A novel flow injection chemiluminescence (CL) method for the determination of ciprofloxacin (CPLX) was reported. The proposed method is based on luminescence produced by KMnO4-Na2S2O4-Tb^3+-CPLX chemiluminescence...A novel flow injection chemiluminescence (CL) method for the determination of ciprofloxacin (CPLX) was reported. The proposed method is based on luminescence produced by KMnO4-Na2S2O4-Tb^3+-CPLX chemiluminescence (CL) system. The effects of some critical experimental conditions were discussed and the optimization of working conditions was investigated. The linear dynamic range is 3.00 × 10^-8 - 9.00 × 10^-7 mol ·L-1 and the detection limit for CPLX is 4.40 × 10^-9 mol·L^-1. This method was applied to the determination of CPLX in tablet, urine, and serum samples and the recoveries of real sample analyses were in the range from 110 ± 4 to 104 ± 4.展开更多
文摘A novel flow injection chemiluminescence (CL) method for the determination of ciprofloxacin (CPLX) was reported. The proposed method is based on luminescence produced by KMnO4-Na2S2O4-Tb^3+-CPLX chemiluminescence (CL) system. The effects of some critical experimental conditions were discussed and the optimization of working conditions was investigated. The linear dynamic range is 3.00 × 10^-8 - 9.00 × 10^-7 mol ·L-1 and the detection limit for CPLX is 4.40 × 10^-9 mol·L^-1. This method was applied to the determination of CPLX in tablet, urine, and serum samples and the recoveries of real sample analyses were in the range from 110 ± 4 to 104 ± 4.