期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Multilayer Membranes Based on Ceramic Materials——Sol-gel Synthesis,Characterization and Membrane Performance
1
作者 Sun Qianyao Xu Chunming 《Petroleum Science》 SCIE CAS CSCD 2007年第4期80-88,共9页
In nearly all chemical and petrochemical systems, separation of products generally accounts for more than 50% of the capital cost and the greatest part of the energy consumption. It is generally believed that membrane... In nearly all chemical and petrochemical systems, separation of products generally accounts for more than 50% of the capital cost and the greatest part of the energy consumption. It is generally believed that membrane systems can offer benefits in both reducing the energy consumption of the separation stages and lowering the capital expenditure (CAPEX). Microporous ceramic membranes have the potential to overcome the limitation in polymer membranes operation, which has been the subject of a large amount of research worldwide in the last two decades. And most of the research has aimed at the production of the asymmetric multilayered membrane based on amorphous oxides by sol-gel techniques. The paper is to give an overview of publications on ceramic membranes, including less common materials of titania, zirconia, which can be used for pervaporation in corrosive media. Commercially available microporous membranes based on these membrane materials and the membrane economics are also summarized. 展开更多
关键词 multilayer membranes ceramic membranes sol-gel synthesis PERVAPORATION membrane performance
下载PDF
STUDIES ON RELATION BETWEEN INTRINSIC VISCOSITY OF POLYELECTROLYTES IN SOLUTIONS USED FOR LAYER-BY-LAYER SELFASSEMBLY AND THEIR CORRESPONDING ADSORPTION AMOUNTS IN THE RESULTANT MULTILAYER MEMBRANES
2
作者 钱锦文 安全福 Phillip Choi 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2009年第3期297-306,共10页
The adsorption amount of poly(styrene sulfonate) and poly(dimethyldiallyl ammonium chloride) (PSS/PDDA) self-assembled multilayer membranes in designed dipping solvents were measured by UV-Vis-spectroscopy and quartz ... The adsorption amount of poly(styrene sulfonate) and poly(dimethyldiallyl ammonium chloride) (PSS/PDDA) self-assembled multilayer membranes in designed dipping solvents were measured by UV-Vis-spectroscopy and quartz crystal microbalance (QCM). Intrinsic viscosities of PSS and PDDA in corresponding dipping solvents were determined by an Ubbelohde viscometer. It is found that the adsorption amount of PSS/PDDA self-assembled multilayer membranes built up in different dipping solutions, added salt concentration, pH of solution and solvent quality, respectively changed oppositely with the corresponding intrinsic viscosity of PSS and PDDA in dipping solvents. A negative relation between the adsorption amount and intrinsic viscosity was revealed, and explained in term of the concept of excluded volume of polymer molecule in dilute solutions. 展开更多
关键词 Self-assembled multilayer membrane PSS/PDDA Polyelectrolyte solution Intrinsic viscosity
下载PDF
A Totally Absorbable Multilayer PLGA Implant Device Containing Doxorubicin Inhibited Tumor Growth and Metastasis without Systemic Toxicity in Murine Breast Cancer and an Ideal Pharmacological Paradigm for Regional Chemotherapy
3
作者 Bennett Elzey Sandra Torregrosa-Allen +2 位作者 Peterson Li Ben Ramsey Matthew Shaw 《Journal of Biosciences and Medicines》 2016年第7期66-81,共17页
We hypothesize that a cylinder implant made of multilayer Poly-lactic-co-glycolic-acid (PLGA) membrane can be a method for controlled and extended drug release. We fashioned a multilayer cylindrical implant termed STI... We hypothesize that a cylinder implant made of multilayer Poly-lactic-co-glycolic-acid (PLGA) membrane can be a method for controlled and extended drug release. We fashioned a multilayer cylindrical implant termed STID100 that released doxorubicin for 3 weeks in an orthotopic 4T1 breast cancer model in Balb/C mice. This implant starts as a thin doxorubicin-embedded PLGA membrane, and is then rolled into a cylinder containing an air gap between the membrane layers. Its controlled sustained release delivered 2× the amount of the intravenous (IV) equivalent of doxorubicin, inhibited the primary tumor, and prevented lung metastasis. Importantly it did not cause weight loss, splenomegaly, or cardiac toxicity vs systemically administrated doxorubicin. This favorable safety profile is further substantiated by the finding of no detectable plasma doxorubicin in multiple time points during the 3-week period, and low tumor doxorubicin concentration. The implant system delivered to the specification of an ideal pharmacological paradigm might offer a better coverage of the local tumor, significantly preventing metastatic spread with less drug toxicity to many vital organs, compared to the traditional pharmacology of IV route. The profile of STID made it an attractive therapeutic alternative in metastatic tumor prevention, pain management and many other diverse clinical scenarios. 展开更多
关键词 PLGA DOXORUBICIN IMPLANT multilayer membrane METASTASIS Controlled Release Extended Release Polymer Tumor Breast Cancer Mice Regional Chemotherapy Pharmacology
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部