A multianalyte biosensor for the simultaneous determination of glucose and galactose was developed by immobilizing glucose oxidase (GOD) and galactose oxidase (GAO) on Nafion-modified thin film platinum disk electrod...A multianalyte biosensor for the simultaneous determination of glucose and galactose was developed by immobilizing glucose oxidase (GOD) and galactose oxidase (GAO) on Nafion-modified thin film platinum disk electrodes. The dual Pt working electrodes with disk shape and the surrounding ring shaped counter electrode were fabricated by thin film technology, which were integrated onto the same microchip. The response of the designed biosensor for glucose and galactose were linear up to 6.0 mmol/L and 3.5 mmol/L with sensitivities of 0.3 mA/mmol/L and 0.12 mA/mmol/L, respectively. No cross-talking effect was observed.展开更多
Herein, a convenient method based on a fullerene/multiwalled carbon nanotube/Nafion modified glassy carbon electrode (fullerene/MWCNT/Naf/GCE) for the electrochemical determination of caffeine (CAF) is reported. Cycli...Herein, a convenient method based on a fullerene/multiwalled carbon nanotube/Nafion modified glassy carbon electrode (fullerene/MWCNT/Naf/GCE) for the electrochemical determination of caffeine (CAF) is reported. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to study ionic exchange properties and conductivity the proposed electrode using [Fe(CN)6]3-/4- redox couple. Caffeine gave an irreversible oxidation peak around +1.33 V (vs. Ag/AgCl reference electrode) in HClO4 (pH 1). The linear dependence of the peak current with the square root of the scan rate showed that the electron transfer process is controlled by diffusion. After optimization of key analytical parameters involved in differential pulse voltammetry (DPV), the oxidation peak current varied linearly with CAF concentration in the range of 10 to 1000 μM. A detection limit of 7.289 × 10-8 M (S/N = 3) was found. Kinetic and chronocoulometric studies were also performed to characterize the diffusion of CAF. The developed electrode exhibited good stability and was easily regenerated. The influence of some potential interfering compounds such as dopamine, uric acid, glucose and sulfite ions on the anodic peak current of CAF was also examined. The proposed method was successfully employed in the determination of CAF in some commercial drugs.展开更多
文摘A multianalyte biosensor for the simultaneous determination of glucose and galactose was developed by immobilizing glucose oxidase (GOD) and galactose oxidase (GAO) on Nafion-modified thin film platinum disk electrodes. The dual Pt working electrodes with disk shape and the surrounding ring shaped counter electrode were fabricated by thin film technology, which were integrated onto the same microchip. The response of the designed biosensor for glucose and galactose were linear up to 6.0 mmol/L and 3.5 mmol/L with sensitivities of 0.3 mA/mmol/L and 0.12 mA/mmol/L, respectively. No cross-talking effect was observed.
文摘Herein, a convenient method based on a fullerene/multiwalled carbon nanotube/Nafion modified glassy carbon electrode (fullerene/MWCNT/Naf/GCE) for the electrochemical determination of caffeine (CAF) is reported. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to study ionic exchange properties and conductivity the proposed electrode using [Fe(CN)6]3-/4- redox couple. Caffeine gave an irreversible oxidation peak around +1.33 V (vs. Ag/AgCl reference electrode) in HClO4 (pH 1). The linear dependence of the peak current with the square root of the scan rate showed that the electron transfer process is controlled by diffusion. After optimization of key analytical parameters involved in differential pulse voltammetry (DPV), the oxidation peak current varied linearly with CAF concentration in the range of 10 to 1000 μM. A detection limit of 7.289 × 10-8 M (S/N = 3) was found. Kinetic and chronocoulometric studies were also performed to characterize the diffusion of CAF. The developed electrode exhibited good stability and was easily regenerated. The influence of some potential interfering compounds such as dopamine, uric acid, glucose and sulfite ions on the anodic peak current of CAF was also examined. The proposed method was successfully employed in the determination of CAF in some commercial drugs.