期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Computed tomography diagnosed left ovarian venous thrombophlebitis after vaginal delivery:A case report
1
作者 Jin-Jin Wang Chu-Chu Hui +1 位作者 Yi-Ding Ji Wei Xu 《World Journal of Clinical Cases》 SCIE 2023年第4期896-902,共7页
BACKGROUND Postpartum ovarian vein thrombophlebitis(POVT)is a rare but serious postpartum complication that affects mostly postpartum women.A high index of suspicion is required when faced with sudden postpartum abdom... BACKGROUND Postpartum ovarian vein thrombophlebitis(POVT)is a rare but serious postpartum complication that affects mostly postpartum women.A high index of suspicion is required when faced with sudden postpartum abdominal pain.CASE SUMMARY A 25-year-old healthy woman who accepted a vaginal delivery procedure suffered fever(temperature 39.6℃)one day after delivery,accompanied with left lower abdominal pain.Physical examination indicated mild tenderness in the left lower abdomen,accompanied with rebound pain.The patient was confirmed to have left ovarian venous thrombosis with inflammation after receiving a multidetector row computed tomography scan.CONCLUSION POVT is a rare and dangerous postpartum complication.A high index of suspicion is required for the occurrence of ovarian venous thrombosis when faced with postpartum abdominal pain and fever.Early application of Doppler ultrasound,computed tomography,magnetic resonance imaging and other auxiliary examinations is conducive to timely and accurate diagnosis of POVT,thus reducing maternal mortality. 展开更多
关键词 Ovarian venous thrombosis POSTPARTUM multi-detector row computed tomography Case report
下载PDF
A spontaneous strangulated transomental hernia: Prospective and retrospective multi-detector computed tomography findings
2
作者 Luigi Camera Angela De Gennaro +5 位作者 Margaret Longobardi Stefania Masone Emanuela Calabrese Walter Del Vecchio Giovanni Persico Marco Salvatore 《World Journal of Radiology》 CAS 2014年第2期26-30,共5页
Transomental hernias are among the rarest type of all internal hernias which overall account for less than 6% of small bowel obstructions. Most transomental hernias occurring in adults are either iatrogenic or post-tr... Transomental hernias are among the rarest type of all internal hernias which overall account for less than 6% of small bowel obstructions. Most transomental hernias occurring in adults are either iatrogenic or post-traumatic. More rarely, a spontaneous herniation of small bowel loops may result from senile atrophy of the omentum. We report a case of an 86-year-old male who presented with signs and symptoms of small bowel obstruction but had no past surgical or traumatic abdominal history. At contrast-enhanced multi-detector row computed tomography(CT), a cluster of fluid-filled dilated small bowel loops could be appreciated in the left flank, with associated signs of bowel wall ischemia. Swirling of the mesenteric vessels could also be appreciated and CT findings were prospectively considered consistent with a strangulated small bowel volvulus. At laparotomy, no derotation had to be performed but up to 100 cm of gangrenous small bowel loops had to be resected because of a transomental hernia through a small defect in the left part of the greater omentum. Retrospective reading of CT images was performed and findings suggestive of transomental herniation could then be appreciated. 展开更多
关键词 Small BOWEL OBSTRUCTION Internal HERNIAS Transomental HERNIA multi-detector row computed tomography STRANGULATION
下载PDF
Current status of low dose multi-detector CT in the urinary tract 被引量:4
3
作者 Mi Kim Sung Sarabjeet Singh Mannudeep K Kalra 《World Journal of Radiology》 CAS 2011年第11期256-265,共10页
Over the past several years,advances in the technical domain of computed tomography(CT) have influenced the trend of imaging modalities used in the clinical evaluation of the urinary system.Renal collecting systems ca... Over the past several years,advances in the technical domain of computed tomography(CT) have influenced the trend of imaging modalities used in the clinical evaluation of the urinary system.Renal collecting systems can be illustrated more precisely with the advent of multi-detector row CT through thinner slices,high speed acquisitions,and enhanced longitudinal spatial resolution resulting in improved reformatted coronal images.On the other hand,a significant increase in exposure to ionizing radiation,especially in the radiosensitive organs,such as the gonads,is a concern with the increased utilization of urinary tract CT.In this article,we discuss the strategies and techniques availablefor reducing radiation dose for a variety of urinary tractCT protocols with metabolic clinical examples.We also reviewed CT for hematuria evaluation and related scan parameter optimization such as,reducing the number of acquisition phases,CT angiography of renal donors and lowering tube potential,when possible. 展开更多
关键词 HEMATURIA evaluation Low dose computedTOMOGRAPHY multi-detector row computed TOMOGRAPHY Renal donor computed TOMOGRAPHY angiography Urinary TRACT imaging
下载PDF
Utility of multi-detector row computed tomography angiography versus Doppler in localization of perforators of anterolateral thigh flaps
4
作者 Chandan N.Jadhav Surinder Singh Makkar +1 位作者 Gautam Biswas Niranjan Khandelwal 《Plastic and Aesthetic Research》 2016年第1期52-58,共7页
Aim:Anterolateral thigh(ALT)flap is widely used in reconstruction of various defects.Preoperative imaging facilitates perforator mapping,overcoming intraoperative uncertainty.The purpose of this study was to investiga... Aim:Anterolateral thigh(ALT)flap is widely used in reconstruction of various defects.Preoperative imaging facilitates perforator mapping,overcoming intraoperative uncertainty.The purpose of this study was to investigate the utility of multi-detector row computed tomography angiography(MDCTA)and a handheld Doppler in locating ALT perforators.Methods:Twenty patients were randomized into two groups.Group 1 patients received MDCTA and Doppler studies whereas Group 2 received only a Doppler study.The number,location,course,and source of all cutaneous and sizable perforators were compared with intraoperative findings.Surgeons’stress levels during flap harvest and flap harvest time were compared.Results:MDCTA findings correlated well with intraoperative findings for perforator type and segmental distribution with 100%concordance.Doppler alone had a 52%rate of concordance.The sensitivity and specificity for MDCTA in demonstrating the presence of perforators were 85.71%and 97.22%,respectively;whereas for Doppler alone the sensitivity and specificity were 80%and 87.91%,respectively.In demonstrating perforator source,MDCTA showed a sensitivity of 100%and specificity of 91.66%,with 100%accuracy.Sensitivity and specificity for sizable perforators were 90%each,with 88.88%accuracy.Doppler studies were unable to provide this information.Comparison of surgeon stress levels showed no differences between the two groups,although the time for flap harvest was significantly shorter in Group 1.Conclusion:MDCTA compared to Doppler is more sensitive,specific,and accurate with respect to location,course,and source of perforators. 展开更多
关键词 Anterolateral thigh multi-detector row computed tomography angiography PERFORATOR
原文传递
追加注射生理盐水对提高多层螺旋CT尿路造影显影率的评价 被引量:5
5
作者 高洁冰 章作铨 +3 位作者 赵虹 张翠运 秦培鑫 何燕丽 《中国实用医药》 2008年第27期3-4,共2页
目的探讨在多层螺旋CT尿路造影中注射造影剂后追加滴注生理盐水对提高显影率的价值。方法对36例行泌尿系统多层螺旋CT检查的病例,分别在注射造影剂后追加滴注和不追加生理盐水,对追加和不追加生理盐水的图像进行对照分析。结果生理盐水... 目的探讨在多层螺旋CT尿路造影中注射造影剂后追加滴注生理盐水对提高显影率的价值。方法对36例行泌尿系统多层螺旋CT检查的病例,分别在注射造影剂后追加滴注和不追加生理盐水,对追加和不追加生理盐水的图像进行对照分析。结果生理盐水组和对照组的双侧的中段及下段输尿管平均分值生理盐水组明显高于对照组,有统计学意义。结论在注射造影剂后追加注射生理盐水能显著改善多层螺旋CT尿路造影中肾内集合系统和输尿管的显影,是提高多层螺旋CT尿路造影显影质量的有效方法。 展开更多
关键词 多层螺旋CT 尿路造影 生理盐水
下载PDF
MDCT angiography to evaluate the therapeutic effect of PTVE for esophageal varices 被引量:13
6
作者 Aitao Sun Yong-Jun Shi +4 位作者 Zhuo-Dong Xu Xiang-Guo Tian Jin-Hua Hu Guang-Chuan Wang Chun-Qing Zhang 《World Journal of Gastroenterology》 SCIE CAS 2013年第10期1563-1571,共9页
Abstract AIM:To evaluate the role of multi-detector row computed tomography(MDCT) angiography for assessing the therapeutic effects of percutaneous transhepatic variceal embolization(PTVE) for esophageal varices(EVs).... Abstract AIM:To evaluate the role of multi-detector row computed tomography(MDCT) angiography for assessing the therapeutic effects of percutaneous transhepatic variceal embolization(PTVE) for esophageal varices(EVs).METHODS:The subjects of this prospective study were 156 patients who underwent PTVE with cyanoacrylate for EVs.Patients were divided into three groups according to the filling range of cyanoacrylate in EVs and their feeding vessels:(1) group A,complete obliteration,with at least 3 cm of the lower EVs and peri-/EVs,as well as the adventitial plexus of the gastric cardia and fundus filled with cyanoacrylate;(2) group B,partial obliteration of varices surrounding the gastric cardia and fundus,with their feeding vessels being obliterated with cyanoacrylate,but without reaching lower EVs;and(3) group C,trunk obliteration,with the main branch of the left gastric vein being filled with cyanoacrylate,but without reaching varices surrounding the gastric cardia or fundus.We performed chart reviews and a prospective follow-up using MDCT images,angiography,and gastrointestinal endoscopy.RESULTS:The median follow-up period was 34 mo.The rate of eradication of varices for all patients was 56.4%(88/156) and the rate of relapse was 31.3%(41/131).The rates of variceal eradication at 1,3,and 5 years after PTVE were 90.2%,84.1% and 81.7%,respectively,for the complete group;61.2%,49% and 42.9%,respectively,for the partial group;with no varices disappearing in the trunk group.The relapsefree rates at 1,3 and 5 years after PTVE were 91.5%,86.6% and 81.7%,respectively,for the complete group;71.1%,55.6% and 51.1%,respectively,for the partial group;and all EVs recurred in the trunk group.Kaplan-Meier analysis showed P values of 0.000 and 0.000,and odds ratios of 3.824 and 3.603 for the rates of variceal eradication and relapse free rates,respectively.Cyanoacrylate in EVs disappeared with time,but those in the EVs and other feeding vessels remained permanently in the vessels without a decrease with time,which is important for the continued obliteration of the feeding vessels and prevention of EV relapse.CONCLUSION:MDCT provides excellent visualization of cyanoacrylate obliteration in EV and their feeding veins after PTVE.It confirms that PTVE is effective for treating EVs. 展开更多
关键词 multi-detector row computed tomography PERCUTANEOUS TRANSHEPATIC variceal EMBOLIZATION CYANOACRYLATE Esophageal VARICES Therapeutic effect
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部