期刊文献+
共找到8,866篇文章
< 1 2 250 >
每页显示 20 50 100
Effectivity and safety of trifocal intraocular lenses and capsular tension rings implantation for cataract patients with axial high myopia
1
作者 Shan Hua Qiu-Xia Xie +1 位作者 Hu Wang Jing-Xiang Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期499-508,共10页
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria... ●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications. 展开更多
关键词 trifocal intraocular lenses capsular tension ring axial high myopia CATARACT visual quality
下载PDF
Early changes in corneal densitometry after FS-LASIK combined with accelerated corneal cross-linking for correction of high myopia
2
作者 Qing-Bao Wang Hong-Sheng Bi +3 位作者 Xiao-Fan Wang Hua Fan Li Li Peng Ji 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1307-1312,共6页
AIM:To observe the effects of femtosecond laserassisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking(FS-LASIK Xtra)on corneal densitometry after correcting for high myopia.METHO... AIM:To observe the effects of femtosecond laserassisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking(FS-LASIK Xtra)on corneal densitometry after correcting for high myopia.METHODS:In this prospectively study,130 patients underwent FS-LASIK or FS-LASIK Xtra for high myopia.Their right eyes were selected for inclusion in the study,of which 65 cases of 65 eyes in the FS-LASIK group,65 patients with 65 eyes in the FS-LASIK Xtra group.Patients were evaluated for corneal densitometry at 1,3,and 6mo postoperatively using Pentacam Scheimpflug imaging.RESULTS:Preoperative differences in corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups in different ranges were not statistically significant(P>0.05).Layer-by-layer analysis revealed statistically significant differences in the anterior(120μm),central,and total layer corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups at 1 and 3mo postoperatively(all P<0.05),the FS-LASIK Xtra group is higher than that of the FS-LASIK group.Analysis of different diameter ranges showed statistically significant differences between the FS-LASIK group and the FS-LASIK Xtra group at 1mo postoperatively in the ranges of 0–2,2–6,and 6–10 mm(both P<0.05);At 3mo postoperatively,the FS-LASIK Xtra group is higher than that of the FS-LASIK group in the ranges of 0–2 and 2–6 mm(P<0.05).At 6mo postoperatively,there were no statistically significant differences in corneal densitometry between the FS-LASIK group and the FS-LASIK Xtra group in different diameter ranges(all P>0.05).CONCLUSION:There is an increase in internal corneal densitometry during the early postoperative period after FS-LASIK Xtra for correction of high myopia.However,the densitometry values decreased to the level of conventional FS-LASIK at 6mo after surgery,with the most significant changes observed in the superficial central zone. 展开更多
关键词 femtosecond laser accelerated corneal cross-linking corneal densitometry high myopia femtosecond laser in situ keratomileusis
下载PDF
Clinical Effect Analysis of Posterior Chamber Intraocular Lens Implantation for Correcting High Myopia and Astigmatism
3
作者 Bo Xia Dan Dan Zhao 《Journal of Clinical and Nursing Research》 2024年第8期99-104,共6页
Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the ca... Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety. 展开更多
关键词 Posterior chamber intraocular lens implantation in phakic eyes high myopia ASTIGMATISM Corrective effect
下载PDF
Time trends in myopia and high myopia prevalence in young university adults in China 被引量:2
4
作者 Hong-Mei Zhang Bing-Qin Li +2 位作者 Yun Zhu Sheng-Xin Liu Rui-Hua Wei 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第10期1676-1681,共6页
AIM:To investigate time trends in myopia and high myopia prevalence over 6y among young university adults in China.METHODS:This is a 6-year series cross-sectional study from 2016 to 2021.Totally 4910 freshmen were enr... AIM:To investigate time trends in myopia and high myopia prevalence over 6y among young university adults in China.METHODS:This is a 6-year series cross-sectional study from 2016 to 2021.Totally 4910 freshmen were enrolled and completed a questionnaire concerning age,gender,and disease history.Students with eye diseases were excluded after a detailed eye examination.The refractive status was measured by non-cycloplegic objective refraction and ocular parameters were measured by Lenstar 900.The examination followed the same protocol each year.Trends over time in myopia and high myopia prevalence,as well as ocular biometry parameters,were analyzed.RESULTS:From 2016 to 2021,the axial length(AL)and corneal radius(CR)increased significantly(P=0.002 for AL;P=0.04 for CR).However,the spherical equivalent(SE)and the ratio of axial length to the corneal radius(AL/CR)did not change significantly(P=0.59 for SE;P=0.24 for AL/CR).The frequency of AL≥26.0 mm increased from 26.6%in 2016 to 29.3%in 2021(P=0.05 for trend).The prevalence of myopia and high myopia did not change significantly in our study(P≥0.18).Compared to a similar cross-sectional study conducted 10 years ago,the prevalence of myopia decreased significantly(94.9%vs 91.8%,P<0.001).Whereas the prevalence of high myopia increased largely(18.12%vs 27.6%,P<0.001).CONCLUSION:The prevalence of high myopia increases in young university adults during 10y period.Myopia control should begin earlier in childhood.However,these interventions are still needed for high myopia even in young adulthood. 展开更多
关键词 myopia high myopia PREVALENCE axial length time trend
下载PDF
Effects of endogenous dopamine induced by low concentration atropine eye drops on choroidal neovascularization in high myopia mice 被引量:2
5
作者 Yan-Yan Ji Shi-Xi Zhang +1 位作者 Ye Kang Song Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第7期1034-1040,共7页
AIM:To evaluate effects of endogenous dopamine induced by low concentration atropine eye drops on choroidal neovascularization(CNV)in high myopia mice.METHODS:The C57BL/6J mice were deprived of the right eye for 4wk,a... AIM:To evaluate effects of endogenous dopamine induced by low concentration atropine eye drops on choroidal neovascularization(CNV)in high myopia mice.METHODS:The C57BL/6J mice were deprived of the right eye for 4wk,and the high myopia was diagnosed by optometry,the diopter was less than-6.00 D,and CNV was induced by 532 nm laser.The changes of dopamine D1 receptor(DRD1),dopamine D2 receptor(DRD2),and vascular endothelial growth factor A(VEGFA)were detected by Western blot technology at 0.5,1,2h,and 7d after 0.01%,0.05%,and 0.1%atropine eye drops,respectively,the area of CNV was measured.RESULTS:Significant increases were observed on the expression of DRD2 in mouse high myopia model at 0.5,1,2h,7d with 0.05%and 0.1%atropine eye drops(P<0.05).Significant decreases were observed on the expression of DRD1 and VEGFA in mouse high myopia model at 0.5,1,2h,7d with 0.05%and 0.1%atropine eye drops(P<0.05).The area of CNV induced by laser in the drug-treated group was significantly smaller than that in the control group,and the higher the concentration,the more significant the inhibitory effect(P<0.05).CONCLUSION:The 0.01%,0.05%,0.1%atropine eye drops can decrease the level of VEGFA and inhibit high myopia CNV indirectly by up-regulating the level of DRD2 and down-regulating the level of DRD1,and the effect of 0.05%and 0.1%atropine eye drops is more significant. 展开更多
关键词 high myopia choroidal neovascularization low concentration atropine eye drops dopamine D1 receptor dopamine D2 receptor
下载PDF
Changes of optic nerve head microcirculation in high myopia 被引量:1
6
作者 Wen-Quan Tang Yu-Lin Luo +1 位作者 Xi-Lang Wang Xuan-Chu Duan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第1期102-107,共6页
AIM:To analyze the correlation of age,spherical equivalent(SE),and axial length(AL)with the microcirculation of optic nerve head(ONH)in high myopia(HM).METHODS:In this cross-sectional clinical study,164 right eyes wer... AIM:To analyze the correlation of age,spherical equivalent(SE),and axial length(AL)with the microcirculation of optic nerve head(ONH)in high myopia(HM).METHODS:In this cross-sectional clinical study,164 right eyes were included.Optical coherence tomography angiography(OCTA)was used to detect ONH vessel density.Eyes were classified based on age,SE,and AL.Groups of Age1,Age2,and Age3 were denoted for age classification(Age1<20y,20y≤Age2<30y,Age3≥30y);Groups SE1,SE2,and SE3 for the SE classification(-9≤SE1<-6 D,-12≤SE2<-9 D,SE3<-12 D);Groups AL1,AL2,AL3,and AL4 for the AL classification(AL1<26 mm,26≤AL2<27 mm,27≤AL3<28 mm,AL4≥28 mm).RESULTS:No significant difference was observed in vessel density among the Age1,Age2,and Age3 groups(all P>0.05)and the SE1,SE2,and SE3 groups(all P>0.05).No significant difference was observed in the intrapapillary vascular density(IVD)among AL1,AL2,AL3,and AL4 groups(P>0.05).However,a significant decrease was found in the peripapillary vascular density(PVD)in the AL1,AL2,AL3,and AL4 groups(F=3.605,P=0.015),especially in the inferotemporal(IT;F=6.25,P<0.001),temporoinferior(TI;F=2.865,P=0.038),and temporosuperior(TS;F=6.812,P<0.001)sectors.The IVD was correlated with age(r=-0.190,P<0.05)but not with SE or AL(P>0.05).The PVD was correlated with AL(r=-0.236,P<0.01)but not with age or SE(P>0.05).CONCLUSION:With the increase of AL,the IVD remains stable while the PVD decreases,especially in the three directions of temporal(IT,TI,and TS).The main cause of microcirculation reduction may be related to AL elongation rather than an increase in age or SE. 展开更多
关键词 high myopia optic nerve head optical coherence tomography angiography vascular density axial length
下载PDF
Value of optical coherence tomography measurement of macular thickness and optic disc parameters for glaucoma screening in patients with high myopia
7
作者 Hua Mu Rui-Shu Li +1 位作者 Zhen Yin Zhuo-Lei Feng 《World Journal of Clinical Cases》 SCIE 2023年第14期3187-3194,共8页
BACKGROUND The basic method of glaucoma diagnosis is visual field examination,however,in patients with high myopia,the diagnosis of glaucoma is difficult.AIM To explore the value of optical coherence tomography(OCT)fo... BACKGROUND The basic method of glaucoma diagnosis is visual field examination,however,in patients with high myopia,the diagnosis of glaucoma is difficult.AIM To explore the value of optical coherence tomography(OCT)for measuring optic disc parameters and macular thickness as a screening tool for glaucoma in patients with high myopia.METHODS Visual values(contrast sensitivity,color vision,and best-corrected visual acuity)in three groups,patients with high myopia in Group A,patients with high myopia and glaucoma in Group B,and patients with high myopia suspicious for glaucoma in Group C,were compared.Optic disc parameters,retinal nerve fiber layer(RNFL)thickness,and ganglion cell layer(GCC)thickness were measured using OCT technology and used to compare the peri-optic disc vascular density of the patients and generate receiver operator characteristic(ROC)test performance curves of the RNFL and GCC for high myopia and glaucoma.RESULTS Of a total of 98 patients admitted to our hospital from May 2018 to March 2022,totaling 196 eyes in the study,30 patients with 60 eyes were included in Group A,33 patients with 66 eyes were included in Group B,and 35 patients with 70 eyes were included in Group C.Data were processed for Groups A and B to analyze the efficacy of RNFL and GCC measures in distinguishing high myopia from high myopia with glaucoma.The area under the ROC curve was greater than 0.7,indicating an acceptable diagnostic value.CONCLUSION The value of OCT measurement of RNFL and GCC thickness in diagnosing glaucoma in patients with high myopia and suspected glaucoma is worthy of development for clinical use. 展开更多
关键词 high myopia suspected glaucoma Optical coherence tomography Retinal nerve fiber layer thickness Ganglion cell layer thickness Diagnostic efficacy
下载PDF
Evolution and trends of high myopia research from 2002 to 2021: a scientometric analysis
8
作者 Yuan Tan Weining Zhu +7 位作者 Yingshi Zou Bowen Zhang Yinglin Yu Wei Li Chaoqun Xu Leyi Hu Guangming Jin Zhenzhen Liu 《Annals of Eye Science》 2023年第4期22-35,共14页
Background:Research on high myopia has gradually formed a complex network of knowledge,but a panorama of evolutionary trends is lacking.By conducting a scientometric analysis,we can gain a deeper understanding of the ... Background:Research on high myopia has gradually formed a complex network of knowledge,but a panorama of evolutionary trends is lacking.By conducting a scientometric analysis,we can gain a deeper understanding of the development and evolution of this field.Methods:The global literature on high myopia published from 2002 to 2021 was extracted from the Science Citation Index Expanded in the Web of Science Core Collection.Microsoft Excel,VOSviewer,and CiteSpace were used to analyse and visualize the bibliometric data.Publication-related information,including countries,journals,authors,citations,subject categories,and its’time trends,was analysed.Results:A total of 4,226 included publications showed an annually increasing trend during the past 20 years.The high myopia research hotspots were refractive error correction,epidemiology,ocular biometry,drug and laser treatment of myopic fundus lesions,and surgical treatment of myopic fundus lesions.Cocitation analysis showed that high myopia genetics and myopic fundus lesion research were the research frontiers.A total of 116 disciplines were involved in high myopia research.Ophthalmology(n=3,338)was the most dominant subject category.Engineering(betweenness centrality=0.65)was the discipline with the most obvious bridge role.Science&technology—other topics(burst years:2015–2021;strength=14.88)had the greatest strength as of 2021,which was the hottest subject category.Conclusions:High myopia genetics and myopic fundus lesion research showed a potential for breakthroughs.Medical-engineering cross-innovation is a cutting-edge technology trend. 展开更多
关键词 high myopia theme change EVOLUTION research hotspot
下载PDF
Trends in research related to high myopia from 2010 to 2019:a bibliometric and knowledge mapping analysis 被引量:5
9
作者 Xiao-Dan Zhang Chun-Xia Wang +3 位作者 Hong-Hu Jiang Shuo—Lan Jing Jiang-Yue Zhao Zi-Yan Yu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第4期589-599,共11页
AIM:To evaluate the global trends in and explore hotspots of high myopia(HM)research.METHODS:This bibliometric analysis was used to reveal the publication trends in HM research field based on the Web of Science Core C... AIM:To evaluate the global trends in and explore hotspots of high myopia(HM)research.METHODS:This bibliometric analysis was used to reveal the publication trends in HM research field based on the Web of Science Core Collection(WoSCC).VOSviewer version 1.6.13 software was used to analyze the data and construct a knowledge map including the yearly publication number,journals,countries,international collaborations,authors,research hotspots,and intellectual base in HM.RESULTS:The search engine found 3544 peer-reviewed publications on HM between 2010 and 2019,and the yearly research output substantially elevated over the past decade.China is the top publishing country,and Sun Yatsen University was the most active academic institution.Jonas JB is the top publishing scientist,and Investigative Ophthalmology and Visual Science(IOVS)was the most productive journal.The highest cited references mainly focused on epidemiology and management.The keywords formed 6 clusters:1)refractive surgery;2)etiology and clinical characteristics;3)the mechanism of eye growth;4)management for myopic maculopathy;5)vitrectomy surgical treatment;6)myopia-associated glaucoma-like optic neuropathy.CONCLUSION:The evaluation of development trends based on the data extracted from WoSCC can provide valuable information and guidance for ophthalmologists and public health researchers to improve management procedures in HM field. 展开更多
关键词 high myopia pathological myopia bibliometric analysis VOSviewer
下载PDF
Five‑year outcomes of EVO implantable collamer lens implantation for the correction of high myopia and super high myopia 被引量:6
10
作者 Xun Chen Xuanqi Wang +5 位作者 Yilin Xu Mingrui Cheng Tian Han LingLing Niu Xiaoying Wang Xingtao Zhou 《Eye and Vision》 SCIE CSCD 2021年第1期404-411,共8页
Background:To evaluate the long-term safety,efficacy,predictability,and stability of implantable collamer lens with a central hole(EVO ICL)implantation for correcting high myopia(HM)and super high myopia(SHM).Methods:... Background:To evaluate the long-term safety,efficacy,predictability,and stability of implantable collamer lens with a central hole(EVO ICL)implantation for correcting high myopia(HM)and super high myopia(SHM).Methods:This prospective study evaluated 83 eyes of 46 patients who were divided into groups based on their spherical equivalent refractive error(SE):HM group(−12 D≤SE<−6 D)and SHM group(SE<−12 D).They were followed up for 5 years after ICL implantation;assessments of uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),manifest refractive error,axial length,intraocular pressure,corneal endothelial cell density,and vault were conducted,and a questionnaire was administered.ResuIts:At 5 years postoperatively,the safety indices of the HM and SHM groups were 1.03±0.10 and 1.32±0.39,and the efficacy indices were 0.83±0.25 and 0.86±0.32,respectively.In the HM group,60.47%and 79.07%of the eyes were within±0.50 D and±1.00 D of the attempted correction,while it was achieved for 22.50%and 47.50%of the eyes in the SHM group,respectively.The SE of the HM group decreased from−9.72±1.41 D preoperatively to 0.04±0.39 D 1 month postoperatively and−0.67±0.57 D 5 years postoperatively,while in the SHM group,it decreased from−15.78±3.06 D preoperatively to−0.69±0.97 D 1 month postoperatively and−1.74±1.19 D 5 years postoperatively.Conclusion:EVO ICL implantation is safe,effective,and predictable for correcting HM and SHM.CDVA improved more after surgery for SHM,but the growth of axial length still needs attention. 展开更多
关键词 Posterior chamber phakic intraocular lens implantation high myopia super high myopia EVO ICL
原文传递
Progression of myopia among undergraduate students in central China
11
作者 Ting Fu Yan Xiang Jun-Ming Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第2期274-279,共6页
AIM:To investigate the progression of myopia and risk factors among university students in central China.METHODS:A total of 7359 first-year undergraduate students at Huazhong University of Science and Technology in ce... AIM:To investigate the progression of myopia and risk factors among university students in central China.METHODS:A total of 7359 first-year undergraduate students at Huazhong University of Science and Technology in central China were recruited to the study and invited to a centralized clinic for medical examination,including optometry,and re-examined after one year.Correlation analyses were performed to assess the associations between one-year myopia progression and various parameters.RESULTS:The spherical equivalent refraction for the overall population was-3.14±2.28 D at baseline.The rate of myopia progression over 0.50 D after one year was 41.9%,and the 1-year progression of myopia was-0.47±0.58 D.There was no difference of mean 1-year myopia progression between male and female or difference among age group.The myopia progression of original myopia was severer than progression of new-onset myopia.There was also difference of mean myopia progression among different degrees of myopia at baseline.The under corrected eyes had a higher percentage of myopia progression than well corrected eyes(χ^(2)=7.90,P<0.01).There was no correlation between myopia progression and height,weight,body mass index,hemoglobin(Spearman correlation,ρ=-0.078,-0.152,-0.170,-0.096,respectively,all P>0.05).CONCLUSION:Myopes still progress in undergraduate students,especially in high myopes. 展开更多
关键词 myopia progression high myopia PREVALENCE undergraduate students
下载PDF
Long-term vision-threatening complications of phakic intraocular lens implantation for high myopia 被引量:14
12
作者 Isil Bahar Sayman Muslubas Baran Kandemir +2 位作者 Ayse Yesim Aydin Oral Suleyman Kugu Metin Dastan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期376-380,共5页
AIMTo report the long-term vision-threatening complications in patients who underwent phakic intraocular lens (pIOLs) implantation for high myopia.
关键词 phakic intraocular lens high myopia COMPLICATIONS corneal decompensation rhegmatogenous retinal detachment
下载PDF
Comparison of OA-2000 and IOL Master 500 using in cataract patients with high myopia 被引量:11
13
作者 Ya-Li Du Geng Wang +5 位作者 Hui-Chun Huang Li-Yu Lin Chuang Jin Li-Fang Liu Xiu-Ru Liu Ming-Zhi Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第5期844-847,共4页
This study was designed to compare optical biometry measurements and predicted refraction in cataract patients with high myopia [axial length(AL) ≥26 mm] using OA-2000 and IOL Master 500. Ocular biometry measurements... This study was designed to compare optical biometry measurements and predicted refraction in cataract patients with high myopia [axial length(AL) ≥26 mm] using OA-2000 and IOL Master 500. Ocular biometry measurements were performed using both biometers before surgery. Uneventful cataract surgery was performed in all patients. Postoperative manifest refraction was obtained 3 wk after surgery or later. A total of 67 eyes were examined. The AL, keratometry(K), and anterior chamber depth(ACD) of the two biometers showed excellent agreement. Predicted errors were similar and a strong positive correlation was observed(r=0.909). Out of 21 eyes(31.34%) with unsuccessful AL readings using the IOL Master 500, 20 eyes of them could be measured using OA-2000. Therefore, the biometric parameters measured by the two biometers showed good agreement. However, OA-2000 had a lower AL measurement failure rate. 展开更多
关键词 OA-2000 IOL Master 500 BIOMETRY measurement IOL power calculation high myopia CATARACT
下载PDF
Comparison axial length measurements from three biometric instruments in high myopia 被引量:6
14
作者 Xiao-Gang Wang Jing Dong +2 位作者 Yu-Lan Pu Hui-Jun Liu Qiang Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第6期876-880,共5页
AIM: To compare the axial lengths (ALs) measured with Lenstar, IOLMaster and A-scan contact ultrasound (Ultrasound) in normal and high myopia (HM). METHODS: Eighty-four normal eyes and 49 HM eyes were include... AIM: To compare the axial lengths (ALs) measured with Lenstar, IOLMaster and A-scan contact ultrasound (Ultrasound) in normal and high myopia (HM). METHODS: Eighty-four normal eyes and 49 HM eyes were included. Three consecutive measurements were performed on each eye in the following order: Lenstar, IOLMaster, and Ultrasound. The repeatabilities of the AL measurements for each instrument were assessed by calculating the pooled coefficients of variation (CVs) of 18 eyes in each group. Comparisons between the HM and normal groups were made with independent sample t-tests. The inter-device agreements were evaluated with Bland-Altman analyses and paired two-tailed t-tests. RESULTS: For normal group, the CVs of the AL measurements taken with the Lenstar, IOLMaster and Ultrasound were 0.001%, 0.01% and 0.14%, respectively. The corresponding CVs for the HM group were 0.005%, 0.02% and 0.15%, respectively. There was significant difference between the Lenstar and the IOLMaster in normal group (P=0.031) but not in HM group (n=0.100). In the two groups, the Lenstar and the IOLMaster produced higher values than did the Ultrasound (all P〈 0.001). All three instruments exhibited good agreement in terms of AL values. For the intraocular lens (IOL) power calculation using SRK II formula, the Lenstar and the IOLMaster showed 0.5 D higher than Ultrasound in both groups (all P〈0.001). No significant difference existed between the Lenstar and the IOLMaster for the IOL power calculation in both normal (n=0.474) and HM group (P= 0.103). CONCLUSION: The three devices exhibited excellent intra-visit repeatabilities in the AL measurements. The AL and IOL power difference between partial coherence interferometry and ultrasound instruments should be noticed. 展开更多
关键词 axial length BIOMETRY REPEATABILITY intraocular lens high myopia
下载PDF
Diagnostic ability of ganglion cell complex thickness to detect glaucoma in high myopia eyes by Fourier domain optical coherence tomography 被引量:9
15
作者 Wei-Wei Wang Huai-Zhou Wang +4 位作者 Jian-Rong Liu Xi-Fang Zhang Meng Li Yan-Jiao Huo Xin-Guang Yang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第5期791-796,共6页
AIM:To evaluate the ability of macular ganglion cell complex(GCC) thickness using Fourier domain optical coherence tomography(FD-OCT) to detect glaucoma in highly myopic eyes.METHODS:Cross-sectional study.A tota... AIM:To evaluate the ability of macular ganglion cell complex(GCC) thickness using Fourier domain optical coherence tomography(FD-OCT) to detect glaucoma in highly myopic eyes.METHODS:Cross-sectional study.A total of 114 participants,consecutively were enrolled.Macular GCC thickness and peripapillary retinal nerve fiber layer(RNFL) thickness were obtained with RTVue FD-OCT.Receiver operating characteristics curves were constructed for each measurement parameter,and areas under the curves(AUCs) were compared.RESULTS:Both the average GCC and average RNFL thickness showed negative correlations with axial length(rGCC=-0.404,P=0.001;rRNFL=-0.561,P〈0.001).The largest AUCs from GCC,and RNFL parameters were 0.968 [global loss volume(GLV)],and 0.855(average RNFL),respectively.GLV was significantly better for detecting high myopic glaucoma than average RNFL(P〈0.001).CONCLUSION:Macular GCC thickness has higher diagnostic power than peripapillary RNFL thickness to discriminate glaucoma patients from non-glaucoma subjects in high myopia. 展开更多
关键词 optical coherence tomography GLAUCOMA high myopia ganglion cell complex
下载PDF
The association of lumican polymorphisms and high myopia in a Southern Chinese population 被引量:6
16
作者 Gui-Fang Wang Qing-Shan Ji +3 位作者 Bing Qi Guo-Cheng Yu Lian Liu Jing-Xiang Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第10期1516-1520,共5页
AIM:To investigate the correlation between lumican(LUM)gene and high myopia in a Southern Chinese population.METHODS:The study comprised of 95 high myopia patients with a spherical equivalent≤-6.5 diopters(D).T... AIM:To investigate the correlation between lumican(LUM)gene and high myopia in a Southern Chinese population.METHODS:The study comprised of 95 high myopia patients with a spherical equivalent≤-6.5 diopters(D).The control group recruited 95 individuals with a spherical equivalent ranging from-0.5 D to+0.5 D.Direct sequencing was used to detect the single nucleotide polymorphisms(SNPs)of LUM gene in coding region.Genotype distributions were tested for Hardy-Weinberg disequilibrium.Genotypic and allelic frequencies were analyzed through Chi-square test or Fisher’s exact test.RESULTS:We identified 3 SNPs of the LUM gene:LUM c.32(rs577456426),LUM c.507(rs17853500)and LUM c.849(rs181915277).Among the three SNPs,the genotype and allele frequencies of rs17853500 showed a significant difference between patients and control subjects(P〈0.05).However,there were no significant differences in rs181915277and rs577456426 between the two groups(P〉0.05).CONCLUSION:LUM c.507 polymorphism may be a risk factor for the pathogenesis of high myopia in the Southern Chinese population. 展开更多
关键词 LUMICAN sclem high myopia single nucleotidepolymorphisms
下载PDF
Association between lumican gene-1554 T/C polymorphism and high myopia in Asian population:a meta-analysis 被引量:5
17
作者 Xuan Liao Xu-Bo Yang +2 位作者 Meng Liao Chang-Jun Lan Long-Qian Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期696-701,共6页
AIMTo investigate the association between lumican gene -1554 T/C polymorphism and high myopia susceptibility.
关键词 LUMICAN high myopia gene polymorphism META-ANALYSIS
下载PDF
High myopia as a risk factor in primary open angle glaucoma 被引量:12
18
作者 Sheng-Ju Chen Peng Lu +1 位作者 Wen-Fang Zhang Jian-Hua Lu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第6期750-753,共4页
Glaucoma, one of the leading causes of irreversible blindness in the adult population worldwide, is a progressive optic neuropathy. Primary open angle glaucoma (POAG) is the most commonly reported type of glaucoma in ... Glaucoma, one of the leading causes of irreversible blindness in the adult population worldwide, is a progressive optic neuropathy. Primary open angle glaucoma (POAG) is the most commonly reported type of glaucoma in population based prevalence studies worldwide. Elevated intraocular pressure is a well-known major risk factor for POAG. In addition, there is growing evidence that other risk factors like age, gender, race, refractive error, heredity and systemic factors may play a role in glaucoma pathogenesis. Many studies found that high myopia has been associated with POAG, however, direct and convincing evidences are still lacking. The aim of this review is to summarize the evidences implicating high myopia as a risk factor in the pathogenesis of POAG. 展开更多
关键词 high myopia primary open angle glaucoma risk factor
下载PDF
Genetic association of COL1A1 polymorphisms with high myopia in Asian population: a Meta-analysis 被引量:5
19
作者 Bo Gong Chao Qu +6 位作者 Xiao-Fang Huang Zi-Meng Ye Ding-Ding Zhang Yi Shi Rong Chen Yu-Ping Liu Ping Shuai 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第8期1187-1193,共7页
AIM: To comprehensively evaluate the potential association of COL1A1 polymorphisms with high myopia by a systematic review and Meta-analysis. METHODS: All association studies on COL1A1 and high myopia reported up to J... AIM: To comprehensively evaluate the potential association of COL1A1 polymorphisms with high myopia by a systematic review and Meta-analysis. METHODS: All association studies on COL1A1 and high myopia reported up to June 10, 2014 in PubMed, Embase, Web of Science, and the Chinese Biomedical Database were retrieved. Odds ratios (ORs) and 95% confidence intervals (95% CIs) were analyzed for single-nucleotide polymorphisms (SNPs) using fixed- and random - effects models according to between-study heterogeneity. Publication bias analyses were conducted by Eggers test. RESULTS: A total of four studies from reported papers were included in this analysis. The Meta-analyses for COL1A1 rs2075555, composed of 2304 high myopia patients and 2272 controls, failed to detect any significant association with high myopia. A total of 971 cases and 649 controls were tested for COL1A1 rs2269336. The association of COL1A1 rs2269336 with high myopia was observed in recessive model (CC vs CG+GG, P = 0.03) and in heterozygous model (CG vsGG, P = 0.04), but not in other models. CONCLUSION: This Meta-analysis shows that COL fill rs2269336 (CC vs CG +GG) affects individual susceptibility to high myopia, whereas there is no association detected between SNPs rs2075555 and high myopia. Given the limited sample size, further investigations including more ethnic groups are required to validate the association. 展开更多
关键词 COL1A1 high myopia ASSOCIATION META-ANALYSIS
下载PDF
Comparison of correcting myopia and astigmatism with SMILE or FS-LASIK and postoperative higher-order aberrations 被引量:15
20
作者 Peng-Fei Zhao Ya-Bin Flu +3 位作者 Yue Wang Cai-Yun Fu Jing Zhang Chang-Bin Zhai 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第4期523-528,共6页
AIM:To compare the effect of myopia and astigmatism correction and postoperative change in higher-order aberration as results of receiving small-incision lenticule extraction(SMILE)and femtosecond laser-assisted in si... AIM:To compare the effect of myopia and astigmatism correction and postoperative change in higher-order aberration as results of receiving small-incision lenticule extraction(SMILE)and femtosecond laser-assisted in situ keratomileusis(FS-LASIK).METHODS:A prospective and non-randomized controlled study was conducted.The subjects are divided into two groups according to different operations received:229 eyes of 116 patients in the SMILE group and 168 eyes of 86 patients in the FS-LASIK group.All subjects were followed up for 3 mo by monitoring their uncorrected visual acuity(UCVA),best-corrected visual acuity(BCVA),spherical equivalent,higher-order aberrations,and the preoperative and postoperative complications.RESULTS:At 1 wk,1,and 3 mo post-surgery,224 eyes(97.8%),227 eyes(99.1%)and 229 eyes(100%)had UCVA≥20/20 in the SMILE group,while 165 eyes(98.2%),167 eyes(99.4%)and 167 eyes(99.4%)had UCVA≥20/20 in the FS-LASIK group,respectively(χ^(2)=0.146,2.135,and 1.124;all P>0.05).BCVA reduction was not observed in both groups at 1 and 3 mo of post-surgery(χ^(2)=0.734 and 1.898,P>0.05).There was no statistically significant difference in the spherical equivalent between the two groups at 1 and 3 mo post-surgery,though the percentage of the spherical equivalent within±0.50 D at 3 mo postsurgery was 98%in the SMILE group,which was higherthan that of the FS-LASIK group(92%,χ^(2)=1.872,P>0.05).The root mean square(RMS)values of total high-order aberration,coma,and spherical aberration of the two groups increased significantly in the early postoperative period and decreased after 3 mo,but the values were still higher than the preoperative levels(P<0.05);there was no significant difference between the two groups in the RMS values of total higher-order aberrations and specific higherorder aberrations(P>0.05).The incidence of complications in the SMILE group was lower than that in the FS-LASIK group(χ^(2)=14.52,P<0.05).CONCLUSION:SMILE and FS-LASIK can effectively treat myopia,significantly improve visual acuity,and increase the total high-order aberration,spherical aberration,and coma.The incidence of complications after SMILE is relatively low. 展开更多
关键词 myopia femtosecond laser in situ keratomileusis small incision lenticule extraction high order aberrations
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部