Simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation by ultra-high performance liquid chromatography coupled with nano quantity analyte detector
1
作者 Honggen Zhang ZhenyuWang Oscar Liu 《Journal of Pharmaceutical Analysis》 SCIE CAS 2016年第1期11-17,共7页
A novel method for simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation was developed using ultra-high performance liquid chromatography coupled with a nano quantitation analytical... A novel method for simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation was developed using ultra-high performance liquid chromatography coupled with a nano quantitation analytical detector (UHPLC-NQAD). All components in kolliphor HS15 and miglyo1812 were well separated on an Acquity BEH C18 column. Mobile phase A was 0.1% trifluoroacetic acid (TFA) in water and mobile phase B was acetonitrile. A gradient elution sequence was programed initially with 60% organic solvent, slowly increased to 100% within 8 min. The flow rate was 0.7 mL/min. Good linearity (r 〉 0.95) was obtained in the range of 27.6-1381.1 μg/mL for polyoxyl 15 hydroxystearate in kolliphor HS15, 0.8-202.0 μg/mL for caprylic acid triglyceride and 2.7-221.9μg/mL for capric acid triglyceride in miglyol 812. The relative standard deviations (RSD) ranged from 0.6% to 1.7% for intra-day precision and from 0.4% to 2.7% for inter-day precision. The overall recoveries (accuracy) were 99.7%-101.4% for polyoxyl 15 hydroxystearate in kolliphor HS15, 96.7%-99.6% for caprylic acid triglyceride, and 94.1%- 103.3% for capric acid triglyceride in miglyol 812. Quantification limits (QL) were determined as 27.6 μg/ mL for polyoxy115 hydroxystearate in kolliphor HS15, 0.8 μg/mL for caprylic acid triglyceride, and 2.7 μg/ mL for capric acid triglyceride in miglyol 812. No interferences were observed in the retention time ranges of kolliphor HSI5 and miglyol 812. The method was validated in terms of specificity, linearity, precision, accuracy, QL, and robustness. The proposed method has been applied to microemulsion for- mulation analyses with good recoveries (82.2%-103.4%). 展开更多
关键词 Kolliphor HS15 Miglyol 812 Ultra-high performance liquid chromato-graphy (UHPLC) nano quantitation analytical detector(nqad)
下载PDF
HPLC-NQAD和HPLC-ELSD法测定硫酸卡那霉素注射剂的含量 被引量:13
2
作者 王金凤 杨化新 +1 位作者 朱俐 尹利辉 《药物分析杂志》 CAS CSCD 北大核心 2014年第4期644-648,共5页
目的:采用HPLC—NQAD(水凝聚核粒子计数蒸发光检测器)法和HPLC—ELSD(中国药典方法)法测定硫酸卡那霉素注射液的含量,并对2种方法进行比较。方法:采用AgilentSBC18色谱柱(250mm×4.6mm,5μm),流动相为0.2%三氟乙酸溶... 目的:采用HPLC—NQAD(水凝聚核粒子计数蒸发光检测器)法和HPLC—ELSD(中国药典方法)法测定硫酸卡那霉素注射液的含量,并对2种方法进行比较。方法:采用AgilentSBC18色谱柱(250mm×4.6mm,5μm),流动相为0.2%三氟乙酸溶液-甲醇(80:20,V/V)。结果:卡那霉素进样量在195.2~1952ng范围内具有良好的线性,相关系数为0.9991,卡那霉素检出限为19.4ng,卡那霉素样品的加样回收率为99.7%(n=9)。结论:本方法具有较高的准确度、精密度和灵敏度,方法简便,可用于卡那霉素的检测分析。该方法较药典方法有较高的灵敏度,且峰面积与浓度直接线性响应。 展开更多
关键词 高效液相色谱 水凝聚粒子计数蒸发光检测 硫酸卡那霉素注射液