in terms of accuracy forwavelengths exceeding 3 m. Furthermore, it was observed that IR-method, while operating at a slower speed,carries the risk of derailing and is incapable of detecting rail weld joints and low joints within the track.Originality/value – The research compare two methods’ measurement effects in a longer wavelength rangeand demonstrate the superiority of MCR-method.展开更多
针对当前集成了不同厂家几套子系统的一些燃驱压缩机组控制系统结构复杂、维护成本高等问题,应用基于Mark VIe控制平台来升级改造该系统。以某改造项目为例,应用双冗余Mark VIe控制系统架构,Mark VIe SIL3模件作为紧急停机和火气保护系...针对当前集成了不同厂家几套子系统的一些燃驱压缩机组控制系统结构复杂、维护成本高等问题,应用基于Mark VIe控制平台来升级改造该系统。以某改造项目为例,应用双冗余Mark VIe控制系统架构,Mark VIe SIL3模件作为紧急停机和火气保护系统的硬件,同时采用Mark VIe ControlST统一软件平台。结果表明:新控制系统采用了一体化硬件、软件设计,提高了机组控制系统的安全可靠性,有利于日常运行维护,而且新系统具有在线监测功能,有助于系统故障排查。展开更多
佳能Cinema EOS电影摄影机EOS C500 Mark II日前发布了新固件版本1.1.1.1。经过此次固件升级,EOS C500 Mark II可支持三种新增的Cinema RAW Light记录格式:具有高画质的RAW HQ模式、标准画质的RAW ST模式和精简记录可以延长记录时间的RA...佳能Cinema EOS电影摄影机EOS C500 Mark II日前发布了新固件版本1.1.1.1。经过此次固件升级,EOS C500 Mark II可支持三种新增的Cinema RAW Light记录格式:具有高画质的RAW HQ模式、标准画质的RAW ST模式和精简记录可以延长记录时间的RAW LT模式。展开更多
OpticalMark Recognition(OMR)systems have been studied since 1970.It is widely accepted as a data entry technique.OMR technology is used for surveys and multiple-choice questionnaires.Due to its ease of use,OMR technol...OpticalMark Recognition(OMR)systems have been studied since 1970.It is widely accepted as a data entry technique.OMR technology is used for surveys and multiple-choice questionnaires.Due to its ease of use,OMR technology has grown in popularity over the past two decades and is widely used in universities and colleges to automatically grade and grade student responses to questionnaires.The accuracy of OMR systems is very important due to the environment inwhich they are used.TheOMRalgorithm relies on pixel projection or Hough transform to determine the exact answer in the document.These techniques rely on majority voting to approximate a predetermined shape.The performance of these systems depends on precise input from dedicated hardware.Printing and scanning OMR tables introduces artifacts that make table processing error-prone.This observation is a fundamental limitation of traditional pixel projection and Hough transform techniques.Depending on the type of artifact introduced,accuracy is affected differently.We classified the types of errors and their frequency according to the artifacts in the OMR system.As a major contribution,we propose an improved algorithm that fixes errors due to skewness.Our proposal is based on the Hough transform for improving the accuracy of bias correction mechanisms in OMR documents.As a minor contribution,our proposal also improves the accuracy of detecting markers in OMR documents.The results show an improvement in accuracy over existing algorithms in each of the identified problems.This improvement increases confidence in OMR document processing and increases efficiency when using automated OMR document processing.展开更多
Corona discharge, as a common means to obtain non-equilibrium plasma, can generally obtain high-concentration plasma by increasing discharge points to meet production needs. However,the existing numerical simulation m...Corona discharge, as a common means to obtain non-equilibrium plasma, can generally obtain high-concentration plasma by increasing discharge points to meet production needs. However,the existing numerical simulation models used to study multi-point corona discharge are all calculations of small-scale space models, which cannot obtain the distribution characteristics of plasma in large space. Based on our previous research, this paper proposes a hybrid model for studying the distribution of multi-point discharge plasma in large-scale spaces, which divides the computational domain and computes separately with the hydrodynamic model and the ion mobility model. The simulation results are verified by a needle–ball electrode device. Firstly, the electric field distribution and plasma distribution of the needle electrodes with single tip and double tips are compared and discussed. Secondly, the plasma distribution of the needle electrode with the double tip at different voltages is investigated. Both computational and experimental results indicate that the charged particle concentration and current of the needle electrode with double tips are both twice as high as those of the needle electrode with a single tip. This model can extend the computational area of the multi-point corona discharge finite element model to the sub-meter(25 cm) or meter level, which provides an effective means to study the plasma distribution generated by multiple discharge points in large-scale space.展开更多
Introduction: Endotracheal suction plays a crucial role in the management of mechanically ventilated patients. This study aims to evaluate the clinical effectiveness and safety of suction tubes with markings in mechan...Introduction: Endotracheal suction plays a crucial role in the management of mechanically ventilated patients. This study aims to evaluate the clinical effectiveness and safety of suction tubes with markings in mechanically ventilated pediatric patients. Materials and Methods: A randomized assignment was carried out on a cohort of 52 pediatric patients who underwent mechanical ventilation in the Pediatric Intensive Care Unit at the Third Affiliated Hospital of Sun Yat-sen University, covering the period from January 2022 to December 2022. These patients were divided into two groups: an improved group (n = 26) utilizing marked suction tubes, and a regular group (n = 26) employing conventional suction tubes. The objective of our study was to evaluate the clinical effectiveness of marked suction tubes. Results: The effects of the improved group on the vital signs of children undergoing mechanical ventilation were small and statistically significant compared with the regular group (p < 0.05). Additionally, the improved group exhibited a reduced frequency of sputum suction, shorter mechanical ventilation duration, and fewer days of hospitalization in the PICU compared to the regular group during the ventilation period. Notably, the difference in the duration of PICU hospitalization was statistically significant (p < 0.05). Moreover, the incidence of adverse reactions in the improved group was notably lower, with statistically significant differences observed in airway mucous membrane damage and irritating cough when compared to the regular group (p < 0.05). Conclusion: The utilization of marked suction tubes provides clinical nurses with clear guidance for performing suctioning with ease, efficiency and safety. Consequently, advocating for the widespread implementation of marked suction tubes in clinical practice is a commendable pursuit.展开更多
文摘When a steel plate produced by a steel plant leaves the factory,its upper surface should be marked with the specification,variety,batch number,and other identifying information,and its side should be marked with a side marking.The side marking contains the plate number,specification,batch number,and other information,which are convenient for customers to accurately identify relevant information after stacking.However,because of the influence of weather,environment,and other factors,the side marking becomes unidentifiable when the steel plate is corroded,affecting the customer’s loading,unloading,and other operations.The development and application of side anticorrosion devices and cleaning of finished heavy steel plates with antirust agents will solve the problem of unrecognizable side marking due to corrosion.
文摘Purpose – Straightness measurement of rail weld joint is of essential importance to railway maintenance. Dueto the lack of efficient measurement equipment, there has been limited in-depth research on rail weld joint with a5-m wavelength range, leaving a significant knowledge gap in this field.Design/methodology/approach – In this study, the authors used the well-established inertial referencemethod (IR-method), and the state-of-the-art multi-point chord reference method (MCR-method). Two methodshave been applied in different types of rail straightness measurement trollies, respectively. These instrumentswere tested in a high-speed rail section within a certain region of China. The test results were ultimatelyvalidated through using traditional straightedge and feeler gauge methods as reference data to evaluate the railweld joint straightness within the 5-m wavelength range.Findings – The research reveals that IR-method and MCR-method produce reasonably similar measurementresults for wavelengths below 1 m. However, MCR-method outperforms IR-method in terms of accuracy forwavelengths exceeding 3 m. Furthermore, it was observed that IR-method, while operating at a slower speed,carries the risk of derailing and is incapable of detecting rail weld joints and low joints within the track.Originality/value – The research compare two methods’ measurement effects in a longer wavelength rangeand demonstrate the superiority of MCR-method.
文摘针对当前集成了不同厂家几套子系统的一些燃驱压缩机组控制系统结构复杂、维护成本高等问题,应用基于Mark VIe控制平台来升级改造该系统。以某改造项目为例,应用双冗余Mark VIe控制系统架构,Mark VIe SIL3模件作为紧急停机和火气保护系统的硬件,同时采用Mark VIe ControlST统一软件平台。结果表明:新控制系统采用了一体化硬件、软件设计,提高了机组控制系统的安全可靠性,有利于日常运行维护,而且新系统具有在线监测功能,有助于系统故障排查。
文摘佳能Cinema EOS电影摄影机EOS C500 Mark II日前发布了新固件版本1.1.1.1。经过此次固件升级,EOS C500 Mark II可支持三种新增的Cinema RAW Light记录格式:具有高画质的RAW HQ模式、标准画质的RAW ST模式和精简记录可以延长记录时间的RAW LT模式。
基金King Saud University for funding this work through Researchers Supporting Project number(RSP2022R426).
文摘OpticalMark Recognition(OMR)systems have been studied since 1970.It is widely accepted as a data entry technique.OMR technology is used for surveys and multiple-choice questionnaires.Due to its ease of use,OMR technology has grown in popularity over the past two decades and is widely used in universities and colleges to automatically grade and grade student responses to questionnaires.The accuracy of OMR systems is very important due to the environment inwhich they are used.TheOMRalgorithm relies on pixel projection or Hough transform to determine the exact answer in the document.These techniques rely on majority voting to approximate a predetermined shape.The performance of these systems depends on precise input from dedicated hardware.Printing and scanning OMR tables introduces artifacts that make table processing error-prone.This observation is a fundamental limitation of traditional pixel projection and Hough transform techniques.Depending on the type of artifact introduced,accuracy is affected differently.We classified the types of errors and their frequency according to the artifacts in the OMR system.As a major contribution,we propose an improved algorithm that fixes errors due to skewness.Our proposal is based on the Hough transform for improving the accuracy of bias correction mechanisms in OMR documents.As a minor contribution,our proposal also improves the accuracy of detecting markers in OMR documents.The results show an improvement in accuracy over existing algorithms in each of the identified problems.This improvement increases confidence in OMR document processing and increases efficiency when using automated OMR document processing.
基金supported by National Natural Science Foundation of China (Nos.52207158 and 51821005)the Fundamental Research Funds for the Central Universities (HUST: No.2022JYCXJJ012)the National Key Research and Development Program of China (Nos.2016YFC0401002 and 2016YFC0401006)。
文摘Corona discharge, as a common means to obtain non-equilibrium plasma, can generally obtain high-concentration plasma by increasing discharge points to meet production needs. However,the existing numerical simulation models used to study multi-point corona discharge are all calculations of small-scale space models, which cannot obtain the distribution characteristics of plasma in large space. Based on our previous research, this paper proposes a hybrid model for studying the distribution of multi-point discharge plasma in large-scale spaces, which divides the computational domain and computes separately with the hydrodynamic model and the ion mobility model. The simulation results are verified by a needle–ball electrode device. Firstly, the electric field distribution and plasma distribution of the needle electrodes with single tip and double tips are compared and discussed. Secondly, the plasma distribution of the needle electrode with the double tip at different voltages is investigated. Both computational and experimental results indicate that the charged particle concentration and current of the needle electrode with double tips are both twice as high as those of the needle electrode with a single tip. This model can extend the computational area of the multi-point corona discharge finite element model to the sub-meter(25 cm) or meter level, which provides an effective means to study the plasma distribution generated by multiple discharge points in large-scale space.
文摘Introduction: Endotracheal suction plays a crucial role in the management of mechanically ventilated patients. This study aims to evaluate the clinical effectiveness and safety of suction tubes with markings in mechanically ventilated pediatric patients. Materials and Methods: A randomized assignment was carried out on a cohort of 52 pediatric patients who underwent mechanical ventilation in the Pediatric Intensive Care Unit at the Third Affiliated Hospital of Sun Yat-sen University, covering the period from January 2022 to December 2022. These patients were divided into two groups: an improved group (n = 26) utilizing marked suction tubes, and a regular group (n = 26) employing conventional suction tubes. The objective of our study was to evaluate the clinical effectiveness of marked suction tubes. Results: The effects of the improved group on the vital signs of children undergoing mechanical ventilation were small and statistically significant compared with the regular group (p < 0.05). Additionally, the improved group exhibited a reduced frequency of sputum suction, shorter mechanical ventilation duration, and fewer days of hospitalization in the PICU compared to the regular group during the ventilation period. Notably, the difference in the duration of PICU hospitalization was statistically significant (p < 0.05). Moreover, the incidence of adverse reactions in the improved group was notably lower, with statistically significant differences observed in airway mucous membrane damage and irritating cough when compared to the regular group (p < 0.05). Conclusion: The utilization of marked suction tubes provides clinical nurses with clear guidance for performing suctioning with ease, efficiency and safety. Consequently, advocating for the widespread implementation of marked suction tubes in clinical practice is a commendable pursuit.