A simple and sensitive spectrophotometric method was described for the determination of cerium(IV) based on its catalytic effect on the oxidation of naphthol green B by potassium periodate in the medium of sulfuric ...A simple and sensitive spectrophotometric method was described for the determination of cerium(IV) based on its catalytic effect on the oxidation of naphthol green B by potassium periodate in the medium of sulfuric acid. The influences of acidity, concentration of reactants, reaction time, reaction temperature, and foreign ions were discussed, and the optimum reaction conditions were established. The reaction was monitored spectrophotometrieally by measuring the decrease in absorbance of naphthol green B at 710 nm after a fixed time (8 min). The proposed method allowed the determination of cerium(IV) in the range of 0.08-2.4 μg·mL^-1 with good precision and accuracy, and the detection limit was 0.012 μg·mL^-1. The method was applied successfully for the determination of trace cerium in hair samples without previous separation. Recovery experiments were also performed, and the recovery was between 95.7%-111.0%.展开更多
Naphthol green B was used, for the first time, as a new mediator in an amperometric glucose biosensor. It is a good mediator, promoting electron transfer from glucose oxidase to graphite electrode. The biosensor sho...Naphthol green B was used, for the first time, as a new mediator in an amperometric glucose biosensor. It is a good mediator, promoting electron transfer from glucose oxidase to graphite electrode. The biosensor shows high sensitivity to glucose at low potential with response time of 30 seconds. The linear range is from 1.5 to 18 靘ol/L glucose with detection limit of 0.5 靘ol/L glucose.展开更多
The study deals with adsorption of Naphthol Green B on two unburned carbons and the parent coal,from which the UCs have been created in a fluidised-bed power station.Particular attention has been paid to the adsorptio...The study deals with adsorption of Naphthol Green B on two unburned carbons and the parent coal,from which the UCs have been created in a fluidised-bed power station.Particular attention has been paid to the adsorption equilibrium modelling:experimental data has been analysed using 2-parameter(Langmuir,Freundlich) and3-parameter(Redlich-Peterson) isotherms — both linear and non-linear regressions have been used for the estimation of the isotherm parameters.In the case of both UCs,the Langmuir isotherm model provides the worst fit,whereas 2-parameter Freundlich and 3-parameter Redlich-Peterson models are both good,from which 3-parameter Redlich-Peterson isotherm provides slightly better results(despite the penalty used for the higher number of parameters).In the case of both UCs,the linear regression of Freundlich and Redlich-Peterson models provides good results(comparable with non-linear regressions).Unlike both UCs,the best fit of the experimental data from the adsorption on the coal has been achieved by the Langmuir isotherm model.The results based on the Freundlich or Redlich-Peterson model were(in this case) somewhat worse.展开更多
基金supported by the Natural Sci-ence Foundation of Shandong Province, China (No. Y2008B26)
文摘A simple and sensitive spectrophotometric method was described for the determination of cerium(IV) based on its catalytic effect on the oxidation of naphthol green B by potassium periodate in the medium of sulfuric acid. The influences of acidity, concentration of reactants, reaction time, reaction temperature, and foreign ions were discussed, and the optimum reaction conditions were established. The reaction was monitored spectrophotometrieally by measuring the decrease in absorbance of naphthol green B at 710 nm after a fixed time (8 min). The proposed method allowed the determination of cerium(IV) in the range of 0.08-2.4 μg·mL^-1 with good precision and accuracy, and the detection limit was 0.012 μg·mL^-1. The method was applied successfully for the determination of trace cerium in hair samples without previous separation. Recovery experiments were also performed, and the recovery was between 95.7%-111.0%.
文摘Naphthol green B was used, for the first time, as a new mediator in an amperometric glucose biosensor. It is a good mediator, promoting electron transfer from glucose oxidase to graphite electrode. The biosensor shows high sensitivity to glucose at low potential with response time of 30 seconds. The linear range is from 1.5 to 18 靘ol/L glucose with detection limit of 0.5 靘ol/L glucose.
基金Supported by the project No.LO1404(Sustainable Development of Center ENET-Energy Units for the Utilization of Non-Traditional Energy Sources)project No.LO 1203(Regional Materials Science and Technology Centre-Feasibility Program)+1 种基金the project No.LO1406(Institute of Clean Technologies for Mining and Utilization of Raw Materials for Energy Use-Sustainability Programsupported by the National Programme for Sustainability I 2013-2020
文摘The study deals with adsorption of Naphthol Green B on two unburned carbons and the parent coal,from which the UCs have been created in a fluidised-bed power station.Particular attention has been paid to the adsorption equilibrium modelling:experimental data has been analysed using 2-parameter(Langmuir,Freundlich) and3-parameter(Redlich-Peterson) isotherms — both linear and non-linear regressions have been used for the estimation of the isotherm parameters.In the case of both UCs,the Langmuir isotherm model provides the worst fit,whereas 2-parameter Freundlich and 3-parameter Redlich-Peterson models are both good,from which 3-parameter Redlich-Peterson isotherm provides slightly better results(despite the penalty used for the higher number of parameters).In the case of both UCs,the linear regression of Freundlich and Redlich-Peterson models provides good results(comparable with non-linear regressions).Unlike both UCs,the best fit of the experimental data from the adsorption on the coal has been achieved by the Langmuir isotherm model.The results based on the Freundlich or Redlich-Peterson model were(in this case) somewhat worse.