In this paper, poly(amide-6-β-ethylene oxide) (PEBA1657) copolymer was used to prepare multilayer polyetherimide (PEI)/polydimethylsiloxane (PDMS)/PEBA1657/PDMS composite membranes by dip-coating method. Permeation b...In this paper, poly(amide-6-β-ethylene oxide) (PEBA1657) copolymer was used to prepare multilayer polyetherimide (PEI)/polydimethylsiloxane (PDMS)/PEBA1657/PDMS composite membranes by dip-coating method. Permeation behaviors of ethylene, ethane, propylene, propane, n-butane, methane and nitrogen through the multilayer composite membranes were investigated over a range of operating temperature and pressure. The permeances of light hydrocarbons through PEI/PDMS/PEBA1657/PDMS composite membranes increase with their increasing condensability, and the olefins are more permeable than their corresponding paraffins. For light hydrocarbons, the gas permeances increase significantly as temperature increasing. When the transmembrane pressure difference increases, the gas permeance increases moderately due to plasticization effect, while their apparent activation energies for permeation decrease.展开更多
基金Supported by Key Projects in the National Science & Technology Pillar Program (2011BAC08B00)
文摘In this paper, poly(amide-6-β-ethylene oxide) (PEBA1657) copolymer was used to prepare multilayer polyetherimide (PEI)/polydimethylsiloxane (PDMS)/PEBA1657/PDMS composite membranes by dip-coating method. Permeation behaviors of ethylene, ethane, propylene, propane, n-butane, methane and nitrogen through the multilayer composite membranes were investigated over a range of operating temperature and pressure. The permeances of light hydrocarbons through PEI/PDMS/PEBA1657/PDMS composite membranes increase with their increasing condensability, and the olefins are more permeable than their corresponding paraffins. For light hydrocarbons, the gas permeances increase significantly as temperature increasing. When the transmembrane pressure difference increases, the gas permeance increases moderately due to plasticization effect, while their apparent activation energies for permeation decrease.
文摘目的:采用高分辨液质联用技术快速分析和推定泊马度胺胶囊中的降解产物。方法:采用Agilent ZORBAX SB-CN色谱柱(150 mm×4.6 mm,5 mm),以质谱兼容性0.1%甲酸水溶液-甲醇为流动相,梯度洗脱,流速1.0 m L·min^(-1),检测波长为240 nm,对泊马度胺胶囊经酸、碱、高温、氧化及光照破坏产生的有关物质进行分离。通过电喷雾正离子化四极杆-飞行时间质谱(Q-TOF/MS)测定各有关物质的精确分子质量及分子式,再根据二级质谱(MS/MS)碎裂信息推定未知降解产物结构;喷雾电压3.5 k V,雾化器流量11 L·min^(-1),去溶剂气温度350℃,离子源气压310 k Pa,驱簇电压120 V,MS扫描范围m/z 100~1 000,MS/MS扫描范围m/z 50~800,MS/MS碰撞能量10~20 e V。结果:建立的HPLC分析方法下各有关物质与主成分分离良好,在强制降解供试品溶液中共检测到14个主要有关物质,经液质初步分析推定了它们的结构分别为泊马度胺的水解产物(有关物质1、2、3、7和8),3-氨基-1,2-苯二甲酸(有关物质4),2-硝基-6-[[(2,6-二氧代-3-哌啶基)氨基]羰基]-苯甲酸(有关物质5),2-亚硝基-6-[[(2,6-二氧代-3-哌啶基)氨基]羰基]-苯甲酸(有关物质6),N′-[2-(2,6-二氧代哌啶-3-基)-1,3-二氧代-4-异二氢吲哚]-乙酰肼(有关物质9),泊马度胺羟基化产物(有关物质10和12),3-硝基-N-(2,6-二氧-3-哌啶基)苯邻二甲酰亚胺(有关物质11),3-甲基氨基-N-(2,6-二氧-3-哌啶基)苯邻二甲酰亚胺(有关物质13),泊马度胺的羟基化二聚体产物(有关物质14)。结论:新建立的液质联用方法适用于泊马度胺胶囊中有关物质的检查,为泊马度胺制剂质量控制和工艺优化提供重要参考。