The influence of transforming pH values on the electrochemical performance of nano-scale Ni (OH)2 was analyzed. The measurement results of XRD indicate that the nano-scale Ni (OH) 2 prepared at different transform...The influence of transforming pH values on the electrochemical performance of nano-scale Ni (OH)2 was analyzed. The measurement results of XRD indicate that the nano-scale Ni (OH) 2 prepared at different transformations of pH value is β ( Ⅱ )-phase with different crystal lattice parameters. Cyclic voltammograms (CV) and electrochemical impedance spectroscopy(EIS) measurement results show that transformations of pH value affect the proton diffusion coefficient (D) and charge-transfer resistance (Re,) of the material. The simulation of.cell experiment shows that the sample prepared at a pH of 10. 1 exhibits the maximum specific capacity (327.8 mAh/g) and higher discharge platform, the discharge performance of electrodes depends on both D and Rct, so the kinetics characteristics that electrodes reaction is controlled by both mass-transfer step and charge- transfer step are put forward.展开更多
Environmentally friendly, polyacrylic-based polyurethane dispersion (PUD) was synthesised using various molar ratios of polycaprolactone, dimethylolpropionic acid and tetramethyl xylene diisocyanate. Synthesis was car...Environmentally friendly, polyacrylic-based polyurethane dispersion (PUD) was synthesised using various molar ratios of polycaprolactone, dimethylolpropionic acid and tetramethyl xylene diisocyanate. Synthesis was carried out in flowing nitrogen atmosphere. The PUD’s preparations are free of NMP (n-methyl pyrrolidone), a toxic processing solvent generally used during the preparation of PUD’s. The performance of the synthesised polyurethane dispersions with varying NCO/OH molar ratio was tested on wood surface. The physical, chemical, thermal and mechanical properties such as viscosity, particle size, chemical resistance, thermal stability and taber abrasion of applied polyurethane dispersion were carried out as a function of NCO/OH molar ratio. The PUD’s preparation with NCO/OH ratio of 1.4 or 1.6 showed better performance as a wood finish and the results are described in the present study.展开更多
Resulting from the rising levels of atmospheric carbon, ocean acidification has become a global problem. It has significant impacts on the development, survival, growth and physiology of marine organisms. Therefore, a...Resulting from the rising levels of atmospheric carbon, ocean acidification has become a global problem. It has significant impacts on the development, survival, growth and physiology of marine organisms. Therefore, a high- precision sensor is urgently needed to measure the pH of sea-water. Iridium wire with a diameter of 0.25 mm is used as the substrate, and an Ir/Ir(OH)x pH electrode is prepared by a one-step electrochemical method in a LiOH solution at the room temperature. A scanning electron microscope (SEM) observation reveals that it is coated with nanoscale particles. In laboratory tests, the electrode exhibits a very promising pH response, with an ideal Nernst slope (56.14-59.52), fast response, good stability and long fife-span in tested pH buffer solutions. For a sea trial, four pH electrodes and one Ag/AgC1 reference electrode are integrated with a self-made chemical sensor, and a profile detection of nearly 70 m is implemented near Newport Harbor, California on August 3, 2015. The results reflect that the pH value measured by the sensor is very close to the data given by Sea-Bird 911 plus CTD, with a difference value ranging from 0.000 075 to 0.064 719. And the sensor shows a better data matching degree in 0-40 m water depth. In addition, the high precision and accuracy of the sensor make it possible to use in the ocean observation field.展开更多
基金the National Natural Science Foundation of China (Grant No.20271015)
文摘The influence of transforming pH values on the electrochemical performance of nano-scale Ni (OH)2 was analyzed. The measurement results of XRD indicate that the nano-scale Ni (OH) 2 prepared at different transformations of pH value is β ( Ⅱ )-phase with different crystal lattice parameters. Cyclic voltammograms (CV) and electrochemical impedance spectroscopy(EIS) measurement results show that transformations of pH value affect the proton diffusion coefficient (D) and charge-transfer resistance (Re,) of the material. The simulation of.cell experiment shows that the sample prepared at a pH of 10. 1 exhibits the maximum specific capacity (327.8 mAh/g) and higher discharge platform, the discharge performance of electrodes depends on both D and Rct, so the kinetics characteristics that electrodes reaction is controlled by both mass-transfer step and charge- transfer step are put forward.
文摘Environmentally friendly, polyacrylic-based polyurethane dispersion (PUD) was synthesised using various molar ratios of polycaprolactone, dimethylolpropionic acid and tetramethyl xylene diisocyanate. Synthesis was carried out in flowing nitrogen atmosphere. The PUD’s preparations are free of NMP (n-methyl pyrrolidone), a toxic processing solvent generally used during the preparation of PUD’s. The performance of the synthesised polyurethane dispersions with varying NCO/OH molar ratio was tested on wood surface. The physical, chemical, thermal and mechanical properties such as viscosity, particle size, chemical resistance, thermal stability and taber abrasion of applied polyurethane dispersion were carried out as a function of NCO/OH molar ratio. The PUD’s preparation with NCO/OH ratio of 1.4 or 1.6 showed better performance as a wood finish and the results are described in the present study.
基金The Key Laboratory Project of State Oceanic Administration for Marine Ecosystem and Biogeochemistry of China under contract No.529101-X21601the Foundation from Wendy Schmidt Ocean Health XPRIZE and the Southern California Coastal Water Research Project
文摘Resulting from the rising levels of atmospheric carbon, ocean acidification has become a global problem. It has significant impacts on the development, survival, growth and physiology of marine organisms. Therefore, a high- precision sensor is urgently needed to measure the pH of sea-water. Iridium wire with a diameter of 0.25 mm is used as the substrate, and an Ir/Ir(OH)x pH electrode is prepared by a one-step electrochemical method in a LiOH solution at the room temperature. A scanning electron microscope (SEM) observation reveals that it is coated with nanoscale particles. In laboratory tests, the electrode exhibits a very promising pH response, with an ideal Nernst slope (56.14-59.52), fast response, good stability and long fife-span in tested pH buffer solutions. For a sea trial, four pH electrodes and one Ag/AgC1 reference electrode are integrated with a self-made chemical sensor, and a profile detection of nearly 70 m is implemented near Newport Harbor, California on August 3, 2015. The results reflect that the pH value measured by the sensor is very close to the data given by Sea-Bird 911 plus CTD, with a difference value ranging from 0.000 075 to 0.064 719. And the sensor shows a better data matching degree in 0-40 m water depth. In addition, the high precision and accuracy of the sensor make it possible to use in the ocean observation field.