期刊文献+
共找到4,465篇文章
< 1 2 224 >
每页显示 20 50 100
Recent advances and innovations in the design and fabrication of wearable flexible biosensors and human health monitoring systems based on conjugated polymers 被引量:1
1
作者 Vinh Van Tran Viet-Duc Phung Daeho Lee 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第4期476-516,共41页
Wearable biosensors have received great interest as patient-friendly diagnostic technologies because of their high flexibility and conformability.The growing research and utilization of novel materials in designing we... Wearable biosensors have received great interest as patient-friendly diagnostic technologies because of their high flexibility and conformability.The growing research and utilization of novel materials in designing wearable biosensors have accelerated the development of point-of-care sensing platforms and implantable biomedical devices in human health care.Among numerous potential materials,conjugated polymers(CPs)are emerging as ideal choices for constructing high-performance wearable biosensors because of their outstanding conductive and mechanical properties.Recently,CPs have been extensively incorporated into various wearable biosensors to monitor a range of target biomolecules.However,fabricating highly reliable CP-based wearable biosensors for practical applications remains a significant challenge,necessitating novel developmental strategies for enhancing the viability of such biosensors.Accordingly,this review aims to provide consolidated scientific evidence by summarizing and evaluating recent studies focused on designing and fabricating CP-based wearable biosensors,thereby facilitating future research.Emphasizing the superior properties and benefits of CPs,this review aims to clarify their potential applicability within this field.Furthermore,the fundamentals and main components of CP-based wearable biosensors and their sensing mechanisms are discussed in detail.The recent advancements in CP nanostructures and hybridizations for improved sensing performance,along with recent innovations in next-generation wearable biosensors are highlighted.CPbased wearable biosensors have been—and will continue to be—an ideal platform for developing effective and user-friendly diagnostic technologies for human health monitoring. 展开更多
关键词 Conjugated polymers Wearable biosensors E-skin electronics Implantable biosensors Conductive polymer hydrogels
下载PDF
Overview of novel nanobiosensors for electrochemical and optical diagnosis of leukemia:Challenge and opportunity
2
作者 Ulya Farahdina Tahta Amrillah +3 位作者 Mashuri Mashuri Vannajan Sanghiran Lee Agus Rubiyanto Nasori Nasori 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第4期116-138,共23页
Leukemia is one of the ten types of cancer that causes the biggest death in the world.Compared to other types of cancer,leukemia has a low life expectancy,so an early diagnosis of the cancer is necessary.A new strateg... Leukemia is one of the ten types of cancer that causes the biggest death in the world.Compared to other types of cancer,leukemia has a low life expectancy,so an early diagnosis of the cancer is necessary.A new strategy has been developed to identify various leukemia biomarkers by making blood cancer biosensors,especially by developing nanomaterial applications so that they can improve the performance of the biosensor.Although many biosensors have been developed,the detection of leukemia by using nanomaterials with electrochemical and optical methods is still less carried out compare to other types of cancer biosensors.Even the acoustic and calorimetric testing methods for the detection of leukemia by utilizing nanomaterials have not yet been carried out.Most of the reviewed works reported the use of gold nanoparticles and electrochemical characterization methods for leukemia detection with the object of study being conventional cancer cells.In order to be used clinically by the community,future research must be carried out with a lot of patient blood objects,develop non-invasive leukemia detection,and be able to detect all types of blood cancer specifically with one biosensor.This can lead to a fast and accurate diagnosis thus allowing for early treatment and easy periodic condition monitoring for various types of leukemia based on its biomarker and future design controlable via internet of things(IoT)so that why would be monitoring real times. 展开更多
关键词 biosensor detection LEUKEMIA NANOMATERIAL IoT
下载PDF
Jamming Assisted Covert Wireless Communication in Multi-Channel Systems
3
作者 Che Bohan Sha Nan +2 位作者 Yang Weiwei Lu Xingbo Gao Chang 《China Communications》 SCIE CSCD 2024年第9期211-224,共14页
This paper investigates the jammerassisted multi-channel covert wireless communication(CWC)by exploiting the randomness of sub-channel selection to confuse the warden.In particular,we propose two sub-channel selection... This paper investigates the jammerassisted multi-channel covert wireless communication(CWC)by exploiting the randomness of sub-channel selection to confuse the warden.In particular,we propose two sub-channel selection transmission schemes,named random sub-channel selection(RSS)scheme and maximum sub-channel selection(MSS)scheme,to enhance communication covertness.For each proposed scheme,we first derive closed-form expressions of the transmission outage probability(TOP),the average effective rate,and the minimum average detection error probability(DEP).Then,the average effective covert rate(ECR)is maximized by jointly optimizing the transmit power at the transmitter and the number of sub-channels.Numerical results show that there is an optimal value of the number of sub-channels that maximizes the average ECR.We also find that to achieve the maximum average ECR,a larger number of subchannels are needed facing a stricter covertness constraint. 展开更多
关键词 covert wireless communication jamming multi-channel system
下载PDF
A Review: Biosensor Progression in Glucose Monitoring for Patients with Diabetes
4
作者 Megan Sweeney 《Advances in Bioscience and Biotechnology》 CAS 2024年第8期503-510,共8页
Diabetes is a condition that can come to the surface at any point throughout a person’s life. Although Type 1 and Type 2 Diabetes have different triggers that cause them to arise, a person can experience similar comp... Diabetes is a condition that can come to the surface at any point throughout a person’s life. Although Type 1 and Type 2 Diabetes have different triggers that cause them to arise, a person can experience similar complications from either if not monitored and treated accordingly. Through the Diabetes Control and Complications Trial, it was found that a significant way to monitor diabetes is through glucose levels in a person’s body. The research surrounding glucose monitoring dates to the mid-1800s, with the first successful reagent for glucose testing being developed in 1908. Since then, glucose sensing has become one of the most rapidly growing areas of research and development in biosensor technology, creating a competitive market for more advanced, accurate, and convenient glucose monitoring. This article reviews the history of biosensors used for glucose monitoring, and major advancements in biosensor technology to enhance performance and improve quality of life for patients with diabetes. 展开更多
关键词 biosensor Continuous Glucose Monitor SMBG Advances in Glucose Monitoring DIABETES
下载PDF
Nanomaterial-assisted wearable glucose biosensors for noninvasive real-time monitoring:Pioneering point-of-care and beyond
5
作者 Moein Safarkhani Abdullah Aldhaher +5 位作者 Golnaz Heidari Ehsan Nazarzadeh Zare Majid Ebrahimi Warkiani Omid Akhavan YunSuk Huh Navid Rabiee 《Nano Materials Science》 EI CAS CSCD 2024年第3期263-283,共21页
This review explores glucose monitoring and management strategies,emphasizing the need for reliable and userfriendly wearable sensors that are the next generation of sensors for continuous glucose detection.In additio... This review explores glucose monitoring and management strategies,emphasizing the need for reliable and userfriendly wearable sensors that are the next generation of sensors for continuous glucose detection.In addition,examines key strategies for designing glucose sensors that are multi-functional,reliable,and cost-effective in a variety of contexts.The unique features of effective diabetes management technology are highlighted,with a focus on using nano/biosensor devices that can quickly and accurately detect glucose levels in the blood,improving patient treatment and control of potential diabetes-related infections.The potential of next-generation wearable and touch-sensitive nano biomedical sensor engineering designs for providing full control in assessing implantable,continuous glucose monitoring is also explored.The challenges of standardizing drug or insulin delivery doses,low-cost,real-time detection of increased blood sugar levels in diabetics,and early digital health awareness controls for the adverse effects of injectable medication are identified as unmet needs.Also,the market for biosensors is expected to expand significantly due to the rising need for portable diagnostic equipment and an ever-increasing diabetic population.The paper concludes by emphasizing the need for further research and development of glucose biosensors to meet the stringent requirements for sensitivity and specificity imposed by clinical diagnostics while being cost-effective,stable,and durable. 展开更多
关键词 Glucose sensor biosensor Wearable devices NONINVASIVE Real-time monitoring
下载PDF
A novel multi-channel porous structure facilitating mass transport towards highly efficient alkaline water electrolysis
6
作者 Xinge Jiang Vasileios Kyriakou +6 位作者 Chen Song Xianbin Wang Sophie Costil Chunming Deng Taikai Liu Tao Jiang Hanlin Liao 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第6期511-518,I0013,共9页
An advantageous porous architecture of electrodes is pivotal in significantly enhancing alkaline water electrolysis(AWE)efficiency by optimizing the mass transport mechanisms.This effect becomes even more pronounced w... An advantageous porous architecture of electrodes is pivotal in significantly enhancing alkaline water electrolysis(AWE)efficiency by optimizing the mass transport mechanisms.This effect becomes even more pronounced when aiming to achieve elevated current densities.Herein,we employed a rapid and scalable laser texturing process to craft novel multi-channel porous electrodes.Particularly,the obtained electrodes exhibit the lowest Tafel slope of 79 mV dec^(-1)(HER)and 49 mV dec^(-1)(OER).As anticipated,the alkaline electrolyzer(AEL)cell incorporating multi-channel porous electrodes(NP-LT30)exhibited a remarkable improvement in cell efficiency,with voltage drops(from 2.28 to 1.97 V)exceeding 300 mV under 1 A cm^(-1),compared to conventional perforated Ni plate electrodes.This enhancement mainly stemmed from the employed multi-channel porous structure,facilitating mass transport and bubble dynamics through an innovative convection mode,surpassing the traditional convection mode.Furthermore,the NP-LT30-based AEL cell demonstrated exceptional durability for 300 h under 1.0 A cm^(-2).This study underscores the capability of the novel multi-channel porous electrodes to expedite mass transport in practical AWE applications. 展开更多
关键词 Alkaline water electrolysis Mass transport Bubble dynamics Innovative convection mode multi-channel porous structure
下载PDF
Novel Sustainable Cellulose Acetate Based Biosensor for Glucose Detection
7
作者 M.F.Elkady E.M.El-Sayed +2 位作者 Mahmoud Samy Omneya A.Koriem H.Shokry Hassan 《Journal of Renewable Materials》 EI CAS 2024年第2期369-380,共12页
In this study,green zinc oxide(ZnO)/polypyrrole(Ppy)/cellulose acetate(CA)film has been synthesized via solvent casting.This film was used as supporting material for glucose oxidase(GOx)to sensitize a glucose biosenso... In this study,green zinc oxide(ZnO)/polypyrrole(Ppy)/cellulose acetate(CA)film has been synthesized via solvent casting.This film was used as supporting material for glucose oxidase(GOx)to sensitize a glucose biosensor.ZnO nanoparticles have been prepared via the green route using olive leaves extract as a reductant.ZnO/Ppy nanocomposite has been synthesized by a simple in-situ chemical oxidative polymerization of pyrrole(Py)monomer using ferric chloride(FeCl3)as an oxidizing agent.The produced materials and the composite films were characterized using X-ray diffraction analysis(XRD),scanning electron microscope(SEM),Fourier transform infrared(FTIR)and thermogravimetric analysis(TGA).Glucose oxidase was successfully immobilized on the surface of the prepared film and then ZnO/Ppy/CA/GOx composite was sputtered with platinum electrode for the current determination at different initial concentrations of glucose.Current measurements proved the suitability and the high sensitivity of the constructed biosensor for the detection of glucose levels in different samples.The performance of the prepared biosensor has been assessed by measuring and comparing glucose concentrations up to 800 ppm.The results affirmed the reliability of the developed biosensor towards real samples which suggests the wide-scale application of the proposed biosensor. 展开更多
关键词 biosensors composite films GLUCOSE POLYPYRROLE green ZnO cellulose acetate
下载PDF
The biofilm characteristics and enhanced performance of a marine microbial-electrolysis-cell-based biosensor under positive anodic potential
8
作者 CAO Yuanyuan ZHANG Chaoqun +2 位作者 LIU Xiang CHENG Liang YANG Yang 《土木与环境工程学报(中英文)》 CSCD 北大核心 2024年第6期221-230,共10页
Microbial fuel cells have already been used as biosensors to monitor assimilable organic carbon(AOC).However,their signal production from AOC is known to be completely suppressed by dissoved oxygen(DO).In this study,t... Microbial fuel cells have already been used as biosensors to monitor assimilable organic carbon(AOC).However,their signal production from AOC is known to be completely suppressed by dissoved oxygen(DO).In this study,two identical microbial electrolysis cell(MEC)based biosensors were inoculated with marine sediment and operated at two different anodic potentials,namely-300 mV and+250 mV relative to Ag/AgCl.The MEC biosensor operated under positive anodic potential conditions had electrochemically active microbial communities on the anode,including members of the Shewanellaceae,Pseudoalteromonadaceae,and Clostridiaceae families.However,the strictly anaerobic members of the Desulfuromonadaceae,Desulfobulbaceae and Desulfobacteraceae families were found only in the negative anodic potential MEC biosensor.The positive anodic potential MEC biosensor showed several other advantages as well,such as faster start-up,significantly higher maximum current production,fivefold improvement in the AOC detection limit,and tolerance of low dissolved oxygen,compared to those obtained from the negative anodic potential MEC biosensor.The developed positive anodic potential MEC biosensor can thus be used as a real-time and inexpensive detector of AOC concentrations in high saline and low DO seawater. 展开更多
关键词 biosensor microbial fuel cell anodic potential marine biofilm assimilable organic carbon
下载PDF
Construction of Electrochemical Biosensors Based on the CRISPR/Cas12 System for Applications
9
作者 Hongqu Liang Liu Huang +3 位作者 Peng Yan Fa Huang Hongchao Zhang Qisheng Luo 《Materials Sciences and Applications》 2024年第9期285-304,共20页
The current major issue in improving detection sensitivity and selectivity is to design an electrochemical sensor that does not require PCR amplification for nucleic acid identification and measurement. Because of the... The current major issue in improving detection sensitivity and selectivity is to design an electrochemical sensor that does not require PCR amplification for nucleic acid identification and measurement. Because of their great sensitivity, precision, and simplicity of downsizing, electrochemical biosensors have emerged as a research hotspot in the field of nucleic acid detection. The CRISPR/Cas12 system has emerged as a potent tool for nucleic acid detection due to its powerful cleavage activity and selectivity. Specific electrode changes combined with the CRISPR/Cas12 system can greatly improve the performance of electrochemical biosensors. In this study, the design concepts of electrochemical biosensors based on the CRISPR/Cas12 system and their application advancements in nucleic acid detection are discussed. 展开更多
关键词 CRISPR Cas12 Electrochemical biosensor
下载PDF
Development of ratiometric DNA biosensors with improved accuracy,precision,and signal-to-noise ratio
10
作者 Qing Tao Yanli Wen +9 位作者 Wen Liang Lele Wang Ruiyan Guo Min Ding Ming Luo Juan Yan Feiyan Gong Chengming Cao Lanying Li Gang Liu 《Advanced Sensor and Energy Materials》 2024年第3期11-22,共12页
Ratiometric DNA biosensors,which utilize DNA as the recognition element and integrate dual signals from diverse sensing platforms including fluorescence,electrochemistry,and surface-enhanced Raman scattering(SERS),hav... Ratiometric DNA biosensors,which utilize DNA as the recognition element and integrate dual signals from diverse sensing platforms including fluorescence,electrochemistry,and surface-enhanced Raman scattering(SERS),have demonstrated remarkable proficiency in detecting a wide range of targets.In this review,we showcase the significant progress achieved by ratiometric biosensors.Firstly,ratiometric biosensors have made notable advancements in analyzing real samples.These include the analysis of pH values near cancer cells,quantification of miRNA in human cell lysates,detection of human telomerase RNA in cell extracts,and performing DNA logicgated in situ bioimaging on cell membranes.Secondly,excellent sensitivity has been attained through the utilization of effective amplification methods such as RCA,HCR,and CHA,among others.Thirdly,the construction of stable reference signals has resulted in significantly improved precision for ratiometric biosensors.This breakthrough has overcome matrix effects,enabling reliable detection in real samples with high selectivity.This review provides a comprehensive overview of recent advancements in strategies employed by ratiometric DNA biosensors.We present three types of biosensors based on distinct sensing platforms:fluorescent,electrochemical,and SERS biosensors.Additionally,we discuss future directions and primary challenges in the development of ratiometric DNA biosensors. 展开更多
关键词 Ratiometric biosensor DNA NANOMATERIALS Fluorescent biosensor Electrochemical biosensor SERS biosensor
下载PDF
Design of Cold-Junction Compensation and Disconnection Detection Circuits of Various Thermocouples and Implementation of Multi-Channel Interfaces Using Them-A Secondary Publication
11
作者 Hyeong-Woo Cha 《Journal of Electronic Research and Application》 2024年第1期93-105,共13页
Cold-junction compensation(CJC)and disconnection detection circuit design of various thermocouples(TC)and multi-channel TC interface circuits were designed.The CJC and disconnection detection circuit consists of a CJC... Cold-junction compensation(CJC)and disconnection detection circuit design of various thermocouples(TC)and multi-channel TC interface circuits were designed.The CJC and disconnection detection circuit consists of a CJC semiconductor device,an instrumentation amplifier(IA),two resistors,and a diode for disconnection detection.Based on the basic circuit,a multi-channel interface circuit was also implemented.The CJC was implemented using compensation semiconductor and IA,and disconnection detection was detected by using two resistors and a diode so that IA input voltage became-0.42 V.As a result of the experiment using R-type TC,the error of the designed circuit was reduced from 0.14 mV to 3μV after CJC in the temperature range of 0°C to 1400°C.In addition,it was confirmed that the output voltage of IA was saturated from 88 mV to-14.2 V when TC was disconnected from normal.The output voltage of the designed circuit was 0 V to 10 V in the temperature range of 0°C to 1400°C.The results of the 4-channel interface experiment using R-type TC were almost identical to the CJC and disconnection detection results for each channel.The implemented multi-channel interface has a feature that can be applied equally to E,J,K,T,R,and S-type TCs by changing the terminals of CJC semiconductor devices and adjusting the IA gain. 展开更多
关键词 R-type thermocouple(TC) Cold-junction compensation(CJC) TC disconnection detection multi-channel interface circuit Sensor interface
下载PDF
Development of multi-channel observation and inversion for IP electrical sounding method 被引量:5
12
作者 刘海飞 柳建新 +3 位作者 郭荣文 童孝忠 龚露 彭艳华 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2014年第3期816-823,共8页
In order to improve the exploration effect of deep non-ferrous mineral resources, multi-channel observation methods for induced polarization (IP) electrical sounding data and their inversion imaging technology are s... In order to improve the exploration effect of deep non-ferrous mineral resources, multi-channel observation methods for induced polarization (IP) electrical sounding data and their inversion imaging technology are studied. First of all, four multi-channel observation methods are developed based on conventional IP electrical method, namely three-electrode and four-electrode arrays of unilateral and bilateral current transmitting. Then the maximum smoothness constrained inversion method of the least squares sense for IP electrical sounding data is proposed, and the inversion software is programmed. Finally, the simulation and inversion results of geo-electrical model for the proposed observation methods are analyzed. And the comparison results show that three-electrode array of bilateral current transmitting gives the best result, but the intensity in field work is larger than others; unilateral three-electrode and four-electrode arrays give the better results. Taking detection results and convenience of field exploration work into consideration, these two methods are more suitable for practical application; bilateral observation method of four-electrode array is not suitable for the detection of the steep ore bodies. 展开更多
关键词 IP electrica-1 sounding multi-channel observation deep exploration inversion imaging
下载PDF
Design of multi-channel data acquisition system based on LabVIEW and NI PXI-5105 被引量:4
13
作者 解亚妮 张志杰 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2015年第1期7-12,共6页
A data acquisition system based on LabVIEW and NI PXI-5105 is presented for multi-channel data acquisition. It can realize the functions of parameter setting, data acquisition and storage, waveform display and data an... A data acquisition system based on LabVIEW and NI PXI-5105 is presented for multi-channel data acquisition. It can realize the functions of parameter setting, data acquisition and storage, waveform display and data analysis using LabVIEW and NI-SCOPE device driver. The advantages of the system are that the setting is convenient, the operation is easy, the interface is friendly and the functions are practical. The experiment results show that the system has good stability and high reliability and is a powerful tool for multi-channel data acquisition. 展开更多
关键词 LABVIEW multi-channel data acquisition PXI-5105
下载PDF
Flexible Graphene Field‑Effect Transistors and Their Application in Flexible Biomedical Sensing
14
作者 Mingyuan Sun Shuai Wang +5 位作者 Yanbo Liang Chao Wang Yunhong Zhang Hong Liu Yu Zhang Lin Han 《Nano-Micro Letters》 SCIE EI CAS 2025年第2期252-313,共62页
Flexible electronics are transforming our lives by making daily activities more convenient.Central to this innovation are field-effect transistors(FETs),valued for their efficient signal processing,nanoscale fabricati... Flexible electronics are transforming our lives by making daily activities more convenient.Central to this innovation are field-effect transistors(FETs),valued for their efficient signal processing,nanoscale fabrication,low-power consumption,fast response times,and versatility.Graphene,known for its exceptional mechanical properties,high electron mobility,and biocompatibility,is an ideal material for FET channels and sensors.The combination of graphene and FETs has given rise to flexible graphene field-effect transistors(FGFETs),driving significant advances in flexible electronics and sparked a strong interest in flexible biomedical sensors.Here,we first provide a brief overview of the basic structure,operating mechanism,and evaluation parameters of FGFETs,and delve into their material selection and patterning techniques.The ability of FGFETs to sense strains and biomolecular charges opens up diverse application possibilities.We specifically analyze the latest strategies for integrating FGFETs into wearable and implantable flexible biomedical sensors,focusing on the key aspects of constructing high-quality flexible biomedical sensors.Finally,we discuss the current challenges and prospects of FGFETs and their applications in biomedical sensors.This review will provide valuable insights and inspiration for ongoing research to improve the quality of FGFETs and broaden their application prospects in flexible biomedical sensing. 展开更多
关键词 FLEXIBLE GRAPHENE Field-effect transistor Wearable IMPLANTABLE biosensor
下载PDF
A maximum-independent-set-based channel allocation algorithm for multi-channel wireless networks
15
作者 余旭涛 施小翔 曾绍祥 《Journal of Southeast University(English Edition)》 EI CAS 2015年第1期12-18,共7页
A channel allocation algorithm based on the maximum independent set is proposed to decrease network conflict and improve network performance. First, a channel allocation model is formulated and a series of the maximum... A channel allocation algorithm based on the maximum independent set is proposed to decrease network conflict and improve network performance. First, a channel allocation model is formulated and a series of the maximum independent sets (MISs) are obtained from a contention graph by the proposed approximation algorithm with low complexity. Then, a weighted contention graph is obtained using the number of contention vertices between two MISs as a weighted value. Links are allocated to channels by the weighted contention graph to minimize conflicts between independent sets. Finally, after channel allocation, each node allocates network interface cards (NICs) to links that are allocated channels according to the queue lengths of NICs. Simulations are conducted to evaluate the proposed algorithm. The results show that the proposed algorithm significantly improves the network throughput and decreases the end to end delay. 展开更多
关键词 wireless networks multi-channel channelaUocation maximum independent set
下载PDF
Advancing healthcare through laboratory on a chip technology:Transforming microorganism identification and diagnostics
16
作者 Carlos M Ardila 《World Journal of Clinical Cases》 SCIE 2025年第3期9-19,共11页
In a recent case report in the World Journal of Clinical Cases,emphasized the crucial role of rapidly and accurately identifying pathogens to optimize patient treatment outcomes.Laboratory-on-a-chip(LOC)technology has... In a recent case report in the World Journal of Clinical Cases,emphasized the crucial role of rapidly and accurately identifying pathogens to optimize patient treatment outcomes.Laboratory-on-a-chip(LOC)technology has emerged as a transformative tool in health care,offering rapid,sensitive,and specific identification of microorganisms.This editorial provides a comprehensive overview of LOC technology,highlighting its principles,advantages,applications,challenges,and future directions.Success studies from the field have demonstrated the practical benefits of LOC devices in clinical diagnostics,epidemiology,and food safety.Comparative studies have underscored the superiority of LOC technology over traditional methods,showcasing improvements in speed,accuracy,and portability.The future integration of LOC with biosensors,artificial intelligence,and data analytics promises further innovation and expansion.This call to action emphasizes the importance of continued research,investment,and adoption to realize the full potential of LOC technology in improving healthcare outcomes worldwide. 展开更多
关键词 Laboratory-on-a-chip Microorganism identification DIAGNOSTICS Point-ofcare testing biosensors
下载PDF
Mushroom Pulp Tissue-Based Membrane-Ferrocene-Modified L-Tyrosine Biosensor
17
作者 马全红 邓家祺 《Journal of Southeast University(English Edition)》 EI CAS 2000年第1期106-110,共5页
A new approach for assembling amperometric mushroom pulp tissue based membrane electrode for determination of L tyrosine analysis is proposed. Ferrocene is used as a mediator of electron transfer between tyrosinase ... A new approach for assembling amperometric mushroom pulp tissue based membrane electrode for determination of L tyrosine analysis is proposed. Ferrocene is used as a mediator of electron transfer between tyrosinase in mushroom tissue and a graphite electrode. The optimal operation conditions are studied. The linear response range of the biosensor is 2 0×10 -4 to 4 5×10 -3 mol·L -1 with response time of less than 5 min and lifetime of at least 30 d. The biosensor can be applied to practical sample analysis. 展开更多
关键词 biosensor tissue based membrane electrode modified electrode FERROCENE L tyrosine
下载PDF
基于Multi-Radio Multi-Channel传感器网络无冲突信道分配算法的研究 被引量:2
18
作者 蔡凤丽 刘新永 《吉林工程技术师范学院学报》 2014年第5期95-96,共2页
为降低通信冲突和信道干扰,对Mult-i Radio Mult-i Channel传感器网络无冲突信道进行研究,结果证实在网络通信半径大于3倍的网络最大功率通信半径的前提下,Sensor节点规模满足2倍网络功率级数加1的环境下,网络无冲突信道分配的信道数达... 为降低通信冲突和信道干扰,对Mult-i Radio Mult-i Channel传感器网络无冲突信道进行研究,结果证实在网络通信半径大于3倍的网络最大功率通信半径的前提下,Sensor节点规模满足2倍网络功率级数加1的环境下,网络无冲突信道分配的信道数达到网络信道冲突图的最大值。文章通过对无冲突信道算法的运用,最终证实其可以有效地提高传感器网络的工作效率,大幅度提升网络的吞吐量。 展开更多
关键词 MULTI-RADIO multi-channel 传感器网络 无冲突信道信道分配
下载PDF
Toxicity assessment of heavy metals and organic compounds using CellSense biosensor with E.coli 被引量:15
19
作者 Hong Wang Xue Jiang Wang Jian Fu Zhao Ling Chen 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第2期211-214,共4页
A new strategy using an arnperometric biosensor with Escherichia coli (E. coli) that provides a rapid toxicity determination of chemical compounds is described. The CellSense biosensor system comprises a biological ... A new strategy using an arnperometric biosensor with Escherichia coli (E. coli) that provides a rapid toxicity determination of chemical compounds is described. The CellSense biosensor system comprises a biological component immobilized in intimate contact with a transducer which converts the biochemical signal into a quantifiable electrical signal. Toxicity assessment of heavy metals using E.coli biosensors could be finished within 30 min and the 50% effective concentrations (ECso) values of four heavy metals were determined. The results shows that inhibitory effects of four heavy metals to E.coli can be ranked in a decreasing order of Hg^2+ 〉 Cu^2+ 〉 Zn^2+ 〉 Ni^2+, which accords to the results of conventional bacterial counting method. The toxicity test of organic compounds by using CellSense biosensor was also demonstrated. The CellSense biosensor with E. coli shows a good, reproducible behavior and can be used for reproducible measurements. 展开更多
关键词 Whole-cell biosensor Heavy metal Organic compounds TOXICITY
下载PDF
Using a Surface Plasmon Resonance Biosensor for Rapid Detection of Salmonella Typhimurium in Chicken Carcass 被引量:18
20
作者 Yu-bin Lan Shi-zhou Wang +2 位作者 Yong-guang Yin W. Clint Hoffmann Xian-zhe Zheng 《Journal of Bionic Engineering》 SCIE EI CSCD 2008年第3期239-246,共8页
Chicken is one of the most popular meat products in the world. Salmonella Typhimurium is a common foodbome pathogens associated with the processing of poultry. An optical Surface Plasmon Resonance (SPR) biosensor wa... Chicken is one of the most popular meat products in the world. Salmonella Typhimurium is a common foodbome pathogens associated with the processing of poultry. An optical Surface Plasmon Resonance (SPR) biosensor was sensitive to the presence of Salmonella Typhimurium in chicken carcass. The Spreeta biosensor kits were used to detect Salmonella Typhimurium on chicken carcass successfully. A taste sensor like electronic tongue or biosensors was used to basically "taste" the object and differentiated one object from the other with different taste sensor signatures. The surface plasmon resonance biosensor has potential for use in rapid, real-time detection and identification of bacteria, and to study the interaction of organisms with dif- ferent antisera or other molecular species. The selectivity of the SPR biosensor was assayed using a series of antibody con- centrations and dilution series of the organism. The SPR biosensor showed promising to detect the existence of Salmonella Typhimurium at 1 x 106 CFU/ml. Initial results show that the SPR biosensor has the potential for its application in pathogenic bacteria monitoring. However, more tests need to be done to confirm the detection limitation. 展开更多
关键词 biosensor Salmonella Typhimurium food safety chicken carcass detection limitation Surface Plasmon Resonance
下载PDF
上一页 1 2 224 下一页 到第
使用帮助 返回顶部