China’s unconventional gas fields have a large number of low-productivity and low-efficiency wells, many of whichare located in remote and environmentally harsh mountainous areas. To address the long-term stable prod...China’s unconventional gas fields have a large number of low-productivity and low-efficiency wells, many of whichare located in remote and environmentally harsh mountainous areas. To address the long-term stable productionof these gas wells, plunger-lift technology plays an important role. In order to fully understand and accurately graspthe drainage and gas production mechanisms of plunger-lift, a mechanical model of plunger-liquid column uplift inthe plunger-lift process was established, focusing on conventional plunger-lift systems and representative wellboreconfigurations in the Linxing region. The operating casing pressure of the plunger-lift process and the calculationmethod for the maximum daily fluid production rate based on the work regime with the highest fluid recovery ratewere determined. For the first time, the critical flow rate method was proposed as a constraint for the maximumliquid-carrying capacity of the plunger-lift, and liquid-carrying capacity charts for conventional plunger-lift withdifferent casing sizes were developed. The results showed that for 23/8 casing plunger-lift, with a well depth ofshallower than 808 m, the maximum drainage rate was 33 m3/d;for 27/8 casing plunger-lift, with a well depth ofshallower than 742 m, the maximum drainage rate was 50.15 m3/d;for 31/2 casing plunger-lift, with a well depthof shallower than 560 m, the maximum drainage rate was 75.14 m3/d. This research provides a foundation for thescientific selection of plunger-lift technology and serves as a decision-making reference for developing reasonableplunger-lift work regimes.展开更多
Summary: We performed a retrospective, case-control study to evaluate whether the urine flow acceleration (UFA, mL/s2) is superior to maximum uroflow (Qmax, mL/s) in diagnosing bladder outlet obstruction (BOO) ...Summary: We performed a retrospective, case-control study to evaluate whether the urine flow acceleration (UFA, mL/s2) is superior to maximum uroflow (Qmax, mL/s) in diagnosing bladder outlet obstruction (BOO) in patients with benign prostatic hyperplasia (BPH). In this study, a total of 50 men with BPH (age: 58±12.5 years) and 50 controls (age: 59±13.0 years) were included. A pressure-flow study was used to determine the presence of BOO according to the recommendations of Incontinence Control Society (ICS). The results showed that the UFA and Qmax in BPH group were much lower than those in the control group [(2.05±0.85) vs. (4.60±1.25) mL/s2 and (8.50±1.05) vs. (13.00±3.35) mL/s] (P〈0.001). Accol;ding to the criteria (UFA〈2.05 mL/s2, Qmax〈10 mL/s), the sensitivity and specificity of UFA vs. Qmax in diagnosing BOO were 88%, 75% vs. 81%, 63%. UFA vs. Omax, when compared with the results of P-Q chart (the kappa values in corresponding analysis), was 0.55 vs. 0.35. The pros- tate volume, post void residual and detrusor pressure at Qmax between the two groups were 28.6±9.8 vs. 24.2±7.6 mL, 60.4±1.4 vs. 21.3±2.5 mL and 56.6±8.3 vs. 21.7±6.1 cmHzO, respectively (P〈0.05). It was concluded that the UFA is a useful urodynamic parameter, and is superior to Qmax in diagnosing BOO in patients with BPH.展开更多
A dynamic transient flow analysis method considering complex factors such as the cyclic injection and production history in a gas field storage facility was established in view of the limitations of the existing metho...A dynamic transient flow analysis method considering complex factors such as the cyclic injection and production history in a gas field storage facility was established in view of the limitations of the existing methods for transient flow analysis and the characteristics of the injection-production operation of strongly heterogeneous gas reservoirs, and the corresponding theoretical charts were drawn. In addition, an injection-production dynamic transient flow analysis model named "three points and two stages" suitable for an underground gas storage(UGS) well with alternate working conditions was proposed. The "three points" refer to three time points during cyclic injection and production, namely, the starting point of gas injection for UGS construction, the beginning and ending points of the injection-production analysis stage;and the "two stages" refer to historical flow stage and injection-production analysis stage. The study shows that the dimensionless pseudo-pressure and dimensionless pseudo-pressure integral curves of UGS well flex downward in the early stage of the injection and production process, and the dimensionless pseudo-pressure integral derivative curve is convex during the gas production period and concave during the gas injection period, and the curves under different flow histories have atypical features. The new method present in this paper can analyze transient flow of UGS accurately. The application of this method to typical wells in Hutubi gas storage shows that the new method can fit the pressure history accurately, and obtain reliable parameters and results.展开更多
基金the Fundamental Research Funds for the Central Universities of China(No.20CX02308A)CNOOC Project(No.ZX2022ZCCYF3835).
文摘China’s unconventional gas fields have a large number of low-productivity and low-efficiency wells, many of whichare located in remote and environmentally harsh mountainous areas. To address the long-term stable productionof these gas wells, plunger-lift technology plays an important role. In order to fully understand and accurately graspthe drainage and gas production mechanisms of plunger-lift, a mechanical model of plunger-liquid column uplift inthe plunger-lift process was established, focusing on conventional plunger-lift systems and representative wellboreconfigurations in the Linxing region. The operating casing pressure of the plunger-lift process and the calculationmethod for the maximum daily fluid production rate based on the work regime with the highest fluid recovery ratewere determined. For the first time, the critical flow rate method was proposed as a constraint for the maximumliquid-carrying capacity of the plunger-lift, and liquid-carrying capacity charts for conventional plunger-lift withdifferent casing sizes were developed. The results showed that for 23/8 casing plunger-lift, with a well depth ofshallower than 808 m, the maximum drainage rate was 33 m3/d;for 27/8 casing plunger-lift, with a well depth ofshallower than 742 m, the maximum drainage rate was 50.15 m3/d;for 31/2 casing plunger-lift, with a well depthof shallower than 560 m, the maximum drainage rate was 75.14 m3/d. This research provides a foundation for thescientific selection of plunger-lift technology and serves as a decision-making reference for developing reasonableplunger-lift work regimes.
文摘Summary: We performed a retrospective, case-control study to evaluate whether the urine flow acceleration (UFA, mL/s2) is superior to maximum uroflow (Qmax, mL/s) in diagnosing bladder outlet obstruction (BOO) in patients with benign prostatic hyperplasia (BPH). In this study, a total of 50 men with BPH (age: 58±12.5 years) and 50 controls (age: 59±13.0 years) were included. A pressure-flow study was used to determine the presence of BOO according to the recommendations of Incontinence Control Society (ICS). The results showed that the UFA and Qmax in BPH group were much lower than those in the control group [(2.05±0.85) vs. (4.60±1.25) mL/s2 and (8.50±1.05) vs. (13.00±3.35) mL/s] (P〈0.001). Accol;ding to the criteria (UFA〈2.05 mL/s2, Qmax〈10 mL/s), the sensitivity and specificity of UFA vs. Qmax in diagnosing BOO were 88%, 75% vs. 81%, 63%. UFA vs. Omax, when compared with the results of P-Q chart (the kappa values in corresponding analysis), was 0.55 vs. 0.35. The pros- tate volume, post void residual and detrusor pressure at Qmax between the two groups were 28.6±9.8 vs. 24.2±7.6 mL, 60.4±1.4 vs. 21.3±2.5 mL and 56.6±8.3 vs. 21.7±6.1 cmHzO, respectively (P〈0.05). It was concluded that the UFA is a useful urodynamic parameter, and is superior to Qmax in diagnosing BOO in patients with BPH.
基金Supported by the CNPC Major Scientific and Technological Project(2019B-3204)PetroChina Major Scientific and Technological Project(kt2020-16-01)。
文摘A dynamic transient flow analysis method considering complex factors such as the cyclic injection and production history in a gas field storage facility was established in view of the limitations of the existing methods for transient flow analysis and the characteristics of the injection-production operation of strongly heterogeneous gas reservoirs, and the corresponding theoretical charts were drawn. In addition, an injection-production dynamic transient flow analysis model named "three points and two stages" suitable for an underground gas storage(UGS) well with alternate working conditions was proposed. The "three points" refer to three time points during cyclic injection and production, namely, the starting point of gas injection for UGS construction, the beginning and ending points of the injection-production analysis stage;and the "two stages" refer to historical flow stage and injection-production analysis stage. The study shows that the dimensionless pseudo-pressure and dimensionless pseudo-pressure integral curves of UGS well flex downward in the early stage of the injection and production process, and the dimensionless pseudo-pressure integral derivative curve is convex during the gas production period and concave during the gas injection period, and the curves under different flow histories have atypical features. The new method present in this paper can analyze transient flow of UGS accurately. The application of this method to typical wells in Hutubi gas storage shows that the new method can fit the pressure history accurately, and obtain reliable parameters and results.