期刊文献+
共找到1,804篇文章
< 1 2 91 >
每页显示 20 50 100
Study of Scanning Dose Optimization on Chest and Abdomen Enhanced CT Imaging
1
作者 Zhiwei Huang Lisha Zhong +1 位作者 Bo Xiao Gaofei Cao 《Journal of Signal and Information Processing》 2013年第2期145-148,共4页
Objective: To investigate the correlation between radiation dose and radiation risk when patients are scanned by 64-slice spiral CT. Materials and Methods: SPSS 17.0 is used statistically for analyzing the patient’s ... Objective: To investigate the correlation between radiation dose and radiation risk when patients are scanned by 64-slice spiral CT. Materials and Methods: SPSS 17.0 is used statistically for analyzing the patient’s scanning parameters, radiation dose of monitoring and examining the patients who are scanning of their abdomen, chest and pelvic in our affiliated hospital. Results: SPSS statistical analysis shows that the factor related to radiation dose is scanning layer;the basic characteristics such as height and heart rate don’t affect the patient’s scan dose directly. Conclusion: Increasing the delay time after injection can reduce the scan numbers and monitoring layers of the machine, thus reduce the patient’s radiation dose and tube’s exposure time. 展开更多
关键词 enhanced CT scan scanNING Technology Parameters DOSE Monitoring Radiation DOSE
下载PDF
Correlation between CT dynamic enhanced scanning parameters and serum tumor markers before and after radiofrequency ablation in patients with lung cancer
2
作者 Yi Wang Xu Liang Rui-Yu Zhan 《Journal of Hainan Medical University》 2020年第22期19-23,共5页
Objective:To study the correlation between CT dynamic enhanced scanning parameters and serum tumor markers before and after radiofrequency ablation in patients with lung cancer.Methods:60 patients with advanced non-sm... Objective:To study the correlation between CT dynamic enhanced scanning parameters and serum tumor markers before and after radiofrequency ablation in patients with lung cancer.Methods:60 patients with advanced non-small cell lung cancer who were treated in this hospital between January 2015 and January 2017 were divided into control group(n=30)and observation group(n=30)by random number table method.Control group received conventional intravenous chemotherapy,and observation group received intravenous chemotherapy combined with radiofrequency ablation.The differences in CT dynamic enhanced scanning parameter levels and serum tumor marker contents were compared between the two groups of patients before and after treatment.Pearson test was used to evaluate the correlation between CT dynamic enhanced scanning parameters and serum tumor marker contents in patients with advanced non-small cell lung cancer.Results:Before treatment,the differences in CT dynamic enhanced scanning parameter levels,non-organ-specific tumor marker contents and vascular tumor marker contents were not statistically significant between the two groups of patients(P>0.05).After treatment,CT dynamic enhanced scanning parameters PH and perfusion value levels of observation group were lower than those of control group(P<0.05);serum non-organ specific tumor markers CA125,CA153,CEA and CYFRA21-1 contents of observation group were lower than those of control group;serum vascular tumor markers VEGF,Ang-2,HIF-1 and MMP-9 contents were lower than those of control group(P<0.05).Pearson test showed that CT dynamic enhanced scanning parameters PH and perfusion value levels in patients with non-small cell lung cancer were positively correlated with serum non-organ specific tumor marker and vascular tumor marker contents.Conclusion:Adjuvant radiofrequency ablation can significantly reduce the tumor malignancy of patients with advanced non-small cell lung cancer. 展开更多
关键词 Lung cancer Radiofrequency ablation CT dynamic enhanced scanning Tumor marker
下载PDF
Diagnostic value of MSCT plain scan and dual-phase enhanced scan in thymic adenocarcinoma
3
作者 Bing Liu Xiao-Feng Yang +5 位作者 Ting Sun Shui-Xiang Di Jiang-Hua Su Xiu-Zhong Wang Ning Song Yu-Fang He 《Journal of Hainan Medical University》 2019年第7期65-68,共4页
Objective: To evaluate the value of MSCT plain scan and enhanced CT in the diagnosis of thymic adenocarcinoma. Methods: From May 2013 to June 2018, 37 cases of MSCT plain scan and dual-phase enhanced scan of thymic ad... Objective: To evaluate the value of MSCT plain scan and enhanced CT in the diagnosis of thymic adenocarcinoma. Methods: From May 2013 to June 2018, 37 cases of MSCT plain scan and dual-phase enhanced scan of thymic adenocarcinoma were retrospectively analyzed. The location, shape, size, density (CT value), enhanced features, peripheral invasion and mediastinal lymph node metastasis of the lesions were observed. Results: All 37 cases of thymic adenocarcinoma were diagnosed by CT before operation, and all cases were diagnosed by pathology after operation as malignant tumors,including 28 cases of thoracic adenocarcinoma and 9 cases of invasive thymoma. All 28 cases of thymic adenocarcinoma were single lesion of anterior superior mediastinum. The maximum cross-section was located in the midline in 7 cases and on the mediastinal side in 21 cases with significant difference (P<0.05). All lesions were irregular lobulated. The minimum diameter of lesions was 2.1 cm and the maximum diameter was 8.6 cm. Soft tissue density was dominant in the solid part. All cases of thymic adenocarcinoma showed inhomogeneous, moderate and severe enhancement in the arterial and venous phase after enhancement. The degree of enhancement in the venous phase was higher than that in the arterial phase, and there was no enhancement in the irregular liquefied necrosis area. 26 cases had necrotic lesions, 21 cases had mediastinal lymph node metastasis, and 8 cases had invasion of adjacent pleura. 19 cases had mediastinal vessels and 0 cases had distant pleural metastases. Conclusion: MSCT plain scan combined with dual-phase enhanced CT is helpful to display the details and metastasis of thymic adenocarcinoma, improve the coincidence rate of CT diagnosis and pathological diagnosis, and reduce the misdiagnosis rate. To provide help for clinical diagnosis and treatment of thymic adenocarcinoma. 展开更多
关键词 THYMIC cancer COMPUTED tomography PLAIN and DUAL-PHASE enhanced scanning COMPUTER-ASSISTED imaging
下载PDF
Observations on the Diagnostic Effects of CT Examination(Enhanced Scan)on Hemorrhage Corpus Luteum Cyst
4
作者 Xiang Gao Heng Tang +3 位作者 Lianglong Wu Zou Mei Liangjin Liu Junying Bi 《Proceedings of Anticancer Research》 2020年第6期49-52,共4页
Objective:To investigate the diagnostic effects of enhanced CT scan on hemorrhage corpus luteum cyst(HCLC).Methods:The clinical data of 24 patients with hemorrhage corpus luteum cyst diagnosed by surgery and pathology... Objective:To investigate the diagnostic effects of enhanced CT scan on hemorrhage corpus luteum cyst(HCLC).Methods:The clinical data of 24 patients with hemorrhage corpus luteum cyst diagnosed by surgery and pathology in our hospital were collected.All patients received enhanced CT scan to evaluate the diagnostic value of CT.Results:The average diameter of the cysts in this group of patients was 5.1cm by CT.Further detection of the ruptured cyst wall showed that there was a liquid lowdensity shadow.Some of the cysts were accompanied by signs of increased density,indicating the presence of blood clots;all patients received surgical treatment.Intraoperative ultrasound examination of the cysts had an average diameter of 5.2cm and a wall of 0.2~0.4mm.Among them,19 cases of cysts contained"coffee-colored"liquid with varying degrees of blood clots,and 5 cases had no blood clots in the cysts but there were a lot of blood clots beside the cysts.Conclusion:The application of enhanced CT scan in patients with hemorrhage corpus luteum cyst is of great value.It can provide accurate data reference for clinical treatment and is worthy of promoting its clinical application. 展开更多
关键词 enhanced CT scan Hemorrhage corpus luteum cyst Diagnostic effects
下载PDF
Diagnostic Value of Spiral CT Chest Enhanced Scan in Adult with Active Pulmonary Tuberculosis
5
作者 Ruishu Wang 《Journal of Clinical and Nursing Research》 2020年第3期1-4,共4页
Aim:To explore the diagnostic value of spiral CT chest enhanced scan for adults with active pulmonary tuberculosis.Methods:The clinical data of 60 adult patients with active pulmonary tuberculosis who were treated in ... Aim:To explore the diagnostic value of spiral CT chest enhanced scan for adults with active pulmonary tuberculosis.Methods:The clinical data of 60 adult patients with active pulmonary tuberculosis who were treated in our hospital from January 2018 to November 2019 were retrospectively analyzed.All patients underwent conventional chest radiography and spiral CT chest enhanced scan.The number of tuberculosis diagnosis,the detection rate of special site lesions,and the detection rate of active pulmonary tuberculosis signs by the two methods were compared.Results:In 60 patients,the pathological results confirmed the existence of 75 tuberculosis lesions.The detection rate of spiral CT was 98.67%,which was not statistically significant compared with the detection rate of 92.00%(P>0.05)in the conventional chest X-ray.The detection rate of spiral CT enhanced scans for tuberculosis lesions in special sites was 100.00%,which was significantly higher than that of conventional chest X-ray of 7.69%,and the accuracy rate of active pulmonary tuberculosis signs was 98.85%higher than that of conventional chest X-ray of 79.31%.P<0.05).The difference was statistically significant(P<0.05).Conclusion:Spiral CT chest enhanced scan can not only find special tuberculosis lesions that cannot be detected by conventional chest radiography,but also accurately determine active pulmonary tuberculosis in adults,which is of high diagnostic value. 展开更多
关键词 Active pulmonary tuberculosis ADULT Spiral CT enhanced scan Signs of active pulmonary tuberculosis
下载PDF
A case of occult insulinoma localized by pancreatic dynamic enhanced spiral CT 被引量:3
6
作者 Bao, Zhao-Kang Huang, Xin-Yu +3 位作者 Zhao, Jun-Gong Zheng, Qi Wang, Xiao-Feng Wang, Hong-Cheng 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第11期1418-1421,共4页
Insulinomas are the most common category of pancreatic endocrine tumors,with an annual incidence of 1-4 cases per million people.Most are intrapancreatic,benign and solitary.Therefore,they have an excellent prognosis ... Insulinomas are the most common category of pancreatic endocrine tumors,with an annual incidence of 1-4 cases per million people.Most are intrapancreatic,benign and solitary.Therefore,they have an excellent prognosis after surgical resection.However,the localization diagnosis of insulinomas still poses a challenge to surgeons and radiologists.In this case,the tumor was occult and could not be found by either abdominal enhanced spiral computed tomography(CT)or ultrasonography.Therefore,we tried a new method of CT scanning and localized the tumor. 展开更多
关键词 INSULINOMA Computed tomography Localization diagnosis Dynamic enhanced scan enhancement value
下载PDF
Spiral multi-phase CT in evaluating resectability of pancreatic carcinoma 被引量:2
7
作者 Qing-Juan Huang Qing Xu +1 位作者 Xiao-Ning Wang Lian-Liang Zhang the Department of Radiology, First Affiliated Hospital, Nanjing Medical University, Nanjing 210029, China 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2002年第4期614-619,共6页
Objectives: To evaluate the specific manifestations of pancreatic carcinoma on spiral multi-phase CT and its resectability before operation. Methods: Ninety-seven patients were confirmed oper- atively and pathological... Objectives: To evaluate the specific manifestations of pancreatic carcinoma on spiral multi-phase CT and its resectability before operation. Methods: Ninety-seven patients were confirmed oper- atively and pathologically. Enhanced CT scan was performed with intravenous injection bolus of ap- proximately 75-120 ml (1-1.5 ml/kg body weight) contrast medium at a rate of 2.5-3 ml/s. In 68 pa- tients receiving dual-phase scan, the delayed scan time of arterial and venous phases was 18-20 s and 60-70 s, respectively, and in 29 patients receiving three-phase scan, the delayed scan time of arterial, pancreatic and portal venous phases was 18 s, 40 s and 75 s, respectively, with a slice of 3-5 mm thick- ness, a pitch of 1-1.5, and a reconstruction interval of 2.5-4.8 mm. Results: Positive and negative predictive values of un- resectable tumors were 97.65% and 75.86%, respec- tively. The sensitivity and accuracy were 90.67% and 90. 72%, respectively. Positive predictive values of dual-phase and three-phase were 95.83% and 100%, respectively; negative predictive values were 75% and 77.78%, respectively. Conclusions: Spiral multi-phase CT is superior in re- vealing the involvement of peripancreatic vessels, the invasion of the neighboring organs, the size, shape and range of carcinoma, and the metastasis of liver and lymph node. The predictability of resection is obviously increased for patients with pancreatic car- cinoma. 展开更多
关键词 pancreatic carcinoma SURGERY spiral computed tomography (CT) enhanced scan
下载PDF
Orientation-enhanced nonlinear optical properties and phase-conjugate reflective system of a novel Azobenzene doped polymer film 被引量:1
8
作者 谢茹胜 范文彬 +1 位作者 陆明 赵有源 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第9期2725-2730,共6页
This paper reports that the nonlinear refractive index of a novel organic optical storage film doped azodiphenylamine polymer is measured by using the Z-scan technique. The nonlinear refractive index up to 3.7× 1... This paper reports that the nonlinear refractive index of a novel organic optical storage film doped azodiphenylamine polymer is measured by using the Z-scan technique. The nonlinear refractive index up to 3.7× 10^-6 cm^2/W induced by thermo-optical effect is obtained. It indicates that the sample has excellent optical non- linear properties. The physical mechanism of the great nonlinear optical effect is analysed and the optical conjugate characteristic is also discussed with degenerate four-wave-mixing. The phase conjugate wave diffracted from the formative refractive index grating in the sample is acquired and its equivalent reflectivity reaches about 22%. On this basis, the reflective wave phase-conjugated mirror system was designed, and the image aberration experienced in propagation in the storage experiment is corrected by using the system. 展开更多
关键词 phase conjugated mirror azo-diphenylamine nonlinear refractive index orientation-enhanced Z-scan
下载PDF
Multi-phase helical CT in diagnosis of early hepatocellular carcinoma
9
作者 Wen-Ya Liu Yong Jin +2 位作者 Run-Huan Rong Xi Ta Xin-Sheng Zhu the CT Department, First Affiliated Hospital of Xinjiang Medical University, Urumqi 830054, China 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2003年第1期73-76,共4页
OBJECTIVES: To analyze the characteristics of early hepatocellular carcinoma by using multi-phase helical CT and assess the value of this method. METHODS: Multi-phase helical CT findings were reviewed double-blindly b... OBJECTIVES: To analyze the characteristics of early hepatocellular carcinoma by using multi-phase helical CT and assess the value of this method. METHODS: Multi-phase helical CT findings were reviewed double-blindly by radiologists. RESULTS: Altogether 24 lesions were found in 21 patients. In plain CT, the lesions were seen as hypodense or isodense areas. After contrast enhancement, 87.5% of the lesions showed regular or irregular hyperdense enhancement, whereas 12.5% demonstrated tumor vessels in arterial phase, which became hypodensed or isodensed nodules in portal phase or the hypodensed in delayed phase. The prevalence of density changes showed a hypo-hyper-hypo and hypo-hypo pattern. CONCLUSIONS: Multi-phase helical CT could reflect the blood supply of early hepatocelluar carcinoma, and is also convenient for the differential diagnosis of hepatic cavernous angioma, metastatic tumor, hepatic nodulous hyperplasia, and hepatic inflammatory granuloma. 展开更多
关键词 liver neoplasm spiral CT multi-phase DIAGNOSIS contrast enhancement
下载PDF
The Distribution and Morphology Alterations of Microfilaments and Microtubules in Mesophyll Cells and Root-Tip Cells of Wheat Seedlings under Enhanced Ultraviolet-B Radiation
10
作者 Limei Gao Yongfeng Li +2 位作者 Aihua Guo Jingru Zhai Rong Han 《American Journal of Plant Sciences》 2014年第22期3423-3431,共9页
The distribution and morphology alterations of microfilaments and microtubules in the mesophyll cells and root-tip cells of wheat seedlings, which had been radiated by enhanced ultraviolet-B (10.08 KJ·m-2·d-... The distribution and morphology alterations of microfilaments and microtubules in the mesophyll cells and root-tip cells of wheat seedlings, which had been radiated by enhanced ultraviolet-B (10.08 KJ·m-2·d-1), were examined through the confocal laser scanning microscope (Model FV1000, Olympus, Japan). Microtubule was labeled with an indirect immunofluorescence staining method, and microfilament was labeled with fluorescein isothiocyanate-phalloidin (FITC-Ph) as probes. The results indicated that microtubules in mesophyll cells, compared with the controls, would be depolymerized significantly, and dispersed randomly showing some spots or short rods in the cytoplasm, under the enhanced UV-B radiation condition. The microtubule bundles tended to be diffused, and the fluorescence intensity of that significantly decreased. The distribution pattern of microfilaments, which usually arranged parallelly in control cells, was broken up by enhanced UV-B radiation. We further investigated the distribution and morphology of microtubules in root-tip cells during every stage of cell division, and found that these aberrant phenomena of microtubules were often associated with abnormal cell division. Our findings suggested that the distribution, morphology and structure of cytoskeleton in mesophyll cells and root-tip cells of wheat seedlings would be affected by enhanced UV-B radiation, which might be related to abnormal cell division caused by enhanced UV-B radiation as an extracellular signal. 展开更多
关键词 Wheat MICROFILAMENT MICROTUBULE enhanced UV-B Radiation Confocal Laser scanning Microscope
下载PDF
Different Doses of the Enhanced UV-B Radiation Effects on Wheat Somatic Cell Division
11
作者 Feifeng Liu Huize Chen Rong Han 《CellBio》 2015年第2期30-36,共7页
Being sessile, plants are continuously exposed to DNA-damaging agents presenting in the environment such as ultraviolet (UV). Sunlight acts as an energy source for photosynthetic plants;hence, avoidance of UV radiatio... Being sessile, plants are continuously exposed to DNA-damaging agents presenting in the environment such as ultraviolet (UV). Sunlight acts as an energy source for photosynthetic plants;hence, avoidance of UV radiations (namely, UV-A, 315 - 400 nm;UV-B, 280 - 315 nm;and UV-C, 1 group: 4.05 kJ&#8226m-2&#8226d-1, B2 group: 10.08 kJ&#8226m-2&#8226d-1, B3 group: 7.05 kJ&#8226m-2&#8226d-1, B4 group: 23.02 kJ&#8226m-2&#8226d-1) treatment wheat, then, explored on the growth of wheat root and wheat root tip cell of chromosome aberration effect. In wheat, root-tip cells were observed with confocal laser scanning microscopy (CLSM), the results showed that low doses of B1 group (4.05 kJ&#8226m-2&#8226d-1) promoted the growth of wheat root and cell mitosis frequency. But high dose of B2 group (10.08 kJ&#8226m-2&#8226d-1), B3 group (17.05 kJ&#8226m-2&#8226d-1), B4 group (23.02 kJ&#8226m-2&#8226d-1) inhibited the growth of wheat root tip, and made crooked growth of wheat root, and inhibited the wheat root tip cell mitotic frequency and processed that induce root tip cells of wheat produce all kinds of aberration of chromosome in the interphase containing “multiple nucleoli nuclei”, “incomplete nuclei”, “long round nuclei”, “bean sprouts nucleus”. In mitosis M period contains “dissociative chromosome”, “chromosome bridge”, “adhesion chromosome”, “multi-bundle divide”, “nuclear anomalies”. After, high doses of enhanced UV-B radiation treatment, most of the cell cycle anomaly concentrated in mitosis interphase. In mitosis M period, with UV-B radiation dose enhanced chromosome aberration rate was on the rise and the aberration types also increasing. 展开更多
关键词 WHEAT enhanced UV-B Radiation CHROMOSOME ABERRATION CONFOCAL Laser scanning Microscopy (CLSM)
下载PDF
An enhanced spectral diversity coregistration method for dualpolarimetric Sentinel-1A/B TOPS data
12
作者 Nan Fang Xingjun Luo +5 位作者 Peng Shen Lei Xie Guoming Liu Feixiang Wei Kun Jiang Wenbin Xu 《Geodesy and Geodynamics》 EI CSCD 2023年第5期431-437,共7页
Sentinel-1A/B data are crucial for retrieving numerical information about surface phenomena and processes.Coregistration of terrain observation by progressive scans(TOPS)data is a critical step in its application.TOPS... Sentinel-1A/B data are crucial for retrieving numerical information about surface phenomena and processes.Coregistration of terrain observation by progressive scans(TOPS)data is a critical step in its application.TOPS data must be fundamentally co-registered with an accuracy of 0.001 pixels.However,various decorrelation factors due to natural vegetation and seasonal effects affect the coregistration accuracy of TOPS data.This paper proposed an enhanced spectral diversity coregistration method for dual-polarimetric(PolESD)Sentinel-1A/B TOPS data.The PolESD method suppresses speckle noise based on a unified non-local framework in dual-pol Synthetic Aperture Radar(SAR),and extracts the phase of the optimal polarization channel from the denoised polarimetric interferometric coherency matrix.Compared with the traditional ESD method developed for single-polarization data,the PolESD method can obtain more accurate coherence and phase and get more pixels for azimuth-offset estimation.In bare areas covered with low vegetation,the number of pixels selected by PolESD is more than the Boxcar method.It can also correct misregistration more effectively and eliminate phase jumps in the burst edge.Therefore,PolESD will help improve the application of TOPS data in low-coherence scenarios. 展开更多
关键词 COREGISTRATION Terrain observation by progressive scans (TOPS) enhanced spectral diversity DUAL-POLARIZATION
下载PDF
肺栓塞诊断中多层螺旋CT双期动态增强扫描技术的应用研究
13
作者 柴清华 杨瑞 +1 位作者 刘继伟 弓莉 《临床研究》 2025年第1期133-135,共3页
目的 分析研究肺栓塞诊断中应用多层螺旋CT双期动态增强扫描技术的应用价值。方法 选取河南省胸科医院2020年2月至2022年6月收治的50例疑似肺栓塞患者,选择SOMATOM Definition Flash双源CT扫描机开展胸部平扫和肺动脉期、肺静脉期双期... 目的 分析研究肺栓塞诊断中应用多层螺旋CT双期动态增强扫描技术的应用价值。方法 选取河南省胸科医院2020年2月至2022年6月收治的50例疑似肺栓塞患者,选择SOMATOM Definition Flash双源CT扫描机开展胸部平扫和肺动脉期、肺静脉期双期动态增强CT扫描,分析双期动态增强扫描图像;以综合评定结果为金标准,计算双期动态增强CT扫描检查结果。结果 分析多层螺旋CT双期动态增强扫描图像发现,41例患者诊断为肺栓塞,能精确发现145处栓子,其中13处为左右肺动脉主干,57处为叶动脉,55处为段动脉,18处为亚段动脉,2处为亚亚段动脉。50例患者经综合评估,结果为阳性48例,阴性2例,双期动态增强CT扫描检查结果为阳性46例,阴性4例。双期动态增强CT扫描检查敏感度为95.83%(46/48),特异度为100.00(2/2),准确度为96.00%(48/50)。结论 临床诊断肺栓塞时采用多层螺旋CT双期动态增强扫描技术具有显著的检测和诊断效果,准确性、特异性及敏感度均较高,值得应用。 展开更多
关键词 肺栓塞 多层螺旋CT 双期 动态增强扫描技术 应用价值
下载PDF
Magnetic emission intensity enhancement for amorphous alloys by constructing a multi-phase structure withα-Fe nanocrystals
14
作者 Ke Liu Zhi Qin +5 位作者 Jie Shen Zhi Cheng Shiyue You Liang Ma Jing Zhou Wen Chen 《Nano Research》 SCIE EI CSCD 2024年第7期6630-6637,共8页
The perturbation in the magnetic field generated by the rotation or oscillation of magnetic domains in magnetic materials can emit low-frequency electromagnetic waves,which are expected to be used in low-frequency com... The perturbation in the magnetic field generated by the rotation or oscillation of magnetic domains in magnetic materials can emit low-frequency electromagnetic waves,which are expected to be used in low-frequency communications.However,the magnetic emission intensity,defined by the perturbation ability,of current commercially applied amorphous alloys,such as Metglas,cannot meet the application requirements for low-frequency antennas due to the domain motion energy loss.Herein,a multi-phase Metglas amorphous alloy was constructed by incorporatingα-Fe nanocrystals using rapid annealing to manipulate the domain movement.It was found that 3.89 times higher magnetic emission intensity is obtained compared to the pristine due to the synergism of the deformation and displacement mechanisms.Moreover,the low-frequency magnetic emission performance verification was carried out by preparing magnetoelectric composites as the antenna vibrator by assembling the alloy and macro piezoelectric fiber composites(MFC).Enhancements of magnetic emission intensity are found at 93.3%and 49.2%at the first and second harmonic frequencies compared with the unmodified alloy vibrator.Therefore,the approach leads to the development of high-performance communication with a novel standard for evaluation. 展开更多
关键词 multi-phase amorphous alloys magnetic emission intensity enhancing mechanism magnetic domain pinning theory Jiles-Atherton model analysis
原文传递
Low overhead design-for-testability for scan-based delay fault testing 被引量:3
15
作者 Yang Decai Chen Guangju Xie Yongle 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2007年第1期40-44,共5页
An efficient design-for-testability (DFT) technique is proposed to achieve low overhead for scan-based delay fault testing. Existing techniques for delay test such as skewed-load or broadside make the test generatio... An efficient design-for-testability (DFT) technique is proposed to achieve low overhead for scan-based delay fault testing. Existing techniques for delay test such as skewed-load or broadside make the test generation process complex and produce lower coverage for scan-based designs as compared with non-scan designs, whereas techniques such as enhanced-scan test can make the test easy but need an extra holding latch to add substantial hardware overhead. A new tri-state holding logic is presented to replace the common holding latch in enhanced-scan test to get a substantial low hardware overhead. This scheme can achieve low delay overhead by avoiding the holding latch on the critical timing scan path. What's more, this method can also keep the state and signal activity in the combinational circuit from the scan during data scan-in operation to reduce the power dissipation. Experiment results on a set of ISCAS89 benchmarks show the efficiency of the proposed scheme. 展开更多
关键词 Delay fault testing Design for testability enhanced scan
下载PDF
Sixty-four MDCT achieves higher contrast in pancreas with optimization of scan time delay 被引量:1
16
作者 Tina Stuber Hans-Jürgen Brambs +1 位作者 Wolfgang Freund Markus S Juchems 《World Journal of Radiology》 CAS 2012年第7期324-327,共4页
AIM: To compare different multidetector computed tomography (MDCT) protocols to optimize pancreatic contrast enhancement. METHODS: Forty consecutive patients underwent contrast-enhanced biphasic MDCT (arterial and por... AIM: To compare different multidetector computed tomography (MDCT) protocols to optimize pancreatic contrast enhancement. METHODS: Forty consecutive patients underwent contrast-enhanced biphasic MDCT (arterial and portalvenous phase) using a 64-slice MDCT. In 20 patients, the scan protocol was adapted from a previously used 40-channel MDCT scanner with arterial phase scanning initiated 11.1 s after a threshold of 150 HU was reached in the descending aorta, using automatic bolus tracking (Protocol 1). The 11.1-s delay was changed to 15 s in the other 20 patients to reflect the shorter scanning times on the 64-channel MDCT compared to the previous 40-channel system (Protocol 2). HU values were measured in the head and tail of the pancreas in the arterial and portal-venous phase. RESULTS: Using an 11.1-s delay, 74.2 HU (head) were measured on average in the arterial phase and 111.2 HU (head) were measured using a 15-s delay (P <0.0001). For the pancreatic tail, the average attenuation level was 76.73 HU (11.1 s) and 99.89 HU (15 s) respectively (P = 0.0002). HU values were also significantly higher in the portal-venous phase [pancreatic head: 70.5 HU (11.1 s) vs 84.0 HU (15 s) (P = 0.0014); pancreatic tail: 67.45 HU (11.1 s) and 77.18 HU (15 s) using Protocol 2 (P = 0.0071)]. CONCLUSION: Sixty-four MDCT may yield a higher contrast in pancreatic study with (appropriate) optimization of scan delay time. 展开更多
关键词 COMPUTED tomography PANCREAS scan delay Protocol CONTRAST enhancement
下载PDF
A Text Image Watermarking Algorithm Based on Image Enhancement 被引量:1
17
作者 Baowei Wang Luyao Shen +2 位作者 Junhao Zhang Zenghui Xu Neng Wang 《Computers, Materials & Continua》 SCIE EI 2023年第10期1183-1207,共25页
Digital watermarking technology is adequate for copyright protection and content authentication.There needs to be more research on the watermarking algorithm after printing and scanning.Aiming at the problem that exis... Digital watermarking technology is adequate for copyright protection and content authentication.There needs to be more research on the watermarking algorithm after printing and scanning.Aiming at the problem that existing anti-print scanning text image watermarking algorithms cannot take into account the invisibility and robustness of the watermark,an anti-print scanning watermarking algorithm suitable for text images is proposed.This algorithm first performs a series of image enhancement preprocessing operations on the printed scanned image to eliminate the interference of incorrect bit information on watermark embedding and then uses a combination of Discrete Wavelet Transform(DWT)-Singular Value Decomposition(SVD)to embed the watermark.Experiments show that the average Normalized Correlation(NC)of the watermark extracted by this algorithm against attacks such as Joint Photographic Experts Group(JPEG)compression,JPEG2000 compression,and print scanning is above 0.93.Especially,the average NC of the watermark extracted after print scanning attacks is greater than 0.964,and the average Bit Error Ratio(BER)is 5.15%.This indicates that this algorithm has strong resistance to various attacks and print scanning attacks and can better take into account the invisibility of the watermark. 展开更多
关键词 Print-resistant scanning image enhancement DWT SVD embedding intensity
下载PDF
Utility of positron emission tomography-computed tomography scan in detecting residual hepatocellular carcinoma post treatment:Series of case reports 被引量:2
18
作者 Jason T Cheng Nelly E Tan Michael L Volk 《World Journal of Gastrointestinal Oncology》 SCIE CAS 2020年第3期358-364,共7页
BACKGROUND Multi-phase computed tomography(CT)or magnetic resonance imaging(MRI)has been the standard of care for hepatocellular carcinoma(HCC)diagnosis for years.CASE SUMMARY We report a case series of four patients ... BACKGROUND Multi-phase computed tomography(CT)or magnetic resonance imaging(MRI)has been the standard of care for hepatocellular carcinoma(HCC)diagnosis for years.CASE SUMMARY We report a case series of four patients in whom positron emission tomographycomputed tomography(PET-CT)scan complemented the conventional CT/MRI scans in evaluating treatment response.In these four cases the conventional multi-phase CT and MRI failed to identify residual HCC disease post-treatment,while PET-CT complemented and aided in treatment response evaluation.In each case,the addition of PET-CT identified and located residual HCC disease,allowed retreatment,and altered medical management.CONCLUSION This case series suggests that PET-CT should perhaps play a role in the HCC management algorithm,in addition to the conventional contrast-enhanced multiphase scans. 展开更多
关键词 Hepatocellular carcinoma Positron emission tomography Contrast-enhanced multiphase scan CIRRHOSIS Residual cancer Treatment response evaluation Case series
下载PDF
CT增强扫描灰度直方图纹理分析技术对肺癌患者术前恶性程度评估及对预后的预测价值
19
作者 毛宇 黎明 +3 位作者 乔文婷 郭剑峰 李容波 白艳艳 《中国CT和MRI杂志》 2024年第5期79-82,共4页
目的探究CT增强扫描灰度直方图纹理分析技术对肺癌患者术前恶性程度评估及对预后的预测价值。方法选择2018年5月至2022年9月在我院就诊的且经术后病理证实的肺癌患者580例作为研究对象。依据术后病理分期,将研究对象分为高分化组(183例... 目的探究CT增强扫描灰度直方图纹理分析技术对肺癌患者术前恶性程度评估及对预后的预测价值。方法选择2018年5月至2022年9月在我院就诊的且经术后病理证实的肺癌患者580例作为研究对象。依据术后病理分期,将研究对象分为高分化组(183例)、中分化组(195例)、低分化组(202例)。根据预后情况,将其分为预后良好组(356例)和预后不良组(224例)。由2名医师提取患者CT增强扫描灰度直方图纹理参数。受试者工作特征(receiver operating characteristic,ROC)曲线分析特征参数对肺癌患者术前恶性程度的诊断效能及预后的预测价值。多因素Logistic回归分析预后不良的重要影响因素并构建人工神经网络模型。Pearson分析检验参数间的相关性。结果均值、10%分位、50%分位等参数在高、中、低分化三组中有显著差异。三个参数对评估肺癌患者恶性程度均具有一定的诊断效能,且三者联合诊断效能最佳。均值、10%分位、50%分位是预后不良的保护因素,三者联合预测肺癌患者的曲线AUC值大于各指标单独预测的AUC值。ROC曲线和累积增益图表明该模型预测能力良好。纹理特征参数中,69.44%的参数具有相关性。结论CT增强扫描灰度直方图纹理参数在一定程度上反应肺癌患者术前恶性程度信息,给术前预测以及预后提供了重要方法。 展开更多
关键词 肺癌 CT增强扫描 灰度直方图 纹理分析
下载PDF
CT增强检查中碘对比剂外渗病人皮肤损伤风险预测模型的构建
20
作者 梁俊丽 黄红芳 +2 位作者 陈秀珍 潘锡屏 施黎黎 《护理研究》 北大核心 2024年第18期3344-3348,共5页
目的:探讨CT增强检查中碘对比剂外渗病人皮肤损伤发生风险的影响因素,构建并验证风险预测模型。方法:采用便利抽样法抽取2023年1月—7月在广西医科大学第一附属医院放射科接受CT增强检查的碘对比剂外渗病人286例作为研究对象,自制CT增... 目的:探讨CT增强检查中碘对比剂外渗病人皮肤损伤发生风险的影响因素,构建并验证风险预测模型。方法:采用便利抽样法抽取2023年1月—7月在广西医科大学第一附属医院放射科接受CT增强检查的碘对比剂外渗病人286例作为研究对象,自制CT增强检查碘对比剂外渗病人皮肤损伤风险调查问卷对病人进行调查,采用单因素分析、Logistic回归分析筛选CT增强检查中碘对比剂外渗病人皮肤损伤发生风险的影响因素,构建风险预测模型,绘制列线图,运用受试者工作特征(ROC)曲线、校准曲线评价模型。结果:CT增强检查中碘对比剂外渗病人皮肤损伤发生率为18.5%。Logistic回归分析结果显示,过敏史、碘对比剂黏稠度、碘对比剂注射速度是CT增强检查中碘对比剂外渗病人皮肤损伤的影响因素(P<0.05),基于上述结果构建的预测模型建模组ROC曲线下面积为0.842[95%CI(0.770,0.915)],约登指数为0.667,最优截断值灵敏度为0.893,特异度为0.774;验证组ROC曲线下面积为0.924[95%CI(0.872,0.975)],约登指数为0.793,最优截断值灵敏度为0.891,特异度为0.902。Hosmer-Lemeshow检验结果显示,χ2=9.566,P=0.221 5,校准曲线与参考线相接近。结论:CT增强检查中碘对比剂外渗病人皮肤损伤风险预测模型预测效能良好,可为医务人员制订个性化的预防措施提供参考。 展开更多
关键词 CT增强扫描 碘对比剂 外渗 皮肤损伤 风险预测模型 影响因素 列线图 护理
下载PDF
上一页 1 2 91 下一页 到第
使用帮助 返回顶部