●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria...●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.展开更多
AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL...AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.METHODS:In this retrospective case series,32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter(D).A plate haptic toric IOL(AT Torbi 709M,Carl Zeiss Meditec AG)was implanted in all eyes.The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity(BCVA).RESULTS:Preoperative refractive astigmatism was 2.14±1.17 D,which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period(0.67±0.44 D at three months and 0.75±0.25 D at six months;for all groups:P<0.0001 compared to baseline).BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery(P=0.02).Mean IOL axis deviation from the target axis was 3.4°±2.9°after six to eight weeks and significantly decreased over time(2.4°±2.6°six months after surgery;P=0.04).In one patient IOL,re-alignment was performed.CONCLUSION:Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.The plate haptic toric IOL position and axis remain stable during the observation period of six months.展开更多
The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract sur...The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract surgery in diabetic patients poses many challenges:Poor epithelial healing,decreased corneal sensitivity,increased central corneal thickness,decreased endothelial cell count,variable topography,poor pupillary dilatation,anterior capsular phimosis,posterior capsular opacification(PCO),chances of progression of diabetic retinopathy(DR),zonular weakness,and vitreous prolapse and diabetic macular edema.Selection of an appropriate intraocular lens(IOL)is crucial for visual rehabilitation and monitoring DR.The choice of IOL in diabetic cataract patients is a challenging scenario.Square-edge IOLs are favored for their capacity to mitigate PCO,whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR.The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation,particularly in the presence of advanced retinopathy.Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications.Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes.This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population.展开更多
Purpose: To compare vision quality following phacoemulsification cataract extraction and implantation of a Big Bag or Akreos Adapt intraocular lens(IOL) in patients diagnosed with high myopia complicated with cataract...Purpose: To compare vision quality following phacoemulsification cataract extraction and implantation of a Big Bag or Akreos Adapt intraocular lens(IOL) in patients diagnosed with high myopia complicated with cataract.Methods:.This was a randomized prospective control study.The patients with high myopia complicated with cataract, with axial length ≥28 mm,.and corneal astigmatism ≤1D were enrolled and randomly divided into the Big Bag and Akreos Adapt IOL groups. All patients underwent phacoemulsification cataract extraction and lens implantation..At 3 months after surgery,.intraocular high-order aberration was measured by a Tracey-i Trace wavefront aberrometer at a pupil diameter of 5mm in an absolutely dark room and statistically compared between two groups. The images of the anterior segment of eyes were photographed with a Scheimpflug camera using Pentacam three-dimensional anterior segment analyzer..The tilt and decentration of the IOL were calculated by Image-pro plus 6.0imaging analysis software and statistically compared between two groups.Results:.In total,.127 patients(127 eyes),..including 52 males and 75 females, were enrolled in this study. The total high-order aberration and coma in the Akreos Adapt group(59 eyes)were significantly higher compared with those in the Big Bag(P <0.05)..The clover and spherical aberration did not differ between the two groups(P>0.05). The horizontal and vertical decentration were significantly smaller in the Big Bag lens group than in the Akreos Adapt group(both P<0.05), whereas the tilt of IOL did not significantly differ between the two groups(P>0.05).Conclusion:.Both Big Bag and Akreos Adapt IOLs possess relatively good intraocular stability implanted in patients with high myopia. Compared with the Akreos Adapt IOL, the Big Bag IOL presents with smaller intraocular high-order aberration. Coma is the major difference between the two groups.展开更多
AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who...AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who received sulcus-placed SPA-IOLs between 2006 and 2009 were reviewed. None of the patients underwent IOL exchange. Charts of six age-matched patients who received sulcus placed 3P-IOLs were reviewed as a control group. RESULTS: Mean follow up was 16 mo for SPA-IOL and 23 mo for 3P-IOL. Five of 8 patients in the SPA-IOL group required chronic use of IOP lowering medications at final follow up. Of these, one patient needed glaucoma implant surgery for uncontrolled IOP. One patient in the 3P-IOL group used chronic aqueous suppression pre- and postoperatively. Four of eight eyes with SPAIOL were treated with chronic topical steroids and or non-steroidal anti-inflammatory drugs for cystoid macu-la edema, chronic uveitis, pigment dispersion syndrome or a combination of the above, compared to none in the control group. Mean best-corrected visual acuity was 20/35 in the SPA-IOL group and 20/47 in the 3PIOL group.CONCLUSION: Sulcus placed SPA-IOLs are associated with increased ocular morbidity. In select cases good visual acuity may be achieved. Due to postoperative rotation of sulcus placed toric SPA-IOLs stable astigmatism correction cannot be achieved. Alternative intraocular lenses should be considered when in-the-bag placement of SPA-IOL is not possible.展开更多
Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number...Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number of focal points that each lens provides,which in turn leads to different visual outcomes.Familiarity of surgeons with the various characteristics of each lens is of utmost importance for accurate IOL selection to match each patient’s needs.In this review,we aim to compare the clinical outcomes after implantation of multifocal and EDOF IOLs in terms of distance,intermediate and near vision,contrast sensitivity,and reading performance.Finally,we discuss the defocus curve and the optical and photic phenomena associated with each type of IOL.展开更多
AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A t...AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A total of 80 eyes of 40 patients were included in this prospective study.Twenty patients in each group were implanted with trifocal toric and bifocal toric IOL,respectively.Preoperative and postoperative 6-month measurements were recorded for both patient groups.Comprehensive anterior and posterior segment examinations,distance-intermediate-near visual acuity values and the visual function scale questionnaire results were evaluated at these examinations.Patient satisfaction,contrast sensitivity,glare,intermediate-near and distance stereopsis and IOL rotation were also evaluated.RESULTS:No significant difference was found between the groups in terms of distance and near visual acuities(P=0.269,P=0.451).Intermediate visual acuity was significantly increased in the trifocal toric group(P<0.001).The visual function scale results were increased after surgery in both groups(P=0.001 and P<0.001),with no difference determined between them(P=0.158 and P=0.691).The number of patients wearing glasses was low in both groups and there was no significant difference between the groups(P>0.05).The overall satisfaction in the trifocal toric group was significantly higher than in the bifocal toric group(P=0.03).The highest sensitivity was observed at 6 cpd spatial frequency in all patients under photopic conditions(1.80±0.24 logU,1.74±0.20 logU).Distance-intermediate-near binocular depth perception results in both groups were higher in the trifocal toric group(P=0.02,0.048,0.003,respectively).Although there was no significant difference for 3 meters stereopsis,the trifocal toric group had higher depth perception(P=0.577).Mean rotation was 5.76°±3.93°in the trifocal toric group and 12°±7.1°in the bifocal toric group.CONCLUSION:Better results in the middle distance are obtained in the trifocal toric group and less IOL rotation due to digital system-coordinated surgery.Moreover,the overall satisfaction in the trifocal toric group is significantly higher than in the bifocal toric group.展开更多
·AIM: To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting,monofocal intraocular lens(IOL).·METHODS: Twent...·AIM: To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting,monofocal intraocular lens(IOL).·METHODS: Twenty-one patients(34 eyes) aged 50 to83 y underwent cataract surgery with implantation of an aspheric, aberration correcting IOL(Tecnis ZCB00,Abbott Medical Optics). Three months after surgery they were examined for uncorrected(UDVA) and corrected distance visual acuity(CDVA), contrast sensitivity(CS)under photopic and mesopic conditions with and without glare source, ocular high order aberrations(HOA, Zywave II) and retinal straylight(C-Quant).· RESULTS: Postoperatively, patients achieved a postoperative CDVA of 0.0 log MAR or better in 97.1% of eyes. Mean values of high order abberations were +0.02±0.27(primary coma components) and-0.04 ±0.16(spherical aberration term). Straylight values of the C-Quant were 1.35±0.44 log which is within normal range of age matched phakic patients. The CS measurements under mesopic and photopic conditions in combination with and without glare did not show any statistical significance in the patient group observed(P ≥0.28).· CONCLUSION: The implantation of an aspherical aberration correcting monofocal IOL after cataractsurgery resulted in very low residual higher order aberration(HOA) and normal straylight.展开更多
AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty...AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses.展开更多
AIM:To evaluate the efficacy,safety and stability of posterior chamber phakic intraocular lens implantation for the correction of high myopia.METHODS:Retrospective case review of 82 eyes(43patients)undergoing implanta...AIM:To evaluate the efficacy,safety and stability of posterior chamber phakic intraocular lens implantation for the correction of high myopia.METHODS:Retrospective case review of 82 eyes(43patients)undergoing implantable Coliamer lens(ICL)placement by a single surgeon(Xiao-Wei Gao)to correct preoperative mean spherical equivalents between-9.00diopter(D)and-23.00D.Main outcome measures included uncorrected visual acuity(UCVA),refraction,best spectacle-corrected visual acuity(BSCVA),endothelial cell density(ECD),intraocular pressure(IOP),lens transparency,postoperative uveitis.Visante anterior segment optical coherence tomography(AS-OCT)was used to measure anterior chamber depth(ACD)and the position of ICL.RESULTS:Mean follow-up was 6.54±3.26 months(range 3-12 months).Predictability of the manifest spherical equivalent(SE)refraction to within±1.OOD was achieved in 88%of eyes and±0.50D in 72.5%of eyes.The mean postoperative manifest SE refraction was-1.85±0.72D,with 96.34%of eyes maintaining or gaining≥1 line(s)of BSCVA.The mean 3-month postoperative ECD decreased but had no statistically difference compared with the preoperative ECD.Of the 7 eyes(8.54%)with a mild transient increase in intraocular pressure(up to 30mmHg),none required a second surgical procedure or prolonged topical medication.There was no loss of lens transparency.Pigmented precipitates were observed in 5 eyes(6.09%).The mean preoperative ACD measured with AS-OCT was 3.28±0.14mm,three months after surgery,the mean ACD was2.45±0.22mm.Anterior chamber depth showed astatistically significant reduction.One eye(1.22%)had ICL spontaneous rotation,81 eyes(98.78%)of the lens remained correctly centered.CONCLUSION:The implantation of ICL is an effective surgical option for the management of high myopia.But its long time effect and safety still need more time to prove.展开更多
Posterior capsule opacification(PCO) remains the most common complication of pediatric cataract surgery despite continuous efforts to reduce its incidence. For this reason, pediatric cataract surgeons have expended ...Posterior capsule opacification(PCO) remains the most common complication of pediatric cataract surgery despite continuous efforts to reduce its incidence. For this reason, pediatric cataract surgeons have expended considerable effort into preventing and mitigating PCO. The intraocular lens(IOL) optic capture technique has been used for the prevention of PCO after pediatric cataract surgery for more than 20 y, but there is still no professional consensus. However, recent research has shown encouraging results. The IOL optic capture technique can be performed without anterior vitrectomy to prevent PCO, even in younger children. The type and characteristics of IOLs used for optic capture technique, the location of IOL and the complications of IOL optic capture in children are here reviewed.展开更多
This study evaluated the safety of a modified method to implant an intraocular lens (IOL) into the capsular bag immediately after capsulorhexis with a whole or partial nucleus to protect the posterior capsule (PC) dur...This study evaluated the safety of a modified method to implant an intraocular lens (IOL) into the capsular bag immediately after capsulorhexis with a whole or partial nucleus to protect the posterior capsule (PC) during phacoemulsification in a series of 12 Morgagnian cataracts. For 3 cases of hypermature cataracts with smaller and rigid nuclei, after a complete capsulorhexis, an IOL was directly inserted into the capsular bag, which protected the PC during the subsequent phacoemulsification process in the iris plate. For the other 9 cases with larger and softer nuclei, after the nucleus was partially emulsified, the IOL was inserted into the bag. Even with an obvious surge for some cases, the surgeries were uneventful in all 12 cases, with no PC rent or vitreous loss. IOL implantation into the capsular bag with a whole or partial nucleus can provide effective protection for the PC for hypermature cataract during phacoemulsification.展开更多
The study was to report a new two-point scleralfixation technique for foldable intraocular lenses with four haptics.Lenses were slid into the anterior chamber from a 2.8 mm corneal incision and fixed under two sclera ...The study was to report a new two-point scleralfixation technique for foldable intraocular lenses with four haptics.Lenses were slid into the anterior chamber from a 2.8 mm corneal incision and fixed under two sclera flaps at two opposite points.The postoperative best-corrected visual acuities(BCVAs) of all patients were significantly better than their preoperative BCVA.The results demonstrate that two-point,scleral fixations of foldable,intraocular lenses might be practicable and effective.展开更多
At present, the incidence of infectious endophthalmitis after cataract surgery has been significantly reduced, but it is still a serious complication. Removal or not of the intraocular lens(IOL) during vitrectomy in c...At present, the incidence of infectious endophthalmitis after cataract surgery has been significantly reduced, but it is still a serious complication. Removal or not of the intraocular lens(IOL) during vitrectomy in cases with a moderate or severe inflammation is controversial. In order to call upon more discussion, we publish the article entitled “Timely vitrectomy without intraocular lens removal for acute endophthalmitis after cataract surgery” written by Guo et al in this issue. With recent advanced vitrectomy techniques, and critical measures for management of risk factors related to occurrence of infection, IOL remaining during timely vitrectomy for acute endophthalmitis can possibly be safe and effective in selected cases.展开更多
AIM: To assess the safety, efficacy and predictability of the AcrySof phakic angle-supported intraocular lens (IOL) (Alcon Inc., U.S.A.) for correction of high-to-extremely high myopia in adults. METHODS: In this pros...AIM: To assess the safety, efficacy and predictability of the AcrySof phakic angle-supported intraocular lens (IOL) (Alcon Inc., U.S.A.) for correction of high-to-extremely high myopia in adults. METHODS: In this prospective study performed in Tianjin Medical University Eye Center & College of Optometry, Tianjin, China, 25 eyes of 13 patients were implanted with AcrySof phakic angle-supported IOLs and followed for 1 year postoperatively. Preoperative manifest refractive sphere was (-12.08 +/- 2.44) diopters (D) and cylinder was (-1.35 +/- 0.62)D. Visual acuity, predictability and stability of manifest refraction spherical equivalent (MRSE), adverse events, and endothelial cell density were analyzed during 1-year of follow-up. RESULTS: After 1 year of follow-up, no eyes lost 1 line (best spectacle-corrected visual acuity)BSCVA; an uncorrected visual acuity (UCVA) of 20/20 or better was achieved in 60% of eyes; 100% had an UCVA of 20/40 or better; a BSCVA of 20/30 or better was achieved by 100% of eyes; 84% had a BSCVA of 20/20 or better. The overall mean percentage change in endothelial cell density 1 year after surgery was (-0.27 +/- 3.60)%. Two eyes (8%) had increased intraocular pressure (IOP) on the day of surgery. No pupil ovalization, pupillary block, or retinal detachment events were observed. CONCLUSION: After 1 year of follow-up, the implantation of AcrySof phakic angle-supported IOL is proved to be safe, effective and predictable with minimal complications in patients with high-to-extremely high myopia. Due to the limitation of visiting time, long-term of clinical investigation is necessary to verify the safety and efficacy of this IOL.展开更多
AIM:To assess patients’ visual performance with glistenings in one piece soft hydrophobic acrylic intraocular lenses(IOLs)(Alcon)2y postoperatively.METHODS:This cross section trial included 120 eyes with one piece IO...AIM:To assess patients’ visual performance with glistenings in one piece soft hydrophobic acrylic intraocular lenses(IOLs)(Alcon)2y postoperatively.METHODS:This cross section trial included 120 eyes with one piece IOL at 2y postoperatively.Glistening was classified in 4 groups,ranging from 0(none)to 3(most evident)according to their severity in IOLs optics observed under a slit lamp.All eyes underwent a uncorrected and best-corrected visual acuity evaluation(UCVA and BCVA,LogMAR scale),a complete clinical examination,a contrast sensitivity(CS)evaluation by F.A.C.T chart,and a visual field test by Humphrey Field AnalyzerⅡ(HFA).One-way ANOVA was used for quantitative data,while Pearsonχ2test was used for qualitative data to analyze the visual function of 4glistening groups.RESULTS:Totally 120 eyes were enrolled with 30 eyes in each glistening group.There was no statistical correlation between glistening grades and patients’age,IOLs power,postoperative UCVA and BCVA(P】0.05).Quantificationally,CS values among each group were not statistically different.However,qualitative analysis showed there were more eyes in grade 3 group than in grade 0 group having abnormally declined CS at high spatial frequency(10%vs 36.7%at 18 cpd,P=0.029;6.7%vs 26.7%at 12 cpd,P=0.013).Mean deviation(MD)of the visual field test was-2.14±2.31,-1.97±2.23,-3.02±3.17,-4.12±3.38 in group 0 to 3 respectively.There was a significant decrease in the most serious glistenings group(P=0.018).CONCLUSION:Glistenings may potentially have an impact on contrast sensitivity at high spatial frequency and MD in visual field test.展开更多
Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patien...Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patient with extrahigh myopia from implantable collamer lens (ICL) to trifocal intraocular lens (IOL) implantation.展开更多
AIM: To assess the binocular visual function in bilateral cataract patients with unilateral astigmatism after combined implantations of Toric with multifocal intraocular lens (IOL), and to compare with that of Tori...AIM: To assess the binocular visual function in bilateral cataract patients with unilateral astigmatism after combined implantations of Toric with multifocal intraocular lens (IOL), and to compare with that of Toric and monofocal IOL implantation.METHODS: All the 30 patients with unilateral astigmatism suffered bilateral cataract were randomly divided into two groups: Toric plus multifocal IOL group and Toric plus monofocal IOL group. Uncorrected and corrected visual acuity at distance (5.0 m), intermediate distance (0.6 m), and near (0.33 m), contrast sensitivity, and stereopsis were assessed 6mo after surgery. Patients were also surveyed for visual disturbances and spectacle dependence.RESULTS: Binocular uncorrected visual acuity (LogMAR) of Toric/multifocal IOL eyes at distance, intermediate, near were 0.05±0.05, 0.24±0.10, and 0.14±0.06 respectively. The values of Toric plus monofocal IOL eyes were 0.06±0.07, 0.26±0.08, and 0.37±0.10 respectively. These values did not indicate significant differences between two groups with exception of near visual acuity. In the photopic condition (with or without glare), the contrast sensitivity of multifocal IOL eyes was significant lower than the monofocal IOL eyes in 18 cpd. In the mesopic condition, the contrast sensitivity of multifocal group was significant lower than monofocal group in 12 cpd, and in mesopic glare condition, this significant difference was found both in 6 cpd and 12 cpd. The stereopsis of Toric/multifocal IOL eyes decreased slightly (100±80 seconds of arc, t=2.222, P=0.136). Mean near vision for patient satisfaction was statistically significantly higher in Toric/multifocal IOL group patients versus than that in Toric/monofocal IOL group (80% vs 25.5%, P=0.000). Visual disturbance was not noticed in either group.CONCLUSION: Although the combination of Toric and multifocal IOL implantation results in compromising stereoacuity, it can still provide patients with high levels of spectacle freedom and good overall binocular visual acuity.展开更多
文摘●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.
文摘AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.METHODS:In this retrospective case series,32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter(D).A plate haptic toric IOL(AT Torbi 709M,Carl Zeiss Meditec AG)was implanted in all eyes.The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity(BCVA).RESULTS:Preoperative refractive astigmatism was 2.14±1.17 D,which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period(0.67±0.44 D at three months and 0.75±0.25 D at six months;for all groups:P<0.0001 compared to baseline).BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery(P=0.02).Mean IOL axis deviation from the target axis was 3.4°±2.9°after six to eight weeks and significantly decreased over time(2.4°±2.6°six months after surgery;P=0.04).In one patient IOL,re-alignment was performed.CONCLUSION:Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.The plate haptic toric IOL position and axis remain stable during the observation period of six months.
文摘The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract surgery in diabetic patients poses many challenges:Poor epithelial healing,decreased corneal sensitivity,increased central corneal thickness,decreased endothelial cell count,variable topography,poor pupillary dilatation,anterior capsular phimosis,posterior capsular opacification(PCO),chances of progression of diabetic retinopathy(DR),zonular weakness,and vitreous prolapse and diabetic macular edema.Selection of an appropriate intraocular lens(IOL)is crucial for visual rehabilitation and monitoring DR.The choice of IOL in diabetic cataract patients is a challenging scenario.Square-edge IOLs are favored for their capacity to mitigate PCO,whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR.The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation,particularly in the presence of advanced retinopathy.Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications.Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes.This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population.
文摘Purpose: To compare vision quality following phacoemulsification cataract extraction and implantation of a Big Bag or Akreos Adapt intraocular lens(IOL) in patients diagnosed with high myopia complicated with cataract.Methods:.This was a randomized prospective control study.The patients with high myopia complicated with cataract, with axial length ≥28 mm,.and corneal astigmatism ≤1D were enrolled and randomly divided into the Big Bag and Akreos Adapt IOL groups. All patients underwent phacoemulsification cataract extraction and lens implantation..At 3 months after surgery,.intraocular high-order aberration was measured by a Tracey-i Trace wavefront aberrometer at a pupil diameter of 5mm in an absolutely dark room and statistically compared between two groups. The images of the anterior segment of eyes were photographed with a Scheimpflug camera using Pentacam three-dimensional anterior segment analyzer..The tilt and decentration of the IOL were calculated by Image-pro plus 6.0imaging analysis software and statistically compared between two groups.Results:.In total,.127 patients(127 eyes),..including 52 males and 75 females, were enrolled in this study. The total high-order aberration and coma in the Akreos Adapt group(59 eyes)were significantly higher compared with those in the Big Bag(P <0.05)..The clover and spherical aberration did not differ between the two groups(P>0.05). The horizontal and vertical decentration were significantly smaller in the Big Bag lens group than in the Akreos Adapt group(both P<0.05), whereas the tilt of IOL did not significantly differ between the two groups(P>0.05).Conclusion:.Both Big Bag and Akreos Adapt IOLs possess relatively good intraocular stability implanted in patients with high myopia. Compared with the Akreos Adapt IOL, the Big Bag IOL presents with smaller intraocular high-order aberration. Coma is the major difference between the two groups.
基金Supported by NIH Center Core,No.P30EY014801Research to Prevent Blindness Unrestricted Grant,Department of Defense,No.DOD-Grant#W81XWH-09-1-0675
文摘AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who received sulcus-placed SPA-IOLs between 2006 and 2009 were reviewed. None of the patients underwent IOL exchange. Charts of six age-matched patients who received sulcus placed 3P-IOLs were reviewed as a control group. RESULTS: Mean follow up was 16 mo for SPA-IOL and 23 mo for 3P-IOL. Five of 8 patients in the SPA-IOL group required chronic use of IOP lowering medications at final follow up. Of these, one patient needed glaucoma implant surgery for uncontrolled IOP. One patient in the 3P-IOL group used chronic aqueous suppression pre- and postoperatively. Four of eight eyes with SPAIOL were treated with chronic topical steroids and or non-steroidal anti-inflammatory drugs for cystoid macu-la edema, chronic uveitis, pigment dispersion syndrome or a combination of the above, compared to none in the control group. Mean best-corrected visual acuity was 20/35 in the SPA-IOL group and 20/47 in the 3PIOL group.CONCLUSION: Sulcus placed SPA-IOLs are associated with increased ocular morbidity. In select cases good visual acuity may be achieved. Due to postoperative rotation of sulcus placed toric SPA-IOLs stable astigmatism correction cannot be achieved. Alternative intraocular lenses should be considered when in-the-bag placement of SPA-IOL is not possible.
文摘Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number of focal points that each lens provides,which in turn leads to different visual outcomes.Familiarity of surgeons with the various characteristics of each lens is of utmost importance for accurate IOL selection to match each patient’s needs.In this review,we aim to compare the clinical outcomes after implantation of multifocal and EDOF IOLs in terms of distance,intermediate and near vision,contrast sensitivity,and reading performance.Finally,we discuss the defocus curve and the optical and photic phenomena associated with each type of IOL.
文摘AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A total of 80 eyes of 40 patients were included in this prospective study.Twenty patients in each group were implanted with trifocal toric and bifocal toric IOL,respectively.Preoperative and postoperative 6-month measurements were recorded for both patient groups.Comprehensive anterior and posterior segment examinations,distance-intermediate-near visual acuity values and the visual function scale questionnaire results were evaluated at these examinations.Patient satisfaction,contrast sensitivity,glare,intermediate-near and distance stereopsis and IOL rotation were also evaluated.RESULTS:No significant difference was found between the groups in terms of distance and near visual acuities(P=0.269,P=0.451).Intermediate visual acuity was significantly increased in the trifocal toric group(P<0.001).The visual function scale results were increased after surgery in both groups(P=0.001 and P<0.001),with no difference determined between them(P=0.158 and P=0.691).The number of patients wearing glasses was low in both groups and there was no significant difference between the groups(P>0.05).The overall satisfaction in the trifocal toric group was significantly higher than in the bifocal toric group(P=0.03).The highest sensitivity was observed at 6 cpd spatial frequency in all patients under photopic conditions(1.80±0.24 logU,1.74±0.20 logU).Distance-intermediate-near binocular depth perception results in both groups were higher in the trifocal toric group(P=0.02,0.048,0.003,respectively).Although there was no significant difference for 3 meters stereopsis,the trifocal toric group had higher depth perception(P=0.577).Mean rotation was 5.76°±3.93°in the trifocal toric group and 12°±7.1°in the bifocal toric group.CONCLUSION:Better results in the middle distance are obtained in the trifocal toric group and less IOL rotation due to digital system-coordinated surgery.Moreover,the overall satisfaction in the trifocal toric group is significantly higher than in the bifocal toric group.
文摘·AIM: To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting,monofocal intraocular lens(IOL).·METHODS: Twenty-one patients(34 eyes) aged 50 to83 y underwent cataract surgery with implantation of an aspheric, aberration correcting IOL(Tecnis ZCB00,Abbott Medical Optics). Three months after surgery they were examined for uncorrected(UDVA) and corrected distance visual acuity(CDVA), contrast sensitivity(CS)under photopic and mesopic conditions with and without glare source, ocular high order aberrations(HOA, Zywave II) and retinal straylight(C-Quant).· RESULTS: Postoperatively, patients achieved a postoperative CDVA of 0.0 log MAR or better in 97.1% of eyes. Mean values of high order abberations were +0.02±0.27(primary coma components) and-0.04 ±0.16(spherical aberration term). Straylight values of the C-Quant were 1.35±0.44 log which is within normal range of age matched phakic patients. The CS measurements under mesopic and photopic conditions in combination with and without glare did not show any statistical significance in the patient group observed(P ≥0.28).· CONCLUSION: The implantation of an aspherical aberration correcting monofocal IOL after cataractsurgery resulted in very low residual higher order aberration(HOA) and normal straylight.
文摘AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses.
文摘AIM:To evaluate the efficacy,safety and stability of posterior chamber phakic intraocular lens implantation for the correction of high myopia.METHODS:Retrospective case review of 82 eyes(43patients)undergoing implantable Coliamer lens(ICL)placement by a single surgeon(Xiao-Wei Gao)to correct preoperative mean spherical equivalents between-9.00diopter(D)and-23.00D.Main outcome measures included uncorrected visual acuity(UCVA),refraction,best spectacle-corrected visual acuity(BSCVA),endothelial cell density(ECD),intraocular pressure(IOP),lens transparency,postoperative uveitis.Visante anterior segment optical coherence tomography(AS-OCT)was used to measure anterior chamber depth(ACD)and the position of ICL.RESULTS:Mean follow-up was 6.54±3.26 months(range 3-12 months).Predictability of the manifest spherical equivalent(SE)refraction to within±1.OOD was achieved in 88%of eyes and±0.50D in 72.5%of eyes.The mean postoperative manifest SE refraction was-1.85±0.72D,with 96.34%of eyes maintaining or gaining≥1 line(s)of BSCVA.The mean 3-month postoperative ECD decreased but had no statistically difference compared with the preoperative ECD.Of the 7 eyes(8.54%)with a mild transient increase in intraocular pressure(up to 30mmHg),none required a second surgical procedure or prolonged topical medication.There was no loss of lens transparency.Pigmented precipitates were observed in 5 eyes(6.09%).The mean preoperative ACD measured with AS-OCT was 3.28±0.14mm,three months after surgery,the mean ACD was2.45±0.22mm.Anterior chamber depth showed astatistically significant reduction.One eye(1.22%)had ICL spontaneous rotation,81 eyes(98.78%)of the lens remained correctly centered.CONCLUSION:The implantation of ICL is an effective surgical option for the management of high myopia.But its long time effect and safety still need more time to prove.
文摘Posterior capsule opacification(PCO) remains the most common complication of pediatric cataract surgery despite continuous efforts to reduce its incidence. For this reason, pediatric cataract surgeons have expended considerable effort into preventing and mitigating PCO. The intraocular lens(IOL) optic capture technique has been used for the prevention of PCO after pediatric cataract surgery for more than 20 y, but there is still no professional consensus. However, recent research has shown encouraging results. The IOL optic capture technique can be performed without anterior vitrectomy to prevent PCO, even in younger children. The type and characteristics of IOLs used for optic capture technique, the location of IOL and the complications of IOL optic capture in children are here reviewed.
基金Supported by National Natural Science Foundation of China(No.81570830,No.81670817)Key R&D Program Projects in Shaanxi Province(No.2017SF-273)+2 种基金the Tianjin Research Program of Application Foundation and Advanced Technology(No.17JCYBJC27200)the Science&Technology Foundation for Selected Overseas Chinese Scholar,Bureau of Personnel of China,Tianjin,and Talent Innovation Group of 131,Bureau of Personnel,Tianjin,Tianjin Science and Technology Project(Popularization of Science 17KPHDSF00230)Xi’an Science and Technology Project [No.2017116SF/YX010(1)
文摘This study evaluated the safety of a modified method to implant an intraocular lens (IOL) into the capsular bag immediately after capsulorhexis with a whole or partial nucleus to protect the posterior capsule (PC) during phacoemulsification in a series of 12 Morgagnian cataracts. For 3 cases of hypermature cataracts with smaller and rigid nuclei, after a complete capsulorhexis, an IOL was directly inserted into the capsular bag, which protected the PC during the subsequent phacoemulsification process in the iris plate. For the other 9 cases with larger and softer nuclei, after the nucleus was partially emulsified, the IOL was inserted into the bag. Even with an obvious surge for some cases, the surgeries were uneventful in all 12 cases, with no PC rent or vitreous loss. IOL implantation into the capsular bag with a whole or partial nucleus can provide effective protection for the PC for hypermature cataract during phacoemulsification.
文摘The study was to report a new two-point scleralfixation technique for foldable intraocular lenses with four haptics.Lenses were slid into the anterior chamber from a 2.8 mm corneal incision and fixed under two sclera flaps at two opposite points.The postoperative best-corrected visual acuities(BCVAs) of all patients were significantly better than their preoperative BCVA.The results demonstrate that two-point,scleral fixations of foldable,intraocular lenses might be practicable and effective.
文摘At present, the incidence of infectious endophthalmitis after cataract surgery has been significantly reduced, but it is still a serious complication. Removal or not of the intraocular lens(IOL) during vitrectomy in cases with a moderate or severe inflammation is controversial. In order to call upon more discussion, we publish the article entitled “Timely vitrectomy without intraocular lens removal for acute endophthalmitis after cataract surgery” written by Guo et al in this issue. With recent advanced vitrectomy techniques, and critical measures for management of risk factors related to occurrence of infection, IOL remaining during timely vitrectomy for acute endophthalmitis can possibly be safe and effective in selected cases.
文摘AIM: To assess the safety, efficacy and predictability of the AcrySof phakic angle-supported intraocular lens (IOL) (Alcon Inc., U.S.A.) for correction of high-to-extremely high myopia in adults. METHODS: In this prospective study performed in Tianjin Medical University Eye Center & College of Optometry, Tianjin, China, 25 eyes of 13 patients were implanted with AcrySof phakic angle-supported IOLs and followed for 1 year postoperatively. Preoperative manifest refractive sphere was (-12.08 +/- 2.44) diopters (D) and cylinder was (-1.35 +/- 0.62)D. Visual acuity, predictability and stability of manifest refraction spherical equivalent (MRSE), adverse events, and endothelial cell density were analyzed during 1-year of follow-up. RESULTS: After 1 year of follow-up, no eyes lost 1 line (best spectacle-corrected visual acuity)BSCVA; an uncorrected visual acuity (UCVA) of 20/20 or better was achieved in 60% of eyes; 100% had an UCVA of 20/40 or better; a BSCVA of 20/30 or better was achieved by 100% of eyes; 84% had a BSCVA of 20/20 or better. The overall mean percentage change in endothelial cell density 1 year after surgery was (-0.27 +/- 3.60)%. Two eyes (8%) had increased intraocular pressure (IOP) on the day of surgery. No pupil ovalization, pupillary block, or retinal detachment events were observed. CONCLUSION: After 1 year of follow-up, the implantation of AcrySof phakic angle-supported IOL is proved to be safe, effective and predictable with minimal complications in patients with high-to-extremely high myopia. Due to the limitation of visiting time, long-term of clinical investigation is necessary to verify the safety and efficacy of this IOL.
基金Supported by the Science and Technology Planof Guangdong Province,Guangzhou,China(No.2006B36006005)
文摘AIM:To assess patients’ visual performance with glistenings in one piece soft hydrophobic acrylic intraocular lenses(IOLs)(Alcon)2y postoperatively.METHODS:This cross section trial included 120 eyes with one piece IOL at 2y postoperatively.Glistening was classified in 4 groups,ranging from 0(none)to 3(most evident)according to their severity in IOLs optics observed under a slit lamp.All eyes underwent a uncorrected and best-corrected visual acuity evaluation(UCVA and BCVA,LogMAR scale),a complete clinical examination,a contrast sensitivity(CS)evaluation by F.A.C.T chart,and a visual field test by Humphrey Field AnalyzerⅡ(HFA).One-way ANOVA was used for quantitative data,while Pearsonχ2test was used for qualitative data to analyze the visual function of 4glistening groups.RESULTS:Totally 120 eyes were enrolled with 30 eyes in each glistening group.There was no statistical correlation between glistening grades and patients’age,IOLs power,postoperative UCVA and BCVA(P】0.05).Quantificationally,CS values among each group were not statistically different.However,qualitative analysis showed there were more eyes in grade 3 group than in grade 0 group having abnormally declined CS at high spatial frequency(10%vs 36.7%at 18 cpd,P=0.029;6.7%vs 26.7%at 12 cpd,P=0.013).Mean deviation(MD)of the visual field test was-2.14±2.31,-1.97±2.23,-3.02±3.17,-4.12±3.38 in group 0 to 3 respectively.There was a significant decrease in the most serious glistenings group(P=0.018).CONCLUSION:Glistenings may potentially have an impact on contrast sensitivity at high spatial frequency and MD in visual field test.
基金Supported partly by the General Natural Science Projects,Department of Education,Zhejiang Province,China(No.Y201636718)
文摘Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patient with extrahigh myopia from implantable collamer lens (ICL) to trifocal intraocular lens (IOL) implantation.
文摘AIM: To assess the binocular visual function in bilateral cataract patients with unilateral astigmatism after combined implantations of Toric with multifocal intraocular lens (IOL), and to compare with that of Toric and monofocal IOL implantation.METHODS: All the 30 patients with unilateral astigmatism suffered bilateral cataract were randomly divided into two groups: Toric plus multifocal IOL group and Toric plus monofocal IOL group. Uncorrected and corrected visual acuity at distance (5.0 m), intermediate distance (0.6 m), and near (0.33 m), contrast sensitivity, and stereopsis were assessed 6mo after surgery. Patients were also surveyed for visual disturbances and spectacle dependence.RESULTS: Binocular uncorrected visual acuity (LogMAR) of Toric/multifocal IOL eyes at distance, intermediate, near were 0.05±0.05, 0.24±0.10, and 0.14±0.06 respectively. The values of Toric plus monofocal IOL eyes were 0.06±0.07, 0.26±0.08, and 0.37±0.10 respectively. These values did not indicate significant differences between two groups with exception of near visual acuity. In the photopic condition (with or without glare), the contrast sensitivity of multifocal IOL eyes was significant lower than the monofocal IOL eyes in 18 cpd. In the mesopic condition, the contrast sensitivity of multifocal group was significant lower than monofocal group in 12 cpd, and in mesopic glare condition, this significant difference was found both in 6 cpd and 12 cpd. The stereopsis of Toric/multifocal IOL eyes decreased slightly (100±80 seconds of arc, t=2.222, P=0.136). Mean near vision for patient satisfaction was statistically significantly higher in Toric/multifocal IOL group patients versus than that in Toric/monofocal IOL group (80% vs 25.5%, P=0.000). Visual disturbance was not noticed in either group.CONCLUSION: Although the combination of Toric and multifocal IOL implantation results in compromising stereoacuity, it can still provide patients with high levels of spectacle freedom and good overall binocular visual acuity.