期刊文献+
共找到7,754篇文章
< 1 2 250 >
每页显示 20 50 100
Optimization of Minimum Power Output for Combined Heat and Power Units Considering Peak Load Regulation Ability 被引量:1
1
作者 Cong Liu Deyue Men +4 位作者 Dan Xu Qiang Ding Guodong Huang Sai Dai Jingyang Zhou 《Energy and Power Engineering》 2017年第4期452-463,共12页
Northern China has rich wind power and photovoltaic renewable resources. Combined Heat and Power (CHP) Units to meet the load demand and limit its peaking capacity in winter, to a certain extent, it results in structu... Northern China has rich wind power and photovoltaic renewable resources. Combined Heat and Power (CHP) Units to meet the load demand and limit its peaking capacity in winter, to a certain extent, it results in structural problems of wind-solar power and thermoelectric. To solve these problems, this paper proposes a plurality of units together to ensure supply of heat load on the premise, by building a thermoelectric power peaking considering thermal load unit group dynamic scheduling model, to achieve the potential of different thermoelectric properties peaking units of the excavation. Simulation examples show, if the unit group exists obvious relationship thermoelectric individual differences, the thermal load dynamic scheduling can be more significantly improved overall performance peaking unit group, effectively increase clean energy consumptive. 展开更多
关键词 CHP units PEAK LOAD Regulation Thermal LOAD Distribution Solar Wind power CONSUMPTION Dynamic Scheduling
下载PDF
ELECTRONIC CONTROL OF TURBINE POWER UNITS
2
作者 Wang Daobo(Department of Science and Technology,NUAA 29 Yudao Street,Nanjing 210016,P.R.China) 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1994年第2期177-182,共6页
This paper is concerned with the development of electronic controller for turbine POwer units. In order to increase the reliability of the POwer unit, three control loops working in the hi-backup mode have been employ... This paper is concerned with the development of electronic controller for turbine POwer units. In order to increase the reliability of the POwer unit, three control loops working in the hi-backup mode have been employed. This control strategy is able to satisfy the demands of the application of the power unit to the aviation fields. 展开更多
关键词 ELECTRONIC CONTROL power units AUXILIARY power supply TURBINE power units
下载PDF
Price prediction of power transformer materials based on CEEMD and GRU
3
作者 Yan Huang Yufeng Hu +2 位作者 Liangzheng Wu Shangyong Wen Zhengdong Wan 《Global Energy Interconnection》 EI CSCD 2024年第2期217-227,共11页
The rapid growth of the Chinese economy has fueled the expansion of power grids.Power transformers are key equipment in power grid projects,and their price changes have a significant impact on cost control.However,the... The rapid growth of the Chinese economy has fueled the expansion of power grids.Power transformers are key equipment in power grid projects,and their price changes have a significant impact on cost control.However,the prices of power transformer materials manifest as nonsmooth and nonlinear sequences.Hence,estimating the acquisition costs of power grid projects is difficult,hindering the normal operation of power engineering construction.To more accurately predict the price of power transformer materials,this study proposes a method based on complementary ensemble empirical mode decomposition(CEEMD)and gated recurrent unit(GRU)network.First,the CEEMD decomposed the price series into multiple intrinsic mode functions(IMFs).Multiple IMFs were clustered to obtain several aggregated sequences based on the sample entropy of each IMF.Then,an empirical wavelet transform(EWT)was applied to the aggregation sequence with a large sample entropy,and the multiple subsequences obtained from the decomposition were predicted by the GRU model.The GRU model was used to directly predict the aggregation sequences with a small sample entropy.In this study,we used authentic historical pricing data for power transformer materials to validate the proposed approach.The empirical findings demonstrated the efficacy of our method across both datasets,with mean absolute percentage errors(MAPEs)of less than 1%and 3%.This approach holds a significant reference value for future research in the field of power transformer material price prediction. 展开更多
关键词 power transformer material Price prediction Complementary ensemble empirical mode decomposition Gated recurrent unit Empirical wavelet transform
下载PDF
Source-Load Coordinated Optimal Scheduling Considering the High Energy Load of Electrofused Magnesium and Wind Power Uncertainty
4
作者 Juan Li Tingting Xu +3 位作者 Yi Gu Chuang Liu Guiping Zhou Guoliang Bian 《Energy Engineering》 EI 2024年第10期2777-2795,共19页
In fossil energy pollution is serious and the“double carbon”goal is being promoted,as a symbol of fresh energy in the electrical system,solar and wind power have an increasing installed capacity,only conventional un... In fossil energy pollution is serious and the“double carbon”goal is being promoted,as a symbol of fresh energy in the electrical system,solar and wind power have an increasing installed capacity,only conventional units obviously can not solve the new energy as the main body of the scheduling problem.To enhance the systemscheduling ability,based on the participation of thermal power units,incorporate the high energy-carrying load of electro-melting magnesiuminto the regulation object,and consider the effects on the wind unpredictability of the power.Firstly,the operating characteristics of high energy load and wind power are analyzed,and the principle of the participation of electrofusedmagnesiumhigh energy-carrying loads in the elimination of obstructedwind power is studied.Second,a two-layer optimization model is suggested,with the objective function being the largest amount of wind power consumed and the lowest possible cost of system operation.In the upper model,the high energy-carrying load regulates the blocked wind power,and in the lower model,the second-order cone approximation algorithm is used to solve the optimizationmodelwithwind power uncertainty,so that a two-layer optimizationmodel that takes into account the regulation of the high energy-carrying load of the electrofused magnesium and the uncertainty of the wind power is established.Finally,the model is solved using Gurobi,and the results of the simulation demonstrate that the suggested model may successfully lower wind abandonment,lower system operation costs,increase the accuracy of day-ahead scheduling,and lower the final product error of the thermal electricity unit. 展开更多
关键词 High energy load of electrofused magnesium wind energy consumption thermal power unit wind power uncertainty two-layer optimization
下载PDF
Research on Optimization for Units Start During Power System Restoration
5
作者 Jun Chen Wei-xing Zhao +4 位作者 Hua-ying Su Jia-lin Bai Nian Liu Xiao-yan Qiu Qian Liao 《Energy and Power Engineering》 2013年第4期708-712,共5页
Considering units starting and network constraints and the concept of optimization period,a optimization model which is a typical multi-constraint knapsack problem is established to solve the selection optimization pr... Considering units starting and network constraints and the concept of optimization period,a optimization model which is a typical multi-constraint knapsack problem is established to solve the selection optimization problem of units starting in power system restoration period in this paper, and the objective of the model is to maximize the total power generation capability. A relative effectiveness assessment based on a improving data envelopment analysis is adopted to select the initial units to be started, genetic algorithms are employed to solve the knapsack problem to determine the most reasonable units be started at the current time. Finally, IEEE-39 bus system simulation result proves that the proposed model is feasible and effective. 展开更多
关键词 power system units START DATA envelopment analysis KNAPSACK PROBLEM
下载PDF
Large Units, Large Plants -Major Thermal Power Sources
6
《Electricity》 1996年第2期7-12,共6页
China’s electric power industry as a basic industry, plays an important role in the longterm, sustained and healthy development of the whole national economy. China’s electric power industry attained great achieveme... China’s electric power industry as a basic industry, plays an important role in the longterm, sustained and healthy development of the whole national economy. China’s electric power industry attained great achievement in technology and economical results during the past eight years from 1987-1995. The total national installed generating capacity increased from 102.897 GW in 1987 to more than 200 GW in March, 1995. 展开更多
关键词 GENE Major Thermal power Sources Large Plants Large units
下载PDF
Speed up the Retrofit of Thermal Power Generating Units, Raise the Effectiveness of Power Plant Comprehensively
7
作者 Jiang Zhesheng 《Electricity》 2000年第1期13-16,共4页
关键词 Speed up the Retrofit of Thermal power Generating units Raise the Effectiveness of power Plant Comprehensively
下载PDF
1133.5 MW Small Thermal Power Units to be Shut Down in Jiangsu
8
《Electricity》 1999年第3期51-51,共1页
关键词 MW Small Thermal power units to be Shut Down in Jiangsu DOWN
下载PDF
8 large coal-fired generating units planned to be commissioned in Shandong Power Grid in 1997
9
《Electricity》 1997年第2期51-52,共2页
关键词 GRID large coal-fired generating units planned to be commissioned in Shandong power Grid in 1997
下载PDF
Two 140 MW cogeneration units will be installed in the Beijing No.1 Cogeneration Power Plant
10
《Electricity》 1997年第2期7-7,共1页
关键词 WILL Two 140 MW cogeneration units will be installed in the Beijing No.1 Cogeneration power Plant
下载PDF
Characteristic Analysis of Power Oscillations Caused by Disharmony Among Voltage-source-controlled Units in Three-terminal Local Power Grid
11
作者 Qiyi Yu Yi Tang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第4期1295-1308,共14页
Previous studies have demonstrated that disharmony among voltage-source-controlled units(VSCUs)may occur on an alternating current(AC)transmission or distribution line under steady-state operating conditions(SSOCs)or ... Previous studies have demonstrated that disharmony among voltage-source-controlled units(VSCUs)may occur on an alternating current(AC)transmission or distribution line under steady-state operating conditions(SSOCs)or quasistatic operating conditions(QSSOCs).As the studies on frequency disharmony have been expanded to multiple disharmonized vS-CUs in the local power grid,its adverse effects on AC lines and equivalent load(EL)at the bus without active voltage control ability(non-active bus)need to be investigated further.Considering the locality of disharmony and common topological con-nections among VSCUs,this paper adopts a Y-type three-termi-nal local power grid(LPG)as the research object.The disharmony among the three VSCUs is discussed.Firstly,for the load at non-active bus,the formulas for single-phase instantaneous voltage,load current,load power,as well as average power un-der disharmony operating conditions(DOCs)are derived.The characteristic indicators of the above electrical quantities are defined,which can measure the amplification and reduction de-grees of the above electrical quantities before and after disharmony.Secondly,for the line directly connected to VSCUs,the formulas for single-phase instantaneous line current and power and the average power under DOCs are derived.The characteristic indicators of power flow are defined,which can be used to quantify the peak amplification impact of oscillation before and after disharmony.Finally,the case study on the Y-type three-terminal LPG under the single-disharmony and the multi-dis-harmony switching scenarios indicates that the long-period pow-er oscillation caused by disharmony may occur in the load flow at the non-active bus and the line flow.The oscillation causes a serious decrease in load capability and a significant amplification of the peak of line power oscillation. 展开更多
关键词 New power system power oscillation disharmony voltage-source-controlled unit(VSCU) characteristic analysis
原文传递
Multi-model Predictive Control of Ultra-supercritical Coal-fired Power Unit 被引量:6
12
作者 王国良 阎威武 +2 位作者 陈世和 张曦 邵惠鹤 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2014年第7期782-787,共6页
The control of ultra-supercritical(USC) power unit is a difficult issue for its characteristic of the nonlinearity, large dead time and coupling of the unit. In this paper, model predictive control(MPC) based on multi... The control of ultra-supercritical(USC) power unit is a difficult issue for its characteristic of the nonlinearity, large dead time and coupling of the unit. In this paper, model predictive control(MPC) based on multi-model and double layered optimization is introduced for coordinated control of USC unit. The linear programming(LP) combined with quadratic programming(QP) is used in steady optimization for computation of the ideal value of dynamic optimization. Three inputs(i.e. valve opening, coal flow and feedwater flow) are employed to control three outputs(i.e. load, main steam temperature and main steam pressure). The step response models for the dynamic matrix control(DMC) are constructed using the three inputs and the three outputs. Piecewise models are built at selected operation points. Double-layered multi-model predictive controller is implemented in simulation with satisfactory performance. 展开更多
关键词 Ultra-supercritical power unit Coordinated control Multi-model constrained predictive control
下载PDF
Tracking Galloping Profile of Transmission Lines Using Wireless Inertial Measurement Units 被引量:3
13
作者 Kai Xie Chao Zhang +2 位作者 Qing Li Wang-Lin Wu Yi-Qing Ni 《Journal of Computer and Communications》 2015年第5期220-228,共9页
Galloping of power transmission lines might bring about huge damage such as massive power outage and collapse of the transmission towers. To realize forecast of the galloping and provide data for study on the gallopin... Galloping of power transmission lines might bring about huge damage such as massive power outage and collapse of the transmission towers. To realize forecast of the galloping and provide data for study on the galloping mechanism, this paper proposes an online monitoring system for tracking galloping profile of power transmission lines based on wireless inertial measurement units (WIMUs). The system is composed of three modules: wireless inertial measurement nodes, monitoring base station, and remote monitoring station. After detailing the hardware system, the corresponding software which positions and displays galloping profile of the transmission line in real-time is outlined. The feasibility of the proposed on-line monitoring system is demonstrated through a series of experiments at the State Grid Key Laboratory of Power Overhead Transmission Line Galloping (Zhengzhou, China) by taking into account different vibration patterns. 展开更多
关键词 power Transmission LINES GALLOPING Vibration ON-LINE Monitoring WIRELESS INERTIAL Measurement units
下载PDF
Power management unit chip design for automobile active-matrix organic light-emitting diode display module 被引量:4
14
作者 KIM J H PARK J H +7 位作者 KIM J H CAO T V LEE T Y BAN H J YANG K KIM H G HA P B KIM Y H 《Journal of Central South University》 SCIE EI CAS 2009年第4期621-628,共8页
A power management unit (PMU) chip supplying dual panel supply voltage, which has a low electro-magnetic interference (EMI) characteristic and is favorable for miniaturization, is designed. A two-phase charge pump... A power management unit (PMU) chip supplying dual panel supply voltage, which has a low electro-magnetic interference (EMI) characteristic and is favorable for miniaturization, is designed. A two-phase charge pump circuit using external pumping capacitor increases its pumping current and works out the charge-loss problem by using bulk-potential biasing circuit. A low-power start-up circuit is also proposed to reduce the power consumption of the band-gap reference voltage generator. And the ring oscillator used in the ELVSS power circuit is designed with logic devices by supplying the logic power supply to reduce the layout area. The PMU chip is designed with MagnaChip's 0.25 μ high-voltage process. The driving currents of ELVDD and ELVSS are more than 50 mA when a SPICE simulation is done. 展开更多
关键词 DC-DC converter AMOLED charge pumping power management unit (PMU) dual panel supply voltage
下载PDF
Unit Commitment under the Environment of Wind Power and Large-Scale Bilateral Transactions 被引量:1
15
作者 Fang Liu Yi Pan +2 位作者 Junfeng Yang Zhiqiang Luo Lihua Liu 《Energy and Power Engineering》 2017年第4期611-624,共14页
Bilateral electric power contract is settled based on contract output curve. This paper considered the bilateral transactions execution, new energy accommodation, power grid security and generation economy, considerin... Bilateral electric power contract is settled based on contract output curve. This paper considered the bilateral transactions execution, new energy accommodation, power grid security and generation economy, considering the executive priority of different power components to establish a multi-objective coordination unit commitment model. Through an example to verify the effectiveness of the model in promoting wind power consumption, guaranteeing trade execution, and improving power generation efficiency, and analyzed the interactions to each other among the factors of wind power, trading and blocking. According to the results, when wind power causes reverse power flow in the congestion line, it will promote the implementation of contracts, the influence of wind power accommodation to trade execution should be analyzed combined with the grid block, the results can provide reference for wind power planning. 展开更多
关键词 Bilateral Electric power CONTRACT unit COMMITMENT Wind power ACCOMMODATION TRANSACTION Execution CONGESTION
下载PDF
LVP Modeling and Dynamic Characteristics Prediction of A Hydraulic Power Unit in Deep-Sea 被引量:1
16
作者 曹学鹏 叶敏 +2 位作者 邓斌 张翠红 俞祖英 《China Ocean Engineering》 SCIE EI CSCD 2013年第1期17-32,共16页
A hydraulic power unit (HPU) is the driving "heart" of deep-sea working equipment. It is critical to predict its dynamic performances in deep-water before being immerged in the seawater, while the experimental tes... A hydraulic power unit (HPU) is the driving "heart" of deep-sea working equipment. It is critical to predict its dynamic performances in deep-water before being immerged in the seawater, while the experimental tests by simulating deep-sea environment have many disadvantages, such as expensive cost, long test cycles, and difficult to achieve low-temperature simulation, which is only used as a supplementary means for confirmatory experiment. This paper proposes a novel theoretical approach based on the linear varying parameters (LVP) modeling to foresee the dynamic performances of the driving unit. Firstly, based on the varying environment features, dynamic expressions of the compressibility and viscosity of hydranlic oil are derived to reveal the fluid performances changing. Secondly, models of hydraulic system and electrical system are accomplished respectively through studying the control process and energy transfer, and then LVP models of the pressure and flow rate control is obtained through the electro-hydraulic models integration. Thirdly, dynamic characteristics of HPU are obtained by the model simulating within bounded closed sets of varying parameters. Finally, the developed HPU is tested in a deep-sea imitating hull, and the experimental results are well consistent with the theoretical analysis outcomes, which clearly declare that the LVP modeling is a rational way to foresee dynamic performances of HPU. The research approach and model analysis results can be applied to the predictions of working properties and product designs for other deep-sea hydraulic pump. 展开更多
关键词 hydraulic power unit (HPLO linear varying parameters (L VP) modeling dynamic viscosity characteristics prediction
下载PDF
Application of Solid Oxide Fuel Cell-Auxiliary Power Unit on Different Trucks in Northeast China
17
作者 周苏 王士嘉 《Journal of Donghua University(English Edition)》 EI CAS 2015年第4期565-570,共6页
A diesel engine of conventional trucks has a low efficiency under the idling condition,leading to a high cost for heating or cooling in the cab during night. The solution to this problem will have great significance o... A diesel engine of conventional trucks has a low efficiency under the idling condition,leading to a high cost for heating or cooling in the cab during night. The solution to this problem will have great significance on energy conservation and emission reduction. A new auxiliary power unit of solid oxide fuel cell( SOFCAPU) with high efficiency solves this problem perfectly. Heat pump air conditioner is considered as a promising device for the application of SOFC-APU with a high cooling and heating efficiency. To make a quantitative analysis for the application of SOFC-APU,a model is built in Matlab / Simulink. The diesel engine model and SOFC-APU model are fitted based on some experimental data of SOFC-APU and diesel engine during the idling operation. An analysis of the application of SOFC-APU on different trucks in Northeast China is comprehensively made,including efficiency and emission. 展开更多
关键词 diesel engine TRUCK heating and cooling power emissions AUXILIARY power unit of solid oxide fuel cell(SOFC-APU)
下载PDF
Control of Unit Power Factor PWM Rectifier
18
作者 Meifang Xue Mingzhi He 《Energy and Power Engineering》 2013年第4期121-124,共4页
To solve the problem of harmonic pollution to the power grid that caused by traditional diode rectifier and phase controlled rectifier, the unit power factor PWM rectifier is designed. The topology structure of the re... To solve the problem of harmonic pollution to the power grid that caused by traditional diode rectifier and phase controlled rectifier, the unit power factor PWM rectifier is designed. The topology structure of the rectifier circuit is introduced and the double closed-loop control strategy in three-phase stationary coordinate system is analyzed. For the deficiency of control strategy, the control strategy in two-phase synchronous rotating coordinate system is proposed. This makes the independent control of active current and reactive current to be realized. The simulation model of the PWM rectifier is built and the effectiveness of the control method proposed in this paper is verified by simulation. 展开更多
关键词 CONTROL PWM RECTIFIER unit power FACTOR d q COORDINATES
下载PDF
Unit stream power,minimum energy dissipation rate,and river engineering
19
作者 Chih Ted Yang 《水道港口》 2010年第5期317-317,共1页
Unit stream power is the most important and dominant parameter for the determination of transport rate of sand,gravel,and hyper-concentrated sediment with wash load.Minimum energy dissipation rate theory,or its simpli... Unit stream power is the most important and dominant parameter for the determination of transport rate of sand,gravel,and hyper-concentrated sediment with wash load.Minimum energy dissipation rate theory,or its simplified minimum unit stream power and minimum stream power theories,can provide engineers the needed theoretical basis for river morphology and river engineering studies.The Generalized Sediment Transport model for Alluvial River Simulation computer mode series have been developed based on the above theories.The computer model series have been successfully applied in many countries.Examples will be used to illustrate the applications of the computer models to solving a wide range of river morphology and river engineering problems. 展开更多
关键词 computer model minimum energy dissipation rate river engineering river morphology sediment transport unit stream power
下载PDF
Extended Sequential Truncation Technique for Adaptive Dynamic Programming Based Security-Constrained Unit Commitment with Optimal Power Flow Constraints
20
作者 Danli Long Hua Wei 《Journal of Power and Energy Engineering》 2014年第4期687-693,共7页
Considering the economics and securities for the operation of a power system, this paper presents a new adaptive dynamic programming approach for security-constrained unit commitment (SCUC) problems. In response to t... Considering the economics and securities for the operation of a power system, this paper presents a new adaptive dynamic programming approach for security-constrained unit commitment (SCUC) problems. In response to the “curse of dimension” problem of dynamic programming, the approach solves the Bellman’s equation of SCUC approximately by solving a sequence of simplified single stage optimization problems. An extended sequential truncation technique is proposed to explore the state space of the approach, which is superior to traditional sequential truncation in daily cost for unit commitment. Different test cases from 30 to 300 buses over a 24 h horizon are analyzed. Extensive numerical comparisons show that the proposed approach is capable of obtaining the optimal unit commitment schedules without any network and bus voltage violations, and minimizing the operation cost as well. 展开更多
关键词 power System Operation and Planning PRIORITY Order Adaptive Dynamic PROGRAMMING unit COMMITMENT
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部