The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resista...The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resistances. To study the energy spectrum, a four-channel diode X-ray spectrometer was used along with a special set of filters. The filters were suitable for detection of medium range X-rays as well as hard X-rays with energy exceeding 30 keV. The results indicate that the anomalous resistivity effect during the post pinch phase may cause multi-radiation of X-rays with a total duration of 300 ± 50 ns. The significant contribution of Cu-Kα was due to the medium range X-rays, nonetheless, hard X-rays with energies greater than 15 keV also participate in the process. The total emitted X-ray energy in the forms of Cu-K and Cu-K/3 was around 0.14 ± 0.02 (J/Sr) and 0.04 ±0.01 (J/Sr), respectively. The total energy of the emitted hard X-ray (〉 15 keV) was around 0.12± 0.02 (J/Sr).展开更多
DAR (diffusion absorption refrigeration) cycle is driven by heat and has no moving parts. It is based on refrigerant and absorbent as the working fluid together with hydrogen as an auxiliary inert gas. To circulate ...DAR (diffusion absorption refrigeration) cycle is driven by heat and has no moving parts. It is based on refrigerant and absorbent as the working fluid together with hydrogen as an auxiliary inert gas. To circulate the working fluid without a mechanical pump, the diffusion absorption cycle relies on a bubble pump. Experimental system was designed and operated. Its aim was to investigate the performance of a bubble pump operating with three lifting tubes. The experimental results of the system were compared to existing models. The comparison showed that there was a bad agreement between the experimental and the theoretical results.展开更多
文摘The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resistances. To study the energy spectrum, a four-channel diode X-ray spectrometer was used along with a special set of filters. The filters were suitable for detection of medium range X-rays as well as hard X-rays with energy exceeding 30 keV. The results indicate that the anomalous resistivity effect during the post pinch phase may cause multi-radiation of X-rays with a total duration of 300 ± 50 ns. The significant contribution of Cu-Kα was due to the medium range X-rays, nonetheless, hard X-rays with energies greater than 15 keV also participate in the process. The total emitted X-ray energy in the forms of Cu-K and Cu-K/3 was around 0.14 ± 0.02 (J/Sr) and 0.04 ±0.01 (J/Sr), respectively. The total energy of the emitted hard X-ray (〉 15 keV) was around 0.12± 0.02 (J/Sr).
文摘DAR (diffusion absorption refrigeration) cycle is driven by heat and has no moving parts. It is based on refrigerant and absorbent as the working fluid together with hydrogen as an auxiliary inert gas. To circulate the working fluid without a mechanical pump, the diffusion absorption cycle relies on a bubble pump. Experimental system was designed and operated. Its aim was to investigate the performance of a bubble pump operating with three lifting tubes. The experimental results of the system were compared to existing models. The comparison showed that there was a bad agreement between the experimental and the theoretical results.