期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Performance of a New Ion Source for KSTAR Tokamak Plasma Heating
1
作者 Tae-Seong KIM Seung Ho JEONG +2 位作者 Doo Hee CHANG Kwang Won LEE Sang-Ryul IN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第6期620-624,共5页
In the experimental campaign of 2010 and 2011 on KSTAR, the NBI-1 system was equipped with one prototype ion source and operated successfully, providing a neutral beam power of 0.7-1.6 MW to the tokamak plasma. The ne... In the experimental campaign of 2010 and 2011 on KSTAR, the NBI-1 system was equipped with one prototype ion source and operated successfully, providing a neutral beam power of 0.7-1.6 MW to the tokamak plasma. The new ion source planned for the 2012 KSTAR campaign had a much more advanced performance compared with the previous one. The target performance of the new ion source was to provide a neutral deuterium beam of 2 MW to the tokamak plasma. The ion source was newly designed, fabricated, and assembled in 2011. The new ion source was then conditioned up to 64 A/100 keV over a 2-hour beam extraction and performance tested at the NB test stand (NBTS) at the Korea Atomic Energy Research Institute (KAERI) in 2012. The measured optimum perveance at which the beam divergence is a minimum was about 2.5μP, and the minimum beam divergent angle was under 1.0° at 60 keV. These results indicate that the 2.0 MW neutral beam power at 100 keV required for the heating of plasma in KSTAR can be delivered by the installation of the new ion source in the KSTAR NBI-1 system. 展开更多
关键词 nbi ion source KSTAR neutral beam plasma heating positive based ion
下载PDF
NBI双潘宁离子源参数的静电探针测量 被引量:3
2
作者 陈开云 胡纯栋 +3 位作者 刘胜 李军 韩筱璞 刘智民 《核电子学与探测技术》 CAS CSCD 北大核心 2006年第4期517-520,共4页
介绍了静电探针在22cm双潘宁离子源中心等离子体参数测量中的应用。测出了探针的伏安特性曲线,由该曲线求出在弧流为200 A时,电子温度约为6.0 eV,密度约为2×1012cm-3,这对于调整放电控制条件,获得高效率大功率的离子源有重要的参... 介绍了静电探针在22cm双潘宁离子源中心等离子体参数测量中的应用。测出了探针的伏安特性曲线,由该曲线求出在弧流为200 A时,电子温度约为6.0 eV,密度约为2×1012cm-3,这对于调整放电控制条件,获得高效率大功率的离子源有重要的参考价值,并且对于今后实现强而且均匀的中性束束流的引出也有着重要意义。 展开更多
关键词 中性束注入器 双潘宁离子源 静电探针 等离子体参数
下载PDF
Preliminary Results of Ion Beam Extraction Tests on EAST Neutral Beam Injector 被引量:4
3
作者 胡纯栋 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第10期871-873,共3页
The neutral beam injection (NBI) system is one of the most important auxiliary plasma heating and current driving methods for fusion device. A high power ion beam of 3 MW with 80 keV beam energy in 0.5 s beam durati... The neutral beam injection (NBI) system is one of the most important auxiliary plasma heating and current driving methods for fusion device. A high power ion beam of 3 MW with 80 keV beam energy in 0.5 s beam duration and a long pulse ion beam of 4 s with 50 keV beam energy ion beam extraction were achieved on the EAST neutral beam injector on the teststand. The preliminary results show that the EAST-NBI system was developed successfully on schedule. 展开更多
关键词 nbi beam extraction ion source
下载PDF
Achievement of 100 s Long Pulse Neutral Beam Extraction in EAST Neutral Beam Injector 被引量:2
4
作者 胡纯栋 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第3期201-203,共3页
Neutral beam injection (NBI) is recognized as one of the most effective means for plasma heating. A 100 s long pulse neutral beam with 30 keV beam energy, 10 A beam current and a 100 s long pulse modulating neutral ... Neutral beam injection (NBI) is recognized as one of the most effective means for plasma heating. A 100 s long pulse neutral beam with 30 keV beam energy, 10 A beam current and a 100 s long pulse modulating neutral beam with 50 keV beam energy, 16 A beam current were achieved in the EAST neutral beam injector on the test-stand. The preliminary results suggest that EAST-NBI system initially possess the ability of long pulse beam extraction. 展开更多
关键词 nbi beam extrnction ion source
下载PDF
中性束注入强流离子源放电电源及其时序控制 被引量:7
5
作者 陈文光 饶军 +3 位作者 李波 雷光玖 王明伟 HL-2A NBI组 《高电压技术》 EI CAS CSCD 北大核心 2011年第6期1452-1458,共7页
中性束注入是磁约束核聚变装置中加热等离子体最有效方法之一。为了建设完善中国环流器2号A装置1MW中性束注入器系统,对大功率强流离子源所需的弧放电电源、束线引出电源、辅助电源及控制时序等进行了设计研制。设计中采用了DSP控制技... 中性束注入是磁约束核聚变装置中加热等离子体最有效方法之一。为了建设完善中国环流器2号A装置1MW中性束注入器系统,对大功率强流离子源所需的弧放电电源、束线引出电源、辅助电源及控制时序等进行了设计研制。设计中采用了DSP控制技术、电流快速转移技术、IGBT串联调制器技术、高频开关电源技术、磁缓冲器技术以及工业以太网等诸多技术。该系统已经稳定地运行3a时间,开展了高参数注入实验,注入装置的中性束功率接近1MW,瞬时离子束功率超过2MW,脉冲宽度达到1s,在国内首次使等离子体离子温度超过2×107°C。实验结果表明:所研制的电源及控制系统能有效地用于强流离子束的引出和保护,完全满足HL-2A装置辅助加热系统的要求。 展开更多
关键词 中国环流器2号 中性束注入(nbi) 等离子体 强流离子源 弧放电电源 引出电源 控制时序
下载PDF
中性束注入器用串联高压缓冲器优化设计 被引量:1
6
作者 程德胜 李格 +2 位作者 谢飞 袁红文 付鹏 《高电压技术》 EI CAS CSCD 北大核心 2014年第1期250-255,共6页
为了优化中性束注入器(NBI)用高压缓冲器的布局,分析了缓冲器结构设计参数和缓冲器性能的相互关系,并通过等效电路仿真模型修正了缓冲器放电峰值电流经验公式,得到了不同激励信号下串联高压缓冲器在高频脉冲放电情况下的特性,最后,在高... 为了优化中性束注入器(NBI)用高压缓冲器的布局,分析了缓冲器结构设计参数和缓冲器性能的相互关系,并通过等效电路仿真模型修正了缓冲器放电峰值电流经验公式,得到了不同激励信号下串联高压缓冲器在高频脉冲放电情况下的特性,最后,在高压缓冲器理论分析和仿真分析的基础上,对设计的非晶缓冲器和Deltmax缓冲器串联高压测试件进行了短路放电测试,得到了短路放电瞬间串联缓冲器的分压和回路的放电电流。放电实验结果表明,黑色非晶缓冲器感应电压频率响应比较快,Deltmax缓冲器可以消耗更多的故障电流能量,非晶缓冲器和Deltmax缓冲器这2种不同直流缓冲器的串联能够有效地抑制高压直流故障短路电流并吸收故障电能。 展开更多
关键词 中性束注入器 nbi 离子源 高压缓冲器 串联 分布电容 放电实验
下载PDF
HL-2M装置中性束注入加热系统研制进展 被引量:5
7
作者 曹建勇 魏会领 +19 位作者 刘鹤 邹桂清 杨宪福 张贤明 唐立新 罗萃文 余佩炫 耿少飞 周红霞 周博文 李青 何峰 罗怀宇 周健 任磊磊 潘春花 黄高扬 雷光玖 饶军 段旭如 《强激光与粒子束》 EI CAS CSCD 北大核心 2018年第10期122-130,共9页
为开展磁约束堆芯燃烧等离子体物理实验,正在建造的HL-2M装置拟建造3条5MW的中性束注入加热束线。简要概述了HL-2M装置NBI加热系统的总体规划,第1条5MW-NBI加热束线的设计,离子源调试实验,注入器核心部件的安装和测试结果。通过调试,目... 为开展磁约束堆芯燃烧等离子体物理实验,正在建造的HL-2M装置拟建造3条5MW的中性束注入加热束线。简要概述了HL-2M装置NBI加热系统的总体规划,第1条5MW-NBI加热束线的设计,离子源调试实验,注入器核心部件的安装和测试结果。通过调试,目前单个离子源引出束流达到36A,加速电压75kV,离子束功率达到2.4MW,脉冲宽度3s。通过测试发现:注入器的4条离子束汇聚角误差小于±0.1°,残留离子偏转磁体的磁场测试值与模拟计算值偏差小于±5%,注入器静态真空值达到1.0×10^(-3)Pa。注入器采用大型非标低温泵,低温泵的抽速达到2.40×106L/s。第1条5MW-NBI加热束线的试装和测试结果表明,该束线能够满足HL-2M装置NBI加热的技术要求。 展开更多
关键词 nbi加热束线 注入器 离子源 低温泵
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部