期刊文献+
共找到32,289篇文章
< 1 2 250 >
每页显示 20 50 100
Current knowledge for the risk factors of early permanent pacemaker implantation following transcatheter aortic valve replacement and what is next for the primary prevention? 被引量:1
1
作者 Gen-Min Lin Wei-Chun Huang Chih-Lu Han 《World Journal of Cardiology》 2024年第2期54-57,共4页
In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from... In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from several renowned clinical studies and focused on the primary prevention of managing the modifiable factors,e.g.,paroxysmal atrial fibrillation before the TAVR. 展开更多
关键词 Permanent pacemaker implantation Transcatheter aortic valve replacement Interventricular conduction delay DIABETES Supraventricular arrhythmia
下载PDF
Is primary transcatheter aortic valve implantation the new normal?
2
作者 R.Anantharaman C.Sundar +1 位作者 Kamal Kant Jena K.Arun 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第4期458-461,共4页
Degenerative calcific aortic valve stenosis(AS)is the most common valvular heart disease in elderly.^[1] It is well documented that symptomatic severe AS follows a malignant course leading to cardiogenic shock(CS).
关键词 AORTIC STENOSIS implantation
下载PDF
Transcatheter aortic valve implantation versus surgery:4-year survival according to life expectancy
3
作者 Vittoria Lodo Enrico G.Italiano +4 位作者 Edoardo Zingarelli Claudio Pietropaolo Stefano Pidello Gabriella Buono Paolo Centofanti 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第9期846-854,共9页
Background In the last years,transcatheter aortic valve implantation(TAVI)indication has expanded to younger and lower risk patients.Consequently,interest in mid and long-term follow up and in the role of life expecta... Background In the last years,transcatheter aortic valve implantation(TAVI)indication has expanded to younger and lower risk patients.Consequently,interest in mid and long-term follow up and in the role of life expectancy,as a key factor for selecting the most tailored treatment,has grown.The aim of this retrospective study is to compare the 4-year survival of patients who underwent aortic valve replacement(AVR)vs.TAVI at our department.Methods From September 2017 to December 2020,673 consecutive patients with severe aortic valve stenosis were enrolled for AVR(n=283)or TAVI(n=390).Inclusion criteria was isolated severe aortic stenosis,while exclusion criteria were redo surgery,valve-in-valve procedure and the need for concomitant surgical procedures.Based on the Lee index,patients were divided into four groups according to their 4-year life expectancy.Four-year survival was assessed and reported using the Kaplan-Meier method.A multivariate regression analysis of risk factors for 4-year mortality was performed.Results Four years survival is always superior in the AVR patients(89.8%vs.75.6%,P<0.001).Surgery is associated with a higher incidence of acute kidney injury(23%vs.5.1%,P<0.001),while TAVI is related to a higher incidence of new onset left bundle branch block(0 vs.23.8%,P<0.001),pace-maker implantation(2.5%vs.11.8%,P=0,02)and mild-to-moderate paravalvular leak(0.3%vs.5.4%,P<0.001).The independent risk factors for 4-years mortality are post-procedural AKI,poor mobility and transcatheter procedure.Conclusion In our analysis,4 years survival is always superior in the AVR patients.Life expectancy is a key factor for selecting the most appropriate approach for each patient.A longer follow up is mandatory before extending TAVI indication to patients with a long-life expectancy. 展开更多
关键词 SURGERY implantation selecting
下载PDF
Nursing Care and Causative Analysis of Grade IV Capsular Contracture Following Breast Cancer Expander Implantation
4
作者 Rong Chen Nan Zhang Huiting Zhang 《Advances in Breast Cancer Research》 CAS 2024年第1期1-9,共9页
Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reason... Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reasons for the formation of capsular contracture after Stage I expander implantation and prevent its recurrence following Stage II reconstruction. Methods: In May 2020, the patient noticed an increase in the size of a breast mass. In August, she underwent AC-THP neoadjuvant chemotherapy, followed by a “right breast-conserving nipple-areolar subglandular excision + right axillary lymph node dissection + expander implantation” surgery in November 2020. Radiation therapy began in January 2021. During radiation therapy, the patient experienced severe breast hardening, distortion, tenderness, and was diagnosed with Grade IV capsular contracture. To relieve the capsular contracture, the patient underwent a “contracted capsule incision and release procedure + removal of the right breast expander + right breast implantation” surgery in July 2021. Postoperatively, measures were taken to prevent incision infection, emphasizing aseptic techniques, ensuring smooth negative pressure drainage, reducing skin flap tension, monitoring skin flap blood supply, actively preventing subcutaneous effusion and hematoma, and applying appropriate compression dressings. Results: The patient was discharged after the removal of the drainage tube. During the postoperative follow-up at 3 and 6 months, there was no recurrence of capsular contracture, and the breast appeared full, upright, and relatively soft. There were no complications such as hematoma, infection, breast implant rupture, breast sagging, or displacement. The patient had a good outcome without additional financial or surgical burdens. Conclusion: The occurrence of Grade IV capsular contracture in the patient is generally related to infection after Stage I expander implantation, improper compression dressing, excessive saline injection causing content infiltration, and radiation therapy. Therefore, it is recommended to enhance the intraoperative and postoperative prophylactic use of antibiotics after Stage I expander implantation. Intermittent saline injection after surgery, with the amount of saline gradually increasing rather than filling all at once, is advisable. This helps the breast tissue gradually adapt to expansion, reducing the risk of capsular contracture. Postoperatively, patients should be instructed to wear pressure garments and breast elastic bandages while intensifying breast monitoring during radiation therapy and increasing postoperative follow-up. 展开更多
关键词 Breast Cancer Capsular Contracture Expander implantation
下载PDF
In‑depth proteome characterization of endometrium and extraembryonic membranes during implantation in pig
5
作者 Maria A.Gil Josep M.Cambra +3 位作者 Heriberto Rodriguez‑Martinez Cristina Cuello Inmaculada Parrilla Emilio A.Martinez 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2024年第3期1027-1055,共29页
Background Proteome characterization of the porcine endometrium and extraembryonic membranes is important to understand mother-embryo cross-communication.In this study,the proteome of the endometrium and cho-rioallant... Background Proteome characterization of the porcine endometrium and extraembryonic membranes is important to understand mother-embryo cross-communication.In this study,the proteome of the endometrium and cho-rioallantoic membrane was characterized in pregnant sows(PS)during early gestation(d 18 and 24 of gestation)and in the endometrium of non-pregnant sows(NPS)during the same days using LC-MS/MS analysis.The UniProtKB database and ClueGO were used to obtain functional Gene Ontology annotations and biological and functional networks,respectively.Results Our analysis yielded 3,254 and 3,457 proteins identified in the endometrium of PS and NPS,respectively;of these,1,753 being common while 1,501 and 1,704 were exclusive to PS and NPS,respectively.In addition,we iden-tified 3,968 proteins in the extraembryonic membranes of PS.Further analyses of function revealed some proteins had relevance for the immune system process and biological adhesion in endometrium while the embryonic chorion displayed abundance of proteins related to cell adhesion and cytoskeletal organization,suggesting they dominated the moment of endometrial remodeling,implantation and adhesion of the lining epithelia.Data are available via Pro-teomeXchange with identifier PXD042565.Conclusion This is the first in-depth proteomic characterization of the endometrium and extraembryonic mem-branes during weeks 3 to 4 of gestation;data that contribute to the molecular understanding of the dynamic environ-ment during this critical period,associated with the majority of pregnancy losses. 展开更多
关键词 ENDOMETRIUM Extraembryonic membranes implantation PIG PROTEOME
下载PDF
Clinical prediction of insufficient vaults after implantable collamer lens implantation
6
作者 Jun Zhu Dan Cheng +3 位作者 Xue-Ying Zhu Fen-Fen Li Ye Yang Yu-Feng Ye 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1300-1306,共7页
AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants ... AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery. 展开更多
关键词 insufficient vault implantable collamer lens ciliary body posterior chamber
下载PDF
Glaucoma drainage device implantation and cyclophotocoagulation in the management of refractory glaucoma after Descemet-stripping automated endothelial keratoplasty
7
作者 Min-Shu Wang Xue-Chuan Dong +4 位作者 Mi-Yun Zheng Xiang Fan Ge-Ge Xiao Jing Hong Ling-Ling Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期257-264,共8页
AIM:To compare the surgical outcomes of glaucoma drainage device implantation(GDI)and trans-scleral neodymium:YAG cyclophotocoagulation(CPC)in the management of refractory glaucoma after Descemetstripping automated en... AIM:To compare the surgical outcomes of glaucoma drainage device implantation(GDI)and trans-scleral neodymium:YAG cyclophotocoagulation(CPC)in the management of refractory glaucoma after Descemetstripping automated endothelial keratoplasty(DSAEK).METHODS:This retrospective study on observational case series enrolled 29 patients who underwent DSAEK and posterior anti-glaucoma surgery(15 with GDI and 14 with CPC).The main outcome measures were intraocular pressure(IOP),glaucoma surgery success rate(defined as IOP of 6–21 mm Hg without additional anti-glaucoma operation),number of glaucoma medications,endothelial graft status,and best-corrected visual acuity(BCVA).RESULTS:The mean follow-up time was 34.1 and 21.0mo for DSAEK or glaucoma surgeries,both for the GDI and CPC groups.Both groups showed significant IOP reduction after glaucoma surgery.The GDI group presented a significantly higher success rate in IOP control than the CPC group(60%vs 21.4%,P=0.03).Both procedures significantly decreased the number of glaucoma medications(P=0.03).Forty percent and 57%of cases in the GDI and the CPC group,respectively,experienced endothelial graft failure during follow-up(P=0.36).Significantly worse BCVA after surgery was observed in the CPC group but not in the GDI group.CONCLUSION:Both GDI and CPC significantly decrease IOP in eyes with glaucoma after DSAEK.GDI is preferable to CPC in refractory glaucoma cases after DSAEK,as it manifests a significantly higher success rate for IOP control,similar endothelial graft failure rate,and relatively preserves BCVA than CPC. 展开更多
关键词 glaucoma drainage device implantation CYCLOPHOTOCOAGULATION refractory glaucoma Descemetstripping automated endothelial keratoplasty
下载PDF
Embryo Transfer Strategies for Women with Recurrent Implantation Failure During the Frozen-thawed Embryo Transfer Cycles:Sequential Embryo Transfer or Double-blastocyst Transfer?
8
作者 Qiao-hang ZHAO Yu-wei SONG +8 位作者 Jian CHEN Xiang ZHOU Ji-lai XIE Qiu-ping YAO Qi-yin DONG Chun FENG Li-ming ZHOU Wei-ping FU Min JIN 《Current Medical Science》 SCIE CAS 2024年第1期212-222,共11页
Objective Both sequential embryo transfer(SeET)and double-blastocyst transfer(DBT)can serve as embryo transfer strategies for women with recurrent implantation failure(RIF).This study aims to compare the effects of Se... Objective Both sequential embryo transfer(SeET)and double-blastocyst transfer(DBT)can serve as embryo transfer strategies for women with recurrent implantation failure(RIF).This study aims to compare the effects of SeET and DBT on pregnancy outcomes.Methods Totally,261 frozen-thawed embryo transfer cycles of 243 RIF women were included in this multicenter retrospective analysis.According to different embryo quality and transfer strategies,they were divided into four groups:group A,good-quality SeET(GQ-SeET,n=38 cycles);group B,poor-quality or mixed-quality SeET(PQ/MQ-SeET,n=31 cycles);group C,good-quality DBT(GQ-DBT,n=121 cycles);and group D,poor-quality or mixed-quality DBT(PQ/MQ-DBT,n=71 cycles).The main outcome,clinical pregnancy rate,was compared,and the generalized estimating equation(GEE)model was used to correct potential confounders that might impact pregnancy outcomes.Results GQ-DBT achieved a significantly higher clinical pregnancy rate(aOR 2.588,95%CI 1.267–5.284,P=0.009)and live birth rate(aOR 3.082,95%CI 1.482–6.412,P=0.003)than PQ/MQ-DBT.Similarly,the clinical pregnancy rate was significantly higher in GQ-SeET than in PQ/MQ-SeET(aOR 4.047,95%CI 1.218–13.450,P=0.023).The pregnancy outcomes of GQ-SeET were not significantly different from those of GQ-DBT,and the same results were found between PQ/MQ-SeET and PQ/MQ-DBT.Conclusion SeET relative to DBT did not seem to improve pregnancy outcomes for RIF patients if the embryo quality was comparable between the two groups.Better clinical pregnancy outcomes could be obtained by transferring good-quality embryos,no matter whether in SeET or DBT.Embryo quality plays a more important role in pregnancy outcomes for RIF patients. 展开更多
关键词 recurrent implantation failure sequential embryo transfer frozen-thawed embryo transfer embryo transfer strategies
下载PDF
Molecular dynamics simulation study of nitrogen vacancy color centers prepared by carbon ion implantation into diamond
9
作者 Wei Zhao Zongwei Xu +1 位作者 Pengfei Wang Hanyi Chen 《Nanotechnology and Precision Engineering》 EI CAS CSCD 2024年第3期71-78,共8页
Nitrogen vacancy(NV)color centers in diamond have useful applications in quantum sensing andfluorescent marking.They can be gen-erated experimentally by ion implantation,femtosecond lasers,and chemical vapor deposition... Nitrogen vacancy(NV)color centers in diamond have useful applications in quantum sensing andfluorescent marking.They can be gen-erated experimentally by ion implantation,femtosecond lasers,and chemical vapor deposition.However,there is a lack of studies of the yield of NV color centers at the atomic scale.In the molecular dynamics simulations described in this paper,NV color centers are pre-pared by ion implantation in diamond with pre-doped nitrogen and subsequent annealing.The differences between the yields of NV color centers produced by implantation of carbon(C)and nitrogen(N)ions,respectively,are investigated.It is found that C-ion implantation gives a greater yield of NV color centers and superior location accuracy.The effects of different pre-doping concentrations(400–1500 ppm)and implantation energies(1.0–3.0 keV)on the NV color center yield are analyzed,and it is shown that a pre-doping concentra-tion of 1000 ppm with 2 keV C-ion implantation can produce a 13%yield of NV color centers after 1600 K annealing for 7.4 ns.Finally,a brief comparison of the NV color center identification methods is presented,and it is found that the error rate of an analysis utiliz-ing the identify diamond structure coordination analysis method is reduced by about 7%compared with conventional identification+methods. 展开更多
关键词 NV color center Ion implantation Molecular dynamics(MD)simulation Yield enhancement
下载PDF
Transcapsular scleral fixation of the standard capsular tension ring and in-the-bag intraocular lens implantation for severely subluxated lenses
10
作者 Hong-Zhe Li Fu-Man Yang +3 位作者 Ze-Hui Zhu Yin-Ying Zhao Ping-Jun Chang Yun-E Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第12期2321-2326,共6页
AIM:To present a technique of transcapsular scleral fixation of the standard capsular tension ring(CTR)through equatorial capsulotomy and in-the-bag intraocular lens(IOL)implantation in subluxated lenses.METHODS:This ... AIM:To present a technique of transcapsular scleral fixation of the standard capsular tension ring(CTR)through equatorial capsulotomy and in-the-bag intraocular lens(IOL)implantation in subluxated lenses.METHODS:This retrospective consecutive case series included patients with subluxated lenses by more than 180 degrees who underwent lens extraction,transcapsular scleral fixation of the standard CTR through equatorial capsulotomy,in-the-bag IOL implantation and with at least 6mo follow-up.Preoperative and postoperative best corrected visual acuity(BCVA),intraocular pressure(IOP),complications,and postoperative IOL tilt and decentration were recorded.RESULTS:Nine eyes of 7 patients with a mean followup of 11.0±3.7mo were included in this study.The BCVA was significantly improved from 0.64±0.22 logMAR preoperatively to 0.21±0.19 logMAR postoperatively(P<0.001).The IOP was within the normal range postoperatively.The mean tilt of the IOL was 4.30°±2.31°(range,1.0°to 8.9°)and the mean decentration of the IOL was 0.37±0.12 mm(range,0.14 to 0.50 mm).No visually threatened intraoperative and postoperative complications were detected during the follow-up period.CONCLUSION:This is a safe and effective surgical technique for managing patients with severely subluxated lenses.It has achieved favorable outcomes with fewer surgical manipulations and less need for advanced capsular support devices. 展开更多
关键词 lens subluxation surgical technique capsular tension ring transcapsular scleral fixation in-thebag IOL implantation
下载PDF
Direct Synthesis of Layer-Tunable and Transfer-Free Graphene on Device-Compatible Substrates Using Ion Implantation Toward Versatile Applications
11
作者 Bingkun Wang Jun Jiang +7 位作者 Kevin Baldwin Huijuan Wu Li Zheng Mingming Gong Xuehai Ju Gang Wang Caichao Ye Yongqiang Wang 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2024年第5期408-418,共11页
Direct synthesis of layer-tunable and transfer-free graphene on technologically important substrates is highly valued for various electronics and device applications.State of the art in the field is currently a two-st... Direct synthesis of layer-tunable and transfer-free graphene on technologically important substrates is highly valued for various electronics and device applications.State of the art in the field is currently a two-step process:a high-quality graphene layer synthesis on metal substrate through chemical vapor deposition(CVD)followed by delicate layer transfer onto device-relevant substrates.Here,we report a novel synthesis approach combining ion implantation for a precise graphene layer control and dual-metal smart Janus substrate for a diffusion-limiting graphene formation to directly synthesize large area,high quality,and layer-tunable graphene films on arbitrary substrates without the post-synthesis layer transfer process.Carbon(C)ion implantation was performed on Cu-Ni film deposited on a variety of device-relevant substrates.A well-controlled number of layers of graphene,primarily monolayer and bilayer,is precisely controlled by the equivalent fluence of the implanted C-atoms(1 monolayer~4×10^(15)C-atoms/cm^(2)).Upon thermal annealing to promote Cu-Ni alloying,the pre-implanted C-atoms in the Ni layer are pushed toward the Ni/substrate interface by the top Cu layer due to the poor C-solubility in Cu.As a result,the expelled C-atoms precipitate into a graphene structure at the interface facilitated by the Cu-like alloy catalysis.After removing the alloyed Cu-like surface layer,the layer-tunable graphene on the desired substrate is directly realized.The layer-selectivity,high quality,and uniformity of the graphene films are not only confirmed with detailed characterizations using a suite of surface analysis techniques but more importantly are successfully demonstrated by the excellent properties and performance of several devices directly fabricated from these graphene films.Molecular dynamics(MD)simulations using the reactive force field(ReaxFF)were performed to elucidate the graphene formation mechanisms in this novel synthesis approach.With the wide use of ion implantation technology in the microelectronics industry,this novel graphene synthesis approach with precise layer-tunability and transfer-free processing has the promise to advance efficient graphene-device manufacturing and expedite their versatile applications in many fields. 展开更多
关键词 device applications dual-metal smart Janus substrate growth mechanism Ion implantation layer-tunable and transfer-free graphene
下载PDF
Effect of capsule treatment on visual acuity and quality after phacoemulsification lens implantation in myopic patients with cataract
12
作者 Wei Liu Qi Liu +2 位作者 Fang Zhou Bo Feng Wan-Ling Wu 《World Journal of Clinical Cases》 SCIE 2024年第19期3882-3889,共8页
BACKGROUND Cataracts pose a significant clinical burden due to their complex pathogenesis.In recent years,an increase in cataracts coexisting with myopia has heightened the incidence of retinopathy and posterior vitre... BACKGROUND Cataracts pose a significant clinical burden due to their complex pathogenesis.In recent years,an increase in cataracts coexisting with myopia has heightened the incidence of retinopathy and posterior vitreous detachment.Additionally,symptoms of ocular axis elongation,lens nucleus hardening,and vitreous liquefaction have become more prevalent.While conventional extracapsular cataract extraction is commonly employed,it often yields suboptimal visual outcomes.Subsequent advancements in cataract phacoemulsification and lens implantation surgeries have gained widespread acceptance for their ability to improve refraction and significantly improve uncorrected visual acuity.AIM To investigate the effect of capsular treatment after phacoemulsification lens implantation in myopic patients with cataract.METHODS We selected 110 patients(with 134 eyes)with myopia and cataracts treated.These patients were categorized into two groups:an observation group(57 patients with 70 eyes)and a control group(53 patients with 64 eyes).The control group underwent cataract phacoemulsification and lens implantation,while the observation group received a refined capsular treatment based on the control group’s procedure.We assessed the differences in visual acuity and quality between the two groups before and after surgery.RESULTS At six months post-operation,the observation group exhibited significantly improved far vision,intermediate vision,near vision,lower objective scattering index,higher Modulation transfer function cut-off frequency,and overall vision metrics at different contrast levels(100%,20%and 9%)compared to the control group(P<0.05).The total score of the National Eye Institute Visual Function Questionnaire in the observation group at 6 months after operation was significantly higher than that in the control group(P<0.05).No significant difference in the incidence of adverse reactions was observed between the observation group and control group(P>0.05).CONCLUSION Capsular treatment demonstrates efficacy in improving visual acuity and quality after phacoemulsification lens implantation in myopic patients with cataracts,warranting its clinical application. 展开更多
关键词 Capsular treatment MYOPIA CATARACT Phacoemulsification and lens implantation Visual acuity Visual quality Uncorrected visual acuity
下载PDF
Effects of systematic cardiac rehabilitation training in elderly patients with unstable angina following cardiac stent implantation
13
作者 Ling-Ling Yan Xue Yang +1 位作者 Lu Chen Xiao Lu 《World Journal of Clinical Cases》 SCIE 2024年第20期4137-4145,共9页
BACKGROUND Coronary stent implantation is usually used to treat unstable angina to alleviate stenosis or occlusion,promoting blood flow restoration and alleviating symptoms such as myocardial ischemia.And postoperativ... BACKGROUND Coronary stent implantation is usually used to treat unstable angina to alleviate stenosis or occlusion,promoting blood flow restoration and alleviating symptoms such as myocardial ischemia.And postoperative cardiac rehabilitation is essential for enhancing recovery and prognosis.Nevertheless,conventional rehabilitation lacks specificity,particularly for elderly patients with multiple comorbidities and poor compliance,rendering it less effective.AIM To investigate the effects of systematic cardiac rehabilitation training in elderly patients with unstable angina following coronary stenting intervention.METHODS A retrospective enrollment was conducted comprising fifty-four elderly patients with unstable angina pectoris who underwent systematic cardiac rehabilitation training after receiving coronary intervention as the rehabilitation group,while fifty-three elderly patients who received basic nursing and rehabilitation guidance measures after coronary intervention were assigned to the control group.Differences in Seattle Angina Questionnaire scores,survival quality(SF-36)scores,cardiopulmonary exercise function assessment index,echocardiographic cardiac function index,and adverse cardiovascular events were compared between the two groups.RESULTS After intervention,the rehabilitation group observed greater VO2 Max,maximum metabolic equivalent,eft ventricular ejection fraction,left ventricular end-diastolic diameter and smaller left ventricular end-systolic diameter.And the rehabilitation group observed greater scores of physical activity limitation,stable angina pectoris,treatment satisfaction,and SF-36 score.The incidence of adverse cardiovascular events in the two groups,showed no significant difference.CONCLUSION Systematic cardiac rehabilitation following coronary stenting in elderly patients with unstable angina pectoris can enhance cardiac function recovery,consequently enhancing both quality of life and cardiopulmonary exercise tolerance. 展开更多
关键词 Systematicity Cardiac rehabilitation training Unstable angina pectoris Coronary stenting implantation Interventional surgery Quality of life Cardiac function Exercise tolerance
下载PDF
Clinical Effect Analysis of Posterior Chamber Intraocular Lens Implantation for Correcting High Myopia and Astigmatism
14
作者 Bo Xia Dan Dan Zhao 《Journal of Clinical and Nursing Research》 2024年第8期99-104,共6页
Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the ca... Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety. 展开更多
关键词 Posterior chamber intraocular lens implantation in phakic eyes High myopia ASTIGMATISM Corrective effect
下载PDF
Effects of Continuous Precision Nursing Model on Knowledge, Attitudes, and Practices (KAP) Behavior and Cardiac Function in Patients after Percutaneous Coronary Angiography and Stent Implantation
15
作者 Cuiying Han 《Journal of Clinical and Nursing Research》 2024年第3期1-6,共6页
Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary a... Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary angiography and stent implantation.Methods:Ninety patients who underwent percutaneous coronary angiography and stent implantation in our hospital from April 2022 to April 2023 were selected and randomly divided into the control group(45 cases),in which routine nursing support was carried out during the treatment process,and the observation group(45 cases),in which continuous precision nursing model was carried out during the treatment process.Comparisons were made between the two groups of patients on their KAP,cardiac function,and quality of life during recovery.Results:There was no difference in the left ventricular ejection fraction(LVEF),cardiac output(CO),and cardiac index(CI)levels before intervention.After the intervention,the levels of cardiac function in the observation group were higher than those of the control group(P<0.05).There was no difference in the Exercise of Self-Care Agency(ESCA)self-care ability scale scores before the intervention.After the intervention,the observation group had higher ESCA scores than the control group(P<0.05).Conclusion:Implementation of a continuous precision nursing model in the care of patients undergoing percutaneous coronary angiography and stent implantation improved the patient’s cardiac function,and KAP,and promoted recovery. 展开更多
关键词 Continuous precision nursing model Percutaneous coronary angiography Stent implantation Knowledge attitudes and practices(KAP) Cardiac function
下载PDF
Screening of Biocontrol Strain Bacillus subtilis by N^+ Ion Beam Implantation 被引量:5
16
作者 刘桂君 孟佑婷 +2 位作者 杨素玲 包放 尚宏忠 《Agricultural Science & Technology》 CAS 2012年第8期1658-1663,共6页
[Objective] This study was to investigate the effect of N+ ion beam implantation on the survival rate and mutation rate of biocontrol strain Bacillus subtilis. [Method] The factors influencing B. subtilis ion beam im... [Objective] This study was to investigate the effect of N+ ion beam implantation on the survival rate and mutation rate of biocontrol strain Bacillus subtilis. [Method] The factors influencing B. subtilis ion beam implantation, including culture time, dilution concentration, solvent, drying time of mycoderm were optimized. B. subtilis cells were implanted by using ion beam at dose of 2.0×10^14~4.0×10^14 ions/cm2 and the energy of 30 kev. Then the methods of culturing colonies confronting each other on plate and Oxford cup diffusion were used to screening strains. [Result] The optimal parameters were found as follows: culture in liquid for 20-24 h, dilution with sterile water to 106 cells/ml and drying time of 60 min for sample preparation; the optimal N+ ion beam implantation dose of 2.0×10^14~4.0×10^14 ions/cm2 at the energy of 30 kev, the survival rate of 8.43%-26.71% and the mutation rate of 3.50%-5.43%. [Conclusion] This study provided reference for ion beam implantation mutation of B. subtilis. 展开更多
关键词 Ion beam implantation Survival rate Mutation rate Bacillus subtilis
下载PDF
通过成结模拟器研究n^(+)-n^(-)-p碲镉汞高温探测器
17
作者 林加木 周松敏 +3 位作者 王溪 甘志凯 林春 丁瑞军 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2024年第1期23-28,共6页
第三代红外探测器发展的一个重要方向是高工作温度探测器。对于碲镉汞n-on-p探测器而言,n^(+)-n^(-)-p结构以及良好的钝化工艺能够有效的抑制暗电流的产生,从而在高工作温度条件下获得较好的探测器性能。基于自行开发的成结模拟器,对n^(... 第三代红外探测器发展的一个重要方向是高工作温度探测器。对于碲镉汞n-on-p探测器而言,n^(+)-n^(-)-p结构以及良好的钝化工艺能够有效的抑制暗电流的产生,从而在高工作温度条件下获得较好的探测器性能。基于自行开发的成结模拟器,对n^(+)-n^(-)-p结构地高温器件进行了工艺仿真和器件仿真,获得成结过程的制备参数,并结合抑制表面漏电的组分梯度钝化工艺,将高工作温度下的暗电流抑制至理论极限,研制出可以在更高温度工作下的碲镉汞n-on-p红外焦平面探测器。经测试,中波n-on-p红外焦平面器件在不同工作温度下性能优异,在80 K工作温度下噪声等效温差(NETD)达到了6.1 mK,有效像元率为99.96%;而在150 K工作温度下噪声等效温差(NETD)为11.0 mK,有效像元率为99.50%,达到了同类器件的理论极限。 展开更多
关键词 碲镉汞 n^(+)-n^(-)-p 高工作温度 红外焦平面
下载PDF
Postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens implantation versus small incision lenticule extraction in myopic eyes:a Meta-analysis 被引量:4
18
作者 Hong-Yu Li Zi Ye Zhao-Hui Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第3期442-452,共11页
AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,W... AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group. 展开更多
关键词 implantable collamer lens small incision lenticule extraction MYOPIA refractive surgery META-ANALYSIS
下载PDF
Role of dendritic cells in MYD88-mediated immune recognition and osteoinduction initiated by the implantation of biomaterials 被引量:1
19
作者 Zifan Zhao Qin Zhao +6 位作者 Hu Chen Fanfan Chen Feifei Wang Hua Tang Haibin Xia Yongsheng Zhou Yuchun Sun 《International Journal of Oral Science》 SCIE CAS CSCD 2023年第3期411-421,共11页
Bone substitute material implantation has become an important treatment strategy for the repair of oral and maxillofacial bone defects.Recent studies have shown that appropriate inflammatory and immune cells are essen... Bone substitute material implantation has become an important treatment strategy for the repair of oral and maxillofacial bone defects.Recent studies have shown that appropriate inflammatory and immune cells are essential factors in the process of osteoinduction of bone substitute materials.Previous studies have mainly focused on innate immune cells such as macrophages.In our previous work,we found that T lymphocytes,as adaptive immune cells,are also essential in the osteoinduction procedure.As the most important antigen-presenting cell,whether dendritic cells(DCs)can recognize non-antigen biomaterials and participate in osteoinduction was still unclear.In this study,we found that surgical trauma associated with materials implantation induces necrocytosis,and this causes the release of high mobility group protein-1(HMGB1),which is adsorbed on the surface of bone substitute materials.Subsequently,HMGB1-adsorbed materials were recognized by the TLR4-MYD88-NFκB signal axis of dendritic cells,and the inflammatory response was activated.Finally,activated DCs release regeneration-related chemokines,recruit mesenchymal stem cells,and initiate the osteoinduction process.This study sheds light on the immune-regeneration process after bone substitute materials implantation,points out a potential direction for the development of bone substitute materials,and provides guidance for the development of clinical surgical methods. 展开更多
关键词 implantation BIOMATERIALS release
下载PDF
N^(6)-甲基腺苷修饰在动脉粥样硬化中的作用及药物干预的研究进展 被引量:1
20
作者 张晓璐 耿妙颖 +3 位作者 王雲 蒙胜勇 王一婧 姜希娟 《中国动脉硬化杂志》 CAS 2024年第4期277-284,共8页
N^(6)-甲基腺苷(m 6A)修饰是真核生物mRNA中最常见的表观转录组修饰形式之一,具有动态可逆性。该修饰过程由甲基转移酶、去甲基化酶和与m 6A结合的蛋白质协同作用,影响mRNA的代谢和功能。越来越多的研究表明,m 6A RNA修饰在动脉粥样硬化... N^(6)-甲基腺苷(m 6A)修饰是真核生物mRNA中最常见的表观转录组修饰形式之一,具有动态可逆性。该修饰过程由甲基转移酶、去甲基化酶和与m 6A结合的蛋白质协同作用,影响mRNA的代谢和功能。越来越多的研究表明,m 6A RNA修饰在动脉粥样硬化(As)等多种疾病的发生和发展中扮演重要角色。文章综述了m 6A RNA修饰与As的关系。全文对m 6A RNA修饰机制以及在As相关细胞(如内皮细胞、巨噬细胞和平滑肌细胞)中的作用进行了全面总结,并探讨了m 6A RNA修饰与As危险因素,如高脂饮食、缺血缺氧、振荡应力及高血压的关联。最后,文章还对药物干预m 6A RNA甲基化以实现延缓As的研究进行了综述,为探索As早期诊断和治疗的新靶点提供了重要参考。 展开更多
关键词 动脉粥样硬化 N^(6)-甲基腺苷修饰 甲基转移酶 去甲基化酶 药物干预
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部